• Title/Summary/Keyword: Test 1.1 & 2.1

Search Result 37,430, Processing Time 0.085 seconds

Clinical Analysis of Influenza in Children and Rapid Antigen Detection Test on First Half of the Year 2004 in Busan (2004 상반기 부산 지역에서 유행한 인플루엔자의 임상 역학적 분석 및 인플루엔자 진단에 있어서의 신속 항원 검사법)

  • Choi, So Young;Lee, Na Young;Kim, Sung Mi;Kim, Gil Heun;Jung, Jin Hwa;Choi, Im Jung;Cho, Kyung Soon
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.2
    • /
    • pp.158-169
    • /
    • 2004
  • Purpose : Although influenza is one of the most important cause of acute respiratory tract infections in children, virus isolation is not popular and there are only a few clinical studies on influenza and diagnostic methods. We evaluated the epidemiological and clinical features of influenza in children and rapid antigen detection test(QuickVue influenza test) on fist half of the year 2004 in Busan. Methods : From January 2004 to June 2004, throat swab and nasal secretion were obtained and cultured for the isolation of influenza virus and tested by rapid antigen detection test(QuickVue influenza test) in children with suspected influenza infections. The medical records of patients with influenza virus infection were reviewed retrospectively. Results : Influenza viruses were isolated in 79(17.2%) out of 621 patients examined. Influenza virus was isolated mainly from March to April 2004. The ratio of male and female with influenza virus infection was 1.2 : 1 with median age of 4 years 6month. The most common clinical diagnosis of influenza virus infection was bronchitis. There was no difference between influenza A and B infection in clinical diagnosis and symptoms. All patients recovered without severe complication. The sensitivity obtained for rapid antigen detection test (QuickVue influenza test) was 93.6% and the specificity was 80.2%, the positive predictive value 40.8%, the negative predictive value 98.8%. Conclusion : With rapid antigen detection test, it is possible early detection of influenza in children. reduction in use of antimicrobial agent and early use of antiviral agent.

  • PDF

Axial Compressive Strength of Rectangular Hollow Section Members (각형 강관의 축방향 압축강도에 관한 연구)

  • Jo, Jae Byung;Lim, Jeong Soon;Han, Choong Seong
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.153-160
    • /
    • 1998
  • The sectional dimensions and initial crookedness of the RHS(rectangular hollow section, ${\boxe}-75{\times}75{\times}3.2,\;{\boxe}-100{\times}100{\times}4.2,\;{\boxe}-125{\times}125{\times}6.0$) were measured. The axial compressive strength tests for columns with slenderness $46{\sim}84$ were performed as well as stub tests and tensile tests. FEM analysis was also used. The measurement shows that the errors of sectional dimensions are negligible. For the column length corresponding to ${\lambda}=100$, the initial crookedness with the 2.5% probability estimated from the measured results is 1/490, 1/1121 1/1395 for each section respectively. The yield strengths obtained from tensile test are higher than the specified minimum value by more than 30%. The column test shows that the maximum axial resistances are almost same as, or a little higher than the FEM results and the specified strength curves of AISC Specification and Eurocode, when the maximum strengths from the stub tests are used as the yield strength of the steel. But the test results show much higher column strength than those specified in the Standard and Code, when the specified minimum yield strength of the steel is used.

  • PDF

GENERALIZED MINIMUM $x^2$ TEST FOR THE EXTREME VALUES

  • Lee, Chun-Jin
    • Journal of applied mathematics & informatics
    • /
    • v.1 no.1
    • /
    • pp.43-48
    • /
    • 1994
  • There are some difficulties in applying the Pearson's Chi-Square Test for the continuous distribution. The problems include how to form class intervals for the test of fit how to employ in the test when the estimators of parameters are obtained from the ungrouped sample so on. In order to solve these problems we use the generalized minimum Chi-Square technique which is a test free of the complications associated with the Peason's Chi-Square test. This paper show how to apply the goodness of fit tests based on generalized minimum Chi-Square technique to the extreme values.

Pressure Characteristics on Korean High-Speed Railway Acoustic Screen Using 1/61 Scaled-Down Moving Model Rig

  • Jang, Yong-Jun;Kim, Hag-Beom;Jung, Woo-Sung;Kim, Dong-Hyeon
    • International Journal of Railway
    • /
    • v.2 no.2
    • /
    • pp.93-97
    • /
    • 2009
  • The experiments for aerodynamic characteristics of railway acoustic screen are performed using 1/61 scaled-down moving model rig facility which employs an axis symmetry and one wire guidance method. The launching mechanism is an air-gun type. The train model for the experiment is the high speed train (Korea Train Express: KTX) and the tested speed is about 300 km/h. The tested train length is 61 em which is corresponding to two units of KTX train. The cross sectional area and weight of train model are 0.00264 $m^2$ and 287 g, respectively. The Reynolds number based on the model train length is $1.2{\times}10^7$. The strength of pressure wave is measured using piezo typed pressure sensor. The measured pick value of pressure was as high as 365 Pa in the shortest gap between the acoustic screen and model train. The measured pressure is well compared with the field test data of mc 779-1 [2] values. However, the experimental data were slightly lower than the mc 779-1 values. The results show the model test can be used as a substitute for the field test.

  • PDF

Study on Large Diameter Steel-cased Piles Socketed in Weathered and Fresh Rocks (풍화암과 연암에 근입된 대구경 말뚝의 축하중지지 거동에 관한 연구)

  • Nam Moon-Seok;Lee Min-Hee;Choi Yong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.3
    • /
    • pp.5-11
    • /
    • 2006
  • Two large diameter steel cased piles (TS-1 and TS-2) were installed and load-tested with the maximum load of 2000 ton at Kwang-An grand bridge. One of the test piles (TS-1) was socketed into the fresh rock and the other test pile (TS-2) was socketed into the weathered rock. Most loads were carried by the weathered rock layer at the maximum applied load for the test piles. In addition, numerical studies were performed using PENTAGON 3D and ROCKET. Based on this study, the weathered rock layer provided sufficient side resistances and possibility of an alternative embedded layer if weathered rocks are deeply layered over fresh rock, which caused difficulties and cost in construction.

Clinical Results of Anatomical Single Bundle Anterior Cruciate Ligament Reconstruction Using Autogenous Quadriceps Tendon (자가 대퇴사두건을 이용한 해부학적 단일 다발 전방십자인대 재건술의 임상적 결과)

  • Park, Jin;Kim, Young Sin;Lee, Ju Hong;Wang, Seong Il;Park, Chan Ill
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the clinical outcomes and stability of anatomical single bundle anterior cruciate ligament reconstruction (SBACLR) with quadriceps tendon comparable to double bundle anterior cruciate ligament reconstruction (DBACLR). Materials and Methods: We retrospectively reviewed 28 consecutive patients (16 male, 12 female) who underwent SBACLR using quadriceps tendon from March 2009 (Group 1) and compared its clinical results to whom DBACLR with semitendinosus tendon for 53 patients (51 male, 2 female) from August. 2006 (Group 2). Mean age were 34.9 (range, 16-52) in Group 1 and 21.6 (range, 17-55) in Group 2. Mean follow up periods were 13.9 months (range, 12-20) in Group 1 and 36.2 months (range, 20-52) in Group 2. Lysholm score, International Knee Documentation Committee (IKDC) evaluation form and Tegner score were performed for evaluating the clinical outcome. Lachman test, pivot shift test and KT-1000 arthrometer (MEDmetric Corp., San Diego, CA, USA) were performed for stability. Results: There was no statistical significant difference between the two groups in terms of Lysholm score (Group 1: $85.9{\pm}2.6$, Group 2: $90.9{\pm}1.0$, P=0.226), IKDC score (P=0.345) and Tegner score (Group 1: $6.9{\pm}1.4$, Group 2: $7.1{\pm}1.3$, P=0.523). Nor was there statistical significance between the two groups in terms of KT-1000 arthrometer (Group 1: $1.5{\pm}1.1\;mm$, Group 2: $1.5{\pm}1.6\;mm$, P=0.457), Lachman test (P=0.547) and pivot shift test (P=0.073). Conclusion: Anatomical SBACLR with quadriceps tendon shows similar clinical outcomes and stability comparable to anatomical DBACLR with hamstring tendon.

  • PDF

Viability Assessment of Fresh and Frozen-thawed Dog Spermatozoa by Flow Cytometry (Flow Cytometry에 의한 개 신선정액과 동결정액의 생존성 분석)

  • Hong Y. M.;Kim Y. J.;Yu I.;Ji D. B.;Kim M. S.
    • Reproductive and Developmental Biology
    • /
    • v.28 no.3
    • /
    • pp.167-172
    • /
    • 2004
  • This study was performed to examine the correlations among dog sperm viabilities evaluated by flow cytometry, by microscopic evaluation (ME), by carbo-xifluorescein diacetate and propidium iodide (CFDA/PI) and by hypoosmotic swelling (HOS) test. Semen were collected from 5 dogs ranging in age from 2 to 4 years. Each ejaculate was divided into 3 aliquots and different proportions of freeze-killed cells were added to each aliquot (1:0, 1:1 and 1:3). In the other experiment, semen was extended with Sweden extender containing 5% glycerol and equex STM paste, and frozen using liquid nitrogen vapor. Fresh and frozen-thawed dog sperm viability were assessed by flow cytometry using PI staining method. The accuracy of flow cytometry was evaluated by comparing with other classic assessments, microscopic evaluation, epifluorescence microscopic analysis using CFDA/PI, and HOS test. High correlations of sperm viabilities were found among flow cytometry, epifluorescence evaluation, HOS test (p<0.01) in fresh semen. Especially, sperm viability assessed by HOS test was highly correlated with viability by flow cytometry in all the ratios of live and dead spermatozoa, 1:0, 1:1 and 1:3 (p<0.01). The viability evaluated by ME were significantly correlated with that by flow cytometry in ratios of 1:0 and 1:3 (p<0.05) however, there was no significance in ratio of 1:1. The viability evaluated by C/p were highly correlated with that by flow cytometry in ratio of 1:0 and 1:1 (p<0.01) and significantly correlated in ratio of 1:3 (p<0.05). In frozen-thawed spermatozoa, the viability determined by HOS test was considerably correlated with that by flow cytometry (p<0.01). There was significant correlation between the viabilities by ME and by flow cytometry (p<0.05). But the viability evaluated by CFDA/PI was not correlated with viability by flow cytometry. The result from this study validate the use of flow cytometry as a precise method for assessing the viability of fresh and frozen-thawed dog spermatozoa.

Thermo-Mechanical Fatigue Analysis of Ribbon Wire/Ag Electrode Interfaces for PV Module

  • Park, No-Chang;Hong, Won-Sik;Han, Chang-Un;Kim, Dong-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.48.1-48.1
    • /
    • 2011
  • In this presentation, We monitored weather data, such as global irradiance, ambient temperature, temperature of PV module, relative humidity and windspeed for 2 years, for determining accelerated test condition. then, we determined the temperature limit of accelerated test through weather data and FEM analysis. Detailed procedures will be summarized in this work. After analysing outdoor stress such as thermal stress, we decided main failure modes and mechanisms of PV module, especially solder joint of ribbon wire. we carried out the measurement of material properties such as thermal expansion coefficient for planning of accelerated test. we designed accelerated test based on FEM analysis results. we carried out thermal cycling test with 1 cell mini module for 3 months. We monitored the change of electrical performance every 1 week such as Voc, Isc, Pmax, etc. and then, we analized the ribbon wire/electrode intefaces. Detailed results will be summarized in this work.

  • PDF

Application of Water Treatment with Membrane in Seomjin River (섬진강 수계에서 막여과 정수처리 공정 적용성 평가)

  • Kim, Jongdoo;Park, Kyungwook;Park, Chulhwi
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.12-23
    • /
    • 2013
  • On the subject of river bed water in Seomjin river, it had accomplished the verifying experiment of membrane filtration pilot plant for evaluating the applicability of its process throughout the prediction of membrane fouling as a function of the pore size of membrane and the determination of optimum coagulant dosage. On the result of the experiment for the evaluation of the membrane fouling as a function of the pore size, a increasing rate of irreversible resistance of membrane pore size $0.1{\mu}m$ and $0.01{\mu}m$ was measured each $0.44{\times}10^{12}/m^2$ and $0.42{\times}10^{12}/m^2$, respectively. And on the result of Flux-test, it showed that the optimum coagulant dosage was measured lower than the it of the Jar-test. The result to be operated in a condition of a permeate flux $1.0{\sim}1.5m^3/m^2{\cdot}day$ without coagulation and a permeate flux $1.0{\sim}2.0m^3/m^2{\cdot}day$ with coagulation was maintained at stable trans-membrane pressure (TMP) value for 6 months up to. Therefore it showed that the stable operation without the coagulation was possible on permeate flux $1.0{\sim}1.5m^3/m^2{\cdot}day$ in the operation of membrane filtration process.

Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods (서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성)

  • Cho, Young Beom;Chae, Heon Chung;Kim, Hee Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.366-376
    • /
    • 2013
  • The purpose of this study is to evaluate the marginal and internal fit of coping made by CAD/CAM using different scanning methods. Zirconia coping was made by each CAD/CAM system followed by intra-oral scanning, model optical scanning and model contact scanning. It was embedded into Epoxy Resin and was cut by buccal to lingual. AMD (Absolute marginal discrepancy), MG (Marginal gap), GA (Gap of axial), GL (Gap of line angle) and GO (Gap of occlusal) of each sample were measured. The result is as followed; 1. The mean value of AMD in Group 1, Group 2, Group 3 are $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$. The averages of MG in Group 1, Group 2, Group 3 are $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$. Statistically there is no difference in AMD and MG among the three Groups (Anova, P>0.05). 2. GA of Group 2 revealed statistically difference compared with Group 1 and Group 3 (Anova, P<0.05). 3. GL and GO of Group 1 showed statistically significant differences compared with Group 2 and Group 3 (Mann-whitney test (P<0.05). Zirconia copings made by 3 ways of scanning methods have no difference with conventional ceramics in AMD and MG which are known as the most important factors.