• Title/Summary/Keyword: Test procedures

Search Result 1,857, Processing Time 0.03 seconds

Quantitative Analysis of Effects for Quality Control on Medical Primary Class LCD Display Devices Based on AAPM TG18 Report (AAPM TG18에 의한 진단용 LCD 디스플레이 장치 정도관리 효과의 정량적 분석)

  • Jung Hai-Jo;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.77-82
    • /
    • 2006
  • The image display is an Important component of PACS and of medical digital imaging chain. Displayed image qualify is affected by the physical characteristics of display device, appropriate clinical settings and calibrations, and ambient lighting conditions. The performance of display systems is continuously degraded over time due to luminance deterioration and changes of clinical setting parameters. A routine QC is recommended because the performance of display systems is continuously degraded over time. Ten flat panel monochrome LCD display devices were included in the evaluation of the QC effect. The effect of QC on primary class LCD medical display devices for selected QC tests was evaluated by comparing the performances, luminance response, luminance dependencies, display resolution and display chromaticity in this study, of before and after the calibration procedures. The effects of the QC are significant to luminance response and luminance spatial dependencies test and the other side, are slight to the display resolution and display chromaticity test. A routine QC of display device is essential for the consistency of medical image display and presentation. The study of the QC effects of display devices will play an important role in practical QC procedures of display devices.

  • PDF

Analysis of Public System's Quality and User Behavior Using PLS-MGA Methodology : An Institutional Perspective (PLS-MGA 방법론을 활용한 제도론적 관점에서의 공공제도 품질과 사용자 행태의 분석)

  • Lee, Jae Yul;Hwang, Seung-June
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.2
    • /
    • pp.78-91
    • /
    • 2017
  • In this study, we conducted a comparative study on user's perception and behavior on public system service (PSS) using institutionalism theory and MGA (multi-group analysis) methodology. In particular, this study focuses on how institutional isomorphism is applied to public system services and how MGA can be implemented correctly in a variance based SEM (structural equation model) such as PLS (partial least square). A data set of 496 effective responses was collected from pubic system users and an empirical research was conducted using three segmented models categorized by public proximity theory (public firms = 113, government contractors = 210, private contractors = 173). For rigorous group comparisons, each model was estimated by the same indicators and approaches. PLS-SEM was used in testing research hypotheses, followed by parametric and non-parametric PLS-MGA procedures in testing categorical moderation effects. This study applied novel procedures for testing composite measurement invariance prior to multi-group comparisons. The following main results and implications are drawn : 1) Partial measurement invariance was established. Multi-group analysis can be done by decomposed models although data can not be pooled for one integrated model. 2) Multi-group analysis using various approaches showed that proximity to public sphere moderated some hypothesized paths from quality dimensions to user satisfaction, which means that categorical moderating effects were partially supported. 3) Careful attention should be given to the selection of statistical test methods and the interpretation of the results of multi-group analysis, taking into account the different outcomes of the PLS-MGA test methods and the low statistical power of the moderating effect. It is necessary to use various methods such as comparing the difference in the path coefficient significance and the significance of the path coefficient difference between the groups. 4) Substantial differences in the perceptions and behaviors of PSS users existed according to proximity to public sphere, including the significance of path coefficients, mediation and categorical moderation effects. 5) The paper also provides detailed analysis and implication from a new institutional perspective. This study using a novel and appropriate methodology for performing group comparisons would be useful for researchers interested in comparative studies employing institutionalism theory and PLS-SEM multi-group analysis technique.

THE EFFECT OF NAOCL TREATMENT AND STERILIZATION PROCEDURES ON THE CORROSION OF ENDODONTIC FILES (차아염소산나트륨 처리와 멸균법이 근관 치료용 파일의 부식에 미치는 영향에 관한 연구)

  • Yang, Won-Kyung;Ra, Yoon-Sik;Lee , Young-Kyoo;Son, Ho-Hyun;Kim, Mi-Ri
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.121-127
    • /
    • 2005
  • A variety files made of stainless steel (S-S) or nickel-titanium (Ni-Ti) are used during endodontic treatment. The purpose of tt)is study was to evaluate the corrosion susceptibility of S-S and Ni-Ti endodontic files. Three brands of files were used for this study: $K-flex^{(R)}$ S-S files (Maillefer, USA), $Profile^{(R)}$ Ni-Ti files (Maillefer, USA), $K-3^{(R)}$ Ni-Ti files (SybronEndo. USA). 120 files of each brands (21mm, ISO size $\#20$) were divided into 12 groups according to 1) sterilization methods using Autoclave or Ethylene Oxide (E-O) gas, 2) Irrigation solutions using $5.25\%$ NaOCl or Saline, 3) the number of sterilization (1, 5, 10 times), After above procedures, each of the files was inspected by three examiners with a light microscope and camera at X25. Each file was judged and ranked according to the following criteria: 0;, no corrosion, 1; mild corrosion, 2; moderate corrosion, and 3; severe corrosion. The files of high score were examined under the Scanning Electron Microscope. Data were statistically analyzed with the Kruskal-Wallis test (p < 0.05). Most of the ten time-autoclaved files had showed mild to moderate corrosion. But, one or five time-autoclaved files did not show corrosive surface. NaOCl treatment and E-O gas sterilization did not influence on corrosion. There was a significant difference in corrosion susceptibility between sterilization methods and the number of autoclaving. However, there was no significant difference between brands and file materials.

Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods (다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교)

  • Hyuk-Joon Lee;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.2
    • /
    • pp.31-38
    • /
    • 2023
  • Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.

Comparison of WBCs and RBCs Concordance between the Cobas u 701 Analyzer and Three Manual Microscopy Methods in Urine Sediment (소변 침전물에서 Cobas u 701 Analyzer와 세 가지 수동 현미경검사법의 백혈구와 적혈구의 일치도 비교)

  • Hyeok-Jae LEE;Min-Hyeok LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.2
    • /
    • pp.82-92
    • /
    • 2023
  • Urine sediments are performed by a microscopic examination of centrifuged urine by medical technologists. This study examined different urine sediment preparation procedures. The 107 fresh urine specimens that tested positive from white blood cells (WBCs) and red blood cells (RBCs) in the urine dipstick test and the cobas u 701 analyzer, respectively, were selected for manual microscopy. This study evaluated an automated urine sediment analyzer and three manual microscopy methods for WBCs and RBCs. The methods were performed according to the test guidelines. The coefficients of determination between the cobas u 701 analyzer and the Korean Association of Quality Assurance for Clinical Laboratory (KAQACL) for WBCs and RBCs were r2=0.977 and r2=0.970, respectively. The concordance rates between the cobas u 701 analyzer and KAQACL for WBCs and RBCs were 74.8% and 77.6%, respectively. A good correlation and concordance with the automatic analyzer were shown when the specimens were prepared and examined using the KAQACL method. Consequently, the differences in the urine sediment preparation procedures affected the sediment concentrations, influencing the cell number per high power field (HPF).

Research on the Operation of Safeguards Equipment in Extreme Environmental Conditions (극한 환경 내 안전조치 장비 운영에 관한 연구)

  • Jiyoung Han;Suhui Park;Jewan Park;Yongmin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1189-1195
    • /
    • 2023
  • In scenarios involving inspections and verifications of nuclear facilities, ensuring the proper functioning of on-site safeguards equipment is crucial. There have been precedents in Kazakhstan where equipment failed to operate properly due to extremly cold temperatures, and the year-round minimum temperature at North Korea's Punggye-ri nuclear test site is approximately minus 30 degrees Celsius. To ensure the proper functioning of equipment in extreme environments for on-site verification of nuclear activities on the Korean Peninsula, relevant research is necessary. This includes confirming the functionality of equipment used in inspections and verifications, as well as analyzing factors that may disrupt their normal operation. This study aims to conduct a risk analysis for the normal operation of equipment in extreme environments and develop criteria and procedures for environmental-based performance testing. To achieve this, we conducted a risk analysis based on IAEA safeguards, analyzed the utilization of equipment, and performed a risk analysis associated with transportation for on-site verification considering the environmental characteristics of the Korean Peninsula. Furthermore, we provided performance testing criteria and procedures. The research results can be utilized as reference material in the verification and monitoring processes of nuclear activities.

Evaluation of Hydrogeological Characteristics of Deep-Depth Rock Aquifer in Volcanic Rock Area (화산암 지역 고심도 암반대수층 수리지질특성 평가)

  • Hangbok Lee;Chan Park;Junhyung Choi;Dae-Sung Cheon;Eui-Seob Park
    • Tunnel and Underground Space
    • /
    • v.34 no.3
    • /
    • pp.231-247
    • /
    • 2024
  • In the field of high-level radioactive waste disposal targeting deep rock environments, hydraulic characteristic information serves as the most important key factor in selecting relevant disposal sites, detailed design of disposal facilities, derivation of optimal construction plans, and safety evaluation during operation. Since various rock types are mixed and distributed in a small area in Korea, it is important to conduct preliminary work to analyze the hydrogeological characteristics of rock aquifers for various rock types and compile the resulting data into a database. In this paper, we obtained hydraulic conductivity data, which is the most representative field hydraulic characteristic of a high-depth volcanic bedrock aquifer, and also analyzed and evaluated the field data. To acquire field data, we used a high-performance hydraulic testing system developed in-house and applied standardized test methods and investigation procedures. In the process of hydraulic characteristic data analysis, hydraulic conductivity values were obtained for each depth, and the pattern of groundwater flow through permeable rock joints located in the test section was also evaluated. It is expected that the series of data acquisition methods, procedures, and analysis results proposed in this report can be used to build a database of hydraulic characteristics data for high-depth rock aquifers in Korea. In addition, it is expected that it will play a role in improving technical know-how to be applied to research on hydraulic characteristic according to various bedrock types in the future.

The Development and Effects of WEB Instruction Programs for Drug Abuse Prevention in Korean Adolescents (청소년의 약물남용예방을 위한 웹 활용 학습 프로그램 개발 및 효과)

  • Min, Young-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.4
    • /
    • pp.1055-1065
    • /
    • 2000
  • The purpose of this study was to develop, through the integration of instructional theory, a Courseware and to investigate the effectiveness of a web-based computer assisted instruction(WBI) program for preventing drug abuse, a serious problem for youth problem. During the first stage of this study done "Drug Abuse Prevention" Courseware was developed based on, Gagn & Brigg's instructional design theory, Keller's ARCS theory and the CAI model of Hannafin & Peck. For the second stage, the courseware was used to provide education for students adolescents in drug abuse prevention. This study used an quasi-experimental, one-group pretest-posttest design with a convenience sample of 36 male high school students who were at one high school located in Seoul. Data were collected using self-reported questionnaires which included a learning achievement tool, the Keller's IMMS (Instructional Material Motivation Survey), on attitudes to drug use, and on responses to the WBI instruction. Prior to the experiment, the "drug abuse prevention" learning method and the procedures of the study were explained to the students, and then the learning achievement of the subjects was measured as a pretest. The students were then given 2 weeks WBI utilizing the courseware. A post-test which included the pre-test learning achievement questionnaire and a survey of learning motivation and attitudes toward drug were given two weeks after the education was completed. The data analysis was done using SPSS/PC. Paired t-test was used to analyze the differences between the pre-test and post-test scores for learning achievement. The results of the analysis are as follows: There were significant differences in learning achievement between the pre-test and post-test(t=-18.62, p=0.000). The hypothesis, that learning achievement will be higher, after the class has used the courseware, than before was supported. The scores for learning motivation and attitudes toward drugs were also higher than the results of existing studies. In conclusion, this study suggests that WBI is an effective learning method in the prevention of drug abuse for adolescents as it can be used for self-learning and repeated learning as assisted instruction. Recommendation would be given that further research needs to be develped in the courseware by cognitive learning style and by multimedia courseware and virtual reality system.

  • PDF

Statistical Issues in the Articles Published in the Journal of Veterinary Clinics (한국임상수의학회지에 발표된 논문의 통계분석 검토)

  • Pak, Son-Il;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.2
    • /
    • pp.170-174
    • /
    • 2010
  • With the ease availability of statistical software and powerful computers the application of statistical methods in domestic veterinary journals is on the increase. In parallel with this benefit, statistical errors are not uncommon even in renowned scientific and medical journals. These errors may lead to misinterpretation of the data, thereby, subjected to faulty conclusions. A systematic review of articles published in 8 issues of the Journal of Veterinary Clinics during 2006-2007 was performed to assess the statistical methodology and reporting. Ninety-four (72.9%) articles of the 129 original articles screened included any inferential statistical analysis in the article, including comparison of 3 or more groups (53 or 56.4%), comparison of independent 2 groups (40 or 42.6%), and paired t-test (9 or 9.6%) in order. Of the 94 articles in which statistical analysis was done 62 (or 66.0%) had at least 1 statistical error. Errors included failure to apply or incorrectly applying independent Student's t-test for paired data or vice versa, inappropriate use of t-test for more than 3 groups and failure in chi-square test to consider continuity-correction for small expected frequencies. The common errors in ANOVA were failure to validate assumption of the test, inappropriate post-hoc multiple-comparison and incorrect assumption of independence of data in repeated measures design. Reporting errors included failure to state statistical methods and failure to state specific test if more than 1 test was done. It is suggested that an editorial effort would be necessary to achieve the improvement of appropriate statistical procedures through the publication of statistical guidelines to author(s).

Effect of different adhesive systems and post surface treatments on the push-out bond strengths of fiber-reinforced post (다양한 접착 시스템 및 포스트의 표면 처리가 섬유 강화 포스트의 접착 강도에 미치는 영향)

  • Kim, Min-Woo;Ahn, Jin-Hee;Kim, Lee-Kyoung;Shim, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.218-225
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the push-out bond strength of glass-fiber post cemented with different adhesive systems and surface treatments. Materials and methods: 160 tooth samples made from 48 human maxillary single-rooted teeth with similar root length were divided into 4 groups according to the adhesive system (no adhesive, Adper Single Bond 2, Clearfil SE Bond, Clearfil S3). Each group had 4 subgroups according to the post surface treatment methods (no treatment, sandblast, silane, sandblast and silane). Posts (Parapost Fiber White) were cemented with Rely X Unicem. The teeth were sectioned perpendicular to their long axis into 1-mm thick sections. The push-out tests was performed at a speed of 0.5 mm/min. The results were evaluated by 2-way ANOVA, 1-way ANOVA and multiple comparison procedures (Tukey test) (${\alpha}=0.05$). Results: Tukey test showed that the adhesive system significantly influenced the push-out strength. The Clearfil SE Bond group showed the highest value. Post surface treatments showed no significant effect. Conclusion: Bond strength of glass-fiber post cemented with self-adhesive resin cement using Clearfil SE Bond showed significantly higher values compared to other adhesive systems.