• Title/Summary/Keyword: Test procedures

Search Result 1,857, Processing Time 0.031 seconds

Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior (ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구)

  • Kim, Young-Ho;Lee, Yong-Soo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.

A Study on Doping Test of Bojungchisheup-tang (보중치습탕(補中治濕湯)의 도핑검사 대상약물(對象藥物)에 관(關)한 연구(硏究))

  • Kim, Sung-Yong;Geum, Dong-Ho;Lee, Myeong-Jong
    • Korean Journal of Oriental Medicine
    • /
    • v.3 no.1
    • /
    • pp.289-319
    • /
    • 1997
  • Non-medical use of drugs to enhance performance at Olympic Games by athletes has been prohibited by the International Olympic Committee(IOC) since 1968 on medical and ethical grounds. IOC wants to protect athlete from harmful side effect of drugs due to misuse of it. It also, ethically, wants to have Games run on fair base, not fortified by performance enhancing drugs, The banned substances include stimulants, narcotic analgesics, anabolic sterolds, ${\beta}-blockers$ and diuretics. In order to prevent the positive reaction in the doping test induced by herb medicine, this study was done on about Bojungchisheup-tang. The laboratory set up doping analyses methods to cover as many drugs as possible without sacrificing sensitivity and specificity within one procedure. Its screening method consisted of four different procedures. The results were negative. According to the above results, Bojungchisheup-tang taken by athletes would show the negative reaction in the doping test. So its prescription for athletes can be given without worries of the doping test.

  • PDF

Parameter Estimation of a Small-Scale Unmanned Helicopter by Automated Flight Test Method (자동화 비행시험기법에 의한 소형 무인헬리콥터의 파라메터 추정)

  • Bang, Keuk-Hee;Kim, Nak-Wan;Hong, Chang-Ho;Suk, Jin-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.9
    • /
    • pp.916-924
    • /
    • 2008
  • In this paper dynamic modeling parameters were estimated using a frequency domain estimation method. A systematic flight test method was employed using preprogrammed multistep excitation of the swashplate control input. In addition when one axis is excited, the autopilot is engaged in the other axis, thereby obtaining high-quality flight data. A dynamic model was derived for a small scale unmanned helicopter (CNUHELI-020, developed by Chungnam National University) equipped with a Bell-Hiller stabilizer bar. Six degree of freedom equations of motion were derived using the total forces and moments acting on the small scale helicopter. The dynamics of the main rotor is simplified by the first order tip-path plane, and the aerodynamic effects of fuselage, tail rotor, engine, and horizontal/vertical stabilizer were considered. Trim analysis and linearized model were used as a basic model for the parameter estimation. Doublet and multistep inputs are used to excite dynamic motions of the helicopter. The system and input matrices were estimated in the frequency domain using the equation error method in order to match the data of flight test with those of the dynamic modeling. The dynamic modeling and the flight test show similar time responses, which validates the consequence of analytic modeling and the procedures of parameter estimation.

Efficient Test Generation using Critical-Pair Path in FFR (FFR에서의 임계-쌍 경로를 이용한 효율적인 테스트 생성)

  • 서성환;안광선
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.4
    • /
    • pp.1-16
    • /
    • 1999
  • Critical is used frequently in many test generation procedures. In this paper, the critical-pair is defined as a extended concept of critical. Also, the criticality, the critical rate, the critical number, and the critical setting rate are defined which represent the characteristics of critical. In these elements, it is proved that the usage of the critical-pair is more efficient than that of the single critical. in FFR, it is also showed that the critical-pair is more efficient in evaluation number of critical values when the test pattern is generated, in the number of searching lines, and the test generation time. The experimental results of the critical-pair on the ISCAS85 benchmark test circuits are compared and analyzed to the single critical using simulation.

  • PDF

AN EXPERIMENTAL STUDY ON PHYSICAL PROPERTIES OF WROUGHT WIRE CLASP (WROUGHT WIRE CLASP의 물리적 성질에 관한 실험적 연구)

  • Lee, Kwang-Hee;Chang, Ik-Tae;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.201-218
    • /
    • 1989
  • The purpose of this study was to evaluate the influence of attachment technique on mechanical properties and microstructures of wrought wires. The wires tested in this study were precious metal wires: PGP (Platinum-Gold -Palladium), Elastic #12, Denture Clasp, Standard, Jelenko No. 2, Degulor-Klammerdraht, DM (Dong Myung) and base metal wire : Ticonium. Each wire was divided into three groups, and each group was heat treated as embedding, cast to, and soldering state. Heat treated sample was evaluated by tensile test, bending test, microhardness test, element analysis and microstructure test. The obtained results were as follows: 1. In tensile test, cast to and soldering procedures have an effect on wrought wire clasp as hardening heat treatment. 2. Maximum bending strength was significantly increased in Elastic #12, Denture Clasp, Standard, and DM in cast to procedure. 3. Ticonium showed the highest Victors hardness number, followed by PGP, and there was no significant difference in other wrought wires. In cast to and soldering procedure, Victors hardness number was significantly increased in precious wrought wires. 4. The precious wrought wire showed typical fibrous structure and this was disappeared in cast to and soldering procedure. But physical properties were not influenced by this phenomenon.

  • PDF

A Study on the Model Updating Procedures Using Modal Frequencies (모드 주파수를 이용한 모델 개선 과정에 대한 연구)

  • Jang, In-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.109-116
    • /
    • 2010
  • It is important to make a mechanical structure precisely and reasonably in predicting the dynamic characteristics, controlling the vibration, and designing the structure dynamics. In finite element analysis model updating is appropriate as the design parameter is used to analyze the dynamic system. The errors can be contained from the physical parameters and the element modeling. From the dynamic test, more precise dynamic characteristics can be obtained. In this paper, model updating algorithm is developed using frequency difference between experiment and calculation. Modal frequencies are obtained by experiment and finite element analysis for beams with various cross section and shapes which have added masses and holes in the middle. For plates with and without groove, experiment and analyses are carried out by applying free boundary conditions as well. Mass and stiffness matrices are updated by comparing test and analytical modal frequencies. The result shows that the updated frequencies become closer to the test frequencies in case that both matrices are updated. An improved analytical model is obtained by changing model parameters such that the discrepancy between test and finite element frequencies is minimized. For beam and plate models updating of mass and stiffness matrices can improve the dynamical behavior of the model by acting on the physical parameters such as masses and stiffness.

A Test on a Specific Set of Outlier Candidates in a Linear Model (선형모형에서 특정 이상치 후보군에 대한 검정)

  • Seo, Han Son;Yoon, Min
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.2
    • /
    • pp.307-315
    • /
    • 2014
  • An exact distribution of the test statistic to test for multiple outlier candidates does not generally exist; therefore, tests of individual outliers (or tests using simulated critical-values) are usually conducted instead of testing for groups of outliers. This article is on procedures to test outlying observations. We suggest a method that can be applied to arbitrary observations or multiple outlier candidates detected by an outlier detecting method. A Monte Carlo study performance is used to compare the proposed method with others.

The Evaluation of Distance Accuracy and The Test Target Manufacturing of A Terrestrial Laser Scanner (TLS용 테스트 타깃의 개발과 거리측정 정확도 검증)

  • Lee, In-Su;Tcha, Dek-Kie;Suh, Ho-Suhng
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.3
    • /
    • pp.279-285
    • /
    • 2012
  • Albeit the use of terrestrial 3D laser scanner (TLS) in the parts of landslide monitoring, cultural heritage documentation, civil engineering, urban engineering, etc. is increasing more and more, there is no international standardization regulation about the accuracy evaluation of the geometric element values, target, instrument calibration and test procedures, etc. Accordingly, this study deals with the manufacturing of TLS performance test target and the evaluation of TLS distance measurement and shows its suitability as the test target.

Intercomparison of Light Oil Flow Standard System for the Reliability of Measurement Accuracy (경질유 유량표준장치의 신뢰도 검증을 위한 측정정확도 비교)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.9
    • /
    • pp.712-719
    • /
    • 2008
  • Light Oil Flow Standard System(LOFSS), as a national oil flow standard system, in Korea Research Institute of Standards and Science(KRISS) was developed for oil flowmeter calibration, and the expanded uncertainty of flow quantity determination was estimated within 0.04 %. In order to improve the reliability of the LOFSS measurement, a proficiency test was carried out in the flow range of 20 and $240\;m^3/h$ (Reynolds number $20,000{\sim}900,000$). A turbine flowmeter was used as a transfer package in round robin test. The water flow standard system of KRISS, the pipe prover of the national calibration and test organization and the master meter calibrator of the turbine flowmeter supplier, which used the different working fluid respectively, were compared with the turbine flowmeter measurement. The maximum difference of measurement was 0.15 % between the LOFSS and the pipe prover. The En numbers of the each system measurement were evaluated at the same Reynolds number. It was found that the En numbers were less than 1 in the comparison, which means the procedures of the uncertainty estimation of the each calibrators were reasonable and reliable.

Correlation of single leg vertical jump, single leg hop, and single leg squat distances in healthy persons

  • Shin, Seung-Ho;Woo, Hyunjae
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.57-61
    • /
    • 2013
  • Objective: To determine the correlation among three functional tests: single leg vertical jump (SLVJ), single leg hop for distance (SLHD), and single leg squat (SLSQ). Design: Cross sectional study. Methods: Twenty healthy men (n=10) and women (n=10) with no history of lower extremity dysfucntion participated in this study and performed in university research laboratory. The procedures consisted of a general warm-up, a task-specific warm-up, actual testing, and a cool down. All participants performed the three tests in random order. Each test was performed three times for the dominant and non-dominant lower extremity (LE). SLVJ, SLHD, SLSQ were measured using a standard tape measure. Results: Statistically significant difference was presented between dominant LE and non-dominant LE in each function test (p<0.05). The strongest correlation was between SLVJ and SLSQ, 0.939 and 0.883 for dominant and non-dominant LE, respectively (p<0.05). The weakest correlation was between SLVJ and SLHD, 0.713 for dominant (p<0.05) and between SLSQ and SLHD, 0.739 for non-dominant (p<0.05). Conclusions: There is a strong correlation between SLVJ and SLSQ, suggesting that each test measures similar constructs of function and can be substitutive, while weak correlation between SLSQ and SLHD suggest these two tests do not measure the same functional components and could be paired as outcome measures for the clinical assessment of LE function. It will provide physical therapist with scientific evidence for effective test combination of LE function assessment in clinical practice.

  • PDF