• Title/Summary/Keyword: Test Standard

Search Result 8,501, Processing Time 0.038 seconds

Scene Change Detection using the Automated Threshold Estimation Algorithm

  • Ko Kyong-Cheol;Rhee Yang-Won
    • The Journal of Information Systems
    • /
    • v.14 no.3
    • /
    • pp.117-122
    • /
    • 2005
  • This paper presents a method for detecting scene changes in video sequences, in which the $chi^{2}$-test is modified by imposing weights according to NTSC standard. To automatically determine threshold values for scene change detection, the proposed method utilizes the frame differences that are obtained by the weighted $chi^{2}$-test. In the first step, the mean and the standard deviation of the difference values are calculated, and then, we subtract the mean difference value from each difference value. In the next step, the same process is performed on the remained difference values, mean-subtracted frame differences, until the stopping criterion is satisfied. Finally, the threshold value for scene change detection is determined by the proposed automatic threshold estimation algorithm. The proposed method is tested on various video sources and, in the experimental results, it is shown that the proposed method is reliably estimates the thresholds and detects scene changes.

  • PDF

A Study on Incombustibility of Building Service System Insulation Material (설비용 단열재 난연성 평가 현황과 개선 방안)

  • Park, Jong-Il;Kim, Suk-Hyun;Hong, Jin-Kwan;Lee, Min-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.999-1005
    • /
    • 2006
  • The aim of this paper is to evaluation survey and improvement method of building service system insulation material incombustibility. In Korea, various insulation materials are being used to prevent energy losses. Performance of insulation materials is gradually advanced, and new insulation materials are developed and being used. We don't have prefer test standard of insulation material incombustibility. In this paper we investigate domestic and foreign standard about incombustibility Through the authors will show how we can improve incombustibility test standard in Korea.

  • PDF

A Study on the Development and Operation of Integrated Assessment System for National Competency Standard Professional Basic

  • Chang, Young-Hyun
    • International journal of advanced smart convergence
    • /
    • v.7 no.4
    • /
    • pp.121-127
    • /
    • 2018
  • This paper develops and builds an Integrated Assessment System for National Competency Standard Professional Basic. The integrated evaluation system for basic job competency in the National Competency Standards is developed to conduct examination by means of computers, smartphones and tablet PCs. The system can be used for the basic job competency test, examination for online cyber universities, job competency examination for enterprises, and the listening, reading, and speaking test in the foreign language proficiency examination and is even better in terms of facility investment and saved operating costs as well as efficient use of spaces in comparison with conventional evaluation schemes. Even greater synergy effects can be achieved by providing support for the integrated evaluation system for basic job competency in connection with the NCS qualification system. The evaluation system has been tested and practiced at a specialized high school and can be applied to the NCS education evaluation of the college and four-year college and to the selection examination of new employees of the company.

Report on the Stability of Freeze-dried Standard Solution (동결건조표준액의 안정성에 관한 보고)

  • Park, Jun Mo;Yoo, Hye Jung;Kim, Han Chul;Han, Geul Soon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.139-148
    • /
    • 2012
  • Purpose : Since standard solution is the one that knows its exact concentration, the curve of the dissolution has been determined according to the amount of the solution, compared to the amount of the unknown sample. Therefore, the antigen that makes up standard materials should be made in a pure form. The configuration of the standard substance solution in the kit we use is a freeze-dried material, or made and comes as a liquid. Lyophilized reference material is used after dissolving in usually D.W. (Distilled Water), and if the antigen to use is too sensitive, reagents should be freeze-dried. Furthermore, when freeze-dried reference has to be frozen again after being dissolved, it should be kept under $-20^{\circ}C$ until the expiration date according to the reports. Since it is not expressed in the experiment if it is safe or stable to reuse the solution which was dissolved a few times, thus, this time it is tested and evaluated that the changes of the standard solution by freezing and melting several times, and its results and the effectiveness of it were compared to the solution which was kept in a fridge. Materials and Methods : Among Vitro diagnostic kits on the market made by radioimmunoassay, parathyroid hormone (PTH), adrenocorticotropic hormone (ACTH), luteinizing hormone (LH) are made of freeze-dried standard solution and all composed of the same Lot.NO. These hormones melted in D.W. and were separated into three groups. In the first group, melting and freezing were repeated, and in the second group, The solution only for one time use was put into a test tube after melting and freeze it. The third group was kept in the refrigerator. This experiment has been conducted from January to February in 2012. January to 2012. PH test was employed because ph is prone to changing depending on the change of protein. Each group of the standard solution, cpm (counter per minute), and the patient relative concentration values were compared by date, and Through the correlation coefficient and Paired t-test, the significant level of each group was analyzed. Results : ACTH, PTH, LH pH values were too subtle denaturation rather than numerical changes in the protein. In addition, when the standard solution of ACTH, PTH, LH was refrigerated, after 3 days and 7 days, there was a significant difference observed between the solution being kept in a refrigerator and a freezer within a significance level. Conclusion : Standard solution should be kept in a freezer, and being kept in a fridge, it is recommended to use the solution as soon as possible.

  • PDF

A Study on the Integrated Computer Program for the Multi Analysis of In-Situ Aquifer and Geothermal Response Test (현장 열응답시험과 현장 대수성시험결과를 동시 분석 가능한 통합전산 Program에 관한 연구)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Yonn, Yun-Sang
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.4 no.1
    • /
    • pp.11-19
    • /
    • 2008
  • Groundwater flow in confined aquifer and heat transport in underground geologic media are using same governing equation(line source) like well fuction. Therefore the conventional slope method using only later data obtained from in-situ thermal response test to determine the thermal conductivity of vertical geothermal heat exchanger(GHEX) is basically identical with one of Theis straight line method of aquifer test under artesian condition. In case that the pumping rate(Q, $m^3$/d) and drawdown(s,m) which are used for input data of existing hydrogeologic computer programs for aquifer test are replaced and converted to supplying heat energy per unit length of bore hole(Q/L,w/m or Kcal/h.m) and temperatures (T,$^{\circ}C$)measured at in and out-let of GHEX as in put data respectively, thermal conductivity around geothermal heat exchanger can be easily estimated without any special modification of the existing hydrogeologic computer program. Two numbers of time series temperature variation data obtained from in situ geothermal response test are analized using Theismethods(standard curve and straight line method) by using existing aquifer test program and conventional Slope method proposed by ASHRAE. The results show that thermal conductivity values estimated by two straight methods are identical and the difference of estimated values between standard curve methods and Slope method are also within acceptable ranges. In general,the thermal conductivity estimated from Theis straight linemethod gives more accurate value than the one of Slope method due to that Slope method uses only visual matching otherwise Theis method uses automatic curve matching estimation with reducing RSS.

  • PDF

Determiniation and Validation of Alibendol using High Pressure Liquid Chromatography in Human plasma (고속액체크로마토그라피법을 이용한 사람 혈장 중 알리벤돌(Alibendol)의 정량 및 검증)

  • Song, Hyun-Ho;Yu, Ji-Young;Kim, Bo-Gyeom;Park, Hyeon-Ju;Choi, Kwang-Sik;Kwon, Young-Ee
    • YAKHAK HOEJI
    • /
    • v.54 no.4
    • /
    • pp.295-299
    • /
    • 2010
  • The aim of this study was to develop and validate for determination of alibendol in human plasma by HPLC method. After precipitation of 500 ${\mu}l$ plasma samples by 50% methanol 50 ${\mu}l$ and 60% perchloric acid 30 ${\mu}l$ and the supernatant 50 ${\mu}l$ was injected into HPLC. The assay was performed isocratically using 10 mM potassium phosphate (pH 3.0) and acetonitrile (80 : 20, v/v) as mobile phase. The $C_{18}$ column (particle size $3.5{\mu}m$, $4.6{\times}50$ mm, Zorbax Eclipse) was used as a solid phase. The mobile phase was delivered at a flow-rate of 1.7 ml/min, detection was by ultraviolet absorption at 232 nm and concentrations were calculated on the basis of peak areas. In these conditions, alibendol can be separated from ethylparaben, the internal standard, and endogenous substances. The retention times of alibendol and ethylparaben were just about 2.6 and 3.5 minutes, respectively. This rapid HPLC method was validated by examining the precision and accuracy for inter- and intra-day analysis. The standard curve was linear ($R^2$=1.0000) over the concentration range of 0.05~20 ${\mu}g$/ml. The inter-day relative standard deviation (R.S.D.) and accuracy were 0.2~12.2% and 94.4~101.2% (82.7% at the lower limit of quatitation). The intra-day R.S.D. and accuracy were 0.1~11.8% and 98.8~102.5%, respectively. The method was successfully applied to the determination of alibendol in plasma for a pharmacokinetic study.

Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing (비규격 초음파 탐상용 표준시험편의 사용안전성 평가)

  • Kwon, Ho-Young;Lim, Jong-Ho;Kang, Sei-Sun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.431-437
    • /
    • 2000
  • Standard Test Block(STB) for UT(Ultrasonic Testing) is a block approved by authoritative for material, shape and quality. STB is used for characteristic tests, sensitivity calibration and control of the time base range of UT inspection devices. The material, size and chemical components of STB should be strictly controled to meet the related standards such as ASTM and JIS because it has an effect upon sensitivity, resolution and reproductivity of UT. The STBs which are not approved are sometimes used because the qualified STBs are very expensive. So, the purpose of this study is to survey the characteristics, quality and usability of Non-Standardized Test Blocks. Non-Standardized Test Blocks did not meet the standard requirements in size or chemical components, and ultrasonic characteristics. Therefore if the Non-Standardized Test Blocks are used without being tested, it's likely to cause errors in detecting the location and measuring the size of the defects.

  • PDF

A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance (콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구)

  • Kim, Yeon-Jung;Kim, Nam-Ho;Shin Yun-Sup
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.261-269
    • /
    • 2006
  • Recently, piezocone penetration test is frequently used in order to estimate the characteristics of soft ground with standard penetration test; generally used in the past In this study, standard penetration test, piezocone penetration test, driving resistance of vertical drain were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows $q_c$=(1.09~1.63)N at the soft ground, determined by 5/30 N value. And $q_c$(1.21~1.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. And driving resistance of vertical drain is 70 f/$cm^2$ which is equal to 10kgf/$cm^2$ cone penetration resistance.

  • PDF

The study on Accelerated Life-Time Reliability Test Methods of Ni-Mn-B ternary alloy Plating(electrodeposit) (Ni-Mn-B 삼원합금도금 가속수명 및 신뢰성 평가에 대한 연구)

  • Ma, Seung-hwan;Noh, young-tai;Jang, gun-ik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.2993-2999
    • /
    • 2015
  • Steel companies are applying Ni-B or Ni-Co alloy plating to protect the surface of Continuous casting mold, and they are using saccharin polish which causes crack on plating layer due to sulfur in saccharin. It is considered that the Ni-S compound causes the cracking and additional tensile stresses. The Ni-Mn-B ternary alloy plating was developed for suppression of crack by forming Mn-S compound before Ni-S compound is formed, but there were no domestic or international standard on the Ni-Mn-B alloy plating. Therefore, reliability evaluation standard was established to evaluate the newly developed Ni-Mn-B plating. To develop accelerating life testing method, FMEA(Failure Mode & Effective analysis) was used to analyze the cause of the main failure in plating. The Ni-Mn-B reliability standard included accelerating life test method, and it was categorized by the fundamental performance test, environment test, and accelerated life test, and was designed to guarantee 1 000 hours of B10 life with 80 % reliable level.

The Experimental Study for the Combustion-Property of Sandwich Panels using ISO 5660 Cone Calorimeter (콘칼로리미터를 사용한 샌드위치패널 연소특성에 대한 실험적 연구)

  • Park, Soo-Young;Kim, Dae-Hoi;Im, Hong-Soon
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.33-41
    • /
    • 2006
  • Nowadays in Korea, KS F 2271(Testing method for incombustibility of internal finish material and element of buildings) has been using for the evaluation of fire safety performance of sandwich panels. The test method in Japan and in Korea was based on the same way. When the Japanese standard building code was revised in 2000, the test method in the ISO 5660-1 was adopted for the test method for combustion performance of internal finishing materials and elements of buildings. According to this, the revision version of draft substituting the test method in the KS F 2271 for one in the ISO 5660-1(Cone Calorimeter method) is informed in Korea. In this study, combustion properties of sandwich panels were tested using the cone calorimeter method. Ignition time, peak heat release rate and total heat released of four sandwich panels and four core materials (thermal insulation material), which are widely used in Korea, were tested. Test results were analyzed for each specimen. Finally, test results were classified by Japanese standard building code and Canadian NBC revised.