• Title/Summary/Keyword: Test 1.1 & 2.1

Search Result 37,530, Processing Time 0.065 seconds

A Study on Correlation Between Accelerated Corrosion Test and Long-term Exposure Test According to the Temperature Condition (온도조건에 따른 철근부식 촉진시험과 장기폭로시험의 상관성에 관한 연구)

  • Park, Sang-Soon;So, Byung-Tak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.203-208
    • /
    • 2016
  • In this study, to clarify the differences rebar corrosion beginning, through the actual corrosion accelerated test in corrosion time and laboratory test chamber of the structure of the marine environment results in both environments, it is an object of correlation coefficient derived. The accelerated corrosion test was carried out by two case, I.e., one is $20^{\circ}C$ of low temperaure codition(case 1), and the other is $65^{\circ}C$ of high temperaute codition(case 2). Whether corroions occurs, it was measures using half-cell potential method. The results indicated that case 2 is to acclerate the corrosion of rebar about 1.7~1.8 times as compared with case 1, thenthe corrosion of rebar embadded in concrete occurred according to the order of OPC60, FA, BS, OPC35. Correlation coefficient between acclerated corrosion test and long-term exposure test, case 1 is 2.45 to 2.94, and case 2 is 4.37~4.99.

The Primality Test (소수 판별법)

  • Lee, Sang-Un;Choi, Myeong-Bok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.8
    • /
    • pp.103-108
    • /
    • 2011
  • Generally, Miller-Rabin method has been the most popular primality test. This method arbitrary selects m at k-times from m=[2, n-1] range and (m,n)=1. Miller-Rabin method performs $k{\times}r$ times and reports prime as $m^d\;{\equiv}\;1(mod\;n)$ or $m^{2^rd}\;{\equiv}\;-1(mod n)$ such that n-1=$2^sd$, $0\;{\leq}\;r\;{\leq}\;s-1$. This paper suggests more simple primality test than Miller-Rabin method. This test method computes c=$p^{\frac{n-1}{2}}(mod\;n)$ for k times and reports prime as c=-1. The proposed primality test method reduces $k{\times}r$ times of Miller-Rabin method to k times.

A study on the periodontal status of second molar adjacent third molar (제 3대구치와 인접한 제 2대구치의 치주상태에 대한 고찰)

  • Lee, Hae-Doo;Hong, Ki-Seok;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.489-502
    • /
    • 2006
  • The purpose of this study was to determine the relationship between the third molar and periodontal status of the adjacent second molar. Fifty patients who had four maxillary and mandibular second molars were consecutively selected for the study subjects. The subjects provided a total of 200 molars, i. e., 100 maxillary and 100 mandibular molars, and classified the groups as follows; third molars that are normally erupted are control group, that are impacted are test 1 group, that are simply extracted are test 2 group, that are surgically extracted are test 3 group. Probing depth, plaque index, gingival index and mobility were measured. The results were as follows. 1. In mesial probing depth, there was no significantly difference. In distal probing depth, there was a significantly difference between control group and test 1 & 3 group in maxilla and between control & test 2 group and test 1& 3 group in mandible(p<0.05). 2. In buccal probing depth, there was a significantly difference between test 2 group and test 3 group in mandible. In lingual probing depth, there was a significantly difference between control group and test 1 & 3 group in mandible(p<0.05). 3. In plaque index, there was a significantly difference between test 1 group and test 2 group in maxilla, between test 1 group and control & test 2 group in mandible(p<0.05). 4. In gingival index, there was a significantly difference between control group and test 1 & 3 group in mandible. In mobility, there was no significantly difference(p<0.05). As a result of this study, the second molars adjacent to the third molars that are impacted or surgically extracted had poor prognosis, so impacted third molars should be extracted in early time and the second molars are actively treated for periodontal health.

The Effect of Test Anxiety,Intelligence, and Item Arrangement Order on Test Performance in Earth Science (시험불안(試驗不安) 지능(知能) 및 문항배렬(問項配列) 방식(方式)이 지구과학(地球科學) 의험수행(議驗遂行)에 미치는 효과(效果))

  • Kim, Sang-Dal;Yi, Hyang-Sun;Hwang, In-Ho
    • Journal of The Korean Association For Science Education
    • /
    • v.11 no.2
    • /
    • pp.161-178
    • /
    • 1991
  • This study was designed to investigate the effect of test anxiety, intelligence, and item arrangement order on test performance in Earth Science. The main purposes in this study were to investigate (1) (2) (3) (4) on test performance.: (1) the effect of test anxiety components on test performance in Earth Science. (2) the effect of item arrangement order on test performance in Earth Science. (3) the effect of test anxiety This study was designed to investigate the effect of test anxiety, intelligence, and item arrangement order on test performance in Earth Science. The main purposes in this study were to investigate (1) (2) (3) (4) on test performance.: (1) the effect of test anxiety components on test performance in Earth Science. (2) the effect of item arrangement order on test performance in Earth Science. (3) the effect of test anxiety components on test performance in Earth Science according to learner's intelligence levels. (4) test effect of item arrangement order on learner's intelligence. The hypothesis was that there is difference among test achievements scores according to (1) test anxiety-worry levels. (2) item arrangement orders. (3) item arrangement orders on test anxiety-worry levels. (4) test anxiety-worry levels on intelligence levels. (5) test anxiety-emotionality levels. (6) item arrangement orders on test anxiety-emotionality levels. (7) test anxiety-emotionality levels on intelligence levels. (8) item arrangement orders on intelligence levels. The test items selected for this study were derived from the text Science (part 1) first grade of high school. The subjects of this study were 164 of high school first grade boy students in Pusan. They were assigned to one of the three groups, according to test anxiety levels.: (1) upper 25% of total subjects designated to high group (2) middle 50% (3) low group, lower 25% of total subjects And according to LQ. (1) upper 25% of total subjects designated to high group. (2) middle 50%. (3) low group, lower 25% of total subjects Analysis of variance was used in this study for hypothesis examination. The dependent variable was the achievement scores of Earth Science test and independent variables were test anxiety(worry, emotionality) level, LQ. level, item arrangement orders. The principal findings of the present study are as follows: (1)Test achievement score trend decreases as the test anxiety (worry, emotionality) increases although the result is not statistically significant. (2)There is no significant difference among test achievement scores according to item arrangement orders. (3)The higher the LQ. is, the more effective test anxiety. And the LQ. has significant interaction effect with test anxiety. (4)There is significant interaction effect between the LQ. levels and itemqr arrangement orders.

  • PDF

Prevalence of toxoplasma antibody in swine by microplate latex agglutination test in Kyeongnam district (Latex 응집반응에 의한 경남중부지역 돼지의 톡소플라즈마병 항체조사)

  • Lee, Byung-hoon;Kim, Cha-yong;Suh, Myung-deuk
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.2
    • /
    • pp.263-268
    • /
    • 1993
  • This study was conducted to detect the serum antibody of toxoplasma in swine from breeding-pig, rearing-pig farm and slaughtered pig in abattior by latex agglutination(LA) test. The perfomance of LA test was carried out with commercial Toxo-MT kit(Eiken Chemical Co.)by Tsubota and Ozawa's method. The cut-off titer of positive and negative reactions by Toxo-MT antigen used in this experiment was determined as the serum titer of 1 : 32. Positive rate of toxoplasma antibody from the total of 823 serum samples by LA test was 17.0%(140 cases). And positive rates of toxoplasma antibody against serum samples of 194 from breeding-pig farm, 273 from rearing-pig farm and 356 from abattior were 91 cases(46. 9%), 23 cases(8.4%) and 26 cases(7.3%), respectively. The distributions of serum antibody titers in 823 test sera by LA test were shown 51 cases(36.3%) in 1:32, 40(28.6%) in 1:64, 17(12.1%) in 1:128, 14(10.0%) in 1:256, 3(2.1%) in 1:512, 5(3.6%) in 1:1024 and 3(2.1%) in 1:2048. The ranges of positive rate from the sera in each group of breeding-pig farms were 20~61.9%.

  • PDF

Theory and Practice in the Tensile Strength Test for Split Ring Shaped Rock Specimen (터진고리 형태의 암석시편에 대한 인장강도 시험의 이론과 실제)

  • Choi, Byung-Hee;Lee, Youn-Kyou;Park, Chan;Park, Chulwhan
    • Explosives and Blasting
    • /
    • v.38 no.1
    • /
    • pp.30-37
    • /
    • 2020
  • In this study the split ring (SR) test was investigated for its applicability to the measurement of the tensile strength of rock specimen of NX size. The concept of the SR test is the same as the half ring (HR) test (Choi et al., 2019) except that the expected fracture plane is perpendicular to the loading direction. Because of this perpendicularity, however, it was believed that the SR test could be more accurate than the HR test. Like the HR specimen, the SR specimen is a curved prismatic bar with a uniform section. Appealing to a basic bending theory in strength of materials, the tensile strength for the special bar can be calculated analytically. Numerical simulations using LS-DYNA revealed, as expected, that the strength errors were 1% and 5% for the tensional and compressional SR tests, respectively, which were much lower than that (12%) of the HR test. To identify the performance of the two SR tests, laboratory experiments were conducted. The HR and Brazilian tests were also performed for comparison. The experiments showed that the ratios of the tensional and compressional SR to Brazilian strengths were 1.2~1.4 and 1.1~1.2, respectively, which are too small compared to empirical values in ordinary bend tests. Consequently, it is concluded that the SR test is not appropriate for use in tensile strength test of rock specimen of NX size. But the ratio of the HR to Brazilian strengths was within 1.7~2.0 for both the previous and present studies, showing a good consistency in their test results.

A study on characteristics and physiological variables of chest pain induced by exercise test in angina suspected patients (협심증이 의심되는 환자에서 운동부하검사로 유발되는 흉통의 양상과 생리적 변인에 관한 연구)

  • Cho, Mi-Kyoung;Choe, Myoung-Ae
    • Journal of Korean Biological Nursing Science
    • /
    • v.2 no.2
    • /
    • pp.1-19
    • /
    • 2000
  • The purpose of this study was to identify the characteristics and physiological variables of chest pain induced by exercise test in angina suspected patients. The subjects of this study consisted of 28 inpatients and outpatients aged between 40 and 75 who underwent treadmill test at exercise testing laboratory of S-University from January 2000 to June 2000. Subjects were interviewed with questionnaire regarding sociodemography, the past health history and history related to chest pain before the exercise test. Subjects were interviewed with questionnaire concerning quality, intensity, duration of chest pain induced by walking on the treadmill(Marquette, U.S.A. 1992) according to Bruce protocol following exercise test. Systolic and diastolic blood pressure were measured before, during and after the test, heart rate was determined by ECG. The results of this study were as follows ; 1) Quality of chest pain induced by exercise test were feeling stiffness 19(67.9%), heavy 10(36.0%), exploded 9(32.1%), crushing, suffocating, tight 8(28.6%), stuffy, prickly 7(25.0%), burning 6(21.4%), clasp 5(17.9%), cleaved, tensed, piercing 3(10.7%), perfectly fitting, sore 2(7.1%), tearing, tingling, ticklish, heartburn 1(3.6%). 2) Mean score of VAS(intensity of pain) following exercise test was $5.79{\pm}2.27$ and mean duration of chest pain after the test was $7.83{\pm}5.31$ minutes. 3) Sites of chest-pain induced by exercise test were middle site 11(39.3%), left-chest 10(35.6%), right-chest 6(21.5%). Radiation site of chest-pain was neck(18.0%), right flank site 1(3.6%), left shoulder & arm 2(7.1%) and back 1(3.6%). 4) Symptoms other than chest-pain induced by exercise test were dyspnea 21(75.6%), perspiration 14(50.4%), fatigue 12(43.2%), leg-pain 11(39.6%), dizziness 7(25.2%) anxiety toward chest-pain 3(10.8%), thirst 2(7.1%), and palpation, headache and tingling sensation of hand and leg 1(3.6%). 5) Mean MET(intensity of exercise) during the exercise test was $7.64{\pm}2.57$ and mean RPE(rating of perceived exertion) was $15.89{\pm}2.36$. Mean duration of exercise was $6.79{\pm}2.88$. 6) correlation coefficients between RPE and VAS was 0.500(p=0.003), those between MET and VAS was 0.287(p=0.069) and those between either depression or elevation of ST segment and VAS was 0.236(p=0.114). 7) There was a significant difference in mean systolic pressure between before and after the test as $146.29{\pm}28.18mmHg$ and $177.96{\pm}28.82mmHg$(t=-5.640, p=0.000), a significant difference in mean diastolic blood pressure between before and after the test as $84.85{\pm}15.07mmHg$ and $88.89{\pm}13.72mmHg$(t=-2.082, p=0.047), and there was a significant difference in mean heart-rate between before and after the test as $81.89{\pm}12.22/min$ and $160.68{\pm}21.77/min$(t=-21.255, p=0.000).

  • PDF

Antimutagenic Effects of Ginsenoside Rb$_1$, Rg$_1$ in the CHO-K1 Cells by Benzo[a]pyrene with Chromosomal Aberration Test and Comet Assay

  • Kim, Jong-Kyu;Kim, Soo-Jin;Rim, Kyung-Taek;Cho, Hae-Won;Kim, Hyeon-Yeong;Yang, Jeong-Sun
    • Molecular & Cellular Toxicology
    • /
    • v.5 no.2
    • /
    • pp.126-132
    • /
    • 2009
  • The usage and types of chemicals are advancing, specializing, large-scaled increasing, and new chemical exposed workers are concerning to occupational disease. The generation of reactive oxygen in the body from carcinogen, mutation and DNA damage in cancer is protected by natural antioxidants (phytochemicals) with antimutagenic effect. There were many reports of ginsenoside Rb$_1$, Rg$_1$ grievances of the genetic mutation to suppress the effect confirm the genetic toxicity test with chromosomal aberration test and the Comet (SCGE) assay confirmed the suppression effect occurring chromosomal DNA damage. We had wanted to evaluate the compatibility and sensitivity between the chromosomal aberration (CA) test and the Comet assay. We used the CA test and Comet assay to evaluate the anti-genotoxicity of ginsenoside Rb$_1$ and Rg$_1$, in CHO-K1 (Chinese hamster ovary fibroblast) cell in vitro, composed negative control (solvent), positive control (benzo[a]pyrene), test group (carcinogen+variety concentration of ginsenoside) group. The positive control was benzo[a]pyrene (50 $\mu$M), well-known carcinogen, and the negative control was the 1 % DMSO solvent. The test group was a variety concentration of ginsenoside Rb$_1$, Rg$_1$ with 10$^{-8}$%, 10$^{-6}$%, 10$^{-4}$%, 10$^{-2}$%, 1%, 10%. In chromo-somal aberration test, we measured the number of cells with abnormally structured chromosome. In Comet assay, the Olive tail moment (OTM) and Tail length (TL) values were measured. The ratio of cell proliferation was increased 8.3% in 10$^{-8}$%, 10$^{-6}$%, 10$^{-4}$%, 10$^{-2}$%, 1%, 10% Rb$_1$ treated groups, and increased 10.4% in 10$^{-10}$%, 10$^{-8}$%, 10$^{-6}$%, 10$^{-4}$%, 10$^{-2}$%, 1% Rg$_1$ treated groups. In the CA test, the number of chromosomal aberration was decreased all the Rb$_1$ and Rg$_1$ treated groups. In the Comet assay, the OTM values were decreased in all the Rb$_1$ and Rg$_1$ treated groups. To evaluate the compatibility between CA and Comet assay, we compared the reducing ratio of chromosomal abnormalities with its OTM values, it was identified the antimutagenicity of ginsenoside, but it was more sensitive the CA test than the Comet assay. Ginsenoside Rb$_1$ and Rg$_1$ significantly decrease the number of cells with chromosomal aberration, and decrease the extent of DNA migration. Therefore, ginsenoside Rb$_1$, Rg$_1$ are thought as an antioxidant phytochemicals to protect mutagenicity. The in vitro Comet assay seems to be less sensitive than the in vitro chromosomal aberration test.

SAT#1 (Preliminary Integration) Test Results of KASS System

  • Jeong, Hwanho;Jang, HyunJin;Kim, Koontack;Lee, Jaeeun;Lee, ByungSeok
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.2
    • /
    • pp.145-151
    • /
    • 2021
  • According to the Korea Augmentation Satellite System (KASS) system milestone, Site Acceptance Test (SAT) has three steps test until the end of the project. SAT#1 is the first time of SAT steps and verify the KASS Reference Station (KRS) and Sub System (S/S) for the monitoring and controllable. After the equipment and software were installed at the Mission Control Center (MCC) with Central Monitoring and Control Simulator (CMS) for the SAT#1, the 1:1 test was progressed when the KRS and S/S are ready to test. SAT#1 has a 10 steps test case and it was progressed each KRS sites. The test was finished throughout the real-time monitoring and the data collection including the data analysis all of the 7 KRS sites. Finally SAT#1 was completed on December 2020 with successfully.

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.