• Title/Summary/Keyword: Test Equipment

Search Result 3,418, Processing Time 0.031 seconds

Monitoring on Microbiological Contamination of Packed Ice Creams from Manufacturing Factories in Korea (국내 제조공장에서 생산된 아이스크림류의 미생물학적 오염실태 조사)

  • Heo, Eun-Jeong;Ko, Eun-Kyung;Kim, Young-Jo;Seo, Kun-Ho;Park, Hyun-Jung;Wee, Sung-Hwan;Moon, Jin San
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.202-206
    • /
    • 2014
  • In this study, the bacteriological survey was examined on ice creams at manufacturing factories in Korea during the summer season of 2011. The nineteen selected among 166 samples by preliminary test were collected from 11 different manufacturing factories in four major manufacturers in May 2011. Samples from ice milk, ice creams, sherbets, and non milk fat ice creams were tested for the total aerobic bacteria, coliform bacteria, and five food borne pathogens, respectively. The results showed that the coliforms including E. coli O157:H7, Salmonella spp., Staphylococcus aureus, Clostridium perfringens, and Listeria monocytogenes were not detected on all the ice creams. The total aerobic bacteria of the packed samples examined ranged between $2.5{\times}10^3$ and $5.5{\times}10^5cfu/g$. One ice cream, two sherbets, and four ice milk samples exceeded the acceptable limits of total aerobic bacteria according to the Korean standards for ice cream ($1.0{\times}10^5cfu/g$) and others ($5.0{\times}10^4cfu/g$). The levels of these microorganisms from ice creams were higher in three original equipment manufacturers than seven self-manufacturers. Three of ten ice creams (30.0%), three of six ice milks (50.0%), and one of two sherbets (50%) exceeded the acceptable limits of total aerobic bacteria, respectively. The personnel hygiene procedures with chocolate and vanilla chip addition from the manufacturing process were the main sources of the microbial contamination of stick-bar type ice creams when being produced in a factory. Improvement of the hazard analysis critical control points (HACCP) system should be introduced into the ice cream factory to improve the microbial quality of the ice cream products in Korea.

A Comparative Study on the CT Effective Dose by the Position of Patient's Arm (전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구)

  • Seong, Ji-Hye;Park, Soon-Ki;Kim, Jung-Sun;Park, Seung-Yong;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Purpose: In the whole body PET/CT scan, it is natural to lift the patient's arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had $^{18}F$-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as $6.33{\pm}0.93mSv$ for Biograph Sensation 16, $8.01{\pm}1.34mSv$ for Biograph Truepoint 40, and $9.69{\pm}2.32mSv$ for Discovery STe 8. When arms are located lower position, it was measure as $6.97{\pm}0.76mSv$, $8.95{\pm}1.85mSv$, $13.07{\pm}2.87mSv$ for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference ($p$<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

  • PDF

Self Production of Radioisotope and Radiopharmaceuticals Divider (방사성동위원소 및 방사성의약품 분주장치의 자체제작)

  • Hong, Sung-Tack;Park, Kwang-Seo;Kim, Seok-Ki;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.177-180
    • /
    • 2010
  • Purpose: As PET test came to be covered by the pay system of medical insurance (July 1, 2006) and the needs for it becoming increased for laboratory purpose, it became necessary to purchase expensive medical equipments to solve those problems. However, as most of equipments that are operated by cyclotron are very expensive as to amount from tens of millions up to hundreds of millions of won, it is difficult to purchase those equipments from the point of medical organizations. It may be possible to self manufacture those equipments with least costs if their parts functions that meets the operators demands. The Nuclear Medicine department of National Cancer Center (NCC) is trying to manufacture and use equipments that can be made with least costs, including introducing 2 medical equipments that can improves the operator's works. Materials and Methods: Example 1: Self production of radioisotope($^{18}F$) divider was fabricated. The NCC's Nuclear Medicine department acquired one acrylic panel, seven 3-way valve, tubing etc. that can be found in the market to make the main body of divider in cooperation with biomedical engineering, and placed them inside hot cell, and installed switching box outside of hot cell to make it possible to control them from outside. This main body of divider were placed in radioisotope transfer line that are manufactured in the cyclotron. Example 2: Self production of $^{18}F$-FDG automated divider was fabricated. The NCC's Nuclear Medicine department used cavro pump syringe that consists the main body of divider in cooperation with biomedical engineering, biomedical engineering developed programs that divides a certain amount. $^{18}F$-FDG automated divider is placed inside hot cell, and cable chords were used in the equipment, and then it was connected to PC outside hot cell to make it possible to control the $^{18}F$-FDG automated divider. Results: From the NCC's Nuclear Medicine department tests that were carried out from March, 2007 until now, we found out that radioisotope can be sent to radiopharmaceuticals composite module we want, and from the tests that are carried out at NCC's Nuclear Medicine department using $^{18}F$-FDG automated divider since August, 2009 it was possible to distribute radiopharmaceuticals into vial intended. Conclusion: Through the two examples above, we found out that costs can be reduced by self manufacturing expensive equipments from NCC's cyclotron room with least costs. Also, it decreased radiation exposure dose on workers, and set up problem solving processes in cooperation with lots of parties related.

  • PDF

Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam (PET/CT 검사 환자의 피폭선량 경감을 위한 연구)

  • Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.10-16
    • /
    • 2009
  • Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

  • PDF

Estimation of Evaporation Rate of Swine Slurry Using the Natural Evaporation System(NES) in summer (여름철 자연증발시스템(NES)의 腞슬러리 증발효율 평가)

  • Kim, K.Y.;Choi, H.L.;Kim, J.G.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.459-474
    • /
    • 2002
  • The purpose of this study was to establish the optimal operation condition of the natural evaporation system(NES) which was used for reducing swine slurry. Especially the main point of this study is to estimate the effect of climate condition(clear & rainy) and spray type(batch & flow) for the evaporation rate of swine slurry applying the NES in summer. Experiment was performed from June to August, which was generally regarded as summer in Korea, with the spray type of batch in 2000 and that of flow in 2001. As a result of experiment for batch and flow type, the averaged evaporation rate was measured into 2.71 and 3.59 l/ton . $m^2$ . day on clear days and 0.62 and 0.66 l/ton . $m^2$ . day on raint days, respectively. Based on the calculated evaporation rate by the climate condition and the spray type, it was proved that the averaged reduction rate for total input(1t/day) were 15.99% and 3.19% on clear and rainy days and the evaporation rate of the flow type was superior to that of the batch type by 5%, approximately. Therefore, it was concluded that the supplementary equipment, such as fan, should by operated in rainy days and the spray type of flow rather than that of batch should be recommended to increase the evaporation rate in the natural evaporation system(NES).

A study on the reduction on magnetic susceptible artifacts through the usage of silicon (실리콘을 이용한 자화율 인공물의 감소에 관한 연구)

  • Choi, Kwan-Woo;Lee, Ho-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5937-5942
    • /
    • 2012
  • This study used silicon that is similar to the density of the tissue of the human body to compensate for the uneven areas that are in contact with air in order to reduce susceptible artifacts. The subjects of the study were 16 normal people and the areas of the human body in which there are a lot of uneven areas with complicated structure and a lot of susceptible artifacts were formed since the surface area that comes into contact with the air is large were the areas that were chosen to be examined. A 3.0T superconducting magnetic resonance device was used as the test equipment and SPIR images that are sensitive to magnetic differences were obtained as sagittal planes on a line that extended the metatarsal and the phalanges, including the middle of the longitudinal arc and the 5 distal phalanxes. The method of analysis was to reduce the susceptibility between the tissue and the air to discover the reduction of susceptible artifacts by comparing the SNR and CNR before and after applying silicon. A statistical analysis was utilized for the sample matching T examination. The results of the study revealed that the susceptible artifacts were reduced in the images of the uneven areas that were compensated and applied with silicon. The SNR increased in significant amount in correlation from $3.91{\pm}1.33$ before application to $21.69{\pm}4.52$ after application and the CNR decreased in significant amount in correlation from $28.97{\pm}8.20$ before application to $4.88{\pm}2.14$. In conclusion, this study did not affect the voxel but it was an innovative method of improvement that compensated for the fundamental issue of the difference in susceptibility between the air and the body. The application is simple and the study has great significance in that it proposed a method to reduce susceptible artifacts in a low cost and highly efficient manner.

Economic Feasibility of Hill Land Development (산지개발(山地開發)의 경제성)

  • Kim, Dong-Min
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.11 no.4
    • /
    • pp.283-295
    • /
    • 1979
  • A new Farmland Expansion and Development Promotion Law was enacted in 1975. This law authorizes the Government to undertake development within a declared "reclamation area", wherever the land owners are unable to do so. In order to give additional impetus to conversion of waste hilly land into productive farmland, these hilly land development projects were conducted as large scale scheme which include soil fertility improvements such as the application of lime and phosphate. Farmland Expansion and Development Promotion Corps has attempted to undertake annual farm surveys in order to obtain some information about hilly land agriculture and farming operations within the reclamation project areas since 1976. As survey data accumulates, more and more clear picture of hilly land farming come to appear and enable us to conduct in-depth study. Effects of such upland reclamation include converting of previously unproductive slopeland into cultivable farmland for lucrative and commercial farming or food production. Furthermore, idle or marginal resources such as farm labor, equipment and compost would be fully employed. Socio-economic effects would include increases in land value and attitude change of farmers. On the other hand the preservation of natural environments might be damaged to the some extend by the projects. As shown in Table 7, the average farm size increased from 3,156 pyeong($3.3m^2$) to 5,562 pyeong, a 76.2% increase. The proportion of small farms with less than I ha dropped from 59.8% to 34.4%, but that of the large farms over 2 ha rose from 13.1% to 32.0% (See Table 8). The survey results indicate that as the farming on reclaimed uplands become time-honored, the acreage devoted for food crop production decreases against the economic crop growing acreage (see Table 6). For example, in the case of uplands reclaimed in 1972, the ratio of food crop acreages decreased from 99.7% in 1972 to 62.5% in 1977, whereas that of economic crop acreages increased from 0.3% in 1972 to 37.5% in 1977. The government used to actively encourage the farmers to carry out food crop production in the reclaimed upland targting toward the realization of self-sufficiency in food grains. It is, however, apparent that the farmers did hardly take the government advises as far as their economic interest were concerned. Yield per 10a. of various crops from the reclaimed uplands by year were surveyed as seen in Table 12. On the average, barley production in the reclaimed areas achieved 83.3% of the average unit yield from the existing upland in its 5 th year. Soybean yields showed a modest increase from 64% in the first year to 95%, in the 5 th year. In contrast, economic crops such as red pepper, totacco and radish achieved their maximum target yields in 3 years from starting to cultivate on the reclaimed farms. In order to test the post economic viability, an economic analysis was performed for each of selected subprojects on the basis of the data obtained through survey. The average actual internal economic rate of return on upland reclamation investments was found to be 20.3% which exceeded other types of projects of land and water development such as tidal land reclamation, irrigation or paddy rearrangement. The actual IRRs of subcategories of upland reclamation projects varied from 17.9% to 21.4% depending upon the kinds of cropping system adopted in each reclaimed areas such as food, economic, fruit or forage crops.

  • PDF

Pressure Drop Predictions Using Multiple Regression Model in Pulse Jet Type Bag Filter Without Venturi (다중회귀모형을 이용한 벤츄리가 없는 충격기류식 여과집진장치 압력손실 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Cho, Jae-Hwan;Jin, Kyung-Ho;Jung, Moon-Sub;Yi, Pyong-In;Hong, Sung-Chul;Sivakumar, S.;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2045-2056
    • /
    • 2014
  • In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags (Ø$140{\times}850{\ell}$) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design. The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2% which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore, the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity($V_f$), pulse pressure($P_p$), inlet dust concentration($C_i$), pulse interval($P_i$). Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5 m/min and inlet dust concentration less than $4g/m^3$. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than $4g/m^3$. When filtration velocity and pulse pressure were examined, operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than $5.8kgf/cm^2$. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min. Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than $7kgf/cm^2$, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure.

Investigation on Factors Influencing the Quality of Life of Arthritis Patients (관절염환자의 삶의 질에 영향을 미치는 요인탐색)

  • Oh, Hyun Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.3
    • /
    • pp.431-451
    • /
    • 2000
  • In this paper, I will examine the variables influencing the Quality of Life of arthritis patients and present basic materials which help arthritis patients have positive thinking in life and ultimately lead a satisfactory life. The subjects for this study are 231 inpatients and outpatients with arthritis living in J and K city in Chonbug Province. For the analysis of collected data I employed the SAS program. The variables for characteristics and the quality of life were analysed by descriptive statistics, T-test and ANOVA, and the relations among variables were analysed through Pearson Correlation; the Regression method was employed to predict the factors affecting quality of life. For the validity of reliance on measuring equipment Cronbach Alpha was used. The results of the study are as follows : (1) The mean score of quality of life of arthritis patients is 3.09(5 in the maximum). The general characteristics which affect the quality of life are age(F=5.13, p=0.0006), standard of education(F=6.49, p=0.0003), marriage status(F=7.77, p=0.0005), monthly pay(F=4.37, p=0.0020), medical benefits (F=4.85, p=0.0087), and supports(F=4.39, p=0.0050). For the disease-related characteristics, there is a significant difference in the 6 items: pain control method(F=5.92, p= 0.0002), physical therapy(F=3.25, p=0.013), whethere or not patients exercise(F=4.62, p=0.0000), regularity of exercise(F=4.79, p=0.0000), frequency of exercise(F=6.29, p=0.0001), and amount of exercise(F=4.62, p=0.0043). Depending on the type of arthritis, there is also a significant difference in the degree of pain felt. The patients with infectious arthritis suffer from pain the most, followed by those with gout, rheumatism and degenerative arthritis, in that order. Although statistics don't show any convincing evidence, those with gout perceive that they are in best health condition, followed by those with rheumatism, degenerative arthritis, and infectious arthritis, in that order(F=2.23, p=0.0669). (2) The quality of life of arthritis patients is correlated positively with perceived health status(r=0.56, p=0.0001), health promoting behavior(r=0.53, p=0.0001), family support (r=0.46, p=0.0001), amount of exercise (r=0.36, p=0.0001), ADL(r=0.36, p=0.0001), HLOC(r=0.32, p=0.0001), frequency of exercise(r=0.32, p=0.0001)in that order, while correlated negatively with the degree of pain felt(r=-0.32, p=0.0001), the number of pain regions(r=-0.19, p= 0.0041), and the duration of pain(r=-0.14, p=0.0279). (3) Regression analysis reveals that the most powerful predictor of the quality of life is perceived health status, which account for 31.11%. The other predictors of the quality of life, which account for 60.22%, are health promoting behavior(16.51%), family support(3.81%), ADL(2.52%), gender(1.86%), the number of family members(1.36%), level of pain(1.24%), duration of pain (1.08%), and level of education(0.67%). The results of the study show that perceived health status and health promoting behavior are the two most important variables. However, considering that the perceived health condition is difficult to control by nursing intervention, it is suggested that the level of expectation for patients, must be decided first, and the health promoting behavior and the family support influencing the quality of life must be taken into account as targets for nursing intervention. As a way of controlling the quality of life, I think that a more comprehensive approach comprising the above important variables along with demographic and general characteristics is needed. I also suggest that we must continue to explore the variables affecting the quality of life and include those variables in nursing intervention.

  • PDF

Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste (모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발)

  • Choi Jong-Seo;You Young-Hwan;Park Seung-Chul;Choi Seok-Mo;Hwang Tae-Won;Shin Sang-Woon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.110-120
    • /
    • 2005
  • For utilizing vitrification to treat low and intermediate level waste, industrial pilot plant was designed and constructed in October 1999 at Daejon, Korea through the joint research program among NETEC, MOBIS and SGN. More than 70 tests were performed on simulated IER, DAW etc. including key nuclide surrogate(Cs, Co); this plant has been shown to vitrify the target waste effectively and safely, however, some dust are generated from the HTF(High Temperature Filter) as a secondary waste. In case of long term operation, it is also concerned that pipe plugging can be occurred due to deposited dust in cooling pipe namely, connecting pipe between CCM(Cold Crucible Melter) and HTF. In this regard, we have developed the special complementary system of the off-gas treatment system to recycle the dust from HTF to CCM and to remove the interior dust of cooling pipe. Main concept of the dust recycling is to feed the dust to the CCM as a slurry state; this system is regarded as of an important position in the viewpoint of volume reduction, waste disposal cost and glass melt control in CCM. The role of DRS(Dust Recycling System) is to recycle the major glass components and key nuclides; this system is served to lower glass viscosity and increase waste solubility by recycling B, Na, Li components into glass melt and also to re-entrain and incorporate into glass melt like Cs, Co. Therefore dust recycling is helpful to control the molten glass; it is unnecessary to consider a separate dust treatment system like a cementation equipment. The effects of Dust Cleaner are to prevent the pipe plugging due to dust and to treat the deposited dust by raking the dust into CCM. During the pilot vitrification test, overall performance assessment was successfully performed; DRS and Dust Cleaner are found to be useful and effective for recycling the dust from HTF and also removing the dust in cooling pipe. The obtained operational data and operational experiences will be used as a basis of the commercial facility.

  • PDF