• Title/Summary/Keyword: Test Sequence

Search Result 1,295, Processing Time 0.035 seconds

High Temperature Friction Characteristic of $Al-SiC_{p}$ Composite Coating Prepared by Plasma Thermal Spray (플라즈마 용사에 의해 제조한 $Al-SiC_{p}$ 복합재료 코팅층의 고온마찰특성)

  • 민준원;유승을;서동수
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.274-279
    • /
    • 2003
  • $Al-SiC_{p}$ composite layer was prepared by plasma thermal spray on aluminum substrate. The homogeneously dispersed composite powder for thermal spray was fabricated by mechanical alloying with ball mill. The friction tests of the composite layers and commercial aluminum alloys for comparison were performed in the temperature range of 20∼$260^{\circ}C$ with the interval of $40^{\circ}C$ with steel counter-face. Friction coefficient was recorded during test sequence, and the microstructure of surface and debris was investigated by optical and scanning electron microscope. Friction coefficients of composite and aluminum alloys at room temperature were similar except pure aluminum. As the temperature increase, friction coefficient was increased rapidly in AC4C, AC2A. But friction coefficient of $Al-SiC_{p}$ composite was not increased so much up to $220^{\circ}C$. Consequently, the reinforcement of $SiC_{p}$ into aluminum matrix increased the stability of friction coefficient as well as wear resistance.

Sorption/Desorption Characteristics of Halogenated Aliphatic Compounds from Activated Sludge, Sediment, and Clay (지방족 할로겐화합물의 활성슬러지와 해안저질 및 점토에서의 흡탈착 특성)

  • 김종오;박종석;최연돈
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.961-969
    • /
    • 2002
  • This study was performed : 1) to establish the experimental analysis conditions for the sorption and desorption of toxic organic contaminants to/from the activated sludge, sediment, and clay, and 2) to determine the sorption and desorption equilibrium coefficients of some representative halogenated aliphatic compounds. Through the preliminary sorption test using Azo dye, a setting of quantitative experimental conditions to determine the sorption and desorption characteristics was decided as follows; equilibration time of 180 minutes, centrifuge for 15 minutes at 5000$\times$g, and 500mg/$\ell$ of TOC concentration. The sorption and desorption characteristics of halogenated aliphatic compounds onto activated sludge, sediment and clay could be described very well using the Freundlich isotherm. The preference of the average sorption capacity of the overall compounds showed in the sequence sediment 0.26mg/g, clay 0.23mg/g, and activated sludge 0.11 mg/g. The desorption rate of the sorbed compounds onto activated sludge, sediment and clay was approximately 89.8%, 35.3%, and 66.4%, respectively.

A Direction for Nursing Research (간호연구의 방황)

  • 김수지
    • Journal of Korean Academy of Nursing
    • /
    • v.18 no.2
    • /
    • pp.128-134
    • /
    • 1988
  • This paper argues that nursing theories ideosyncratic to situations should be developed through research, if nursing practice is to be effective in achieving the objective of promoting, maintaining, or restoring health of clients / patients. After reviewing (1) the interactive relationship between the theory and research, (2) the type and sequence of research for theory- building, (3) the hierarchy of theories, and (4) congruence between the type of theory and research approach, it suggests (1) that more exploratory studies (research) should be undertaken as a way to develop descriptive theories that may lead to new hypotheses, (2) that more empirical studies should also be undertaken to test if new hypotheses generated from exploratory studies may be useful in the setting of nuring practice, (3) that more studies should be undertaken to develop useful measures of nursing concepts, and (4) that more replicated studies should be undertaken in order to give rise to the external validity of new theories. It also discusses the ethical considerations of nursing research in the future.

  • PDF

Fault Location Algorithm with Ground Capacitance Compensation for Long Parallel Transmission Line (장거리 병렬 송전선로용 대지 정전용량 보상에 의한 고장점 표정 알고리즘)

  • Park, Chul-Won;Kim, Sam-Ryong;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.163-170
    • /
    • 2005
  • This paper deals with an improved fault location algorithm with compensation ground capacitance through distributed parameter for a long parallel T/L. For the purpose of fault locating algorithm non-influenced by source impedance and fault resistance, the loop method was used in the system modeling analysis. This algorithm uses a positive and negative sequence of the fault current for high accuracy of fault locating calculation. Power system model of 160km and 300km long parallel T/L was simulated using EMTP software. To evaluate of the proposed algorithm, we used the several different cases 64 sampled data per cycle. The test results show that the proposed algorithm was minimized the error factor and speed of fault location estimation.

A Study on Flame and Smoke Detection Method of a Tunnel Fire (터널 화재의 화염 및 연기 검출 기법 연구)

  • Lee, Jeong-Hun;Lee, Byoung-Moo;Han, Dong-Il
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1027-1028
    • /
    • 2008
  • In this paper, we proposed image-processing technique for automatic real-time fire and smoke detection in tunnel fire environment. To minimize false detection of fire in tunnel we used motion information of video sequence. And this makes it possible to detect exact position of event in early stage with detection, test, and verification procedures. In addition, by comparing false detection elimination results of each step, we have proved the validity and efficiency of proposed algorithm.

  • PDF

Kalman Filtering with Optimally Scheduled Measurements in Bandwidth Limited Communication Media

  • Pasand, Mohammad Mahdi Share;Montazeri, Mohsen
    • ETRI Journal
    • /
    • v.39 no.1
    • /
    • pp.13-20
    • /
    • 2017
  • A method is proposed for scheduling sensor accesses to the shared network in a networked control system. The proposed method determines the access order in which the sensors are granted medium access through minimization of the state estimation error covariance. Solving the problem by evaluating the error covariance for each possible ordered set of sensors is not practical for large systems. Therefore, a convex optimization problem is proposed, which yields approximate yet acceptable results. A state estimator is designed for the augmented system resulting from the incorporation of the optimally chosen communication sequence in the plant dynamics. A car suspension system simulation is conducted to test the proposed method. The results show promising improvement in the state estimation performance by reducing the estimation error norm compared to round-robin scheduling.

Impact Properties of New 3D Composites by Fiber Placement Processing (섬유 자동 배열에 의한 시로운 3D 복합재의 충격특성)

  • Song S-W;Lee C-H;Song J-E;Byun J-H;Um M-K
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.171-174
    • /
    • 2004
  • In order to improve the damage tolerance of the conventional laminated composites, three­dimensional fiber structures incorporated with stitching yams have been utilized in this study. From the newly developed process termed as TAPIS(TApe Placement Incorporated with Stitching), carbon/epoxy composites have been fabricated. Two-dimensional composites with the same stacking sequence as 3D counterparts have also been fabricated for the property comparison. To examine the damage resistance performance the low speed drop weight impact test has been adopted. For the assessment of damage after the impact loading, specimens were subjected to C-scan nondestructive inspection compression after impact(CAI) were also conducted to evaluate residual compressive strength. Although the damage area of 3D composites was greatly reduced$(30-40\%)$ compared with that of 2D composites, the CAI strength did not show drastic improvement.

  • PDF

Combined BOLD fMRI and Transcranial Magnetic Stimulation Study: Evaluation of Ipsilateral Motor Pathway of Stroke Patients

  • 배성진;장용민;장성호;변우목;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.104-104
    • /
    • 2001
  • Purpose: In this study, we investigated the possible motor pathways of hemiplegic stroke patients usin combined TMS and BOLD fMRI approach and evaluated the correlation between TMS a fMRI methods. Method: Four subjects, who demonstrated left hemiplegia after stroke, are included. TMS was performed using a Dantec Mag2 stimulator (Dantec Company, USA) in single puls mode with figure eight-shaped coil. Following TMS localization, The BOLD T2*-weight images were acquired with echo planar imaging sequence (TR = 1.2 sec, TE = 60 msec, and flip angle = 90). Motor activation was studied by means of a repetitive fing flexion-extension task. The stimulation protocol comprised 10 cycles of alternating activati and rest (10 images per cycle). Total 60 cycles were performed and each cycle take abou 1.5 sec. The resulting images were then analyzed with STIMULATE (CMRR, U, o Minnesota) to generate functional maps using a student t-test (p < 0.0005) and cluste analysis.

  • PDF

정상인의 두개내 자기공명분광법: 서로 다른 TE에 대한 같은 기종 내 및 다른 기종간의 정상 값의 비교

  • 백문영;조종운;조지연;박청수;이현용;신운재;은충기;문치웅
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.150-150
    • /
    • 2001
  • 목적: 두 종류의 MR 기종에서 정상 성인의 두개 내 Frontal White Matter와 Basal Ganglia를 대상으로 서로 다른 TE에 대해 MR 분광법을 시행하여 기종 내, 기종간의 정상 값의 차이가 있는지 알아보았다. 대상 및 방법: 신경학, 형태학적으로 이상이 없는 8명의 자원자(평균나이 24세)를 대상으로 하였고 지원자 개개인에게 두 개의 서로 다른 1.5T MR 기종(A, B기종)에서 각각 TE를 달리하여 Frontal White Matter, Basal Ganglia를 대상으로 MR 분광법을 시행하였다. 사용한 pulse sequence는 PRESS 방법이며, TR/TE는 3000/22(25),136(144)msec, 선택체적의 크기는 20$\times$20$\times$20(mm$^3$)로 하였다. MR 기종 A는 manual prescan, B는 automatic prescan을 이용하여 최적의 분광정보를 얻었다. 각각의 MR장치에서 얻은 분광 데이터는 본 기관에서 제작된 S/W로 PC에서 처리하여 각 대사물질 피크 면적의 NAA/Cr, Cho/Cr값을 구하였고, TE값에 따라 MR 기종 내 및 기종간의 정상 값의 차이가 있는지 알아보기 위해 Faired-Comparison t-test(p<0.05)를 이용하여 분석하였다.

  • PDF