• Title/Summary/Keyword: Test device

검색결과 3,569건 처리시간 0.034초

호흡보조의료기기의 사용목적 및 대상에 따른 규격적용 방안 및 성능에 관한 연구 (A Study for Application of Standard and Performance Test According to Purpose and Subject of Respiratory Medical Device)

  • 박준현;호예지;이덕희;최재순
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권5호
    • /
    • pp.215-221
    • /
    • 2019
  • The respiratory medical device is a medical device that delivers optimal oxygen or a certain amount of humidification to a patient by delivering artificial respiration to a patient through a machine when the patient has lost the ability to breathe spontaneously. These include respirators for use in chronic obstructive pulmonary disease and anesthesia or emergency situations, and positive airway pressure devices for treating sleep apnea, and as the population of COPD (chronic obstructive pulmonary disease) and elderly people worldwide surge, the market for the respiratory medical devices it is getting bigger. As the demand for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, the boundaries between the items are blurred due to the purpose, intended use, and method of use overlapping similar items in a respiratory medical device. In addition, for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, in this study, we propose clear classification criteria for the respiratory medical devices according to the purpose, intended use, and method of use and provide safety and performance evaluation guidelines for those items to help quality control of the medical devices. And to contribute to the rapid regulating and improvement of public health. This study investigated the safety and performance test methods through the principles of the respiratory medical device, national and international standards, domestic and international licensing status, and related literature surveys. The results of this study are derived from the safety and performance test items in the individual ventilator(ISO 80601-2-72), the International Standard for positive airway pressure device (ISO 80601-2-70), The safety and performance of humidifiers (ISO 80601-2-74) and the safety evaluation items related to home healthcare environment (IEC 60601-1-11), In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers and importers, certified test inspection institutions, academia, etc., the final guidelines were established through revision and supplementation. Therefore, in this study, we propose guidelines for evaluating the safety and performance of the respiratory medical device in accordance with growing technology development.

스피커를 이용한 400km/h급 고속철도 소음저감용 방음벽 상단장치의 음향성능 시험방법에 관한 연구 (A study on the acoustic performance test method using speaker of a noise reduction device for noise reduction of the 400km/h class high-speed railroad)

  • 윤제원;김영찬;장강석;엄기영;장승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.625-629
    • /
    • 2014
  • For the purpose of the acoustic performance evaluation of noise reduction device(NRD) installed at the top of noise barrier for further decreasing of noise level of 400km/h class high-speed railroad(HEMU), the acoustic performance test method using speaker instead of really running railway vehicle was suggested in this paper. For this, noise source location and frequency spectrum of HEMU was analyzed through the field noise test. These data were used for the determination of speaker's installation positions and frequency correction values applied to the speaker noise source. And, 400 meters long NRD was installed at the site where HEMU will be running at a speed of 400km/h. Finally, the outdoor speaker test with and without NRD showed that this NRD could decrease noise level even more than 3dB(A). In the future, the acoustic performance results of NRD conducted with speaker test will be compared with that of field test for HEMU running at a speed of 400km/h.

  • PDF

풍력발전기용 증속기 시험 장비의 토크 인가 장치 설계 (Design of a Torque Application Device in Test Rig for a Wind Turbine Gearbox)

  • 김정길;박영준;이근호;남용윤;오주영
    • 대한기계학회논문집A
    • /
    • 제39권5호
    • /
    • pp.507-515
    • /
    • 2015
  • 본 연구는 5.5MW 증속기용 기계식 동력순환 시험 장비의 핵심 기능을 하는 토크 인가 장치의 개발 및 검증에 관한 것으로, 설계 및 해석이 수행되었다. 또한, 시험 장비의 각 부품에 대하여 회전각을 측정하여 비틀림 강성을 확인하였다. 시험체를 제외한 시험 장비에 토크를 인가하여 각 부품의 회전각을 측정한 결과 시험 장비의 비틀림 강성은 정방향에서 231.13 kNm/rad으로 나타났으며, 증속기 1대의 비틀림 강성이 1,064,400 kNm/rad보다 큰 경우 정격 토크를 인가할 수 있다. 따라서 시험 장비의 회전각 한계로 인하여 시험체 증속기의 비틀림 강성에 따라 정격 토크 인가 여부가 결정된다.

Student Responses to Smart Device-Based Test on Competency Evaluation in Dental Education

  • Kim, Jooah;Kim, Soo-Yoon
    • Journal of Korean Dental Science
    • /
    • 제12권2호
    • /
    • pp.58-65
    • /
    • 2019
  • Purpose: This study was aimed to investigate the possibility of utilizing smart device-based test (SBT) for competency evaluation in dental education and to analyze the student responses on overall competency evaluation using SBT method, in comparison to ubiquitous-based test (UBT). Materials and Methods: Questionnaire surveys have been conducted at Yonsei University College of Dentistry from 2015 to 2018 to obtain students' feedback on the application of SBT to competency evaluation. In addition, in order to supplement the competency evaluation procedure, considerations were explored by comparing the expected and actual difficulty of each item when preparing items for competency evaluation with SBT. Result: According to the survey results, student responses between the initial two years (2015 and 2016) differed from those in next two years (2017 and 2018). Students in 2017 and 2018 had more positive responses on competency evaluation with SBT. To determine the test validity, criterion-referenced evaluation was adopted to compare the data in 2017 and 2018 and slight differences in test difficulty in 2018 between the expected and actual difficulty of items were found. Conclusion: The results indicated that SBT was more appropriate for competency evaluation than UBT, based on four-year period of competency evaluation. The SBT was not affected by either the file size or the number of test-takers. Interestingly, students were not sensitive to test version of competency evaluation (paper-based test and SBT). This study suggests that the quality of the test items should be measured by continuous monitoring of the expected and actual difficulty of items for determining test validity. More detailed results and discussions of the findings are given for the development of test procedure and further potential research directions in dental education.

전기-기계식 점화안전장치 개발 (Development of Electro-Mechanical Ignition Safety Device)

  • 장승교;강호준
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.332-335
    • /
    • 2011
  • 고체 로켓 추진기관에 적용 가능한 전기-기계식 점화안전장치를 설계하고 제작하였다. 본 전기-기계식 점화안전장치는 로터리 솔레노이드를 이용하여 장전되고 내장된 전기식 착화기를 발화하여 점화 에너지를 발생시킨다. 점화안전장치의 점화 성능을 검증하기 위한 방법으로 10-cc 밀폐용기 시험(Closed Bomb Test)을 실시하였고 점화안전장치 작동시 발생되는 고온, 고압의 가스로 인하여 밀폐용기 내부에 형성되는 압력을 계측하였다.

  • PDF

범용 부품을 이용한 M-PHY AFE Block 개발 (Development of The M-PHY AFE Block Using Universal Components)

  • 최병선;오호형
    • 반도체디스플레이기술학회지
    • /
    • 제14권2호
    • /
    • pp.67-72
    • /
    • 2015
  • For the development of UFS device test system, M-PHY specifications should be matched with MIPI-standard which is analog signal protocol. In this paper, the implementation methodology and hardware structure for the M-PHY AFE (Analog Front End) Block was suggested that it can be implemented using universal components without ASIC process. The testing procedure has a jitter problem so to solve the problems we using ASIC process, normally but the ASIC process needs a lot of developing cost making the UFS device test system. In is paper, the suggestion was verified by the output signal which was compared to the MIPI-standard on the Prototype-board using universal components. The board was reduced the jitter on the condition of HS-TX and 5.824 Gbps Mode in SerDes (Serialize-deserializer). Finally, the suggestion and developed AFE block have a useful better than ASIC process on developing costs of the industrial UFS device test system.

SMD Inductor Core의 전기적 특성 (The Characteristics of SMD Inductor Core)

  • 오용철;김진사;이동규;신철기;김기준;이철환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 2005
  • In this study, it analysis electric field of SMD(Surface Mounted Device) Inductor Core and it get electric field only exist inside of SMD core. Therefore electric fields do not affect any device and equipments. These results are very important to design data acquisition system(several test equipments such as temperature, impedance, and current test), because data acquisition system can place under the SND Inductor core. So, it can be decrease their test error due to electric field.

  • PDF

킥모터 점화안전장치 환경시험 (Environmental Tests of Kick Motor Safety and Arming Device)

  • 고현석;길경섭;조인현
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.703-704
    • /
    • 2010
  • 고신뢰도의 점화안전장치를 제작하기 위해 비행환경을 모사하는 환경시험을 수행하였다. 초기 설계에서 모터조립체를 진동 및 충격으로부터 보호하기 위한 구조물을 추가하였으며, 필수 환경시험을 재수행하여 이러한 설계 변경 결과를 최종 검증하였다.

  • PDF

CD-RW Drive의 낙하충격 손상평가 (Damage Evaluation of CD-RW Drive by Drop Test and Simulation)

  • 우재철;윤기원;석기영;김헌영;김상범
    • 대한기계학회논문집A
    • /
    • 제29권1호
    • /
    • pp.81-87
    • /
    • 2005
  • A fracture of hand held device, such as radio, TV and CD-RW drive, mainly occurs due to drop situation. For CD-RW drive, the need of high reading/writing speed in conjunction with low price accelerates the fracture of the device. Computer simulation can reduce the period of development and enhance impact characteristic of device. In this study, the detailed finite element model of CD-RW drive was developed to predict the damage under drop conditions. Material property for shock absorbing damper was obtained from tensile test of raw material. A MOONEY-RIVLIN type rubber in LS-DYNA was used as the material model of damper. To assess the reliability of the developed model, drop test at 200G-2msec and 150G-10msec condition was conducted and acceleration at pick-up was compared.

소자 시뮬레이션을 이용한 Circuit Model Parameter 생성에 대한 연구 (The Study of Circuit Model Parameter Generation Using Device Simulation)

  • 이흥주
    • 한국산학기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.177-182
    • /
    • 2003
  • Flash memory는 device 특성상 peripheral circuit을 구성하는 transistor의 종류가 다양하고, 이에 따른 각 transistor의 동작 전압 영역이 넓다. 이에 따라 설계 초기의 전기적 특성 사양 결정을 위해서는, 실리콘상에서 소자의 scale down에 따른 전기적 특성을 선 검증하는 과정이 필수적이었으며, 이로 인해 설계 및 소자 개발의 기간을 단축하기 어려웠다. 본 연구에서는 TCAD tool을 사용하여 실리콘상에서의 제작 공정을 거치지 않고, 효과적으로 model parameter를 생성할 수 있도록 하는 방법을 제안하여 전기적 특성 사양 결정과 설계 단계의 시간 지연을 감소할 수 있도록 한다. 또한 성공적 TCAD tool적용을 위해 필요한 process/device simulator의 calibration methodology와 이를 flash 메모리 소자에 대해 적용 검증한 결과를 분석한다.

  • PDF