• Title/Summary/Keyword: Test 1.1 & 2.1

Search Result 37,586, Processing Time 0.065 seconds

Effect of PVA Fiber and Silica Fume Addition on Chloride Penetration Resistance of Alkali-Activated Slag (PVA 섬유와 실리카흄 첨가가 알칼리 활성 슬래그의 염화물 침투 저항성에 미치는 영향)

  • Yoon, Hyun No
    • Journal of Urban Science
    • /
    • v.12 no.2
    • /
    • pp.13-18
    • /
    • 2023
  • This study investigates the effect of polyvinyl alcohol (PVA) fiber and silica fume addition on the chloride penetration resistance of alkali-activated slag. Silica fume was added to replace slag at the dosage of 0, 5, 10, and 20% by weight of the binder, while PVA fiber was added at the dosage of 0, 1, and 2% by volume of the mixture. Samples were synthesized via alkali activator with 1.0 of silicate modulus and cured at room temperature for 28 days. Compressive strength test, permeable voids volume test, water absorprtion test, and rapid chloride penetration test were conducted for measuring the charaterisitics of alkali-activaed slag. The results showed that increasing silica fume content up to 10% in alkali-activated slag improved compressive strength and chloride penetration resistance. Addition of PVA fibers up to 1% by volume enhanced strength and chloride penetration resistance, but exceeding this led to reduced strength and durability due to increased void formation in the matrix.

Analysis of Bearing Capacity and Safety Factor of Dynamic Load Test of Prebored and Precast Steel Pile (현장재하시험을 통한 강관 매입말뚝의 지지력 안전율 제안)

  • Park, Jong-Jeon;Jeong, Sang-Seom;Park, Jeong-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.5
    • /
    • pp.5-17
    • /
    • 2018
  • In this study, the static and dynamic load tests were carried out to propose the safety factor of steel prebored and precast piles in weathered rocks. The axial load tests have been conducted on test piles with nominal diameters of 0.508 and 0.457 m. The piles were subject to static loading tests (14 times) and dynamic loading tests (EOID 14times, Restrike 14times). The dynamic loading tests were first executed after the casting of test piles ((1) initial EOID test). (2)In the succeding 28 days from completion of construction, static load tests were performed and (3)final restrike tests were carried out after 15 days from the static test. As a result, the bearing capacity based on Davisson method was 15% higher than that of the restrike tests. The bearing capacity of the static load tests were larger than that of the dynamic tests. By comparing the safety factor through various loading tests, the safety factor of dynamic loading tests were suggested to be lowered to 1.75 from the conventional 2.0.

Effects of Titratable Acidity and Organic Acids on Enamel Erosion In Vitro

  • Kim, Eun-Jeong;Jin, Bo-Hyoung
    • Journal of dental hygiene science
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Background: Erosion is a gradual process that occurs fairly quickly, and the full extent of the erosive effects of acidic beverages is not yet clear. The present study aimed to determine the differences in the erosive potentials among four naturally acidic fruit nectars within the same range of titratable acidity and to determine the influence of the components of organic acids on tooth erosion. Methods: Diluted fruit nectars (mandarin 1:1.1, orange 1:1.7, lemon 1:15, grapefruit 1:20) with the same range of titratable acidity (7.9 ml) and their corresponding organic acids (0.05%, 0.1%, 0.3%, and 0.5% citric acid, malic acid, and a citric and malic acid mixture [pH 2.8], respectively) were used. Specimens were placed in conical tubes with 50 ml of each of the test solutions for 1 hour. A microhardness test and scanning electron microscopy were used to measure enamel erosion. Acid separation was carried out using high-performance liquid chromatography to analyze the composition of each test solution. Results: Similar decreases in the Vickers hardness number (VHN) were observed among the groups treated with the following diluted fruit nectars: diluted mandarin nectar ($75.9{\Delta}VHN$), diluted lemon nectar ($89.1{\Delta}VHN$), diluted grapefruit nectar ($91.7{\Delta}VHN$), and diluted orange nectar ($92.5{\Delta}VHN$). No statistically significant differences were found in the enamel surface hardness after erosion (p>0.05). Citric and malic acids were the major organic acids in the test fruits. The lemon and orange groups had the highest malic acid concentrations, and the mandarin group had the lowest malic acid concentration. Conclusion: The titratable acidity and the citric and malic acid contents of the fruits could be crucial factors responsible for enamel erosion. Therefore, fruit-based drinks should be regarded as potentially erosive.

Testing the Consistency of Unified Scheme of Seyfert Galaxies

  • Iyida, Evaristus U.;Eya, Innocent O.;Eze, Christian I.
    • Journal of Astronomy and Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.43-50
    • /
    • 2022
  • The unified scheme of Seyfert galaxies hypothesizes that the observed differences between the two categories of Seyfert galaxies, type 1 (Sy1) and type 2 (Sy2) are merely due to the difference in the orientation of the toroidal shape of the obscuring material in the active galactic nuclei. We used in this paper, a sample consisting of 120 Seyfert galaxies at 1.40 × 109 Hz in radio, 2.52 × 1017 Hz in X-ray and 2.52 × 1023 Hz in γ-ray luminosities observed by the Fermi Large Area Telescope (Fermi-LAT) in order to test the unified scheme of radio-quiet Seyfert galaxies. Our main results are as follows: (i) We found that the distributions of multiwave luminosities (Lradio, LX-ray, and Lγ-ray) of Sy1 and Sy2 are completely overlapped with up to a factor of 4. The principal component analysis result reveals that Sy1 and Sy2 also occupy the same parameter spaces, which agrees with the notion that Sy1 and Sy2 are the same class objects. A Kolmogorov-Smirnov test performed on the sub-samples indicates that the null hypothesis (both are from the same population) cannot be rejected with chance probability p ~ 0 and separation distance K = 0.013. This result supports the fact that there is no statistical difference between the properties of Sy1 and Sy2 (ii) We found that the coefficient of the best-fit linear regression equation between the common properties of Sy1 and Sy2 is significant (r > 0.50) which plausibly implies that Sy1 and Sy2 are the same type of objects observed at different viewing angle.

Air-tightness Evaluation of Tube Structures for Super-speed Tube Railway Systems: II. System Test and Parametric Analysis (초고속 열차 시스템을 위한 튜브 구조물의 기밀성 평가 : II. 시스템 실험 및 파라메터 해석)

  • Park, Joo-Nam;Kim, Lee-Hyeon;Nam, Seong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.2
    • /
    • pp.151-159
    • /
    • 2011
  • This study performed an experimental study for air-tightness performance evaluation of concrete tube structures with joints. The test specimens consist of a continuous concrete tube, a concrete tube with a joint in the middle, and a segmented concrete tube. The test is performed in such a way that the inner pressure of the tube is dropped down to 0.1atm and the increase of the pressure is monitored with time. An equivalent air permeability is then calculated based on the test results. The results show that, as expected, a structure with more joints or bonds tends to be less air-tight. A sensitivity study shows that the system air-tightness performance level becomes higher as either the diameter or the thickness of the tube increases. Moreover, the increase in the diameter or the thickness of the tube makes an effort to enhance the air-tightness more effective.

Aerodynamic Characteristics of the Original Airfoil KA2 for the Application of Wind Turbine Blade (풍력 블레이드 적용을 위한 고유익형 KA2의 공력특성)

  • Woo, Young-Jin;Kang, Deok-Hun;Lee, Jang-Ho
    • Journal of Wind Energy
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • The new aerofoil, KA2 was designed to apply to the wind turbine blade. For the aerofoil, numerical analysis was performed to review aerodynamic characteristics like lift and drag coefficient. And they are verified with test data using the digital wind tunnel and test samples from 3D printer. The digital wind tunnel was developed to test wing in the small laboratory, and verified with test of NACA0012 airfoil. KA2 aerofoil is asymmetric, and has the thickness ratio of 14%, and 12 degree of AOA at the maximum lift coefficient of 1.3. In this paper, aerodynamic characteristics from numerical and test approaches will be proposed with AOA in detail. Therefore, this aerofoil will be used for the design of wind turbine blade.

Use of the enzyme-linked immunosorbent assay for the detection of toxoplasmosis in swine (ELISA를 이용한 돼지 톡소플라스마병의 조기 진단에 관한 연구)

  • Suh, Myung-deuk;Jang, Dong-hwa;Joo, Hoo-don
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.4
    • /
    • pp.567-575
    • /
    • 1989
  • This study was conducted to evaluate the possibility of application of a microenzyme-linked immunosorbent assay(micro-ELISA) for the serodiagnosis of specific toxoplasma antibodies in swine sera and this test was performed as a microplate system by coating the polystyrene plates with toxoplasma soluble antigen, incubated serially diluted sera, then added horse radish peroxidase labelled goat anti-swine IgG(r) conjugate followed by o-phenylenediamine as substrate. The color development by enzyme-substrate reaction was determined by the photometric reading [ELISA reader at 490nm (OD)] and visual reading. The soluble antigen was prepared from the tachyzoites in mouse peritoneal cavity. A total of 1,200 swine sera from pig slaughter-house and a total of 116 swine sera from pig breeding station (S-C farm) were tested for the detection of antibodies to Toxoplasma gondii. The results obtained were summarized as follows: 1. The optimal reactions of indirect ELISA for the test sera were determined by the dilution of antigen 1:256 and 1:3,200 of horse radish peroxidase conjugate [anti-swine IgG(r)]. 2. The specific togoplasma antibody(IgG) in pigs infected with Tp artificially were detected as the serum titers of 1:64 or 1:128 at one week postinfection. 3. Of a total of 1,200 swine sera from pig slaughter-house 505 samples of sera were detected as positive (42.1%) and of a total of 116 swine sera from S-C pig breeding station 68 samples of sera as positive (58.6%). 4. The specific antibody(IgG) detection rates against a total of 1,200 test sera from pig slaughter-house were not significant between male (43.1%) and female (40.7%). 5. The indirect ELISA was proved to be a sensitive and specific procedure for the serodiagnosis of swine toxoplasmosis and also evaluated as an effective screening test for the large scale of test samples in laboratory.

  • PDF

The Study of Distance and Near AC/A Ratio by Stimulus (조절자극 방식에 따른 원거리와 근거리 AC/A비에 관한 연구)

  • Jo, Tae-Sik;Kim, In-Suk;Jang, Jung-Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Purpose: This study was to investigate that near gradient AC/A ratio could be used to prescribe a patient with distance exophoria, we compared the difference between distance gradient AC/A ratio and near gradient AC/A ratio. Also, this thesis was to understand the relationship between calculated AC/A ratio and gradient AC/A ratio. Methods: Objective and subjective refractive error were corrected and we used Howell (3 m) chart for distance phoria tests and Howell-Kim (40 cm) chart for near phoria tests. The near gradient AC/A ratio and calculated AC/A ratio were used by Howell-Kim (40 cm) combined with +1.00 D, -1.00 D, +2.00 D and -2.00 D. Results: The average value of distance exophoria was 1.17${\pm}$1.17 $\Delta$, and the average value of near exophoria was 3.71${\pm}$2.80 $\Delta$ (t-test. p<0.001). The correlation of distance phoria with near phoria was little higher (r = 0.59, p < 0.001). Gradient AC/A ratios depending on measuring distance and stimulus were higher (r = 0.11~0.53. P < 0.001), when distance was shorter and stimulus to accommodation was more. Also, stimulus to accommodation by plus lens was higher than stimulus to accommodation by minus lens (paired t-test. p < 0.001). There was negative correlation between calculated AC/A ratio and gradient AC/A ratio. As the calculated AC/A ratio was higher, gradient AC/A ratio was lesser. Near gradient AC/A ratio was slightly higher than distance gradient AC/A ratio. Distance and near gradient AC/A ratio taken through the subjective -1.00 D were 1.30 $\Delta$/D and 1.68 $\Delta$/D(t-test. t=1.67, p < 0.001). Conclusions: There is negative correlation between calculated AC/A ratio and gradient AC/A ratio. Also, there is subtle difference between near gradient AC/A ratio and distance gradient AC/A ratio. Therefore, we need to measure distance gradient AC/A ratio when a practitioner prescribe glasses for a patient with distance exophoria.

An Experimental Study on Production of Egg Yolk Antibody(IgY) against Bee Venom (봉독의 항독소(IgY)생산을 위한 실험적 연구)

  • Hwang, Tae-Jun;Lee, Seung-Bae;Gwon, Gi-Rok
    • Journal of Pharmacopuncture
    • /
    • v.4 no.2
    • /
    • pp.5-15
    • /
    • 2001
  • This study was carried out for production of neutral antibody to bee venom $(anti-phospholipase\;A_2IgY)$. Hen layings were injected repeatedly with bee venom and phospholipase $A_2$ with Freund's adjuvant. Specific antibody in egg yolk from immunized hen laying was separated, and purified, also immunological characteristics of anti phospholipase $A_2\;IgY$ was invested. The results were summarized as follows: 1. Phospholipase $A_2$ was showed single band at molecular weight 17,000 in SDS-PAGE and bee venom was showed two band at molecular weight 17,000 and under molecular weight 6,500 in SDS-PAGE. 2. During 70 days after hen immunized with bee venom and phospholipase $A_2$, antibodies(anti-bee venom IgY) to bee venom were showed poor ELISA value in egg yolk, but antibodies$(anti-Phospholipase\;A_2IgY)$ to phospholipase $A_2$ in egg yolk were increased ELISA value from 8 days or 15 days and found maximum ELISA value at 42 days. Also after booster at 49 days, ELISA value of anti Phospholipase $A_2\;IgY$ in egg yolk was supported at optical density(O.D) 1.0 level, continuously. 3. Titer of phospholipase $A_2\;IgY$ was showed 1: 32,000. 4. In double immunodiffusion test to phospholipase $A_2$ after double dilution of anti-phospholipase $A_2\;IgY$, only precipitation line was made in 1:1 dilution well of anti-Phospholipase $A_2\;IgY$. But In immunodiffusion test to anti-phospholipase $A_2\;IgY$ after double dilution of phospholipase $A_2$, Precipitation line to 250ul/ml well of phospholipase $A_2$ was showed. In double immunodiffusion test to bee venom(1mg/ml) after double dilution anti-phospholipase $A_2\;IgY$, all well without 1:32 dilution well were showed strong precipitation line. 5. In dot bloting test to anti-phospholipase $A_2\;IgY$ after diluting bee venom(0.5mg/ml), dot bloting color was showed clearly to $1/100(5{\mu}g/ml)$ in bee venom.

Fit analysis of CAD-CAM custom abutment using micro-CT (Micro-CT를 이용한 맞춤형 CAD-CAM 지대주의 적합성 분석)

  • Min, Gwang-Seok;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.370-378
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate screw joint stability and sagittal fit between internal connection implant fixtures of two different manufacturers and customized abutments. Materials and methods: Internal connection implant systems from two different manufacturers (Biomet 3i system, Astra Tech system) were selected for this study (n=24 for each implant system, total n=48). For 3i implant system, half of the implants were connected with Ti ready-made abutments and the other half implants were connected with Ti CAD-CAM custom ones of domestic-make (Myplant, Raphabio Co., Seoul, Korea) and were classified into Group 1 and Group 2 respectively. Astra implants were divided into Group 3 and Group 4 in the same way. Micro-CT sagittal imaging was performed for fit analysis of interfaces and preloading reverse torque values (RTV) were measured. Results: In the contact length of fixture-abutment interface, there were no significant differences not only between Group 1 and Group 2 but also between Group 3 and Group 4 (Mann-Whitney test, P>.05). However, Group 2 and Group 4 showed higher contact length significantly than Group 1 and Group 3 in abutment-screw interface as well as fixture-screw one (Mann-Whitney test, P<.05). In addition, RTV was lower in CAD-CAM custom abutments compared to ready-made ones (Student t-test, P<.05). Conclusion: It is considered that domestically manufactured CAD-CAM custom abutments have similar fit at the fixture abutment interface and it could be used clinically. However, RTV of CAD-CAM custom abutments should be improved for the increase of clinical application.