• 제목/요약/키워드: Test 1.1 & 2.1

검색결과 37,530건 처리시간 0.074초

Synthesis and Properties of Bio-Thermoplastic Polyurethanes with Different Isocyanate Contents

  • Li, Xiang Xu;Sohn, Mi Hyun;Cho, Ur Ryong
    • Elastomers and Composites
    • /
    • 제54권3호
    • /
    • pp.225-231
    • /
    • 2019
  • Bio-based polyester polyol was synthesized via esterification between azelaic acid and isosorbide. After esterification, bio-based polyurethanes were synthesized using polyester polyol, 1,3-propanediol as the chain extender, and 4,4'-diphenylmethane diisocyanate, in mixing ratios of 1:1:1.5, 1:1:1.8, 1:1:2, and 1:1:2.3. The bio TPU (Thermoplastic Polyurethane) samples were characterized by using FT-IR (Fourier Transform Infrared Spectroscopy), TGA (Thermal Gravimetric Analysis), DSC (Differential Scanning Calorimetry), and GPC (Gel Permeation Chromatography). The mechanical properties (tensile stress and hardness) were obtained by using UTM, a Shore A tester, and a Taber abrasion tester. The viscoelastic properties were tested by an Rubber Processing Analyzer in dynamic strain sweep and dynamic frequency test modes. The chemical resistance was tested with methanol by using the swelling test method. Based on these results, the bio TPU synthesized with the ratio of 1:1:2.3, referred to as TPU 4, showed the highest thermal decomposition temperature, the largest molecular weight, and most compact matrix structure due to the highest ratio of the hard segment in the molecular structure. It also presented the highest tensile strength, the largest elongation, and the best viscoelastic properties among the different bio TPUs synthesized herein.

스텝박스와 탄력밴드를 이용한 하지근력강화운동이 지역사회 노인의 균형능력과 하지근력에 미치는 영향 (The Impact of Lower Extremity Strengthening Exercise with Step Box and Elastic Band on Balance Ability and Lower Extremity Muscular Strength in Community-living Elderly Individuals)

  • 김두섭;최임순;김선엽
    • 대한물리의학회지
    • /
    • 제11권1호
    • /
    • pp.11-21
    • /
    • 2016
  • PURPOSE: This study was examined the effects of aerobic exercise using a step box and lower extremity strengthening exercise with an elastic band on the balance ability and lower extremity muscular strength in elderly subjects. METHODS: Forty-one healthy adults were randomly divided into experimental group 1 (Exp 1, n=14), experimental group 2 (Exp 2, n=14), and a control group (n=13). The Exp 1 conducted lower limb strengthening exercise using an elastic band and the Exp 2 performed aerobic exercise with a step box 50 minutes per day, twice per week, for eight weeks. RESULTS: There was significant increase in the Exp 1 and Exp 2 in comparison of the change of lower limb muscle strength according to measurement time (p<.05). But there was no significant difference according to intervention methods. In one-leg standing test change among the three groups after the intervention, the Exp 1 and Exp 2 saw significant improvement compared to the control group (p<.05) but there was no significant difference according to intervention methods. The change of the functional reaching test results, the Exp 1 and Exp 2 saw significant improvement according to the time of measurement. In the change of the Timed Up and Go test, there was significant improvement in the Exp 1 and Exp 2 compared to the control group (p<.01), but there was no significant difference according to intervention methods. CONCLUSION: Exercise to lower extremity strengthening program accompanied with aerobic exercise is considered more effective in dynamical balance and ability to walk.

전자빔 공정을 적용한 1,4-dioxane의 제거특성 및 독성평가 (Decomposition Characteristics of 1,4-dioxane in an E-beam Process and Toxicity Assessment)

  • 황혜영;장순웅
    • 한국지반환경공학회 논문집
    • /
    • 제12권2호
    • /
    • pp.63-68
    • /
    • 2011
  • 본 연구의 목표는 전자빔 공정을 적용하여 1,4-dioxane의 제거효율 및 독성평가를 하는 것이다. 이 실험에서는 전자빔 선량과 1,4-dioxane의 초기 농도에 따른 저감 효율 및 scavenger gas에 따른 무기화의 정도를 알아보았다. 또한 녹조류 중 하나인 Pseudokirohneriella Subcapitata를 이용하여 생물독성과 위해성 평가를 통한 독성저감기술을 확립하였다. 그 결과 1,4-dioxane은 전자빔 조사량이 증가할수록 분해 효율이 향상되었고, Radical Scavenger gas에 의한 TOC 제거는 $N_2O$$O_2$를 용해시켰을 때 효율이 증가되었다. 4일(96hrs) 후 독성평가 결과 전자빔 조사 강도의 증가에 따라 독성 영향이 저감되는 것을 알 수 있었다.

탐진강 수질측정 지점 간 동질성 검정을 위한 비모수적 자료 분석 (A Non-parametric Analysis of the Tam-Jin River : Data Homogeneity between Monitoring Stations)

  • 김미아;이수웅;이재관;이정섭
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.651-658
    • /
    • 2005
  • The Non-parametric Analysis is powerful in data test especially for the non- normality water quality data. The data at three monitoring stations of the Tam-Jin River were evaluated for their normality using Skewness, Q-Q plot and Shapiro-Willks tests. Various constituent of water quality data including temperature, pH, DO, SS, BOD, COD, TN and TP in the period of January 1994 to December 2004 were used as dataset. Shapiro-Willks normality test was carried out for a test 5% significance level. Most water quality data except DO at monitoring stations 1 and 2 showed that data does not normally distributed. It is indicating that non-parametric method must be used for a water quality data. Therefore, a homogeneity was conducted by Mann-Whitney U test (p<0.05). Two stations were paired in three pairs of such stations. Differences between stations 1, 2 and stations 1, 3 for pH, BOD, COD, TN and TP were meaningful, but Tam-Jin 2 and 3 stations did not meaningful. In addition, a narrow gap of the water quality ranges is not a difference. Categories in which all three pairs of stations (1 and 2, 2 and 3, 1 and 3) in the Tam-Jin River showed difference in water quality were analyzed on TN and TP. The results of in this research suggest a right analysis in the homogeneity test of water quality data and a reasonable management of pollutant sources.

Masking Level Difference: Performance of School Children Aged 7-12 Years

  • de Carvalho, Nadia Giulian;do Amaral, Maria Isabel Ramos;de Barros, Vinicius Zuffo;dos Santos, Maria Francisca Colella
    • Journal of Audiology & Otology
    • /
    • 제25권2호
    • /
    • pp.65-71
    • /
    • 2021
  • Background and Objectives: In masking level difference (MLD), the masked detection threshold for a signal is determined as a function of the relative interaural differences between the signal and the masker. Study 1 analyzed the results of school-aged children with good school performance in the MLD test, and study 2 compared their results with those of a group of children with poor academic performance. Subjects and Methods: Study 1 was conducted with 47 school-aged children with good academic performance (GI) and study 2 was carried out with 32 school-aged children with poor academic performance (GII). The inclusion criteria adopted for both studies were hearing thresholds within normal limits in basic audiological evaluation. Study 1 also considered normal performance in the central auditory processing test battery and absence of auditory complaints and/or of attention, language or speech issues. The MLD test was administered with a pure pulsatile tone of 500 Hz, in a binaural mode and intensity of 50 dBSL, using a CD player and audiometer. Results: In study 1, no significant correlation was observed, considering the influence of the variables age and sex in relation to the results obtained in homophase (SoNo), antiphase (SπNo) and MLD threshold conditions. The final mean MLD threshold was 13.66 dB. In study 2, the variables did not influence the test performance either. There was a significant difference between test results in SπNo conditions of the two groups, while no differences were found both in SoNo conditions and the final result of MLD. Conclusions: In study 1, the cut-off criterion of school-aged children in the MLD test was 9.3 dB. The variables (sex and age) did not interfere with the MLD results. In study 2, school performance did not differ in the MLD results. GII group showed inferior results than GI group, only in SπNo condition.

Masking Level Difference: Performance of School Children Aged 7-12 Years

  • de Carvalho, Nadia Giulian;do Amaral, Maria Isabel Ramos;de Barros, Vinicius Zuffo;dos Santos, Maria Francisca Colella
    • 대한청각학회지
    • /
    • 제25권2호
    • /
    • pp.65-71
    • /
    • 2021
  • Background and Objectives: In masking level difference (MLD), the masked detection threshold for a signal is determined as a function of the relative interaural differences between the signal and the masker. Study 1 analyzed the results of school-aged children with good school performance in the MLD test, and study 2 compared their results with those of a group of children with poor academic performance. Subjects and Methods: Study 1 was conducted with 47 school-aged children with good academic performance (GI) and study 2 was carried out with 32 school-aged children with poor academic performance (GII). The inclusion criteria adopted for both studies were hearing thresholds within normal limits in basic audiological evaluation. Study 1 also considered normal performance in the central auditory processing test battery and absence of auditory complaints and/or of attention, language or speech issues. The MLD test was administered with a pure pulsatile tone of 500 Hz, in a binaural mode and intensity of 50 dBSL, using a CD player and audiometer. Results: In study 1, no significant correlation was observed, considering the influence of the variables age and sex in relation to the results obtained in homophase (SoNo), antiphase (SπNo) and MLD threshold conditions. The final mean MLD threshold was 13.66 dB. In study 2, the variables did not influence the test performance either. There was a significant difference between test results in SπNo conditions of the two groups, while no differences were found both in SoNo conditions and the final result of MLD. Conclusions: In study 1, the cut-off criterion of school-aged children in the MLD test was 9.3 dB. The variables (sex and age) did not interfere with the MLD results. In study 2, school performance did not differ in the MLD results. GII group showed inferior results than GI group, only in SπNo condition.

진동하는 익형(NACA0012)의 공력특성 : Re~$8x10^5$, k<0.1

  • 조태환;윤성준;장병희
    • 항공우주기술
    • /
    • 제4권2호
    • /
    • pp.36-41
    • /
    • 2005
  • 진동하는 익형(NACA0012)의 공력특성을 KARI 1m 풍동에 설치된 익형진동장치를 사용하여 시험적으로 측정하였다. 사용된 익형의 기준시위는 0.2m 스팬은 0.75m이다. 익형표면에 설치된 스트레인-게이지 형식의 압력센서를 사용하여 측정된 압력을 적분하여 익형의 양력과 피칭모멘트를 계산하였다. 시험조건은 표준진동계수 k<01, Re~820,000, Mach<0.25이며, 시험결과를 타 기관에서 시험한 결과와 비교하였다.

  • PDF

로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가 (Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife)

  • 정영준;정재홍;임광채;조은주
    • 대한방사선치료학회지
    • /
    • 제21권1호
    • /
    • pp.1-7
    • /
    • 2009
  • 목 적: 로봇 사이버나이프에서 환자의 움직임에 의한 기준점의 위치변화 오차가 위치인식시스템(target location system, TLS) 을 통하여 targeting error값이 정확히 보정(correction)되는지 평가하고자 한다. 대상 및 방법: 본 실험은 targeting의 정확성을 분석하기 위해 head and neck팬텀에 Gafchromic 필름(MD-55)을 삽입한 후, 사이버나이프(CyberKnife Robotic Radiosurgery System G4, Accuray, US)의 6 MV X선을 조사하였다. 필름 분석은 Accuray사에서 제공하는 End to End (E2E) 프로그램을 이용하였다. 기준점의 위치에서 x, y, z방향으로 $0{\pm}0.2\;mm$, roll, pitch, yaw방향으로 $0{\pm}0.2^{\circ}$ 이내로 유지하여 12회 조사한 대조군과 인위적으로 움직임을 주어 실험을 시행한 6회의 실험군의 targeting 오차를 구하고, 대조군과 실험군의 평균값에 대한 유의성을 t-검정을 통해 분석하였다. 또한, gamma-index method (dose difference: 3%)를 통해 2차원적 선량분포의 일치성을 distance to agreement (DTA)를 각각 1 mm, 1.5 mm, 2 mm로 달리하여 정량화하고, 비교 분석하였다. 결 과: E2E test 시행 결과, 기준 필름의 targeting 평균오차 0.405 mm, 표준편차 0.069 mm, 실험 필름의 평균오차 0.413 mm, 표준편차 0.121 mm으로 나왔으며, t-검정 결과 유의확률 P=0.836 (신뢰구간 95%)으로 두 집단에서 유의한 차이를 볼 수 없었다. 또한, DTA를 각각 1 mm, 1.5 mm, 2 mm로 선량분포의 일치성을 비교한 결과 기준필름 3,314개 위치에서 axial필름 평균은 각각 95.04%, 97.56%, 98.13%, sagittal필름 평균은 각각 95.47%, 97.68%, 98.47% 일치하였다. 실험필름과 비교한 결과 3,323개 위치에서 axial필름 평균은 각각 96.38%, 97.57%, 98.04%, sagittal필름 평균은 각각 95.50%, 97.87%, 98.36% 일치하는 것을 확인할 수 있었다. 결 론: 로봇 사이버나이프는 치료 시 환자의 움직임에 의해 발생하는 기준점의 위치변화 오차를 실시간 추적하여 보정하며, targeting 오차를 1 mm 이내, 선량분포는 95% 이상 일치하는 정확성을 확인할 수 있었다.

  • PDF

수생태계 독성평가에 적용 가능한 국내 시험종 선정 (Domestic Test Species for Aquatic Toxicity Assessment in Korea)

  • 안윤주;남선화;이재관
    • 생태와환경
    • /
    • 제40권1호
    • /
    • pp.1-13
    • /
    • 2007
  • 본 연구에서는 국제적으로 이용되고 있는 생태독성 시험종 중에서, 국내 생태독성 평가에 적용 가능한 시험종을 파악해보았다. 대상 화학물질 41개 항목에 대해 수집된 생태독성 시험종은 총 265종으로, 이 중 국내 생태독성 평가에 적용 가능한 시험종은 총 71종으로 분류되었다. 생물 분류군별로 살펴보면, 어류 7종, 무척추동물군 26종 중 환형동물 2종, 태형동물 2종, 갑각류 13종, 곤충류 3종, 연체동물 4종, 편형동물 1종, 원생동물 1종, 식물군 26종 중 규조류 9종, 녹조류 14종, 대형수생식물 3종, 기타군 12종 중 양서류 2종, 세균류 3종, 남조류 6종, 균류 1종이다. 생태독성 시험종 중 국내 시험종의 비율을 살펴보면, 26.8%로 국내 생태독성 평가에 적용 가능한 시험종이 그리 넉넉하지 않은 실정임을 알 수 있다. 따라서 국내 생태독성 평가에 적용 가능한 국내 시험종을 개발하고 더 나아가 국내종을 이용한 생태독성 시험법을 정립함으로써 국내 생태독성 평가를 위한 독성자료 구축연구가 장기적으로 추진되어야 할 것으로 사료된다.

Status of Occupational Therapists on Unilateral Neglect Test Tools Usage and Symptom Classification

  • Jang, Woo-Hyuk
    • The Journal of Korean Physical Therapy
    • /
    • 제29권5호
    • /
    • pp.271-275
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the current status of the use of neglect test tools and the awareness for egocentric neglect (EN) and allocentric neglect (AN). Methods: A survey questionnaire was distributed to occupational therapists attending continuing education at the Daegu-Gyeongbuk branch on April 16. A total 143 responses were collected, and with the exception of 5 incomplete responses, 138 of them were analyzed. Results: The most commonly used unilateral neglect test tools were the line bisection test (86 responses, 62.3%), cancellation test (35 responses, 25.4%), copy and drawing test (7 responses, 5.1%). In a follow-up survey of 86 respondents who used line bisection tests as the most commonly used test, the majority (82 responses, 95.3%2) were found to use the 20-line test paper. In question about the familiarity and education experience for test manual, only 20 responses (23.2%) and 3 responses (3.5%) answered 'Yes'. In a question about the experience of a manual and the article for the manual, 25 responses (29.1%) answered 'Yes'. In the question regarding the separation of EN and AN on the unilateral neglect test, 44 responses (31.9%) were 'distinction' and 94 responses (68.1%) were 'no distinction'. Conclusion: Information on the guidance and interpretation of the line bisection test is lacking and the concept of EN and AN was insufficient.