• Title/Summary/Keyword: Test effectiveness

Search Result 4,162, Processing Time 0.033 seconds

Radiation Exposure Dose Reduction on Upper Gastrointestinal Series (위장조영검사에서 피폭선량 저감)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2017
  • Upper gastrointestinal series is non-invasive examination, and it is useful for patients or elderly patients who have difficulty in endoscopic examination because of absence of any side effects other than temporary constipation or abdominal pain. The entire image of the gastrointestinal tract can be seen and have been widely used in the diagnosis of upper gastrointestinal diseases. However, there is a possibility that radiation dose increases due to improper movement and breath control, when examination is carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. In upper gastrointestinal series to increase understanding of examination, to induce appropriate cooperation during examination, to reduce the number of retakes and shorten examination time, and to reduce dose of the subject, the procedure and precautions of the gastrointestinal test were made as a movie. We investigated the effectiveness of pre-education using the movie to reduce the inspection time, the number of re-shoots, and the reduction of exposure dose by watching the movie during the waiting time before examination. 120 patients that were selected each 20 patients aged from 30s to 80s were evaluated were evaluated for exposure dose, examination time, and the number of retakes before and after the movie training. The radiation dose, the examination time, and the number of retakes were respectively $3171.83{\mu}Gy{\cdot}m^2$ and $2931.73{\mu}Gy{\cdot}m^2$, 8.05 min, and 6.75 min, and 1.68 times and 1.22 times before and after movie training. It can be concluded that the movie training on the gastrointestinal examination influences the reduction of the examination time, the number of retakes and the reduction of the radiation dose.

The Chemical Properties and Fertilizer Effect of a Residual By-product of Glutamic Acid Fermentation -I. Chemical properties and effect on the growth of corn (구르타민 산발효잔사가공물(酸醱酵殘渣加工物)의 성질(性質)과 비효 -I. 그 성질(性質)과 옥수수에 대(對)한 비효)

  • Hong, Chong Woon;Jung, Yee Geun;Park, Chon Suh;Kim, Yung Sup
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.6 no.3
    • /
    • pp.159-163
    • /
    • 1973
  • A by-product from glutamic acid fermentation prepared by treating the fermentation residue with sulfuric acid and ammonium hydroxide was studied in the light of its chemical properties by chemical analysis and X-ray diffraction technique. Its effectiveness as fertilizer was also investigated with corn as test plant. The results are summarized as following. 1. The chemical analyses and study with X-ray diffraction technique revealed that the by-product contains an appreciable quantity of water soluble ammonium as ammonium sulfate and ammonium chloride, water soluble amino acid and in-soluble organic carbon. Particularly, the X-diffraction pattern of the material indicated the presence of unidentified water soluble double salt of ammonium sulfate and ammonium chloride. 2. The water soluble ammonium in this material was found to be as effective as urea on the growth of corn plant. 3. The organic portion of the material was found to be equally effective on the growth of corn plant as the other sources of organic matter such as compost and rice bran. It was, however found that the organic matter in the fermentation residue is more persisting in the soil than the compost and rice bran. 4. It was noticed that the application of the fermentation by-product, lowers the soil pH significantly. Inspite of the pH lowering effect, the absorption of iron by corn plant was surpressed by the application of this material.

  • PDF

Treatment Outcomes and Acoustic Rhinometric Results in Endoscopic Sinus Surgery of Adult Chronic Paranasal Sinusitis (성인 말성 부비동염에서 내시경적 부비동 수술 전.후의 증상 호전도와 음향비강통기도 검사 결과)

  • Kim, Yong-Dae;Kim, Jae-Yeul;Chang, Keun-Young;Lee, Hyung-Joong;Song, Si-Youn;Yoon, Seok-Keun
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.1
    • /
    • pp.28-38
    • /
    • 2002
  • Background: Chronic paranasal sinusitis is one of the most common disease in the otorhinolaryngologic field. Endoscopic sinus surgery is treatment of choice in chronic paranasal sinusitis. The aim of this study was to evaluate objective and subjective treatment outcomes of endoscopic sinus surgery in adult chronic paranasal sinusitis with or without polyp. Materials and Methods: We reviewed 84 adult patients underwent endoscopic sinus surgery by one surgeon from June 1999 to June 2000, prospectively. We analyzed preoperative and postoperative subjective symptom scores and acoustic rhinometric results. Results: Fifty cases were male and thirty four cases female. The average age was of 33 year-old (range: 17 to 66 years). There was significantly improvement of symptom scores in postoperative 3 months and 6 months compared with preoperative symptom scores. There was significantly increased postoperative total volume of nasal cavity. When we compared high score group with low score group, there was statistically significant improvement of symptom scores between preoperative stage and postoperative 3 months in radiologic grading group. Conclusions: Endoscopic sinus surgery is considered to be effective for the treatment of chronic paranasal sinusitis. It seems to be helpful to employ subjective symptom score system and objective total volume change of nasal cavity through acoustic rhinometric test to analyze effectiveness of endoscopic sinus surgery. In this study, the most important preoperative factor of sinus surgery outcomes is radiologic grading system.

  • PDF

Intelligent Optimal Route Planning Based on Context Awareness (상황인식 기반 지능형 최적 경로계획)

  • Lee, Hyun-Jung;Chang, Yong-Sik
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.117-137
    • /
    • 2009
  • Recently, intelligent traffic information systems have enabled people to forecast traffic conditions before hitting the road. These convenient systems operate on the basis of data reflecting current road and traffic conditions as well as distance-based data between locations. Thanks to the rapid development of ubiquitous computing, tremendous context data have become readily available making vehicle route planning easier than ever. Previous research in relation to optimization of vehicle route planning merely focused on finding the optimal distance between locations. Contexts reflecting the road and traffic conditions were then not seriously treated as a way to resolve the optimal routing problems based on distance-based route planning, because this kind of information does not have much significant impact on traffic routing until a a complex traffic situation arises. Further, it was also not easy to take into full account the traffic contexts for resolving optimal routing problems because predicting the dynamic traffic situations was regarded a daunting task. However, with rapid increase in traffic complexity the importance of developing contexts reflecting data related to moving costs has emerged. Hence, this research proposes a framework designed to resolve an optimal route planning problem by taking full account of additional moving cost such as road traffic cost and weather cost, among others. Recent technological development particularly in the ubiquitous computing environment has facilitated the collection of such data. This framework is based on the contexts of time, traffic, and environment, which addresses the following issues. First, we clarify and classify the diverse contexts that affect a vehicle's velocity and estimates the optimization of moving cost based on dynamic programming that accounts for the context cost according to the variance of contexts. Second, the velocity reduction rate is applied to find the optimal route (shortest path) using the context data on the current traffic condition. The velocity reduction rate infers to the degree of possible velocity including moving vehicles' considerable road and traffic contexts, indicating the statistical or experimental data. Knowledge generated in this papercan be referenced by several organizations which deal with road and traffic data. Third, in experimentation, we evaluate the effectiveness of the proposed context-based optimal route (shortest path) between locations by comparing it to the previously used distance-based shortest path. A vehicles' optimal route might change due to its diverse velocity caused by unexpected but potential dynamic situations depending on the road condition. This study includes such context variables as 'road congestion', 'work', 'accident', and 'weather' which can alter the traffic condition. The contexts can affect moving vehicle's velocity on the road. Since these context variables except for 'weather' are related to road conditions, relevant data were provided by the Korea Expressway Corporation. The 'weather'-related data were attained from the Korea Meteorological Administration. The aware contexts are classified contexts causing reduction of vehicles' velocity which determines the velocity reduction rate. To find the optimal route (shortest path), we introduced the velocity reduction rate in the context for calculating a vehicle's velocity reflecting composite contexts when one event synchronizes with another. We then proposed a context-based optimal route (shortest path) algorithm based on the dynamic programming. The algorithm is composed of three steps. In the first initialization step, departure and destination locations are given, and the path step is initialized as 0. In the second step, moving costs including composite contexts into account between locations on path are estimated using the velocity reduction rate by context as increasing path steps. In the third step, the optimal route (shortest path) is retrieved through back-tracking. In the provided research model, we designed a framework to account for context awareness, moving cost estimation (taking both composite and single contexts into account), and optimal route (shortest path) algorithm (based on dynamic programming). Through illustrative experimentation using the Wilcoxon signed rank test, we proved that context-based route planning is much more effective than distance-based route planning., In addition, we found that the optimal solution (shortest paths) through the distance-based route planning might not be optimized in real situation because road condition is very dynamic and unpredictable while affecting most vehicles' moving costs. For further study, while more information is needed for a more accurate estimation of moving vehicles' costs, this study still stands viable in the applications to reduce moving costs by effective route planning. For instance, it could be applied to deliverers' decision making to enhance their decision satisfaction when they meet unpredictable dynamic situations in moving vehicles on the road. Overall, we conclude that taking into account the contexts as a part of costs is a meaningful and sensible approach to in resolving the optimal route problem.

H.264/SVC Spatial Scalability Coding based Terrestrial Multi-channel Hybrid HD Broadcasting Service Framework and Performance Analysis on H.264/SVC (H.264/SVC 공간 계위 부호화 기반 지상파 다채널 하이브리드 고화질 방송 서비스 프레임워크 및 H.264/SVC 부호화 성능 평가)

  • Kim, Dae-Eun;Lee, Bum-Shik;Kim, Mun-Churl;Kim, Byung-Sun;Hahm, Sang-Jin;Lee, Keun-Sik
    • Journal of Broadcast Engineering
    • /
    • v.17 no.4
    • /
    • pp.640-658
    • /
    • 2012
  • One of the existing terrestrial multi-channel DTV service frameworks, called KoreaView, provides four programs, composed of MPEG-2 based one HD video and H.264/AVC based three SD videos within one single 6MHz frequency bandwidth. However the additional 3 SD videos can not provide enough quality due to its reduced spatial resolution and low target bitrates. In this paper, we propose a framework, which is called a terrestrial multi-channel high quality hybrid DTV service, to overcome such a weakness of KoreaView services. In the proposed framework, the three additional SD videos are encoded based on an H.264/SVC Spatial Base layer, which is compliant with H.264/AVC, and are delivered via broadcasting networks. On the other hand, and the corresponding three additional HD videos are encoded based on an H.264/SVC Spatial Enhancement layer, which are transmitted over broadband networks such as Internet, thus allowing the three additional videos for users with better quality of experience. In order to verify the effectiveness of the proposed framework, various experimental results are provided for real video contents being used for DTV services. First, the experimental results show that, when the SD sequences are encoded by the H.264/SVC Spatial Base layer at a target bitrate of 1.5Mbps, the resulting PSNR values are ranged from 34.5dB to 42.9dB, which is a sufficient level of service quality. Also it is noted that 690kbps-8,200kbps are needed for the HD test sequences when they are encoded in the H.264/SVC Spatial Enhancement layer at similar PSNR values for the same HD sequences encoded by MPEG-2 at a target bitrate of 12 Mbps.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Modified Blalock-Taussig Shunt in Neonates (신생아에서 변형 Blalock-Taussig 단락술)

  • 조광조;성시찬
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.378-382
    • /
    • 1997
  • To evaulate the effectiveness and risk factors for shunt failure of the Blalock-Taussig shunt in neonates, we analyzed the 21 neonates who were undergone Blalok-Taussig shunt operation at Dong-A University Hospital from December 1991 to Feburary 1996. We evaluated operative mortality, patency of the shunt. and distortion of pulmonary artery. We also determined the risk factors for the shunt failure. Age at operation was from 1 day to 30 days(mean 11.7 days). We ghts were 2.4 to 4.5kg(mean 3.1 kg). The underlying lesions included severe tetralogy of Fallot with pulmonary stenosls or atresia(N=11) and single ventricle varieties with. pulmonary stenosis or atresia(N=10). Prostaglandin El was given in 13 neonates prior to operation. The mean preoperative(prior to prostaglandin El therapy) and postoperative arterial oxygen tension were 30.1 mmHg and 46.3 mmHg respectively(P(0.01). The shunt was performed through a left thoracotomy in 11 patients and through a right thoracotomy In 10. A 5 mm graft was used in 15 patients and a 4 mm graft in 6 patients. The incidence of early shunt occlusion was 9.5%(2 patients). The hospital mortality was 9.5%(2 patients with early shunt occlusion). Univariate analysis revealed that body weight of 2.6 kg or less(p=0.021), pulmonary artery size of 3mm or less(p=0.008), and 4 mm graft (p=0.021) were risk factors predictive of early shunt failure. The patency rate of the shunt in hospital survivors was 100% at mean ollow-up of ll.3 months(There was not death or reoperation related to shunt failure). 10 patients were catheterized during postoperative follow-up. There was no significant distorsion of pulmonary artery. So we concluded that the modified Blalock-Taussig shunt in neonates was excellent in the hospital survivors.

  • PDF

Purification of Vibrio anguillarum Growth Inhibition Factor Produced by Bacillus amyloliquefaciens H41. (Bacillus amyloliquefaciens H41이 생산하는 Vibrio anguillarum 생육 저해인자의 정제)

  • Shin, Hyun-Chul;Chung, Kyung-Tae;Kim, Kwang-Hyun;Kim, Byung-Woo;Kwon, Hyun-Ju;Lee, Eun-Woo;Yum, Jong-Hwa;Rhu, Eun-Ju;Jeong, Yu-Jeong;Kim, Young-Hee
    • Journal of Life Science
    • /
    • v.18 no.6
    • /
    • pp.789-795
    • /
    • 2008
  • To study the possible use of probiotics in fish farming, we evaluated antagonism of antibacterial strain Bacillus amyloliquefaciens H41 against the fish pathogenic bacterium Vibrio anguillarum NCMB1. The purification of growth inhibition factor produced by B. amyloliquefaciens H41 was achieved by obtaining supernatant of this bacterium. The growth inhibition factor was purified to homogeneity by 70% ammonium sulfate precipitation, DEAE-sephadex A-50 ion exchange chromatography, sephadex G-200 gel filtration column chromatography, and sephadex G-50 gel filtration column chromatography with 40.8 fold of purification and 2.9% yield. The molecular weight of the purified growth inhibition factor was 48 kDa as determined by sodium dodecyl sulfate polyacrylamide gel electrophoresis. The optimum pH and temperature for the growth inhibition factor were pH 7.5 and $30^{\circ}C$, respectively. The activity of growth inhibition factor was enhanced slightly by some metal ions, such as $Mg^{+2}$, $Mn^{+2}$, but was inhibited by the addition of $Co^{+2}$, $Hg^{+2}$, $Zn^{+2}$ and $Ag^{+2}$. NaCl stability of the growth inhibition factor was observed with 50% residual activity at 3% NaCl concentration. Toxicity test showed that the purified B. amyloliquefaciens H41 growth inhibition factor did not affect the live of Japanese flounder (Paralichthys olivaceus) and the effectiveness was 78% of residual lethality compared to commercial antibacterial agents.

Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS) (선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰)

  • Yoon, Joon;Lee, Gui-Won;Park, Byung-Moon
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In this paper we evaluated small field dose characteristics of exclusive cone fields versus square fields for stereotactic radiosugery (SRS) which is based on linear accelerators (LINAC). For this test, we used a small beam detector (stereotactic fields detector : SFD) with a 6 MV photon beam and a water phantom system (IBA, Germany). Percentage depth dose (PDD) was measured for different field sets (cones : ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$ ; square fields : $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$) at a source skin distance (SSD) of 100 cm. We measured the point depths at 1.5 cm, 5 cm, 10 cm, 20 cm, and 30 cm. The output factors were measured under the same geometrical conditions of the PDD and normalized at the maximum dose depth. To analyze the penumbra, we measured the dose profile with 95 cm of SSD, 5 cm of depth for each field sizes (${\Phi}1\;cm$, ${\Phi}3\;cm$, $1{\times}1\;cm^2$, and $3{\times}3\;cm^2$) using SFD. We obtained the values for every 1 mm interval in the physical field (90%) and 0.5 mm interval in the penumbra region (20 to 80%). The PDD variation of exclusive cones and square fields were 4.3 to 7.9% lesser than the standard field size ($10{\times}10\;cm^2$. The variation of PDD was reduced while the field size was increased. To compare the beam quality, we analyzed the $PDD_{20,10}$ and the results showed under the 1% of variations for all experiments except for ${\Phi}1\;cm$ cone and $1{\times}1\;cm^2$ fields. Output factors of exclusive cone were increased 3.1~4.6% than the square fields, and the penumbra region of exclusive cone was reduced 20% as compared to the square fields. As the previous researches report, it is very important for SRS and SFD that precise dosimetry in small beam fields. In this paper, we showed the effectiveness of exclusive cone, compared to square field. And we will study on the various detector characteristics for small beam fields.

Clinical Utility of Bone Scan in the Diagnosis of Temporomandibular Disorders (측두하악장애의 진단에서 Bone Scan의 유용성)

  • Kim, In-Joo;Kang, Yang-Ho;Son, Seok-Man;Lee, Kyoung-Seog;Lee, Jae-Bok;Kim, Yong-Ki;Seo, Bong-Jik;Park, June-Sang;Ko, Myung-Yun;Son, Seong-Pyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.511-517
    • /
    • 1995
  • Bone scan is a very sensitive diagnostic imaging test for detecting bone and joint disorders. So it might be useful in the diagnosis of temporomandibular disorders of the joint origin. Thus, the effectiveness of bone scan for detecting temporomandibular joint(TMJ) diseases and differentiating the TMJ disc displacement from the TMJ arthritis was evaluated. Bone scan was done in 21 patients with TMJ disc displacement(13 unilaterally affected, 8 bilaterally affected), 25 patients with TMJ arthritis(23 unilateral, 3 bilateral), and 39 volunteers with no signs, symtoms, or history of TMJ disease. TMJ simple uptake rate(SUR) and difference of both TMJ SUR were calculated from the 100,000 count lateral image of head and neck region in 99mTc MDP bone scan. Transcranial and panorama X-ray examination was also done in all patients. TMJ SUR(%) were $1.673{\pm}0.606$ in TMJs affected with arthritis, $1350{\pm}0.351$ in TMJs affected with disc displacement, and $1.084{\pm}0.172$ in TMJs of controls. Significant differences were demonstrated among them(p<0.01) Difference of bith TMJ SUR was highest in patients with unilateral TMJ arthritis($0.608{\pm}$0.533, p<001), and there is no significant difference between that of controls and that of unilateral TMJ dist displacement patients($0.062{\pm}0.063$ vs $0.122{\pm}0.100$). TMJ SUR of Joint with bone change on X-ray finding was not significantly different from that of joint with normal X-ray finding. Those in patients with unilateral TMJ disc displacement(696% and 87% vs 23.1% and 23%). The proportions of patients with increased TMJ SUR and difference of both TMJ SUR(>mean+2SD of controls) in unilateral TMJ arthritis patients were significantly higher than those in patients with unilateral TMJ disc displacement(69.6% and 87% vs 23.1% and 23%). Conclusively, bone scan nay help to detect TMJ disease and differentiate TMJ disc displacement from TMJ arthritis.

  • PDF