• Title/Summary/Keyword: Test 1.1 & 2.1

Search Result 37,430, Processing Time 0.07 seconds

Study on Friction Welding of SUS431 and SCM21 for External Shaft of Ship (선외기 샤프트용 재료의 마찰용접에 관한 연구)

  • 오세규;이종환;배명주;오명석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.38-48
    • /
    • 1993
  • A study on friction welding of stainless steel bar(SUS431) to chrome molybdenum steel bar(SCM21) was accomplished experimentally through analysis for relations among friction welding conditions, tension test, hardness test, microstructure test and acoustic emission test. The results obtained are summarized as follows ; 1. Through friction welding of SUS431 bar to SCM21 bar, the optimum welding condition by considering on strength and toughness was found to be the range of heating time of 3-5 sec when the number of rotating speed of 2000rpm, heating pressure of 10kg/$mm^2$, and upsetting time of 4 sec. 2. Quantitative ralationship was identified between heating time($T_1$, sec) and tensile strength (${\sigma},\;kgf/mm^2$) of the friction welded joint and the relation equation is $\sigma$=52.62$T_1{^{0.06}}$. 3. Through AE test, quantitative relationship was confirmed between heating time($T_1$, sec) and total AE(N, counts) during welding, and the relation is computed as follows ; N=30413.6$e^{0.06T1}$. 4. It was confirmed that the quantitative ralationship exists between the tensile strength of the welded joints and AE cumulative counts. And the relation is computed as the following ; ${\sigma}$=16.37(ln N)- 116.4. 5. When ONZ=36500-41500 counts by $OT_1Z$=3~5sec, it was identified by experiment that the range of welded joint tensile strength is 55.6-57.7kgf/$mm^2$/ whose joint efficiency is more than 100%, and it was experimentally confirmed that the real-time nondestructive quality(strength) evaluation for the friction welded joints could be possible by acoustic emission technique.

  • PDF

Bioequivalence of Ramiprin® tablet to Tritace Protect® tablet (Ramipril 10 mg) (트리테이스프로텍트 ®정(라미프릴 10mg)에 대한 라미프린 ®정의 생물학적동등성)

  • Oh, Soo-Yeon;Cho, Jong-Tae;Kim, Hyung-Gun;Kim, Yoon-Gyoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.73-78
    • /
    • 2008
  • To evaluate the bioequivalence of two ramipril formulations, a standard 2-way randomized cross-over study was conducted in twenty-six healthy male Korean volunteers. A single oral dose of 10 mg of test formulation $Ramiprin^{(R)}$ (tablet) or reference formulation Tritace $Protect^{(R)}$ (tablet) was administered with one-week washout period. Plasma concentrations of ramipril were assayed over a period of 12 hr with a well validated method using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The values of area under the plasma concentration-time curve, from time zero to last sampling time $(AUC_t)$ and from time zero to time infinity $(AUC_{inf})$ were $77.45{\pm}44.78\;and\;78.96{\pm}45.64$ for test, and $70.30{\pm}42.27\;and\;71.99{\pm}43.55ng\;hr/mL$ for reference formulation, respectively. Similarly, maximum concentration $(C_{max})$ and elimination half-life $(t_{1/2})$ were $65.61{\pm}19.96ng/mL$ and $2.15{\pm}0.75hr$ for test, and $63.63{\pm}25.50ng/mL$ and $2.16{\pm}0.73hr$ for reference formulations, respectively. Time to reach maximum concentration $(T_{max})$ for the test and the reference, were $0.51{\pm}0.22hr\;and\;0.52{\pm}0.18hr$, respectively. The parametric 90% confidence intervals on the mean of the differences between the two formulations (test-reference) of the log-transformed values of $AUC_t\;and\;C_{max}$ were 1.03 to 1.19 and 0.98 to 1.17, respectively. The overall results indicate that the two formulations are bioequivalent and can be prescribed interchangeably.

The Associated Factors with Utilization of Tests for Diabetes Complication and Hemoglobin A1c among Some Diabetes Patients (당뇨병 환자의 합병증검사 및 당화혈색소검사 수진 관련 요인)

  • Son, Young Eun;Ryu, So Yeon;Park, Jong;Han, Mi Ah;Gu, Hyae Min
    • Health Policy and Management
    • /
    • v.26 no.3
    • /
    • pp.207-218
    • /
    • 2016
  • Background: This study was performed to identify factors associated with the utilization of tests for diabetes complication and hemoglobin A1c (HbA1c) among diabetes patients in Jeollanam-do, Korea. Methods: The study subjects were 2,310 diabetes patients participated in 2014 community health survey in Jeollanam-do, Korea. Dependent variables were the utilizations of fundus examination, microalbuminuria test, and HbA1c test. The used statistical analysis methods were chi-square test and hierarchical regression analysis with weight in consideration of complex sample design. Results: The utilization rates of fundus examination, microalbuminuria test, and HbA1c test were 25.8%, 27.4%, and 12.3%, respectively. In the results of hierarchical regression, fundus examination was significantly related to age, education level in predisposing factors, residential area in enabling factors and recognition of blood sugar, drug therapy, and subjective health status in need factors. Microalbuminuria examination was significantly related to monthly income, residential area in predisposing and health screening, recognition of blood sugar, drug therapy, diabetic education, number of chronic disease, and subjective health status in need factors. HbA1c examination was significantly related to age, education level, marital status in predisposing factors, residential area in enabling factors and drinking, recognition of blood sugar, drug therapy, and diabetic education in need factors. Conclusion: The results of this study were shown that perception of their disease seriousness, education about diabetes management, and accessibility of tests were important to utilization of test for diabetes complication and HbA1c. It might be necessary to the develop and strength strategies for enhancing the utilization of tests for diabetes complication and management in diabetes patients.

Numerical simulation of tensile failure of concrete using Particle Flow Code (PFC)

  • Haeri, Hadi;Sarfarazi, Vahab
    • Computers and Concrete
    • /
    • v.18 no.1
    • /
    • pp.39-51
    • /
    • 2016
  • This paper considers the tensile strength of concrete samples in direct, CTT, modified tension, splitting and ring tests using both of the experimental tests and numerical simulation (particle flow code 2D). It determined that which one of indirect tensile strength is close to direct tensile strength. Initially calibration of PFC was undertaken with respect to the data obtained from Brazilian laboratory tests to ensure the conformity of the simulated numerical models response. Furthermore, validation of the simulated models in four introduced tests was also cross checked with the results from experimental tests. By using numerical testing, the failure process was visually observed and failure patterns were watched to be reasonable in accordance with experimental results. Discrete element simulations demonstrated that the macro fractures in models are caused by microscopic tensile breakages on large numbers of bonded discs. Tensile strength of concrete in direct test was less than other tests results. Tensile strength resulted from modified tension test was close to direct test results. So modified tension test can be a proper test for determination of tensile strength of concrete in absence of direct test. Other advantages shown by modified tension tests are: (1) sample preparation is easy and (2) the use of a simple conventional compression press controlled by displacement compared with complicate device in other tests.

Analysis of Bank Efficiency Between Conventional Banks and Regional Development Banks in Indonesia

  • ABIDIN, Zaenal;PRABANTARIKSO, R.Mahelan;WARDHANI, Rhisya Ayu;ENDRI, Endri
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.1
    • /
    • pp.741-750
    • /
    • 2021
  • The research aims to analyze the level of efficiency by grouping banks during the period 2017 - 2018 into category 1 and category 2 banks and then dividing them as Regional Development Banks (BPD) and Non-BPD Conventional Commercial Banks (BUK) within each category. The research objects are banks within the categories BPD and BUK comprised 18 BPDs and 35 BUKs. The research methodology uses 3 stages, first, using Data Envelopment Analysis (DEA) we measure the level of bank efficiency; second, using the Tobit regression model we evaluate the effect of financial performance on DEA efficiency, and third, using the Mann-Whitney test we determine whether there is a difference in the efficiency of category 1 and 2 banks. The results showed that there was a decrease in the efficiency of category 1 and 2 banks but on average, the efficiency of category 1 banks is higher than category 2 banks. The estimation results of the Tobit regression model show that only the ROA variable affects the efficiency level of category 1 banks, while category 2 banks are influenced by NPL and ROA variables. In the Mann-Whitney test, it was proven that there were differences in efficiency between BUK and BPD in category 1 and 2 banks.

A Development of the Test Set for Estimating the Retrieval Performance of an Automatic Indexer (자동색인기 성능시험을 위한 Test Set 개발)

  • 김성혁;서은경;이원규;김명철;김영환;김재군
    • Journal of the Korean Society for information Management
    • /
    • v.11 no.1
    • /
    • pp.81-102
    • /
    • 1994
  • Accordmg to the development of various information retneval system suitable for Korean database, many researchers have realized the need of R Test ColleAon which can be r d y used for evaluatmg a retneval system. Therefore, This study developed the TEST SET whch helps ob&vely evaluatmg the retrieval performance of an Hangul Automatic Indexer or Korean Information Retrieval System. The developed Test Set has four files such as: 1) Korean Document Set( * . all): 2) Natural Language Query Set(KTsetnq1): 3) Boolean Query Set(Ktset.bq1): 4) Query-Relevance Judgment Set ( KTsetrel) .

  • PDF

Proposal of a Simulated Test Method for the Evaluation of Deformation and Failure Characteristics of Pipe Elbows under Cyclic Loads (반복하중 하의 엘보우 변형 및 손상 특성 평가를 위한 모사시험 방법 제안)

  • Kim, Jin Weon;Lee, Dae Young;Park, Heung Bae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • This study proposed a simulated test method using ring specimen to evaluate the deformation and failure characteristics of pipe elbows under a large amplitude cyclic load. The validity of the test method was demonstrated by finite element (FE) analysis of pipe elbow and ring specimen under cyclic loads. The results showed that the proposed test method adequately simulates the distribution of circumferential strain at crown of pipe elbows where cracks occur under cyclic loads and presents the cyclic hardening behavior of pipe elbows. The parametric FE analysis showed that consistent simulated test results could be obtained when the test section of the ring specimen is longer than 1/2 of the inner diameter of the ring specimen and the radius of the inner loading jig is less than 1/4 of the inner diameter of the specimen.

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF

Cognitive Style and Interpersonal Problem Solving Ability among 5-, 7-, and 9-year-olds (아동의 인지양식과 대인 문제 해결력 - 5세, 7세, 및 9세 아동을 대상으로 -)

  • Chyung, Yun Joo;Yi, Soon Hyung
    • Korean Journal of Child Studies
    • /
    • v.14 no.1
    • /
    • pp.77-89
    • /
    • 1993
  • The purpose of this study was to investigate (1) children's field dependence by age and sex, (2) children's interpersonal problem solving ability by age, sex, and contextual factors, (3) children's interpersonal problem solving ability by field dependence. The subjects were 120 five-, seven-, and nine-year-olds. Children's field-dependence was measured with the Children's Embedded Figures Test (CEFT). Children's interpersonal problem solving ability was measured with the Preschool Interpersonal Problem Solving Test (PIPS Test). Statistical methods adopted for data analysis were frequencies, percentiles, means, standard deviation, t-test, oneway ANOVA. $Scheff{\acute{e}}$ test and Pearson's correlations. Major findings were that (1) The older children were more field-independent than the younger ones (2) The older children suggested more problem solving methods and higher-level problem solving strategies than the younger ones. (3) Children suggested higher-level problem solving strategies in contexts involving familiar as opposed to unfamiliar participants and contexts involving children as opposed to adults. (4) 9-year-olds' field-independence was positively associated with interpersonal problem solving ability.

  • PDF

A Nonparametric Goodness-of-Fit Test for Sparse Multinomial Data

  • Baek, Jang-Sun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.2
    • /
    • pp.303-311
    • /
    • 2003
  • We consider the problem of testing cell probabilities in sparse multinomial data. Aerts, et al.(2000) presented $T_1=\sum\limits_{i=1}^k(\hat{p}_i-p_i)^2$ as a test statistic with the local polynomial estimator $(\hat{p}_i$, and showed its asymptotic distribution. When there are cell probabilities with relatively much different sizes, the same contribution of the difference between the estimator and the hypothetical probability at each cell in their test statistic would not be proper to measure the total goodness-of-fit. We consider a Pearson type of goodness-of-fit test statistic, $T=\sum\limits_{i=1}^k(\hat{p}_i-p_i)^2/p_i$ instead, and show it follows an asymptotic normal distribution.

  • PDF