• Title/Summary/Keyword: Test procedures

Search Result 1,862, Processing Time 0.027 seconds

Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Frequency Spectrum Analysis Method (주파수분석법에 의한 발전소 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk;Lee, In-Cheol;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.10-17
    • /
    • 2000
  • In boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants, conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also, these techniques have low practicality and applied only to component surfaces with good accessibility. It needs to apply a reliable and quantitative ultrasonic nondestructive evaluation method that can be replaced for these equipment. In this study, both artificial creep degradation test using life prediction formula and frequency analysis by ultrasonic tests for crept specimens were carried out for the purpose of nondestructive evaluation for creep damage. As a result of ultrasonic tests for crept specimens, we conformed that the high frequency side spectra decrease and central frequency components shift to low frequency band, and also their bandwidth decreases as increasing creep damage in backwall echos.

  • PDF

Practical Considerations for Perforator Flap Thinning Procedures Revisited

  • Prasetyono, Theddeus O.H.;Bangun, Kristaninta;Buchari, Frank B.;Rezkini, Putri
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.693-701
    • /
    • 2014
  • Background A thin perforator flap is one of the best methods for covering defects. This study aimed to revisit and further test the rapidly advancing field of flap thinning techniques. Methods We performed two cadaveric studies to test the known flap thinning methods, and then applied these methods to a clinical series. In the first study, five cadavers were used to observe the anatomical relation of the perforator with the subdermal plexuses and the subcutaneous fat layer by injecting a colored latex solution. The second study was done on four cadavers independently from the first study. Last, a clinical series was performed on 15 patients. Results The areolar fat lobules of 10 anterolateral thigh perforator (ALT), seven deep inferior epigastric artery perforator (DIEAP), and six thoracodorsal artery perforator (TAP) flaps were dissected to reduce the flap thickness guided by the colored vascular pattern. On average, the ALT, DIEAP, and TAP flaps were reduced to $32.76%{\pm}9.76%$, $37.01%{\pm}9.21%$, and $35.42%{\pm}9.41%$, respectively. In the second study, the areolar fat lobules were directly dissected in six ALT, six TAP, and four MSAP flaps, and an average reduction in flap thickness of $53.41%{\pm}5.64%$, $52.30%{\pm}2.88%$, and $47.87%{\pm}6.41%$, respectively, was found. In the clinical series, 13 out of the 15 cases yielded satisfactory outcomes with an average thickness reduction of $37.91%{\pm}7.15%$. Conclusions These multiple studies showed that the deep fat layer could be safely removed to obtain a thin yet viable perforator flap. This evidence suggests that the macroscopic flap thinning technique can achieve thin flaps. Surgeons should consider this technique before embracing the latest technique of supermicrosurgery.

A Study on the Fatigue and Health Promoting Behavior of Public Health Nurses and Hospital Nurses (임상간호사와 보건간호사의 피로와 건강증진행위에 대한 연구)

  • Kim, Sun-Ok;So, Hee-Young;Kim, Hyun-Li
    • Research in Community and Public Health Nursing
    • /
    • v.14 no.4
    • /
    • pp.699-706
    • /
    • 2003
  • The objective of this study is to find out the difference in perceptional fatigue and health promoting behavior between hospital nurses and public health nurses. The subjects of this study were 141 hospital nurses and 73 public health nurses in Daejeon. Data were collected using a self-reporting questionnaire during the period from the 5th to 16th of March 2003. Collected data were analyzed using SPSS program. Real number, percentage, mean and standard deviation were calculated, and $x^2$-test and t-test, ANOVA, Pearson's correlation coefficient, stepwise multiple regression procedures were carried out. The findings of this study as follows: 1. The mean score of health promoting behavior was 2.71. 2. There were statistically significant differences in health promoting behavior according to age, marital status, family status, residency, educational level, income, the length of work experience and the field of work. (p<0.05) 3. There were statistically significant differences in fatigue according to age, marital status, family status, educational level, income, the length of work experience, perceived health status and the field of work. (p<0.05) 4. The fatigue was found to be in significant negative correlations with health promoting (r=-0.358, p<0.000) and self efficacy (r=-0.314, p<0.000). On the contrary, a significant positive correlation was found between fatigue and perceived barriers (r=0.210, p<00.01). 5. There were five predictors affecting health promoting behavior, which were self-efficacy, income, perceived benefit, fatigue and family support. The most influential factor was self-efficacy that made 31% of prediction, followed by income (6%), perceived benefit (5.2%), fatigue (2.2%) and family support (1.7%) in their order. As a whole, these factors made 46.1% of prediction of health promotion behavior.

  • PDF

The relationship between a cognitive styles and a technological problem solving among the industrial high school students (공업계 고등학교 학생의 장독립·장의존 인지양식과 기술적 문제해결과의 관계)

  • Lee, Chang-Hoon;Kim, Ki-Soo
    • 대한공업교육학회지
    • /
    • v.30 no.1
    • /
    • pp.46-55
    • /
    • 2005
  • The purpose of this study is to contemplate the relationship between a cognitive styles(field-independence/dependence, Fl/D)and a technological problem solving(TPS) among the industrial high school students. When it comes to perception, remembrance and consideration, we all have our own individual and steady patterns. We call them cognitive styles. FI/D is one kind of cognitive styles and it is about how dependently we perceive the field which each object has. Custer(1995) presented the technological problem among problem solving existed in various types as organizing it with four conceptional frames, which are invention, design, trouble shooting and procedures. We tested 56students belong to B industrial high school in A city, Korea. We used Group Embedded Figures Test(GEFT) to experiment the FI/D cognitive styles. We also did the TPS test by using an appliance which a researcher has developed. The appliance was made according to the technological problem and its validity was justified by an expert. We came up with a correlation coefficient between the FI/D cognitive styles and TPS to figure out what kind of relationship those two variable factors have and how much they are correlated each other. The correlation coefficient turned out ".59" which means they have significant and positive correlation.To find out the TPS difference between FI group and FD group, we compared each group's TPS score. As a result of the analysis, the FI group's TPS score is significantly higher than FD group's one.

Geometric Errors Estimation of a Rotary Table using Double Ball-bar (볼바를 사용한 회전 테이블의 기하학적 오차 추정)

  • Lee, Kwang-Il;Lee, Dong-Mok;Kweon, Sung-Hwan;Yang, Seung-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.98-105
    • /
    • 2010
  • In this paper, double ball-bar is used to estimate the geometric errors of a rotary table, which includes one-axial motion, two-radial motions and two-tilt motions, except the angular positioning error. To simplify the measurement procedures, three measurement steps have been designed and developed. At each measurement step, one end of the double ball-bar is fixed at the nose of spindle and the other end is located on the rotary table. And specific circular test path is planned to keep the distance between two balls as constant at ideal case. The relationship including the geometric errors of a rotary table and the measured distance between two balls which is distorted by the geometric errors is defined by using ball-bar equation. Each geometric error is modeled as $4^{th}$ order polynomial considering $C^1$-continuity. Finally the coefficients of polynomial are calculated by least-square method. Simulation is done to check the validation of the suggested method considering set-up errors and measurement noise. Suggested method is applied to estimate geometric errors of a rotary table of a 5-axis machine tool.

Bond Strength Evaluation of Asphalt Emulsions used in Asphalt Surface Treatments (아스팔트포장의 표면처리에 사용되는 유화아스팔트의 접착력 특성 평가)

  • Im, Jeong Hyuk;Kim, Y. Richard;Yang, Sung Lin
    • International Journal of Highway Engineering
    • /
    • v.16 no.5
    • /
    • pp.1-8
    • /
    • 2014
  • PURPOSES : The objective of this study is to evaluate the bond strength of asphalt emulsions including polymer-modified emulsions for chip seals and fog seals using the bitumen bond strength (BBS) test. METHODS : For the laboratory testing, the Pneumatic Adhesion tensile Testing Instrument(PATTI) device is used to measure the bond strength between the asphalt emulsion and aggregate substrate based on the AASHTO TP-91. In order to conduct all the tests in controled condition, all test procedures are performed in the environmental chamber. The CRS-2L and the SBS CRS-2P emulsions are used as a polymer-modified emulsion, and then unmodified emulsion, the CRS-2, is compared for the evaluation of chip seal performance. For the fog seal performance evaluation, two types of polymer-modified emulsions and one of unmodified emulsion, the CSS-1H, are employed. For chip seal study, the BBS tests are performed at 30, 60, 120, and 240 minutes of curing times with curing and testing temperatures of $15^{\circ}C$, $25^{\circ}C$, and $35^{\circ}C$. The fog seal tests are conducted at 30, 60, 90, 120, 180 minutes, and 24 hours with curing and testing temperatures of $25^{\circ}C$, $30^{\circ}C$, and $35^{\circ}C$. RESULTS AND CONCLUSIONS : Overall, chip seal emulsions and fog seal emulsions show the similar bond strength trend. At the same testing condition, polymer-modified emulsions show better bond strength than unmodified emulsions. Also, there is no significant difference between polymer-modified emulsions. One of important findings is that the most bond strength reaches their final bond strength within one hour of curing time. Therefore, the early curing time plays a vital role in the performance of chip seals and fog seals.

Automatic Processing Techniques of Rotorcraft Flight Data Using Data Mining (회전익항공기 운동모델 개발을 위한 데이터마이닝을 이용한 비행데이터 자동 처리 기법)

  • Oh, Hyeju;Jo, Sungbeom;Choi, Keeyoung;Roh, Eun-Jung;Kang, Byung-Ryong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.10
    • /
    • pp.823-832
    • /
    • 2018
  • In general, the fidelity of the aircraft dynamic model is verified by comparison with the flight test results of the target aircraft. Therefore, the reference flight data for performance comparisons must be extracted. This process requires a lot of time and manpower to extract useful data from the vast quantity of flight test data containing various noise for comparing fidelity. In particular, processing of flight data is complex because rotorcraft have high non-linearity characteristics such as coupling and wake interference effect and perform various maneuvers such as hover and backward flight. This study defines flight data processing criteria for rotorcraft and provides procedures and methods for automated processing of static and dynamic flight data using data mining techniques. Finally, the methods presented are validated using flight data.

A Study on the Development of Protective Inner Wear for Lumbar Disc Disease Patients (Part II) -Development of Female Inner Wear and Wearing Test- (허리디스크 환자를 위한 허리보호용 이너웨어 개발 연구(제2보) -여성 이너웨어 개발과 착의평가-)

  • Kang, Hye-Jin;Jung, Myoung-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.1
    • /
    • pp.141-152
    • /
    • 2017
  • The lumbar disc is one of the first parts of the human body to age. Female discs start to age at twenty and completely age between fifty and sixty. The number of lumbar herniated intervertebral disc patients is increasing rapidly; however, studies on protective inner wear are insufficient. This study develops protective inner wear equipment for bodies. The following were the study methods and procedures. First, the protective design, pattern and making of the inner wear were based on the analysis of collected data. Second, one subject was selected, then human body parts were measured to create the inner protective pattern. The inner pattern was made by the basic size of the subject. The inner protective equipment was made for lumbar disc disease patients after a wearing test and after correcting the pattern. Third, inner protective equipment was thoroughly tested to verify the compatibility of lumbar pads. The following were the study results and observations. First, lumbar pads who had inner protection were easily worn and the design was very ladyish in contrast to other lumbar pads on the market. Second, the pattern was completed by referring to, Lee Hyoung Sook's, torso and her lumbar pad shape. The fabric was mesh (for good ventilation) and poly spandex (for elasticity). Third, lumbar inner protective equipment was verified through a subject assessment and a major assessment. This study showed high scores on appearance and functional satisfaction versus existing disc lumbar pads in the market. This study predicts that new waist protective inner wear can help the female patient's health and social life because it has great functionality and can maintain outer line patterns.

Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures (공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도-)

  • 신용철;이병규;이지태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.1
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.

Clipping of the Anterior Communicating Artery Aneurysm without Sylvian Fissure Dissection

  • Yun, Ji-Kwang;Kang, Sung-Don;Kim, Joon-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.5
    • /
    • pp.388-391
    • /
    • 2007
  • Objective : The focus of aneurysm surgery is eliminating unnecessary operative manipulations and preparing the surgeon for any crises that might arise. With this concept in mind, we have tried resection of the gyrus rectus without routine sylvian fissure dissection in selected patients with anterior communicating artery (ACom) aneurysms, and compared these results with those from the conventional transsylvian approach. Methods : This retrospective study included 231 surgically treated patients with ACom aneurysms from March, 1997 to May, 2005. The patients were divided into two groups : Group A (96 with sylvian fissure dissection, March, 1997-December, 2000) and Group B (135 without sylvian fissure dissection, January, 2001-May, 2005). Overall surgical outcomes were compared, and operative times have been prospectively recorded since January, 04 to evaluate how this maneuver affected the length of surgical procedures. Results : All aneurysms were satisfactorily clipped, and there was no evidence of increased number of procedure-related retraction injuries in group B. Overall outcome was good in 186 (80.5%); 76 (79.2%) in group A, and 110 (815%) in group B ($x^2$ test, p=0.79). In good clinical grade of group A, good outcome was observed in 60 patients (89.6%) and in group B, 97 patients (94.2%) (Fisher's exact test, p=0.38) (Fig. 2). Conclusion : In this study, eliminating the step of sylvian fissure dissection by gentle lateral basal-frontal retraction to the side of the sylvian fissure did not increase morbidity and mortality. However, we do not intend to modify the standard approach to the ACom aneurysm that is familiar to and has been mastered by many others. Rather, we report our experience on the basis of our anatomic understanding of the technique and its results.