• Title/Summary/Keyword: Test procedures

Search Result 1,857, Processing Time 0.033 seconds

Geotomography Applied for the Integrity Test of Cast-in-place Piles (현장타설콘크리트말뚝의 건전도 평가를 위한 geotomography의 적용 연구)

  • Lee Jae-Kyung;Park Jong-Nam
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.4
    • /
    • pp.5-12
    • /
    • 2005
  • Recently, geophysical prospecting methods have played very important roles in civil and environmental engineering problems. Technical advances in geophysical instruments and computer system made it possible to get underground images with very high resolution far purposes to resolve those problems. It was possible partly due to ever increasing demand for development of technologies needed to precisely detect polluted areas and prevent ground-related accidents. Based on the same demand, integrity tests of cast-in place piles draw more attention and development of accurate test procedures is required. Ultrasonic methods is one of most advanced non-destructive procedures. In the paper, a geotomography method is employed for the cast-in place pile integrity test using ultrasonic waves. The image of pile interior is scanned and scrutinized far better and more accurate decision in the cast-in place pile integrity. In this study, we firstly examined the accuracy fur tomography program with idealized synthetic models built in water tank: their position and size were changed in the tank and each case was studied. In the next stage, real concrete pile models were fabricated and images of anomaly areas inside the pile were scanned to successfully locate those areas.

A Rapid Serotyping of Hydrophobic Strains of Mycobacterium acrofulaceum by Fluorescent Anti-Complement Technique (형광항보체법(螢光抗補體법)에 의한 Mycobacterium scrofulaceum 소수성균주(疏水性菌株)의 형별동정(型別同定))

  • Choi, Chul-Soon;Kim, Yong-Jae;Yang, Yong-Tae
    • The Journal of the Korean Society for Microbiology
    • /
    • v.15 no.1
    • /
    • pp.9-17
    • /
    • 1980
  • In the ecology and epidemiologic studies on various serotypes of atypical mycobacteria(AM), Schaefer's bacterial agglutination test(BA) provided the basis of the serologic procedures. Recently, attempts have been made to modify and to simplify the Schaefer's BA such as a slide agglutination test(Engel & Beerwald, 1970), a "simplified" BA(Reznikov & Leggo, 1972), an agglutination inhibition test(Richards & Eacret, 1972) and "micromethod"(Thoen et al., 1975). The BA, however, was not widely applied as a routine laboratory test mainly because it requires much times and labors to perform and partley because it is not applicable to hydrophobic strains either often encountered in the isolation of AM in the clinical bacteriology or stock strains maintained in the laboratory. On the contrary, fluorescent antibody technique with mycobacteria may have advantages over the BA because it is far more simpler in serologic procedures and is applicable to all strains of mycobacteria regardless of smooth or rough types of cultures. At the present, it is well known that the type-specific antigens are lacking on the surface of rough type of AM compared to that on smooth type of strain, but the antigenicity on the surface of the hydrophobic strains of AM which resulted from a series of subculture and the strain in the laboratory for 3 to 6 months has not been clarified. In this study, an attempt to serotype the hydrophobic strains of M. scrofulaceum serotype 41, 42 and 43 by fluorescent anti-complement(FAC) technique was made. The FAC technique with mycobacteria was also described in detail. In the summary, the complement fixing antibody titres of reference sera to smooth types of homologous serotype was highest, but the antibody titres of reference sera to hydrophobic strains of serotypes, 41, 42 and 43 gave two-to 8-folds lower than those to smooth type of strains. Although the sensitivity of type-specific antigens on the hydrophobic strains to reference sera was much lower, using the two units of reference sera determined by titration with hydrophobic strains, three serotypes, i. e., 41, 42 and 43 were specifically differentiated one another by FAC technique. This result indicated that the hydrophobic strains which were maintained in the laboratory at least for 6 months still retain type-specific antigen detectable by FAC technique.

  • PDF

A Study on Standardization of Test Method for Water Vapour Permeability of Textiles Fabrics (군용 피복류의 투습도 시험방법 표준화 연구)

  • Lee, Min-Hee;Hong, Seong-Don;Chung, Il-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.27-33
    • /
    • 2016
  • Military textiles with breathable waterproof materials are expanding as form of winter clothes. Waterproof moisture-permeable clothes are very important for soldiers to survive in cold weather operations because they prevent loss of body heat from the penetration of water into the human body. Korea military uses the water resistance and moisture permeability to test the performance of waterproof moisture-permeable materials. Moisture permeability is measured according to the amount of evaporated water vapor passing through a fabric under specified temperature and humidity by using acetic acid potassium presented in KS K 0594. However, the test procedure for measuring the moisture permeability in the standard is presented only briefly and the preparation procedures for the test in accredited testing institutions are applied differently, leading to significant deviation of the results. This paper compares the procedures of testing institutions and examines the factors that affect moisture permeability. Finally, we propose a procedure to reduce the deviation of results and apply the proposed procedure in testing institutions. Our analysis results with one-way ANOVA under significant level (0.05) confirm that the deviation of results is reduced.

Flight Test Measurement and Assessment of a Flapping Micro Air Vehicle

  • Kim, Jong-Heon;Park, Chan-Yik;Jun, Seung-Moon;Chung, Dae-Keun;Kim, Jong-Rok;Hwang, Hee-Chul;Stanford, Bret;Beran, Philip;Parker, Gregory;Mrozinski, Denny
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.238-249
    • /
    • 2012
  • Flight test of flapping micro air vehicles (FMAVs) is carried out using an instrumented measurement system to obtain various engineering parameters and hence to assess the flight performance of the vehicles through the data investigation. An indoor flight test facility equipped with a motion capture system and tracking cameras is used for the work presented in this paper. Maneuvers including straight-level flight, ground flapping, takeoff and landing are tested. Spatial position and orientation data are obtained from the retro-reflective tracking markers attached to the vehicles. Subsequent test analysis is carried out by generating performance parameters from raw data and then assessing the flight performance by comparison of the vehicles. The main findings of this work confirm that the test method and procedures presented here enable the systematic numerical data measurement and assessment of the flying performances of these vehicles, and show the applicability for the test and evaluation of general flapping MAVs.

Newborn screening of inherited metabolic disease in Korea (유전성 대사질환의 신생아 스크리닝)

  • Lee, Dong Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1125-1139
    • /
    • 2006
  • In 1991, the Ministry of Health & Social affairs adopted a nationwide service program for neonatal screening of phenylketonuria, galactosemia, maple syrup urine disease, homocystinuria, histidinemia & congenital hypothyroidism for newborns delivered from low class pregnant women registered in health centers. Government decreased the test items from six to two, PKU & congenital hypothyroidism to increase test numbers with same budget from 1995. Government decided to test PKU & hypothyroidism for all newborns from 1997. 78 laboratories wanted to participate for neonatal screening test in 1999. Government didn't decide laboratory center for a certain district and placed responsibility on free competition. Government are planning to test 573,000 newborns from 1998, Government decided to screen 6 items PKU, congenital hypothyroidism, maple syrup urine disese, homocystinuria, galactosemia and congenital adrenal hyperplasia from 2006. 17 laboratores are participating now. The cost of screening test is supported by both the federal government and local government on a 40-60 basis. In case a patient with an inherited metabolic disease is diagnosed by screening of government program, special milk is provided at government's expense. Interlaboratory quality control was started 6 times a year from 1994. According to the government project, 3,707,773 newborns were screened. 86 PKU, 718 congenital hypothyroidism were detected. So incidence of PKU is 1/43,114 and congenital hypothyroidism is 1/4,612. Maeil dairy company produced new special formula for PKU, MMA and PA, MSUD, urea cycle disorder, homocystinuria, isovaleric acidemia from Oct. 1999. The cost benefit of performing screening procedures coupled with treatment has been estimated to be as high as 1.77 times in PKU, 11.11 times in congenital hypothyroidism than cost without screening. We are trying to increase the budget to test all newborns for Tandem mass sereening & Wilson disease from 2008. Now it is a very important problem to decrease laboratory numbers of neonatal screening in Korea. So we are considering 4-5 central laboratories which cover all newborns and are equipped with tandem mass spectrometer & enzyme immunoassay for TSH, 17OHP & enzyme colorimetric assay for galactose.

Laboratory Tests for the Applicability of Various Testing Devices for Measuring Degree of Compaction (여러가지 다짐 평가장비의 적용성을 위한 실내시험)

  • Yoo, Wan-Kyu;Lim, Nam-Gyu;Kim, Byoung-Il;Kim, Ju-Hyong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1178-1187
    • /
    • 2008
  • Quality assurance for embankment compaction is one of very important procedures to guarantee high quality construction. However, only sand replacement method (KS F2312) and static plate load test (KS F2310) which are conventional and tiresome methods are used to evaluate degree of compaction at construction fields. Recently, new types of devices such as the geogauge and the light falling weight deflectometer (LFWD), the soil impact hammer (CASPFOL) and dynamic cone penetration test etc. which are able to substitute for the conventional methods are begun to use to evaluate soil stiffness. In this study, a laboratory model test was performed to evaluate correlations among test results obtained from the new devices and to assess the potential use of them. All test results have correlations with relative density and water content. Especially, the coefficients of correlation between $E_G$ from the geogauge and $K_{30'}$ from the soil impact hammer and between $E_G$ from the geogauge and $E_{LFWD}$ from LFWD are more than 0.7 but those between the results from DCP and others are less than those between $E_{G{\cdot}}$ and $K_{30'}$ and $E_G$ and $E_{LFWD}$.

  • PDF

Development of the Scientific Creative Problem Solving Test for the Selection of Gifted Science Students in Elementary School (초등학교 과학영재학급 학생선발을 위한 과학 창의적 문제해결력 검사도구 개발)

  • Choi, Sun-Young;Kang, Ho-Kam
    • Journal of Korean Elementary Science Education
    • /
    • v.25 no.1
    • /
    • pp.27-38
    • /
    • 2006
  • The purpose of this study was to develop a test of a creative problem solving (CPS) for the selection of gifted science students in elementary school. For this, the methods and procedures of the selection of gifted science students was investigated through the internet homepages 23 gifted science education centers of universities and 16 city. province offices of education. The results of this study were as follows: Most of the gifted science students were selected through a multi-step examination process. They were selected on the basis of their records by recommendation of a principal or a classroom teacher in their school, by operation of standardized tests (ex. intelligence quotient score, achievements in science and mathematics, interest and attitude/aptitude for science as well as through other means), as well as through intensive observation of those gifted science students who are selected by interview and oral tests. The selection of gifted students was not evaluated through creativity testing; giftedness in city. province office of education. Testing of CPS was found to be especially lacking in these organizations. For the development of the test items of CPS in science, the five elements were extracted through the framework for the content analysis of the CPS: problem exploration, problem statement, solution thinking, experiment design, and assesment. In addition, suggestions were made regarding an appropriate scoring system for the test of the CPS. As the result of the developed test was applied to the 4th grade of the gifted and general student, we found that gifted students were superior to general students. In conclusion, it was that the CPS test developed in this study should be used to evaluate the CPS for the selection of gifted students.

  • PDF

Resilient Modulus Test of Subgrade Soils Using Standard Triaxial Test Equipment (표준 삼축압축 시험기를 이용한 노상토의 회복탄성계수 시험법)

  • Woo, Je Yoon;Cho, Chun Whan;Moon, Hong Deug;Kim, Dong Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.239-250
    • /
    • 1993
  • The dynamic resilient modulus tests to determine the $M_R$ of the soils require expensive equipments and well trained personnels to obtain reliable test results. These problems inherent in the dynamic resilient modulus testing have been realized as major negative factors to hinder the $M_R$ test from being practically implemented as a routine test. In this regard. it is highly desirable to develop a simpler alternative testing method incorporating inexpensive equipments and easy-to-perform testing procedures. Developed in this study is an alternative $M_R$ test method based on statically repeated loading scheme utilizing the standard static triaxial test equipments. Applicability and limitations of the developed static $M_R$ testing method are investigated for typical subgrade soils in Korea.

  • PDF

Synthesis and Anticonvulsant Evaluation of $N-Cbz-\alpha-amino-N-alkoxysuccinimides$

  • Byun, Aseun;Kim, Min-Jeong;Park, Jong-Won;Moon, Kyung-Ho;Lee, Chung-Kyu;Park, Min-Soo
    • Archives of Pharmacal Research
    • /
    • v.27 no.3
    • /
    • pp.273-277
    • /
    • 2004
  • In previous studies for the development of new anticonvulsants, we found that N-Cbz-$\alpha$-amino-N-alkylsuccinimides exhibited significant anticonvulsant activities in the Maximal electroshock seizure (MES) and Pentylenetetrazole induced seizure (PTZ) tests, and also their anticonvulsant activities were dependent on the N-alkyl substituents existent in their structures. Based on these estimations, N-Cbz-$\alpha$-amino-N-hydroxysuccinimide and various N-Cbz-$\alpha$-amino-N-alkoxysuccinimides were prepared in order to develop more active anticonvulsants and to examine the effects of N-hydoxy or N-alkoxy groups on their anticonvulsant activities. The (R)-or (S)-N-Cbz-$\alpha$-amino-N-hydroxysuccinimide and N-Cbz-$\alpha$-amino-N-alkoxysuccinimides were prepared from the corresponding (R)-or (S)-N-Cbz-aspartic acid through the known synthetic procedures. Their anticonvulsant activities in the MES and PTZ test were evaluated. All of these compounds except 3a showed significant anticonvulsant activities against the PTZ test, but these compounds were not active in the MES test. The most active compound in the PTZ test was (R)-N-Cbz-$\alpha$-amino-N-benzyloxysuccinimide (ED$_{50}$=62.5 mg/kg). In addition, the anti-convulsant activities of these compounds were dependent on their N-substited groups. The order of anticonvulsant activity against the PTZ test, as judged from the ED50 values for (R) series was N-benzyloxy > N-hydroxy > N-isopropoxy > N-methoxy > N-ethoxy; for the (S) series N-ethoxy > N-benzyloxy > N-methoxy > N-isopropoxy.y.

Evaluation of Asphalt Emulsions Curing and Adhesive Behavior used in Asphalt Pavement Preservation (Surface Treatments) (아스팔트 도로포장 유지보수(표면처리)용 유화아스팔트의 양생 및 점착거동특성 평가)

  • Im, Jeong Hyuk;Kim, Y. Richard
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.39-50
    • /
    • 2014
  • PURPOSES : The objective of this study is to evaluate the curing and adhesive behavior of asphalt emulsions including polymer-modified emulsions for chip seals and fog seals. METHODS : For the laboratory testing, the evaporation test, the bitumen bond strength (BBS) test, and the Vialit test are used. Also, the rolling ball test and the damping test are employed to evaluate the curing properties of the fog seal emulsions. In order to conduct all the tests in controled condition, all test procedures are performed in the environmental chamber. The CRS-2L and the SBS CRS-2P emulsions are used as a polymer-modified emulsion, and then unmodified emulsion, the CRS-2, is compared for the evaluation of chip seal performance. For the fog seal performance evaluation, two types of polymer-modified emulsions (FPME-1 and FPME-2) and one of unmodified emulsion, the CSS-1H, are employed. All the tests are performed at different curing times and temperatures. RESULTS AND CONCLUSIONS : Overall, PMEs show better curing and adhesive behavior than non-PMEs regardless of treatments types. Especially, the curing and adhesive behavior of PMEs is much better than non-PMEs before 120 minutes of curing time. Since all the test results indicate that after 120 minutes of curing time the curing adhesive behavior of emulsions, the early curing time, i.e., 120 minutes, plays an important role in the performance of chip seals and fog seals.