• Title/Summary/Keyword: Test 1

Search Result 60,115, Processing Time 0.071 seconds

Deformation Behaviour of Metamorphic Tuff from Plate Loading Test

  • Lee, Young-Nam;Suh, Young-Ho;Kim, Dae-Young
    • Geotechnical Engineering
    • /
    • v.13 no.3
    • /
    • pp.87-100
    • /
    • 1997
  • This paper presents the results of plate loading test and discontinuum analysis, carried out to study the deformation behaviour and determine the deformation modulus of !rletamorphic andesitic tuff found at the site of a underground oil storage facility in Korea. In the plate loading test, the maximum pressure of 14MPa was applied to the bedrock by using a flat jack(1m in diameter) and the rock anchor system for the reaction against the applied pressure. The values of deformation modulus obtained from this test were compared with those of laboratory test, biaxial test and pressuremeter test. The deformation modulus from plate loading test was generally about half of the intact rock modulus, and the mass modulus of the bedrock at the test site may be affected by discontinuities and ranges between 25 and 350pa. Discontinuum analysis was also performed to simulate plate loading test and study the influence of discontinuities on the deformability of rock mass by simulating the presence of joints at the test area.

  • PDF

Neurobehavioral Effects of Chronic Exposure to Organic Solvents among Dock Yard Painters (만성적 유기용제 폭로로 인한 조선업 도장공들의 신경행동학적 영향에 관한 연구)

  • Cho, Young Sook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.6 no.1
    • /
    • pp.53-71
    • /
    • 1997
  • Across sectional study was performed to evaluate the chronic effects on central nerve system(CNS) of cumulative exposure of complex organic solvents, using neurobehavioral test. Subjects were 66 (male) dock yard painters of some large ship industry which is located in Ulsan. The neurobehavioral test battery used in this study was NCTB (Neurabehavioral Core Test Battery recommended by WHO(World Health Organization), which consisted of 7 items-Profile of mood states (POMS), Simple reaction time, Santa Ana dexterity test. Digit span, Digit symbol, Benton visual retention test and Pursuit aiming. The subjects were classified by 3 groups according to duration of employment(group 1 ; less than 9 years, group 2 ; 10-14 years, group 3 ; more than 15 years). The results of performance were analyzed considering of work duration, age, educational level, alcohol drinking, smoking and testing time as confounding factors. Benton visual retention test, pursuit aiming correct dot and sum of dot showed significant differences among the groups, and decreased with increasing work duration. It indicated that the mean scores of performance ability were lowering according to work duration. Besides, the tests that didn't show statistical significances but showed linear trends were depression-dejection, vigor, fatigue of POMS, slowest time of simple reaction time and digit span forward. Most of the neurobehavioral test items were correlated with age and educational level. After controlling of confounding factors-age and educational level, the results followed ; digit span backward was different significantly. Tension-anxiety, depression-dejection, anger-hostility of POMS, SD and slowest time of simple reaction time, Santa Ana dexterity test non-preferred hand, digit span forward, Benton visual retention test and pursuit aiming correct dot decreased with increasing of work duration. The correlation analysis was done in order to find out the relationship between subjective symptom and the scores of neurobehavioral core test battery. According to the results of analysis there were no items that had statistical significant relationship(p<0.05).

  • PDF

Human Papillomavirus Prevalence and Genotype Distribution in Normal and ASCUS Specimens: Comparison of a Reverse Blot Hybridization Assay with a DNA Chip Test

  • Kim, Sunghyun;Lee, In-soo;Lee, Dongsup
    • Biomedical Science Letters
    • /
    • v.21 no.1
    • /
    • pp.32-39
    • /
    • 2015
  • High-risk (HR) human papillomavirus (HPV) genotypes are strongly associated with cervical cancer, whereas other HPV genotypes are not. To identify the various HPV genotypes in clinical samples, we conducted HPV genotyping using a DNA chip test and reverse blot hybridization assay (REBA) in normal cytology samples and atypical squamous cells of undetermined significance (ASCUS) cytology samples. We also investigated the HPV infection rate and HPV genotype prevalence in women with normal cytology and ASCUS cytology. Liquid-based cytology preparations were used for the initial screening of 205 subjects with normal cytology and ASCUS cytology. The HPV infection rate was 49.8% when using the DNA chip assay and 61.0% when using the REBA test. In patients with normal cytology, the HR-HPV positive rate was 21.9% with the DNA chip assay and 43.9% with the REBA test. In contrast, 8.3% of patients with ASCUS were HR-HPV positive when using the DNA chip assay, and 13.6% were positive when tested with the REBA test. The infection rate of HR-HPV in the 40~50-year age group was significantly higher than that of the other age groups. Based on the cytological analysis of the normal and ASCUS samples, the five most prominent HPV genotypes were HPV 16, 18, 68, 33, and 58 using the DNA chip test, and they were HPV 16, 18, 53, 33, and 66 when using the REBA test. In conclusion, the findings show that the results of the REBA test are comparable to those of the DNA chip test. Most strikingly, the REBA test detected the HR-HPV genotype associated with cervical carcinoma similar to that detected with the DNA chip method. Therefore, the REBA test is a useful method to detect clinically important HR-HPV genotypes.

Prediction of Ballistic Limit for Composite Laminates Subjected to High-velocity Impact Using Static Perforation Test (정적압입 관통 실험을 이용한 복합재 적층판의 고속충격 탄도한계속도 예측)

  • You, Won-Young;Kim, In-Gul;Lee, Seokje;Kim, Jong-Heon
    • Composites Research
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • The ballistic limit of Carbon/Epoxy composite laminates with the finite effective area are predicted by using the quasi-static perforation test and semi-empirical formula. The perforation energy were calculated from force-displacement curve in quasi-static perforation test. Also, the actual ballistic limit and penetration energy were obtained through the high-velocity impact test. The quasi-static perforation test and high-velocity impact test were conducted for the specimens with 3 different effective areas. In the high-velocity impact test, the air gun impact tester were used, and the ballistic and residual velocity was measured. The required inputs for the semi-empirical formula were determined by the quasi-static perforation tests and high-velocity impact tests. The comparison between semi-empirical formula and high-velocity impact test results were conducted and examined. The ballistic limits predicted by semi-empirical formula were agreed well with high-velocity impact test results.

On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

  • Kim, Jong-Bum;Jeong, Ji-Young;Lee, Tae-Ho;Kim, Sungkyun;Euh, Dong-Jin;Joo, Hyung-Kook
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1083-1095
    • /
    • 2016
  • The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V&V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodiumshowed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

Assessment of Flight Control Performance based on the Ground Test Results of Smart UAV (스마트 무인기의 지상시험을 통한 비행제어 성능분석)

  • Kang, Young-Shin;Park, Bum-Jin;Yoo, Chang-Sun;Kim, Yu-Shin;Koo, Sam-Ok
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • The tilt-rotor Smart UAV(Unmanned Air Vehicle) has been developed by KARI(Korea Aerospace Research Institute) for civil purposes. In order to prove the reliabilities of total system of Smart UAV, the series of ground tests were performed including system interface test, aircraft HILS(Hardware In the Loop Simulation) Test, ground power test, 4-DOF (Degrees of Freedom)rig test, and tethered hover test. Many unexpected problems occurred at each ground test. With clearing these problems, the total Smart UAV systems were matured and the airworthiness was proven enough. After complete of additional ground test proposed by FRRB(Flight Readiness Review Board), the first flight test will be performed in this year. This paper presents the procedures and the analysis results of the ground tests for the tilt-rotor Smart UAV.

A Study on Toughened Glass Used for Vehicles and Its Testing Methods (자동차용 강화유리와 그 시험방법에 대한 연구)

  • Ahn, Ho-soon;Kwon, Hea-boung;Lee, Kwang-bum;Jeon, Sang-woo;Son, Young-san
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.3
    • /
    • pp.14-18
    • /
    • 2015
  • Toughened glass is known to have about four times larger external impact resistance than that of original glass. This study is aimed to verify that ceramic-printed toughened glass does not meet of GTR(Global Technical Regulations) No. 6 and its strength is lower than that of original glass through tests. The tests were conducted on the test pieces of original glass, toughened glass, and ceramic-printed toughened glass from five glass manufacturers. In Test 1, a 227g steel ball was dropped from a height of 2 meters, and damage was checked according to the test method of GTR No. 6. In Test 2, a steel ball was freely dropped from different heights and limited damage height was determined. In the result of Test 1 according to the test method of GTR No. 6, while all five test pieces of toughened glasses were not damaged, all the ceramic-printed toughened glass from the five manufacturers were damaged. In the result of Test 2, none of the five test pieces of toughened glass were damaged by a 10m ball drop, meanwhile, the original glasses were damaged by an average of 3m ball drop. And the results of the tests show that the ceramic-printed toughened glass does not have the features of toughened glass due to its very low strength. Therefore, this study contributes to the safety of consumers by considering the GTR No. 6, and by revising the toughened glass test method.

The Effects of Integrating Vibration Into Stabilization Exercise on Balance and Disability in Patients With Chronic Low Back Pain (진동자극 환경에서의 요부 안정화 운동이 만성요통환자의 균형능력 및 기능장애수준에 미치는 영향)

  • Son, Chang-hwan;Moon, Young;Choi, Jong-duk
    • Physical Therapy Korea
    • /
    • v.26 no.1
    • /
    • pp.19-27
    • /
    • 2019
  • Background: Compared to healthy people, patients with chronic lower back pain have reduced balance abilities which may cause proprioception problems, patients with chronic lower back pain avoid physical activities due to pain, and reduced activity levels lead to muscle weakening, which can further exacerbate pain. Recently, there have been many studies on the use of sensory stimulation; and among these studies, interventions that use vibrational stimulation have shown functional improvements in the patients. Objects: This study examined the effects of a stabilization exercise with vibration stimulation on the balance ability and disability in patients with chronic back pain. Methods: The subjects of the study were 30 persons who were randomly assigned to the experimental group and the control group, with 15 subjects in each. The subjects were evaluated before and after intervention via a balance ability test, the Korean Oswestry disability index (KODI) test, a pain test, and a proprioceptive sensory test. Both groups received general physical therapy. The experimental group performed the stabilization exercise with vibration stimulation, and the control group performed a general stabilization exercise, three times a week for six weeks. Results: After the intervention, both groups showed significant improvements in the balance ability test, the KODI test, the pain test, and the proprioceptive sensory test. The experimental group showed statistically significant, higher improvements than the control group in the balance ability test, the KODI test, and the proprioceptive sensory test. Conclusions: The stabilization exercise with vibration stimulation for patients with chronic back pain has been reported to provide greater functional improvements than the conventional intervention method. Therefore, the stabilization exercise in a vibration stimulation environment could be a useful intervention for patients with chronic back pain.

Research on Management of Test of Proficiency in Koeran(TOPIK) for the disabled examinee (장애인을 위한 한국어능력시험(TOPIK) 운영 방법에 대한 연구 - 시각장애인 응시자를 중심으로 -)

  • Jung, Seung-Yeon;Hwang, Ji-You
    • Journal of Korean language education
    • /
    • v.25 no.1
    • /
    • pp.169-201
    • /
    • 2014
  • The purpose of this research is to analyze the problems of the way of the 32th TOPIK(advanced)'s management for the disabled examinee and to prescribe the management of the TOPIK for them. Since the TOPIK started in 1997, the number of examinee who take it as a qualifying exam for the university entrance have gradually increased. The first disabled examinee who wants to use the result of the TOPIK for entrance into the post graduated university took the 32th TOPIK(advanced level). However, there was no examination regulations and detailed management method for the disabled. The biggest problem was the examinee could not have braille test and answer. The exam supervisor read all that is printed on the test sheet. It caused two big problems. 1) The essay question in writing test became an oral test. 2) The strategies of answering to multiple choice questions could not be used in vocabulary/grammar, writing, listening, and specially reading section. The first problem is occurred because writing and speaking have different cognitive process. The second one can be strongly related to the result in reading section. Above all, these disrupt accurate assessment of the examinee's writing and reading achievement. Therefore, this research insists the TOPIK needs to have the regulation and prescribe the management for the disabled. This research suggests 5 regulations for the blind examinee which covers the test time, supervisor, place and request of the examinee. These refer to the regulation for the disable in the other tests, such as the college scholarship ability test, TOEFL, TEPS, and a civil service exam.

A Study on the Development of Physical Examination with VR Content and User Satisfaction (VR 콘텐츠를 이용한 신체검사 개발 및 사용자 만족도 연구)

  • An, Ho-Won;Kim, Jun-Min
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.318-326
    • /
    • 2021
  • This study aims to the effectiveness of physical examination using VR contents to solve problems such as the increase in chronic diseases and shortage of professional manpower in the health care field according to the aging and low birth rate, and to provide efficient healthcare. Therefore, this study implemented a one-stop VR content physical examination system by wearing HTC VIVE Pro VR and a stick controller. The system is from step 1 to step 5, and the final body age is determined and a simple solution is provided through five steps sequentially: color blind test, memory test, audiogram test, reaction speed test, and instantaneous cognitive ability test. In addition, for the one-stop VR content physical examination system developed by this study, as a result of verifying the user satisfaction for normal people who visited the health examination center and VR/AR clinical trial center of certified tertiary hospital in Daejeon, the overall satisfaction and the intention to reuse Was high, and according to gender, there was a significant difference in the 5-step test, and according to the age, there were significant differences in the 4-step test and the 5-step test.