• Title/Summary/Keyword: Test Cost

Search Result 3,991, Processing Time 0.035 seconds

A Study on Performance Characteristics of Propane/Isobutane Refrigerant Mixtures in a Domestic Small Multi-Refrigeration System (프로판/이소부탄(R-290/R-600a) 혼합 냉매를 적용한 가정용 소형 멀티 냉동시스템의 성능특성에 관한 연구)

  • Kim Sanguk;Lee MooYeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.271-278
    • /
    • 2005
  • In this paper, the performance of Kim-chi refrigerator with three evaporator and one compressor was investigated in employing $55\%$ propane and $45\%$ isobutane (R290/R600a) refrigerant mixture as an alternative refrigerant of R134a. The drop-in test was performed by varying both refrigerant charge and capillary tube length in order to find both the performance and reliability of a small multi-refrigeration system. Results show that the power consumption is decreased by about $15\%$ and COP is increased by about $10\%$, respectively as compared to the baseline system using R-134a. In addition, the propane/isobutane refrigerant mixture system took advantage of the minimization of modification and redesigning of system components because thermodynamic properties such as saturation pressure, temperature, normal boiling point(NBP) characteristics are similar to those of R134a. The reduction of sales cost is caused by the decrease of refrigerant cost per unit mass and refrigerant charge amount necessary for the refrigeration system.

A study on embedded & wireless fault code transmission device development for railroad vehicle (철도차량용 임베디드 무선전송장치의 개발에 관한 연구)

  • Kim, Jong-Keol;Shim, Ja-Hyun;Shon, Kang-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1255-1261
    • /
    • 2010
  • An operating information and fault recode of train is very important information for safety driving and maintenance. And these information is increased and need high speed as the number of trains is increased. Wireless LAN or CDMA network is efficient to report more complicated and various information from vehicle to server in control center. Existing wireless transmission system has weakness due to transmission system is separated with TDCS and standalone. At first, standalone system needs space to be installed and cost is increased. And data transmission capacity and speed is limited by complicated structure that transmission system receive data thru serial communication like RS232 and then data transmission system send data to server in control center. This article is study to develop embedded & wireless fault code transmission device to be installed in TDCS to overcome weakness of space and to have more cost effective and simple structure. It is adapted 802.11b/g WiFi for wireless communication and OS is used embedded Linux that can easily implement wireless communication environment and ensure TCP/IP communication’s security. We also implement simple server to test wireless communication between embedded & wireless fault code transmission device and server in control center.

  • PDF

Application of Energy Storage System for Industrial Customer (산업용 수용가의 에너지저장장치 적용)

  • Hong, Jong-seok;Chai, Hui-seok;Kang, Byoung-wook;Kim, Tae-hyeong;Kim, Jae-chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.992-998
    • /
    • 2015
  • The ESS is composed of Battery Package, PCS(Power Conditioning System) Package, BCU(BESS Control Unit). In Jeju smart grid test-bed, we have developed a business model by ESS power system, renewable energy, transportation, such as customers, and have demonstrated above things. We have analyzed the EMS(Energy Management System) model of KPX where manages supply and demand of domestic electrical power system. We modified and launched EMS for microgrid but the cost was expensive and the system was large size. For releasing this system from industry as a whole, it is imperative to develop PMS(Power Management System) for microgrid. However, the cost of EMS for microgrid is expensive, some systems because it is a large development of the all of the first fruits in urgent PMS(Power Management System) for microgrid to be used in industry in general. Therefore, in this paper, we propose the ESS model considering the power systems characteristics and extensibility in korea. and also we propose the PMS to manage the ESS systems.

Impermeable Standards for the Concrete Bottom of Dikes for Crude Oil Storage Tanks (원유저장탱크 방류벽의 콘크리트 바닥재 불침투성 세부기준 연구)

  • Shin, Changhyun;Park, Jai Hak;Yoon, Junheon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.54-60
    • /
    • 2016
  • The bottom of dikes must be kept impermeable to control hazardous chemicals spilled from storage tanks. Currently, insufficient related chemical control laws lead to a possibility to spread through the bottom. Generally, due to the high cost of installation and periodical maintenance, many businesses prefer to install the bottom with general concrete. But, since the impermeability of concrete is dependent on the kind of materials and chemical reaction, all concrete cannot be considered as impermeable material. Thus, it is necessary to make the installation standards of the dike bottom clear in order to avoid the argument over the impermeability and prevent the chemical accident. This study has suggested the standards of impermeable concrete by conducting 7-day exposure test to crude oil with the pilot dikes. The results have showed that the standards have the better impermeable performance compared with the germany standard, which have been penetrated at the maximum penetration depth of 1.9 cm. This study is expected to contribute to both the risk reduction of penetrating into the bottom and the cost reduction of spending to make the bottom of dikes impermeable.

A multi-parameter optimization technique for prestressed concrete cable-stayed bridges considering prestress in girder

  • Gao, Qiong;Yang, Meng-Gang;Qiao, Jian-Dong
    • Structural Engineering and Mechanics
    • /
    • v.64 no.5
    • /
    • pp.567-577
    • /
    • 2017
  • The traditional design procedure of a prestressed concrete (PC) cable-stayed bridge is complex and time-consuming. The designers have to repeatedly modify the configuration of the large number of design parameters to obtain a feasible design scheme which maybe not an economical design. In order to efficiently achieve an optimum design for PC cable-stayed bridges, a multi-parameter optimization technique is proposed. In this optimization technique, the number of prestressing tendons in girder is firstly set as one of design variables, as well as cable forces, cable areas and cross-section sizes of the girders and the towers. The stress and displacement constraints are simultaneously utilized to ensure the safety and serviceability of the structure. The target is to obtain the minimum cost design for a PC cable-stayed bridge. Finally, this optimization technique is carried out by a developed PC cable-stayed bridge optimization program involving the interaction of the parameterized automatically modeling program, the finite element structural analysis program and the optimization algorithm. A low-pylon PC cable-stayed bridge is selected as the example to test the proposed optimization technique. The optimum result verifies the capability and efficiency of the optimization technique, and the significance to optimize the number of prestressing tendons in the girder. The optimum design scheme obtained by the application can achieve a 24.03% reduction in cost, compared with the initial design.

Design of Dissolution Apparatus for the Flow-through Cell Method Based on the Low Pulsation Peristaltic Pump (저 맥동 연동 펌프 기반 플로우 스루 셀 방식 용출 장치 설계)

  • Zhao, Jun Cheng;Cheng, Shuo;Piao, Xiang Fan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.1
    • /
    • pp.11-18
    • /
    • 2020
  • The emergence of the flow-through cell (FTC) method has made up for the limitations of previous dissolution test methods, but the high cost of the FTC dissolution devices have seriously hindered the progression of research and application of the FTC. This new design uses a peristaltic pump to simulate the sinusoidal flow rate of a piston pump. The flow profile of each peristaltic pump was sinusoidal with a pulsation of 120 ± 1 pulses per minute, and the flow rate ranged from 1.0 - 36.0 mL/min. The flow control of each channel was adjusted independently so the flow errors of the seven channels were close to 2%. The structure of the system was simplified, and the cost was reduced through manual sampling and immersing the FTC in a water bath. The dissolution rate of the theophylline and aminophylline films was determined, and good experimental results were obtained.

Analysis of the Correlation Between the Density of the Hydrometer Method and Fly Ash Fineness in Acceptance Inspection (인수검사시 Hydrometer법의 밀도 값과 플라이애시의 분말도간 상관관계 분석)

  • Moon, Byeong-Yong;Hyun, Seong-Yong;Lee, Jae-Jin;Song, Heung-Ho;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.20-21
    • /
    • 2017
  • There have been reports in the media about some refineries that omit the refining process and deliver raw material for reasons of cost reduction, shortening of production time, etc. Also, in most RMC factories acceptance inspection is not conducted on account of issues with the proficiency of the equipment and cost issues; instead only scores are relied upon. Therefore this study sought to analyze the relation between the value of the density of FA actually delivered to RMC companies, attained with the Hydrometer method, and its fineness, to see whether the quality of FA can be evaluated statistically. Results led to the conclusion that there is a problem in terms of credibility in the fineness of FA shown on the test report. Upon analyzing the difference between the fineness of FA as measured using Blaine's air permeability method and its density of the Hydrometer method, the correlation was found to be satisfactory; therefore the possibility of a FA fineness quality evaluation could be proved as well.

  • PDF

Study on Substitution Effect caused by Application of BIM Simulation System to Mock-up Site (시공단계 현장 Mock-up의 BIM 기반 시뮬레이션 기법 적용에 의한 기대효과 분석 연구)

  • Jang, Se-Jun;Yun, Seok-Heon;Paek, Joon-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.147-151
    • /
    • 2008
  • Construction project is completed through several stages and problems of each stage affect directly not only now but also next. Defect of 2D drawings influence in construction phase, and it make many loss on project. Nowadays we practically use real Mock-up test in construction sites to solve the problems. But it also has many problems which are waste much money and time. Therefore, this study tries to analyze effect that is occurred by appling BIM Mock-up simulation instead of real Mock-up execution. These analysis is conducted by comparing two construction building site. These have same shape but one is made for BIM Mock-up, and another is real Mock-up. Comparison points of view are cost, time and operator's satisfaction. It is expect that BIM Mock-up is more effective at low cost and on shorter time. But our analysis show that each are conducted different part of function. So new Mock-up type is required. Hybrid Mock-up is combine real mock-up with BIM simulation and it can minimize risk of project.

  • PDF

Large Eddy Simulation of a High Reynolds Number Swirling Flow in a Conical Diffuser

  • Duprat, Cedric;Metais, Olivier;Laverne, Thomas
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.346-352
    • /
    • 2009
  • The objective of the present work is to improve numerical predictions of unsteady turbulent swirling flows in the draft tubes of hydraulic power plants. We present Large Eddy Simulation (LES) results on a simplified draft tube consisting of a straight conical diffuser. The basis of LES is to solve the large scales of motion, which contain most of the energy, while the small scales are modeled. LES strategy is here preferred to the average equations strategies (RANS models) because it resolves directly the most energetic part of the turbulent flow. LES is now recognized as a powerful tool to simulate real applications in several engineering fields which are more and more frequently found. However, the cost of large-eddy simulations of wall bounded flows is still expensive. Bypass methods are investigated to perform high-Reynolds-number LES at a reasonable cost. In this study, computations at a Reynolds number about 2 $10^5$ are presented. This study presents the result of a new near-wall model for turbulent boundary layer taking into account the streamwise pressure gradient (adverse or favorable). Validations are made based on simple channel flow, without any pressure gradient and on the data base ERCOFTAC. The experiments carried out by Clausen et al. [1] reproduce the essential features of the complex flow and are used to develop and test closure models for such flows.

Capital Structure Adjustment in Korean Retail Firms

  • Kim, Sang-Su;Lee, Jeong-Hwan
    • Journal of Distribution Science
    • /
    • v.15 no.11
    • /
    • pp.41-48
    • /
    • 2017
  • Purpose - Capital structure adjustment costs influence the test of the standard trade-off theory of capital structure. We investigate whether there exist economically significant capital adjustment costs in the Korean retail industry. Research design, data, and methodology - This paper adopts the model of Leary and Roberts(2005) to obtain the hazard rate of capital structure variations. The retail firms traded in the KOSPI and KOSDAQ markets are analyzed from 2000 to 2016. Results - The empirical analysis shows infrequent capital structure adjustments in the Korean retail firms. The duration analysis emphasizes that the fixed adjustment cost plays an important role in the determination of capital structure adjustments for the Korean retail firms. Yet, even after taking account of infrequent capital structure adjustments, the trade off theory only weakly explains the capital structure variations of the Korean retail firms. Conclusions - This paper confirms the existence of capital structure adjustment costs for the Korean retail firms. Our results argue for the significance of fixed adjustment costs in capital structure adjustments. Such emphasis on the fixed cost is inconsistent with the existing studies. The trade off theory does not successfully explain capital structure policy in the Korean retail firms even after considering adjustment costs.