• Title/Summary/Keyword: Test Cost

Search Result 3,991, Processing Time 0.036 seconds

The Selection of Optimal Mixing Proportion and Cost Analysis in the SFC (초유동 콘크리트의 최적배합 선정방법 및 경제성 분석)

  • Park, Chil-Lim;Kim, Moo-Han;Kwon, Yeong-Ho;Lee, Sang-Soo;Won, Cheol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.262-268
    • /
    • 1998
  • This research is to examine the selected method of optimal mixing proportion and cost analysis in the super flowing concrete. As confined water $ratio($\beta_p$)$ and K is introduced, itis to establish optimal mixing design of super flowing concrete according to the steps of paste, mortar and concrete. From paste and mortar test, it was led to $$\beta_p$$ and $K_p$satisfying the optimum condions depending on the kinds of binders. Then $$\beta_p$$ and $K_p$ is reflected to the mix condition of super flowing concrete. The result of test, the mix condition of super flowing concrete satisfied the quality performance of concrete with adjustment of additional rate of the superplasticizer. Besides, in case of design strength $350kg/\textrm{cm}^2$ of concrete, material cost in super flowing concrete is able to be reduced 5~16% in replacement of fly ash 30% in ordinary portland cement and slag cement.

  • PDF

EXPLORING THE FUEL ECONOMY POTENTIAL OF ISG HYBRID ELECTRIC VEHICLES THROUGH DYNAMIC PROGRAMMING

  • Ao, G.Q.;Qiang, J.X.;Zhong, H.;Yang, L.;Zhuo, B.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.781-790
    • /
    • 2007
  • Hybrid electric vehicles(HEV) combined with more than one power sources have great potential to improve fuel economy and reduce pollutant emissions. The Integrated Starter Generator(ISG) HEV researched in this paper is a two energy sources vehicle, with a conventional internal combustion engine(ICE) and an energy storage system(batteries). In order to investigate the potential of diesel engine hybrid electric vehicles in fuel economy improvement and emissions reduction, a Dynamic Programming(DP) based supervisory controller is developed to allocate the power requirement between ICE and batteries with the objective of minimizing a weighted cost function over given drive cycles. A fuel-economy-only case and a fuel & emissions case can be achieved by changing specific weighting factors. The simulation results of the fuel-economy-only case show that there is a 45.1% fuel saving potential for this ISG HEV compared to a conventional transit bus. The test results present a 39.6% improvement in fuel economy which validates the simulation results. Compared to the fuel-economy-only case, the fuel & emissions case further reduces the pollutant emissions at a cost of 3.2% and 4.5% of fuel consumption with respect to the simulation and test result respectively.

An Experimental Study on Penetration Resistance of Styrofoams Mounted on Falling Prevention Net for Re-bar (스티로폼이 거치된 낙하물방지망의 철근 낙하에 대한 관통 저항성 실험)

  • Son, Ki-Sang;Jeon, Soo-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.95-98
    • /
    • 2012
  • There are many high-rise apartment building construction in Korea. There was an accident to pass through worker head by rebar dropped from height place. Therefore, low cost-high effectiveness method to prevent this type of accident should be revised and applied into the construction site. This study is to find out which method could be effectively applied to a site with low cost. Practical field test at 4th floor, 10th floor of apartment building site using re-bar diameter D10, D13, D16, D19, D22 with a length of 1 m, 1.5 m, 2 m, 2.5 m, 3 m which are common by used in a site. The test has also been done with a cover of styrofoam thickness 4.5 cm and thickness 9cm on field drop preventing net. One sheet of styrofoam thickness 45 mm has approximately two times stronger than only prevention net, It is found. Also, Two sheets have approximately two times stronger than one sheet of it.

Factors Related to Surgical Site Infections in Patients Undergoing General Surgery (일반외과 환자의 수술부위 감염 관련 요인 분석)

  • Ahn You-Jin;Sohng Kyeong-Yae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.12 no.1
    • /
    • pp.113-120
    • /
    • 2005
  • Purpose: To identify risk factors for surgical site infections in patients undergoing general surgery, to analyze the prolonged hospital stay and extra cost for antibiotics, and to provide basic data for control of surgical site infections. Method: Surgical site infection was defined using the definition of the CDC and the data were analyzed by $x^2$-test and unpaired t-test. Results: The prevalence of surgical site infections was 9.7%, and it was related to wound class, duration of operation, number of operations, whether the operation was an emergency, trauma, drains, preoperative stays, presence of remote infection during operative period, and previous history of recent surgery. The mean duration for post-operative stay when a surgical site infection occurred was 9.5 days and in 56.9 % of the patients the surgical site infection appeared 7 days after the operation. Post-operative stays for infected patients were 20.3 days longer than that of uninfected patients. The mean cost of antibiotics for infected patients was higher than that for uninfected patients by 561,067 won per person. Conclusion: Surgical site infection results in an increased length of stay and extra-cost, thus, hospitals need to create strategies to reduce nosocomial infections through effective infection surveillance and by considering factors related to surgical site infections.

  • PDF

The transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment used for electrical durability test for magnetic switch (IEC60947-4에 따른 전자개폐기 전기적 수명시험설비의 과도현상을 고려한 SCR최적 정격선정에 대한 연구)

  • Ryu Haeng Soo;Kim Kab Dong;Han Gyu Hwan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.354-356
    • /
    • 2004
  • This paper is the transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment(AC3 TE) used for electrical durability test for magnetic switch according to IEC60947-4 Annex B by utilizing EMTP -ATPDraw. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. The key cost of AC3 TE is the SCR ratings. The more decreases SCR ratings, the more decreased the cost is, but it is impossible to ensure the reliability. On the other hand, the more increases SCR ratings, the more increased the cost is. Thereupon, in this paper after the testing circuit is simulated by using EMTP-ATPDraw the SCR ratings will be applied in order to guarantee the testing reliability of PT&T(Power Testing and Technology institute in LG Industrial Systems Co.,Ltd.).

  • PDF

A design of High-Profile IP for H.264 (H.264 High-Profile Intra Prediction 설계)

  • Lee, Hye-Yoon;Lee, Young-Ju;Kim, Ho-Eui;Suh, Ki-Bum
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.112-115
    • /
    • 2008
  • In this paper, we propose H.264 High Profile Encoder Intra Prediction module. This designed module can be operated in 306 cycle for one-macroblock. To verify the Encoder architecture, we developed the reference C from JM 13.2 and verified the our developed hardware using test vector generated by reference C. We adopt plan removal and SAD calculation to reduce the Hardware cost and cycle. The designed circuit can be operated in 133MHz clock system, and has 250K gate counts using TSMC 0.18um process including SRAM memory.

  • PDF

A Study on Fatigue Characteristics and Economic Analysis of Discharged Nylon Fiber-Reinforced Asphalt Concrete (폐나일론을 이용한 섬유보강 아스팔트 콘크리트의 피로특성 및 경제성 분석)

  • Baek, Ingyu;Park, Kisun;Kim, Nakseok
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.476-483
    • /
    • 2013
  • In this study, discharged nylon fibers were added to asphalt concretes to be compared with fatigue life and analyzed in economic point of view. A four point bending fatigue test was conducted, and as a result, nylon fiber reinforced asphalt concretes that showed a 10percent increase in fatigue life compared to ordinary asphalt concrete. The economic analysis confirmed that the maintenance cost was decreased by 540 million won throughout the analyzing period. It is thought discharged nylon fiber reinforced asphalt will cause more economic and social effects than was shown by life cycle cost analysis.

DEVELOPMENT OF A GARLIC CLOVE PLANTER

  • Park, W.K.;Kim, Y.K.;Choi, D.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.438-445
    • /
    • 2000
  • Positioning garlic cloves in upright standing in garlic field has been regarded as a very important job because it affects clove rooting, growing and, eventually, quality and yield in garlic production, Because of the geometrical uniqueness and irregularity of garlic cloves in shape, the planting operation has been conducted by manual work that needs a tremendous human labors and increases garlic production cost. The overall objective of this research was to develop garlic planting machine through investigating physical properties of garlic and designing clove upright positioning device after figuring out the factors affecting metering device and upright clove positioning mechanism. With the outcomes of the metering and posture positioning experiment, a garlic clove planter having twelve planting rows was developed for 37kW type tractor and feasibility test was carried out in the field. And, According to the performance test and cost analysis, the planter could accomplish planting operation of one hectare plot in 6.3 hours giving 48 times better efficiency, 6.3hrs/ha, and 74.2% of production cost reduction effect, 1,092,546won/ha, than the manual works of 299hrs/ha and 282,258won/ha. And, break-even point ofthe planter was calculated as of 2.71 hectares.

  • PDF

The Assessment of Cost-Analysis and Centralization Needs in Elementary School Foodservices in Kyungki-do (초등학교 급식소의 급식비용분석 및 공동작업 요구도 조사 -경기도 지역을 중심으로-)

  • 유양자;윤선주
    • Korean journal of food and cookery science
    • /
    • v.14 no.1
    • /
    • pp.57-67
    • /
    • 1998
  • The main purpose of this study was to provide a basic information for the efficient foodservice management in elementary schools. A survey was conducted to get the information on the cost management and centralization needs of dietitians working for school foodservice in Kyungki-do. Detail information was collected from 85 dietitians. Statistical data analysis was completed using the SPSS/PC/sup/+ package for descriptive analysis, t-test, $\chi$$^2$test and ANOVA. The results of this study were as follows: 1. Meal costs per one person evaluated on the standards of monthly budget basis in May and June, 1996 did not show any significant differance between commisary foodservice schools and conventional ones. Labor costs of island type and rural type were significantly higher than those of urban type. The schools with less than 1,000 feeding numbers spent more labor costs than those with over 1,001-feeding numbers did. 2. In island type and rural type, total meal costs increased according as the scale of the schools decreased. 3. Results of the survey on dietitians' centralization noeds showed that the aspects of common-purchasing and common solid waste management marked the highest ratings, whereas the aspects of commissary foodserice system got the lowest rating.

  • PDF

Managerial Effectiveness of Integrated Delivery System in Japan (의료서비스 복합화의 경영효과 분석 : 일본의 사례)

  • Jeong, Seung-Won;Inoue, Yusuke;Seo, Young-Joon;Kim, Yun-Hee
    • Korea Journal of Hospital Management
    • /
    • v.14 no.2
    • /
    • pp.60-74
    • /
    • 2009
  • This study purports to verify managerial effectiveness of the integrated delivery system(IDS) of Japanese health care institutions through comparing the managerial performance between hospital groups providing with both acute and nursing care and those with acute care only. Data on the managerial performance of 697 hospitals providing with nursing care together and 819 hospitals providing with acute care only were collected from Japanese Central Social Insurance Medical Councils 2001, 2003, 2005, and were analyzed using mean comparison test(t-test) between the two groups. The results revealed that there were significant differences between the two groups in such indicators as ratio of material cost, labor cost, depreciation rate, total margin, operating margin, average number of outpatient per day, average revenue of an inpatient per day, total amount of labor cost, gross revenue per employee, and labor productivity. However, we could not find out any consistent evidence which support the effect of integrated delivery system on the hospital managerial performance. Further discussion was made on the limitation of the study and future research agenda relevant to the topic.

  • PDF