• Title/Summary/Keyword: Test Cost

Search Result 3,991, Processing Time 0.037 seconds

Study on the Mechanical Properties of Power Metallurgy Spline Hub for Clutch Disc (클러치 디스크용 분말야금 스플라인 허브의 기계적성질에 관한 연구)

  • 최문일;장진호;강성수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.104-110
    • /
    • 1998
  • In automotive industries, various processes for the cost reduction have been investigated lively. As one of them, powder metallurgy becomes influential. Compared to other methods used for he manufacture of steel components the Powder metallurgy process is competitive primarily due to the small number of production steps to reach the final geometry and thereby also the energy-efficiency. In this paper, to alter present forging process into powder metallurgy process by which the automotive clutch disc spline hub is manufactured machining process, the mechanical properties of sintered materials is investigated by specimen test. Selecting the 3 kinds of materials-SMF 4040, SMF 9060 and DHP-1, their properties according to heat treatment such as carburizing -tempering and plasma-nitrodizing are compared. By result of specimen test - tensile test, compression ring test, Impacting test, measurment of hardness, and microstructure analysis - we concluded that SMF 9060 and carburizing-tempering heat treatment is an optimal material and heat treatment method for the spline hub. It will be able to reduce manufacturing cost and weight.

  • PDF

Acceleration Test of Membrane-Electrode Assembly in PEMFC (고분자연료전지의 전해질-전극 접합체의 열화 가속시험)

  • Lee, Jung-Hun;Yoon, Young-Gi;Jung, Eun-Ha;Lee, Won-Yong;Kim, Chang-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.93-96
    • /
    • 2007
  • Recently, much attentions have been paid on the commercialization of PEMFC, especially for the applications of residential and portable. In order to achieve the early commercialization of PEMFC, thee are two hurdles to overcome. One is cost down and the other is improvement of durability of the system components. Numerous companies have tried to reduce the production cost and the main research topics have been changed from performance to durability improvement. In this work, acceleration test were performed to find and evaluate the main reason of degradation of the MEA(membrane-electrode assembly) which is one of the core component of the PEMFC system. Based upon the test results, a way to make durable MEA was suggested. Acceleration tests were made by applying high voltage of 1.2V to the several kinds of single cells to increase the growth of catalyst particles. Cell performance, ac-impedance and electrochemically active area measurements were made atfter every 8 hours of acceleration test. Degradations of catalyst and membrane were examined by SEM, TEM and XRD. Obtained results were discussed in terms of structural stability and loss of catalyt and ionomers in the electrode layer. In addition, the way to make highly durable MEA was suggested.

  • PDF

Calculation of Tree Height and Canopy Crown from Drone Images Using Segmentation

  • Lim, Ye Seul;La, Phu Hien;Park, Jong Soo;Lee, Mi Hee;Pyeon, Mu Wook;Kim, Jee-In
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.6
    • /
    • pp.605-614
    • /
    • 2015
  • Drone imaging, which is more cost-effective and controllable compared to airborne LiDAR, requires a low-cost camera and is used for capturing color images. From the overlapped color images, we produced two high-resolution digital surface models over different test areas. After segmentation, we performed tree identification according to the method proposed by , and computed the tree height and the canopy crown size. Compared with the field measurements, the computed results for the tree height in test area 1 (coniferous trees) were found to be accurate, while the results in test area 2 (deciduous coniferous trees) were found to be underestimated. The RMSE of the tree height was 0.84 m, and the width of the canopy crown was 1.51 m in test area 1. Further, the RMSE of the tree height was 2.45 m, and the width of the canopy crown was 1.53 m in test area 2. The experiment results validated the use of drone images for the extraction of a tree structure.

FDR Test Compression Algorithm based on Frequency-ordered (Frequency-ordered 기반 FDR 테스트패턴 압축 알고리즘)

  • Mun, Changmin;Kim, Dooyoung;Park, Sungju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.5
    • /
    • pp.106-113
    • /
    • 2014
  • Recently, to reduce test cost by efficiently compressing test patterns for SOCs(System-on-a-chip), different compression techniques have been proposed including the FDR(Frequency-directed run-length) algorithm. FDR is extended to EFDR(Extended-FDR), SAFDR(Shifted-Alternate-FDR) and VPDFDR(Variable Prefix Dual-FDR) to improve the compression ratio. In this paper, a frequency-ordered modification is proposed to further augment the compression ratios of FDR, EFDR, SAFRD and VPDFDR. The compression ratio can be maximized by using frequency-ordered method and consequently the overall manufacturing test cost and time can be reduced significantly.

Long Term Evaluation of UF Membrane process using River-bed Water (복류수를 이용한 한외여과공정의 장기운전 평가)

  • Kim, Chung H.;Lim, Jae L.;Kang, Suk H.;Kim, Su H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.429-436
    • /
    • 2008
  • Membrane system has been increasingly considered as a safe and cost-effective water treatment process especially in case of small scale water works. This research is a basis of membrane application in water works through a long period test with obtaining operation skills and evaluation of water quality and cost competitiveness. For the research, the UF membrane system was installed in small water treatment plant that uses river-bed water as raw water. The system was consisted of 2 stage membrane and operated in constant flow mode (Flux: 1.5, 1.0, 0.9, 0.6). In each different flux condition, TMP trends were showed better results at lower flux condition. And through the high flux condition test, it is certified that membrane system could deal with breakdown of one stage. Water quality of permeate was satisfied the water quality standards especially turbidity. To know what mainly causes fouling on membrane, the test by membrane with several cleaning agents and EDX analysis have done in lab. Through the tests, ferrous concentration in raw water, backwashing water and membrane surface etc. was high and it causes fouling inside and outside of membrane. So acid cleaning using organic acid such as oxalic acid is necessary in Chemical in Place (CIP). At the economical aspect the electrical cost of membrane system is higher than that of slow sand filtration but labor cost can be reduced by automation. However, the use of labor should be determined considering effectiveness and stability of operation. Because during the operation, there are several breakdown such as electrical shock by lightning, water drop in summer, etc.

A Study on the Evaluation of Dynamic Behavior and Liquefaction Cau8ed by Earthquake of Sea Dike Structures on the Ground (방조제 축조 예정지반의 지진에 의한 액상화 거동 평가)

  • 도덕현;장병욱;고재만
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.2
    • /
    • pp.43-56
    • /
    • 1993
  • The laboratory tests are performed on how the liquefaction potential of the sea dike structures on the saturated sand or silty sand seabed could be affected due to earthquake before and after construction results are given as follows ; 1. Earthquake damages to sea dike structures consist of lateral deformation, settlement, minor abnormality of the structures and differential settlement of embankments, etc. It is known that severe disasters due to this type of damages are not much documented. Because of its high relative cost of the preventive measures against this type of damages, the designing engineer has much freedom for the play of judgement and ingenuity in the selection of the construction methods, that is, by comparing the cost of the preventive design cost at a design stage to reconstruction cost after minor failure. 2. The factors controlling the liquefaction potential of the hydraulic fill structure are magnitude of earthquake(max. surface velocity), N-value(relative density), gradation, consistency(plastic limit), classification of soil(G & vs), ground water level, compaction method, volumetric shear stress and strain, effective confining stress, and primary consolidation. 3. The probability of liquefaction can be evaluated by the simple method based on SPT and CPT test results or the precise method based on laboratory test results. For sandy or silty sand seabed of the concerned area of this study, it is said that evaluation of liquefaction potential can be done by the one-dimensional analysis using some geotechnical parameters of soil such as Ip, Υt' gradation, N-value, OCR and classification of soils. 4. Based on above mentioned analysis, safety factor of liquefaction potential on the sea bed at the given site is Fs =0.84 when M = 5.23 or amax= 0.12g. With sea dike structures H = 42.5m and 35.5m on the same site Fs= 3.M~2.08 and Fs = 1.74~1.31 are obtained, respectively. local liquefaction can be expected at the toe of the sea dike constructed with hydraulic fill because of lack of constrained effective stress of the area.

  • PDF

Weak D Testing is not Required for D- Patients With C-E- Phenotype

  • Choi, Sooin;Chun, Sejong;Lee, Hwan Tae;Yu, HongBi;Seo, Ji Young;Cho, Duck
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.585-590
    • /
    • 2018
  • Background: Although testing to detect weak D antigens using the antihuman globulin reagent is not required for D- patients in many countries, it is routinely performed in Korea. However, weak D testing can be omitted in D- patients with a C-E- phenotype as this indicates complete deletion of the RHD gene, except in rare cases. We designed a new algorithm for weak D testing, which consisted of RhCE phenotyping followed by weak D testing in C+ or E+ samples, and compared it with the current algorithm with respect to time and cost-effectiveness. Methods: In this retrospective study, 74,889 test results from January to July 2017 in a tertiary hospital in Korea were analyzed. Agreement between the current and proposed algorithms was evaluated, and total number of tests, time required for testing, and test costs were compared. With both algorithms, RHD genotyping was conducted for samples that were C+ or E+ and negative for weak D testing. Results: The algorithms showed perfect agreement (agreement=100%; ${\kappa}=1.00$). By applying the proposed algorithm, 29.56% (115/389 tests/yr) of tests could be omitted, time required for testing could be reduced by 36% (8,672/24,084 min/yr), and the test cost could be reduced by 16.53% (536.11/3,241.08 USD/yr). Conclusions: Our algorithm omitting weak D testing in D- patients with C-E- phenotype may be a cost-effective testing strategy in Korea.

Variations of Building Methods and Costs of Modernized Hanok Test-bed Projects (실증구축을 통한 신한옥의 신공법 및 공사비 변화 요인 도출)

  • Seo, Nuri;Kang, Seunghee;Lee, Yunsub;Jin, Zhenhui;Jeong, Yeheun;Jung, Youngsoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.3
    • /
    • pp.86-96
    • /
    • 2019
  • The research efforts to modernize Hanok (Korean traditional housing) have been performed to improve the quality and cost-effectiveness through application of modern building methods and materials, and to disseminate it in various forms of sizes and facilities. In this study, in order to identify the variations of modernized Hanok, data from seven test-bed projects are analyzed based on the building work-section, element, method, and material. The data were standardized and managed through the modernized Hanok classification system (Hanclass) to facilitate systematic comparisons of the test-bed projects by the variation of building method and it's cost impact. Identified factors of the variation in terms of building methods were then itemized and quantified in terms of building cost. Findings of this study indicate that the timber structure is the most critical area for future variation for improving the quality and cost-effectiveness. The results of this study will be also used to systemize the Hanok database for further studies.

Limited Cost-Based Competition and the Cost Distortion Factor - How Real Variable Costs are Reported in Cost-Base Pool of Korean Power Market - (원가기반 제한경쟁과 비용왜곡 요인 -변동비 반영 전력시장에서의 실제변동비 반영사례를 중심으로-)

  • Kim, Myung-Seok;Cho, Sung Bong
    • Environmental and Resource Economics Review
    • /
    • v.23 no.3
    • /
    • pp.497-513
    • /
    • 2014
  • Rate-of-return regulation where a regulator compensates the utilities based upon the cost incurred the regulated companies have the incentive to over-report cost level. However, in case of cost-based competition where a regulator knows the cost of each plant involved and induce the competition among them, one can encounter prisoner's dilemma situation in the short run where the regulated firms under-report cost level. For instance, in case of cost-based pool, a generator may have a strategic behavior to keep its registered variable cost higher than the actual level to maintain its operation rate and generation amounts higher. Eventually, however, such behavior decrease the profitability of a generator and discourage new entry jeopardizing required level of capacity reserves. This is a typical Prisoner's Dilemma situation. The power market operating rule should be revised so that generators' registered variable cost reflect actual level of variable cost.

A study on the total housing cost of households living in rental house (임차가구의 주거비용에 관한 연구)

  • 곽인숙;김순미
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.2
    • /
    • pp.127-144
    • /
    • 1999
  • The purposes of this study were to identify the housing maintenance cost, imputed rent fee and total housing cost of households living in rental house, to analyze the factors related to their housing maintenance cost, imputed rent fee and total housing cost and to investigate the factors contributing to total housing cost to total household income ratio. The data used for these purposes, was 97 KHPS of Daewoo Economic Research Institute. Sample size of households living in rental house, was 663. Statistics performed for the analysis were frequencies, percentiles, t-test, Lorenz cutie and Gini coefficient, Tobit analysis, OLS and Logistic analysis. The results of this study were as fellows: First, monthly cost of monthly rent & maintenance and repairs of households living in rental house with a deposit was lower than rental house, while the imputed rent fee of households living rental house with a deposit was higher than monthly rent households'And, total housing cost of households living in rental house with a deposit was higher than monthly rent households'. Second, Gini coefficient of the housing maintenance cost was 0.440, Gini coefficient of imputed rent fee was 0.362, and Gini coefficient of total housing cost was 0.291. Third, the variables related to their housing maintenance cost were family type, total household expenditure of socio-demographic characteristics and residence, type of rent, housing type of housing environmental factor. Also, the variables contributing to imputed rent fee were job type and educational attainment of household hearts, the number of family members, total household expenditure, residence, type of rent, housing type and tole number of rooms. In addition, the variables associated with total housing cost were job type and educational attainment of household head, total household income and residence, type of rent, housing type and the number of room. Finally, age, job type, educational attainment of household head, wife's employment status, the number of family members, family type, total household expenditure, residence, rent type of rent, housing type, the size of living space, and the number of room were significant variables contributing to total household cost to total household income ratio.

  • PDF