• 제목/요약/키워드: Test 1

검색결과 60,398건 처리시간 0.067초

약인성 간손상 환자에게 협진을 위한 한약의 추가 처방이 간수치에 미치는 영향에 대한 증례보고 (A Case Report of the Effect of Korean Medicine on Liver Function Test of Drug-Induced Liver Injury Patient Treated with Western Medicine)

  • 이보람;김원일
    • 대한한의학방제학회지
    • /
    • 제22권1호
    • /
    • pp.193-200
    • /
    • 2014
  • Objective : The purpose of this study is to report that patient diagnosed as drug-induced liver injury treated with herbal and western medicine improve liver function test. Methods : We treated the patient diagnosed as drug-induced liver injury caused by antibiotics with Hepatotonics and Cheonggan-tang Gagam(淸肝湯加減). Then, We followed up the result of liver function test. After the result of liver function test improved, we diagnosed the patient with Korean medical methods, and evaluated the symptom of Cerebral infarction and liver function test treating the patient with Jihwangumja (地黃飮子). Result : After our treatment, Liver function test and symptoms of Cerebral infarction result improved. Conclusion : Use of Western medicine with herbal medicine can improved liver function test of drug-induced liver injury effectively and herbal medicine do not disturb the liver function.

정강뼈 돌림에 따른 오버테스트의 엉덩관절 모음 각도와 엉덩정강뼈 환 길이의 상관관계 (The Relationship Between Hip Adduction Angle of Ober Test According to Tibial Rotation and Length of the Iliotibial Band)

  • 박주희;이사겸
    • 대한물리의학회지
    • /
    • 제12권1호
    • /
    • pp.43-49
    • /
    • 2017
  • PURPOSE: This study investigated the relationship among hip adduction angle, tibial rotation, and ITB length during an Ober test to determine the most appropriate position for performing the test. METHODS: The study included thirty-nine asymptomatic participants (23 males, 16 females). Their hip adduction angles were measured using the Ober test during three tibial rotation conditions (internal tibial rotation, external rotation, and neutral position). ITB length was calculated by measuring the position of the patella to lateral femoral condyle using ultrasonography (patella-condyle distance; PCD). RESULTS: The relationship among hip adduction angle, tibial rotation, and ITB length was analyzed under the three conditions using the Pearson correlation. The hip adduction angle of the internal tibial rotation, the external rotation, and the neutral position were significantly related to ITB length. Moreover, the hip adduction angle measured during the internal tibial rotation had the highest correlation with ITB length among the three conditions (r=.58, p<.001). CONCLUSION: Internal tibial rotation caused by the Ober test led to increased iliotibial band (ITB) tension and a decreased adduction angle. These findings support that tibial rotation influences the flexibility of ITB. Therefore, therapists should consider the position of the internal tibial rotation when taking measurements using an Ober test.

피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구 (A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester)

  • 정기석;길형준
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

마하 5 스크램젯 엔진의 내부 유동 공력 시험 (Internal Flow Aerodynamic Test of a Mach 5 Scramjet Engine)

  • 양인영;이양지;김영문;이경재;강상훈;양수석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.584-587
    • /
    • 2011
  • 마하 5 스크램젯 엔진에 대하여 연소 시험에 대한 예비 시험 성격으로서 연료 분사 없이 내부 유동 공력 시험을 수행하였다. 엔진은 흡입구 크기 $70mm{\times}200mm$, 전체 길이 1.7m의 시험용 모델을 대상으로 하였다. 설비는 한국항공우주연구원이 자체 설계 개발하여 보유한 불어내기식 극초음속 시험 설비를 사용하였다. 측정은 엔진 내부 유로를 따라 19개 지점에서 압력을 측정하였다. 시험 결과 본 엔진 모델을 사용하여 설비 시동이 가능하였으며 엔진 내부는 초음속 유동이 유지됨을 확인하였다.

  • PDF

A large-scale test of reinforced soil railway embankment with soilbag facing under dynamic loading

  • Liu, Huabei;Yang, Guangqing;Wang, He;Xiong, Baolin
    • Geomechanics and Engineering
    • /
    • 제12권4호
    • /
    • pp.579-593
    • /
    • 2017
  • Geosynthetic reinforced soil retaining walls can be employed as railway embankments to carry large static and dynamic train loads, but very few studies can be found in the literature that investigate their dynamic behavior under simulated wheel loading. A large-scale dynamic test on a reinforced soil railway embankment was therefore carried out. The model embankment was 1.65 meter high and designed to have a soilbag facing. It was reinforced with HDPE geogrid layers at a vertical spacing of 0.3 m and a length of 2 m. The dynamic test consisted of 1.2 million cycles of harmonic dynamic loading with three different load levels and four different exciting frequencies. Before the dynamic loading test, a static test was also carried out to understand the general behavior of the embankment behavior. The study indicated the importance of loading frequency on the dynamic response of reinforced soil railway embankment. It also showed that toe resistance played a significant role in the dynamic behavior of the embankment. Some limitations of the test were also discussed.

A Study on the Accelerated Life Test for Evaluating the Reliability of Nickel-Cadmium Batteries

  • Kwon, Soo-Ho;Huh, Yang-Hyun;Lim, Tae-Jin
    • International Journal of Reliability and Applications
    • /
    • 제1권1호
    • /
    • pp.89-104
    • /
    • 2000
  • Accelerated testing consists of a variety of test methods for shortening the life of products or hastening the degradation of their performance. This paper presents practical, modern statistical methods for evaluating the reliability of Nickel-Cadmium batteries at their design temperature of 2$0^{\circ}C$ by accelerated life test. Batteries have been life tested at three high temperature conditions, 50, 60, 7$0^{\circ}C$, respectively to yield failures quickly. The failures have been observed and judged by means of charge and discharge current integration. Analyses of life data from those conditions resulted in the Weibull distribution, which has been verified on the ground of the Kolmogorov-smirnov test and the pairwise t-test. Life data are modeled according to the Arrhenius life-temperature relationship. The mean life of tested batteries is assessed at about 590 cycles, and the activation energy of this chemical reaction is concluded to be 0.39eV as results. This study provides procedures for estimating the reliability of batteries in a short period, which has little been possible in domestic industries. The results can be applied in many fields such as proof testing, acceptance testing, and estimating assurance periods.

  • PDF

대학생(大學生)의 Coffee와 음료(飮料)섭취가 stress 및 건강상태(健康狀態)의 상관성(相關性)에 관한 연구(硏究) (A Study on the interrelation between stress and condition of health in dringking coffee and beverage)

  • 최공한;류영수
    • 동의신경정신과학회지
    • /
    • 제6권1호
    • /
    • pp.71-84
    • /
    • 1995
  • This paper is for studying interrelation between Stress perception, Todai Index(THI) test and coffee. this study was done on 163 college women whose ages were 18 to 33 and who were in University in Wonju. The Stress perception test and THI test shows the following results. 1. The Stress test on the group that drunk coffee and beverage shows high degree of oppression sense about school and daily life. 2.The total THI test on the group that drunk coffee shows high degree of complaint on mouth, evacuation and lie scale, but shows the lowest piont on nervousrness. 3. The D-group womrn who drink a cup of coffee, two or three show the highest complaint on mouth and evacuation. E-group shows the lowest lie scale. 4 The Stress test and health examination on the group that drunk coffee show high degee of stress. And it also shows stimulative relation between the condition of body health and drinking coffee. The above shows that coffee and some beverage can affect on mental and physical health. Especially they are considered as a factor of stimulus on stress response. Through the THI test, the effect on mouth and evacuation, lie scale and nervousness could be obseved. So the drinking coffee and beverage requires circumspection.

  • PDF

근력강화운동이 노인의 균형수행력에 미치는 영향 (Effect of Balance Performance in the Elderly by the Strengthening Exercise)

  • 김은주;이한숙;김종열;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제11권2호
    • /
    • pp.149-161
    • /
    • 1999
  • The purpose of study wan to compare the effect of balance performance in the elderly by the strengthening exercise. Thirty-one health elderly women aged 60 to 79 years participated in this study. Participants were divided into exercise(21) and control group(10). Exercise participants received strengthening exercise for 45 minutes in three times a week for 6 weeks while control subjects continued their normal activities, Exercise included resisted hip flexion, extension, abduction and adduction, knee flexion and extension, ankle dorsiflexion and plantrarflexion. All subjects were assessmented clinical test of sensory interaction and balance. one leg stance test, Berg balance test. Exercise and control subjects were teated before, midway through, and at the end of the trial. These collected data were analyzed by using oneway and repeated ANOVA, scheffe's test, 1-test and correlation. The results of this study were as fellows. 1. There were statistically significant difference in balance performance clinical teat of sensory interaction, and balance(p<.01), one leg stance test(p<.05), Berg balance test(p<.05) by the strengthening exercise. 2. There was correlation between static balance and dynamic balance(p<.01). 3. There was correlation between static balance and weight(p<.05), dynamic balance and height(p<.01), and weight(p<.01).

  • PDF

국제표준에 대비한 국내 비자동저울의 품질평가에 관한 연구 (Quality Assessment of Domestic Non-automatic Weighing Instruments for International Standards)

  • 남궁재관;공재향
    • 한국공작기계학회논문집
    • /
    • 제13권6호
    • /
    • pp.127-134
    • /
    • 2004
  • As the result of reduction of the barrier of national economy on matters of quality assurance of weighing instruments in recently, it is considering in domestic as well as international matters. Therefore, this study is to analysis and compare with international md national measuring standards on the electric self-indicating scale, to improve the quality of electronic machine by providing a reformation plan on currently problems of domestic manufactured, and to identify to introduce in domestic criteria from international standards. I had compared KSC 1313 to OIML R 76-1 as the performance assessment items, such as metrology Properties test, static temperature test, temperature effect testing under the un-load, electronic wave disturbance test, high-tempereature and high-humidity stability test and durability test. Therefore, only one company is passed all items of the test according to the international (reference) standards, but it is possible to improve the quality in general if it should be use the load cell and electric components which is stability of temperature change in order to supplementation to the static temperature test and temperature effect testing under the un-load. It is also possible to apply in the domestic with the OIML 76-1 after correcting the design.

디지털 방사선 투과영상의 식별도 평가 연구 (The Study on Image Sensitivity Evaluation For Digital Radiography Image)

  • 박상기;이영호
    • 동력기계공학회지
    • /
    • 제12권6호
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study is to compare the quality of digital radiography image with that of classical film images for welded structure in power plants. The CMOS(Complementary Metal Oxide Semiconductor) flat panel detecter and Agfa D5 film are used to image flaw specimens respectively. In the test, CMOS flat panel detector has been determined to have a better image than that of film image. In the IQI(Image Quality Indicator) transmission test, one or two more line can be seen in digital image than in film image. Digital Radiography Test enabled to successfully detect all defects on the weld specimens fabricated with real reheat stem pipe and boiler tube as well. In the specific comparison test, Digital radiography test detected micro flaws in the size of 0.5 mm in length by 0.5 mm in depth. However, film test has limited it to 1.0 mm in length by 1.0 mm in depth. As a result of this study, digital radiography technology is estimated well enough to perform the inspection in the industry with far more cost effective way, compared to the classical film test.

  • PDF