• Title/Summary/Keyword: Test 1.1 & 2.1

Search Result 37,430, Processing Time 0.068 seconds

Studies on the Adhesion Part 1 The adhesive force of Chloroprene Rubber to Plywood material (접착(接着)에 관(關)한 연구(硏究)(제1보(第1報)) 접착력시험조건(接着力試驗條件)에 따른 접착력(接着力)에 관(關)하여)

  • Lee, Myung-Whan;Park, Chang-Ho
    • Elastomers and Composites
    • /
    • v.8 no.2
    • /
    • pp.140-147
    • /
    • 1973
  • The influence of the adhesive force test conditions on the resultant adhesive force was measured using a chloroprene rubber as an adhesive and a plywood as an adherent. It was clarified from the experiments which adhesive force test conditions could influence strongly the adhesive force. After this, the constant values neccessary as the test conditions of the adhesive force in making generally a test of the adhesive force determined.

  • PDF

Physicochemical Properties and Degradation of New Oral Cephalosporins (새로운 경구용 세팔로스포린류의 물리화학적 성질 및 분해특성)

  • La, Sung-Bum;Kim, Wan-Joo;Jee, Ung-Kil
    • YAKHAK HOEJI
    • /
    • v.38 no.2
    • /
    • pp.123-130
    • /
    • 1994
  • Physicochemical properties and hydrolysis kinetics of new some oral cephalosporins were examined in buttered solution and human plasma or rat liver homogenate. The test cephalosporins were 7-[(Z)-2-(2-aminothiazole-4-yl)-2- methoxyiminoacetamido]-3-[4-(2-pyridyl)piperazinyl] thiocarbonylthhiomethyl-3-cephem-4-carboxylic acid (CEN1), 7-[(Z)-2-(2-aminoth iazole-4-yl)-2-methoxyiminoacetamido]-3-[4-(2-pyrimidyl)piperazinyl]th iocarbonylthiomethyl-3-cephem-4-carboxylic acid (CEN2), pivaloyloxymethyl-7-[ (Z)-2-(2-aminothiazole-4-yl)-2-methoxyiminoacetamido]-3-[4-(2-pyridyl)piperazi nyl]thiocarbonylthiomethy1-3-cephem-4-carboxylate (CEN1P), and pivaloyloxymethyl-7-[(Z)-2-(2-aminothiazole-4-yl)-2-methoxyiminoacetamido]-3-[ 4-(2-pyrimidyl)piperazinyl]thiocarbonyl-thiomethyl-3-cephem-4-carboxylate (CEN2P). The partition coefficient(Ko/w) of CEN1P, CEN2P were higher than those of CEN1, CEN2. The calculated pKa values of CEN1, CEN2, CEN1P, and CEN2P were 7.09, 7.75, 4.92, and 5.39, respectively. The hydrolysis of CEN1P and CEN2P were not depend on the composition of pH of the test medium except weak alkaline buffered solution (pH 8.00). CEN1 and CEN2 were very stable in pH 6.80 and 8.00 buffer solutions. CEN1P and CEN2P were rapidly deesterified to CEN1 and CEN2 in human plasma and in rat liver homogenate. Half-lives$(t_{1/2})$ of CEN1 and CEN2 were 3.49 and 4.93 hr in human plasma, 1.47 and 1.26 hr in rat liver homogenate, respectively.

  • PDF

High Temperature Tensile Strength and Fatigue Life Characteristics for Reduced Activation Ferritic Steel (JLF-1) by TIG Welding (TIG 용접한 저방사화 페라이트강 (JLF-1)의 고온강도 및 피로수명특성)

  • Yoon, Han-Ki;Lee, Sang-Pill;Kim, Sa-Woong;Kohyama, Akira
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1444-1450
    • /
    • 2003
  • The fatigue life and tensile strength of JLF-1 steel (Fe-9Cr-2W-V-Ta) and its TIG weldment were investigated at the room temperature and $400^{\circ}C$. Four kinds of test specimens, which associated with the rolling direction and the TIG welding direction were machined. The base metal of JLF-1 steel represented almost anisotropy in the tensile properties for the rolling direction. And the base metal of JLF-1 steel showed lower strength than that of TIG weldment. Also, the strength of all materials entirely decreased in accordance with elevating test temperature. Moreover, the fatigue limit of weld metal was largely increase than that of base metal at both temperatures. The fatigue limit of JLF-1 steel decreased in accordance with elevating test temperature. The fatigue limit of JLF-1 steel decreased in accordance with elevating test temperature. The SEM fractography of tensile test specimen showed conspicuous cleavage fracture of a radial shape. In case of fatigue life test specimen, there were so many striations at crack initiation region, and dimple was observed at final fracture region as a ductile fracture mode.

Association of Lower Socioeconomic Status and SARS-CoV-2 Positivity in Los Angeles, California

  • Allan-Blitz, Lao-Tzu;Goldbeck, Cameron;Hertlein, Fred;Turner, Isaac;Klausner, Jeffrey D.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.54 no.3
    • /
    • pp.161-165
    • /
    • 2021
  • Objectives: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spreads heterogeneously, disproportionately impacting poor and minority communities. The relationship between poverty and race is complex, with a diverse set of structural and systemic factors driving higher rates of poverty among minority populations. The factors that specifically contribute to the disproportionate rates of SARS-CoV-2 infection, however, are not clearly understood. Methods: We evaluated SARS-CoV-2 test results from community-based testing sites in Los Angeles, California, between June and December, 2020. We used tester zip code data to link those results with United States Census report data on average annual household income, rates of healthcare coverage, and employment status by zip code. Results: We analyzed 2 141 127 SARS-CoV-2 test results, of which 245 154 (11.4%) were positive. Multivariable modeling showed a higher likelihood of SARS-CoV-2 test positivity among Hispanic communities than among other races. We found an increased risk for SARS-CoV-2 positivity among individuals from zip codes with an average annual household income

Review of pulmonary function test in terms of insurance medicine (폐기능검사의 보험의학적 이해)

  • Lee, Sinhyung
    • The Journal of the Korean life insurance medical association
    • /
    • v.33 no.2
    • /
    • pp.8-11
    • /
    • 2014
  • Pulmonary function test is a group of tests which are composed of measurement for lung function. Thy are spirometry, blood-gas analysis, lung volumes, exercise test, diffusion capacity, and bronchial challenge test. In this article, I will review the pulmonary function test and it's application in terms of clinical aspect and insurance medicine. The standard spirometric indicies are forced vital capacity(FVC), forced expiratory volume at 1 second(FEV1), and the ratio of FEV1 over FVC(FEV1/FVC). If the value of FEV1/FVC less than 70%, the examinee has obstructive ventilatory dysfunction.

  • PDF

Shear Bond Strength Between Zirconia and Porcelain (지르코니아와 포세린의 전단결합강도)

  • Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: To examine the shear bond strengths of zirconia and veneering ceramic according to their surface processing. Methods: The test samples were divided into three groups: one without zirconia surface processing, one sandblasted, and one sandblasted then 3% etched. Then veneering ceramic was fired on all test samples, and their shear bond strengths were measured. Results: The test samples of the control group (Z1) showed the lowest shear bond strengths of $21.82{\pm}1.02$ MPa. The shear bond strengths of Z2 and Z3 ($28.25{\pm}0.72$ and $26.23{\pm}0.82$ MPa, respectively) were relatively higher than those of the control group. The fracture surface of the control group showed adhesive fractures while the test groups had relatively large numbers of cohesive fractures. Conclusion: The shear bond strength was high in the test groups with surface processing while the fracture surfaces showed compound fractures of adhesive and cohesive fractures.

Ground Ejection Tests to verify the Safe Separation of an Aircraft Mounted Store (항공기 장착 무장의 투하 안정성 검증을 위한 지상무장분리시험)

  • Lee, Jong-Hong;Choi, Seok-Min;Lee, Min-Hyoung;Lee, Chul;Jung, Jae-Won
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.70-75
    • /
    • 2018
  • The mounted store on an aircraft shall be subjected to an ground separation test to verify that a safe separation has been made before it is actually installed to the aircraft. In this study, ground ejection test was conducted with dummy missile to verify the stability of the drop on the land. Bomb rack unit essential to testing ground ejection test, operate at high pressure and produce a significant ejection force to push the missile away from any large orifice. Bomb rack unit modified their bombe pressure and orifice diameter to photograph the drop movement of dummy missile with high-speed camera and to analyze their drop displacement and speed. It is considered useful to provide the initial data for the ejection force analysis on aircraft with actual flight and to carry out the ground separation tests of aircraft with future developments.

Obtaining Reference Intervals of HbA1c by Immunoturbidimetry (면역비탁법에 의한 HbA1c의 참고범위 설정)

  • Kim, Jae-Sub;Park, Ki-Hyun;Yu, Sun-Woo;Lee, Bum-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.2
    • /
    • pp.62-66
    • /
    • 2009
  • HbA1c is the major fraction of glycated hemoglobin, and used primarily to identify the average plasma glucose concentration over prolonged periods of time, mostly 2-3 months. It is used as markers for the diagnosis and monitoring of diabetic patients and increasingly used a marker in health screening check up for general populations. In this study, HbA1c was measured with Cobas integra 800 (Roche Diagnostics, Mannheim, Germany), using immunoturbidimetry principles. We established the reference interval for HbA1c with Cobas integra 800 and evaluated its significance. The study subjects were 36,140 (male 57.5%, and female 42.2%) who visited the Health Promotion Center of a tertiary care center in Seoul for health checkup from January to September, 2008. HbA1c levels were measured with immunoturbidimetric method. Statistical evaluation was done with SPSS. Comparison between male and female was checked with Mann-Whitney test, and among age groups with Kruskal-Wallis test. Reference interval for HbA1c was from 4.8% to 6.1%. There was no significant difference between male and female with Mann-Whitney test (P=0.539). There was significant difference among age groups with Kruskal-Wallis test (P<0.05). Reference interval for HbA1c with Cobas integra 800 was 4.8~6.1%, which was different from conventional one, 4.4-6.4%. Establishment of reference interval for each principle is needed.

  • PDF

Stability of Li[Co0.1Ni0.15Li0.2Mn0.55]O2 Cathode Material for Lithium Secondary Battery (리튬 2차 전지용 Li[Co0.1Ni0.15Li0.2Mn0.55]O2 양극물질의 안정성 고찰)

  • Park, Yong-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.5
    • /
    • pp.443-449
    • /
    • 2007
  • The structural and thermal stability of $Li[Co_{0.1}Ni_{0.15}Li_{0.2}Mn_{0.55}]O_2$ electrode during cycling process was studied. The sample was prepared by simple combustion method. Although there were irreversible changes on the initial cycle, O3 stacking for $Li[Co_{0.1}Ni_{0.15}Li_{0.2}Mn_{0.55}]O_2$ structure was retained during the first and subsequent cycling process. Impedance of the test cell was decreased after the first charge-discharge process, which would be of benefit to intercalation and deintercalation of lithium ion on subsequent cycling. As expected, cycling test for 75 times increased impedance of the cell a little, instead, thermal stability of $Li[Co_{0.1}Ni_{0.15}Li_{0.2}Mn_{0.55}]O_2$ was improved. Moreover, based on DSC analysis, the initial exothermic peak was shifted to high temperature range and the amount of heat was also decreased after cycling test, which displayed that thermal stability was not deteriorated during cycling.

A Experimental Study on Window Glass Breakage in Compartment Fires (구획 화재시 창유리 파괴 현상에 관한 실험적 연구)

  • 이수경;김종훈;최종운;이정훈
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.21-30
    • /
    • 1998
  • This is a study on the relation of window glass breaking time, shape, and vent condition in a compartment fire through the experiment. We recognize the phenomenon that window glass breakage in a compartment fire be arose from the thermal stresses due to the temperature temperature difference was 233.4$^{\circ}C$ for test 1-3, 138$^{\circ}C$ for text 2-1, 83.6$^{\circ}C$ for test 2-2. The interior test 2-2, 400.9$^{\circ}C$ for test 2-3. so if the flame didn't reach at the surface of window glass, the breakage of glass occure at 40$0^{\circ}C$~50$0^{\circ}C$. when the fire size reached to 1541.14kW, the window might be broken by thermal stress. But window glass was not collapsed.

  • PDF