• 제목/요약/키워드: Test center

검색결과 13,272건 처리시간 0.043초

Soil-Bentonite 혼합토의 투수 특성 연구 (A on Permeability Characteristics of Soil-Bentonite Mixture)

  • 임은상;신동훈;조성은;김재홍
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.852-857
    • /
    • 2009
  • Recently the centrifuge test has been used increasingly to clarify a problem of seepage in dam. However, one of the most difficult challenges in the testing is to conform permeability properties of model ground to the prototype. In order to resolve the problem, a few solutions, such as an increase of pore water viscosity and a regulation of water permeability, are suggested. Although the use of prototype materials is principles if a model test is carried out, the materials of similarity gradation is used in the centrifuge model test because of the nature of the model test for dam. Therefore, we choose the latter method for model ground materials. In this study, the permeability properties of soil-bentonite mixtures are studied through the permeation test using triaxial compaction test apparatus.

  • PDF

고장 진단 및 예지가 가능한 로봇용 감속기 내구성능평가 장치 개발 (Development of a Lifetime Test Bench for Robot Reducers for Fault Diagnosis and Failure Prognostics)

  • 신주성;김주현;김종걸;김무림
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권3호
    • /
    • pp.33-41
    • /
    • 2019
  • This study presents the development of a lifetime test bench for the strain wave reducer which is a precision gear reducer of the robot to realize fault diagnosis and failure prognostics. To this end, the lifetime test bench was designed to detect the vertical forward/reverse direction rotation load. Through the lifetime test bench, it is possible to apply the same load spectrum from robot working scenarios. We developed a data integration gateway for fault data collection. Through the development of dedicated software for fault diagnosis and failure prognostics, these data from vibration, noise and temperature sensors were collected and analyzed along with the operation of the lifetime evaluation.

Study on Properties and Accelerated Life-time Test of Rubber O-ring by Temperature Stress

  • Shin, Young-Ju;Kang, Bong-Sung;Chung, Yu-Kyung;Choi, Kil-Yeong;Shin, Sei-Moon
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2006년도 학술발표대회 논문집
    • /
    • pp.48-54
    • /
    • 2006
  • In this thesis, accelerated life test (ALT) method and procedure for rubber O-ring are applied to assure specified reliability of the products at guaranteeing the life of the products. Rubber O-ring is parts that keep intensity or make machine operation smoothly on attrition portion of machine and is used to prevent that oil is leaked. Usually. Rubber O-ring used NBR that is copolymer of acrylonitrile and butadiene. this are superior oil resistance, heat resistance, durability of abrasion, cold resistance, chemical resistance etc. The accelerated life test model for rubber O-ring are developed using the relationship between stresses and life characteristics of products. Using the accelerated life test method and the acceleration life test equipment which is developed, we performed life test, collected life data and analyzed the results of tests. The proposed accelerated life test method and procedure may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably.

  • PDF

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • 한국전문물리치료학회지
    • /
    • 제26권3호
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

Application of Area-Saving RF Test Structure on Mobility Extraction

  • Lee, Jae-Hong;Kim, Jun-Soo;Park, Byung-Gook;Lee, Jong-Duk;Shin, Hyung-Cheol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권2호
    • /
    • pp.98-103
    • /
    • 2009
  • An RF test structure is proposed and its applicability is confirmed by measuring DC characteristics and high frequency characteristics. Effective mobility extraction is also performed to confirm the validity of proposed test structure. The area of suggested test structure consumed on wafer was decreased by more than 50% and its characteristics do not be degraded compared with conventional structure.

압입에 따른 알루미나 세라믹스의 이축 파괴 거동 (Biaxial Fracture Behavior of Alumina Ceramics : Indentation Effect on Ball-on-3-ball Test)

  • 정성민;박성은;이홍림
    • 한국세라믹학회지
    • /
    • 제37권7호
    • /
    • pp.713-720
    • /
    • 2000
  • The biaxial fracture behavior of alumina ceramics was studied using ball-on-3-ball test. The polished surfaces of alumina specimens were indented at 0mm, 1mm, 2mm, 3mm apart from the center of the specimen along path A, passing between the two supporting balls from the center of the specimen, and along path B, passing above the three supporting balls from the center of the specimen. The fracture strength of the indented specimens was measured using the ball-on-3-ball test, a kind of biaxial strength test. The fracture strength increased with increasing the distance from the center to indented position. The fracture strength of the specimen indented along path B was higher than that of the specimens indented along path A. It was presented that the fracture caused by tangential stress rather than radial stress when the indented positions are 1mm and 2mm from the center of the specimen. This phenomenon was in good agreement with FEM analysis.

  • PDF

중장비 엔진속도제어용 스텝모터 및 제어시스템 개발 (DEVELOPMENT OF STEP MOTOR AND CONTROL SYSTEM FOR HEAVY EQUIPMENT)

  • 배동진;이종인;이정일;박현준;김종구;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.98-100
    • /
    • 1995
  • This paper deals with development of high torque and high accurate stepping motor and control system which is adopted heavy equipment engine speed control. In the process of development, only pure domestic technics is involved, all the parts are supplied in domestic industries, and successfully accomplished to mass production. In order to confirm product liability, circumferential test,such as vibration test impact test,thermal test,and field test are thoroughly fulfilled.

  • PDF

Micronucleus test of SS cream and CJ-4001 using Acridine orange staining method

  • Park, Jie-Eun;Lee, Sung-Hak;Choi, Jae-Mook;Kim, Il-Hwan;Kim, Taek-Rho;Kim, Deog-Yeor;Noh, Hyun-Jung;Kang, Hee-Chol;Cho, Hi-Jae;Kim, Young-Hoon
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.118.1-118.1
    • /
    • 2003
  • SS cream and its revised formula, CJ-4001 is topical Chinese herbal drugs for premature ejaculation. To evaluate the genotoxic potentials of these drugs, micronucleus test using Acridine orange (AO) staining method was performed. Acridine orange (AO) staining is adopted in OECD guideline 474 and widely used in micronucleus test. In dose range finding study, no mouse was dead at 2000 mg/kg using single treatment subcutaneously. Therefore, 3 dose levels were chosen at 500, 1000, 2000 mg/kg. (omitted)

  • PDF

The First Report to Evaluate Safety of Cyanobacterium Leptolyngbya sp. KIOST-1 for Use as a Food Ingredient: Oral Acute Toxicity and Genotoxicity Study

  • Lee, Youngdeuk;Kim, Taeho;Lee, Won-Kyu;Ryu, Yong-Kyun;Kim, Ji Hyung;Jeong, Younsik;Park, Areumi;Lee, Yeon-Ji;Oh, Chulhong;Kang, Do-Hyung
    • Journal of Microbiology and Biotechnology
    • /
    • 제31권2호
    • /
    • pp.290-297
    • /
    • 2021
  • Leptolyngbya sp. KIOST-1 (LK1) is a newly isolated cyanobacterium that shows no obvious cytotoxicity and contains high protein content for both human and animal diets. However, only limited information is available on its toxic effects. The purpose of this study was to validate the safety of LK1 powder. Following Organisation for Economic Co-operation and Development (OECD) guidelines, a single-dose oral toxicity test in Sprague Dawley rats was performed. Genotoxicity was assessed using a bacterial reverse mutation test with Salmonella typhimurium (strains TA98, TA100, TA1535, and TA1537) and Escherichia coli WP2 uvrA, an in vitro mammalian chromosome aberration test using Chinese hamster lung cells, and an in vivo mammalian erythrocyte micronucleus test using Hsd:ICR (CD-1) SPF mouse bone marrow. After LK1 administration (2,500 mg/kg), there were no LK1-related body weight changes or necropsy findings. The reverse mutation test showed no increased reverse mutation upon exposure to 5,000 ㎍/plate of the LK1 powder, the maximum tested amount. The chromosome aberration test and micronucleus assay demonstrated no chromosomal abnormalities and genotoxicity, respectively, in the presence of the LK1 powder. The absence of physiological findings and genetic abnormalities suggests that LK1 powder is appropriate as a candidate biomass to be used as a safe food ingredient.

보통전력량계(III 형)의 경년변화 특성연구 (A study on the aging characteristics for model III watthour meters)

  • 김영래;홍순학;박구범;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.9-12
    • /
    • 1993
  • This study investigated the propriety and the extension of the term of validity about the using watthour meters at present. The subject of study is 1Cent 2W 220V 30(10)A, 1Cent 3W 110V 30(10)A of model III watthour meters. They are the used metes(products in 1984) and the repaired meters(products in 1977) in the end of the period. The investigation is as follows. o Investigation of external appearance o Driving current test o Creeping test o Noise test o Error test o Durability test. Results of the study have been the number of 13.3% exceeded permitting error and the number of 31.3% failed in endurable test of 500 hours. So, the using meters are not suitable to extend the term of validity without the improvement of several characteristics.

  • PDF