• Title/Summary/Keyword: Test Field

Search Result 9,452, Processing Time 0.041 seconds

Thin Bonded Concrete Overlay for Concrete Pavement Rehabilitation (콘크리트포장의 박층 콘크리트 덧씌우기공법)

  • 윤경구;이형준;엄주용;서영찬
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.635-642
    • /
    • 1997
  • This research focused on the development of concrete overlay and test, which was conducted at 88 Highway 105k, 2 lanes of 290 m. The field application test consists of 6 cm and 10 cm bonded concrete overlay and 25 cm unbonded concrete overlay, using the slag cement for opening lanes for traffic early. The overlay were placed in a day. The whole period of traffic closing wes 8 day and it was reopened to traffic after concrete overlay has cured for 3 day. 5 cracks were founded when the field test section was investigated after 1 month, but all these may not make significant problems to overlay because these initiated and growed at the same line of repair section. The rideability and skid resistance become much better like in the new pavement after overlay. The structural capacity against deflection was much. which were verified by FWD(Falling Weight Deflectometer). The field test section is being used in a good condition and the results of field application and pavement performance analysis are encouraging. This rehabilitation methods may be adopted in Korea after a more field performance verifications.

  • PDF

Characterization of Durability of PC panel by Accelerating Test in Deterioration Chamber and Long-Term Field Exposure Test (촉진열화 및 장기폭로시험에 의한 고성능 PC패널의 내구성능 및 열화특성)

  • Ma, Sang-Joon;Jang, Pil-Sung;Choi, Jae-Suk;Ju, Jung-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1549-1554
    • /
    • 2008
  • In this paper, The evaluation of durability of the PC Panel lining for tunnel structure was examined through the rapid test by carbonation and freezing and thawing. Also for the purpose of improvement of durability. Namely, the durable characteristics of PC Panel lining by carbonation and freezing and thawing, was evaluated by rapid test and long-term field exposure test and main influence factors were derived. As a result of test, Correlation of accelerating test in deterioration chamber and long-term field exposure test, it will be expected that the proposed correlation well to the prediction of life expectancy of structure and is contributed greatly in the future.

  • PDF

The Estimation of Volume Conversion Factor of Rock Fill using Field Density Test (현장밀도시험을 이용한 암성토 체적환산계수 산정에 관한 연구)

  • Park, Jong-Beom;Ma, Myong-Soo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • In this study, the field density test was conducted as a volume conversion factor for the design of the excavation soil of the blasting rock. As a result of the field density test, the average volume conversion factor of rock was 1.001, which was smaller than the volume conversion factor of weathered rock 1.1. In the case of rock filled soil, the causes of the increase and decrease of the volume of the soil are provided by various phenomena. However, the specific techniques such as investigation and test methods are insufficient. Therefore, it was confirmed that the method of field density test is very useful method.

Filter Test for Detecting Partial Discharge in XLPE Cable (XLPE 케이블의 PD 검출 필터 시험)

  • Cho, Jae-Chul;Choi, Yong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.218-221
    • /
    • 2008
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under- ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektro- nix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

Performance Measurement of a Tubular Type Turbine System for Small Hydropower by Field Test (현장시험에 의한 소수력발전용 튜블러수차시스템 성능계측)

  • Hwang, Yeong-Ho;Lee, Young-Ho;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.6
    • /
    • pp.5-10
    • /
    • 2011
  • Recently, small hydropower attracts attention because of its renewable, clean and abundant energy resources to develop. Therefore, a tubular type hydro turbine is proposed for small hydropower in this study because the turbine has relatively simple structure and high possibility of applying to small hydropower. The purpose of this study is to investigate the performance characteristics of the turbine by field test. Field test iss conducted using one tubular turbine system as well as serial arrangement system by two tubular turbines taking into consideration of actual operation conditions. The results show that efficiency of test turbine changes considerably by the runner vane angle. Best efficiency of one turbine arrangement is higher than that of two turbine serial arrangement.

Filter Test for Detecting Partial Discharge in XLPE Cable (XLPE 케이블의 PD 검출 필터 시험)

  • Kim, Dae-Yeol;Yun, Ju-Ho;Choi, Yong-Sung;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.72-74
    • /
    • 2007
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as underground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

Filter Test for Detecting Partial Discharge in 22.9kV XLPE Cable (22.9kV XLPE 케이블 PD 검출용 필터 시험)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Kim, Seok-Jung;Lee, Kyoung-Yong;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2277-2279
    • /
    • 2005
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under-ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

The influence of model surface roughness on wind loads of the RC chimney by comparing the full-scale measurements and wind tunnel simulations

  • Chen, Chern-Hwa;Chang, Cheng-Hsin;Lin, Yuh-Yi
    • Wind and Structures
    • /
    • v.16 no.2
    • /
    • pp.137-156
    • /
    • 2013
  • A wind tunnel test of a scaled-down model and field measurement were effective methods for elucidating the aerodynamic behavior of a chimney under a wind load. Therefore, the relationship between the results of the wind tunnel test and the field measurement had to be determined. Accordingly, the set-up and testing method in the wind tunnel had to be modified from the field measurement to simulate the real behavior of a chimney under the wind flow with a larger Reynolds number. It enabled the results of the wind tunnel tests to be correlated with the field measurement. The model surface roughness and different turbulence intensity flows were added to the test. The simulated results of the wind tunnel test agreed with the full-scale measurements in the mean surface pressure distribution behavior.

Evaluation of Field Calibration Test on Rail for Train Wheel Force Measurement

  • Sim, Hyoung-Bo;Yeo, Inho
    • International Journal of Railway
    • /
    • v.8 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • An accurate measurement of the train-track interaction forces is important for track performance evaluation. In the field calibration test as a wheel load measurement process, the calibration system creates a different boundary condition in comparison with that in the train wheel passage. This study aims to evaluate a reliability of the field calibration test in the process of wheel load measurement. Finite element models were developed to compare the deformed shapes, bending moment and shear force profiles on the rail section. The analysis results revealed that the deformed shapes and their associated bending moment profiles on the rail are significantly different in two numerical simulations of the calibration test and the train wheel load passage. However, the shear stress profile on the rail section of the strain gauge installation in the field was almost identical, which may imply that the current calibration test is sufficiently reliable.

Safety Evaluation through Field Load Test of RC Slab Bridge (RC 슬래브 교량의 현장재하시험을 통한 안전성 평가)

  • Cho, Han-Min
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.9-13
    • /
    • 2022
  • Currently, RC slab bridges in use in Korea account for most of the total bridges, and bridges with a service life of 20 years or more account for about 75%. However, most of these RC slab bridges have a span of less than 20m and are not included in the first and second types of facilities, so maintenance is very neglected. Therefore, in this study, field load test is performed on an aged RC slab bridge, and the performance evaluation is performed based on the structural response results (deflection, impact coefficient, natural frequency, etc.) of the bridge obtained through field load test. In addition, the performance evaluation results obtained through the load test are intended to be used as basic data for the damage evaluation process of the bridge currently under development.