• Title/Summary/Keyword: Test & Evaluation (T&E)

Search Result 199, Processing Time 0.26 seconds

치과임플란트 치료와 관련된 상악구치부의 임상적 연구 (CLINICAL STUDY ON KOREAN POSTERIOR MAXILLAE RELATED TO DENTAL IMPLANT TREATMENT)

  • 이두한;이성현;황주홍;이정근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권1호
    • /
    • pp.27-31
    • /
    • 2010
  • Purpose of study: The purpose of this study was to provide adequate diagnostic guideline for the maxillary sinuses prior to dental implant treatment for edentulous posterior maxillary areas. For this purpose, our procedure involves the estimation of the remaining alveolar bone height, the examination of the anatomical variation in the maxillary sinuses (e.g. sinus septum), and the evaluation of the incidence of preoperative pathological conditions in the maxillary sinuses. Materials and Methods: We selected 189 patients to undergo computerized tomography (CT) in order to account for the posterior maxillary anatomy found in patients of Korean ethnicity. We evaluated the following using Dentascan software: Remaining alveolar bone height, incidence of sinus septum, and rate of preoperative pathologic conditions in the maxillary sinus. The average amount of remaining alveolar bone height was analyzed using the student's t-test for differences according to anatomical site, and the ANOVA was used for the differences according to age group with the level of significance set at 0.05. Results: Alveolar bone heights of upper first premolar, second premolar, first molar, and second molar was 12.24 mm, 10.37 mm, 7.16 mm, and 7.15 mm, respectively with statistical significance (P < 0.05). Incidence of sinus septum as an anatomic variation was 17 out of 189 cases (9.0%). Incidence of mucosal thickening as a pathologic variation was 82 out of 189 cases (43.4%). Conclusion: In treatment planning of posterior maxillary edentulous area of Koreans, the consideration of augmentation surgery for maxillary sinus is required in maxillary molar area before dental implant installation, and preoperative screening of the asymptomatic maxillary sinuses can be regarded as a reasonable preoperative procedure in the planning of dental implant treatment on the posterior maxillary edentulous area.

관절염질환자의 관절가동범위에 대응한 착탈의 동작평가 (The Motion Evaluation of Arthritis Patients' Dressing and Undressing Corresponding to their Joint Range of Motion)

  • 한승희;최미성
    • 한국의상디자인학회지
    • /
    • 제14권2호
    • /
    • pp.75-87
    • /
    • 2012
  • This study aims at measuring and comparing the joint range of motion(ROM) of the elderly, quantitatively understanding the joint ROM and duration for their dressing and undressing of pants with 3D motion analysis equipment, and thereby providing basic data necessary for the future development of clothes carrying functional designs. The findings are as follows. As for the study method, the 9-item joint ROM measurements were conducted with goniometer, and the questionnaire analyses were carried out for t-test, ANOVA, and regression analysis with spss12.0 program. The 3D motion analyses were handled with 3D Motion Analysis Package Version 3.1 Program. The findings are as follows. First, the ROM was shown to be significantly low, as the arthritis-pain consciousness level was felt higher by the subject than the average one. Seven ROM variables, such as hip flexion, hip adduction, hip internal rotation, hip external rotation, knee flexion, ankle dorsiflexion, and ankle plantar flexion, were shown to significantly affect the discomfort level experienced at the time of dressing or undressing. Second, in the motion of inserting the remaining leg into the pant crotch part(3e), the difference of angles in the hip joint and knee joint was the largest between the women in their 20s and the elderly women with arthritis. Third.

  • PDF

편마비 환자의 단하지 보조기 착용유무에 따른 하지 체중지지율과 보행특성의 변화에 관한 연구 (A study on the immediate effects of weight distribution and gait patterns of hemiplegic patients through PLS on and off)

  • 김택훈;구애련;김종만
    • 한국전문물리치료학회지
    • /
    • 제3권2호
    • /
    • pp.55-76
    • /
    • 1996
  • The objective of this study was to identify the immediate effects of the short leg brace on the weight bearing distribution and gait patterns of hemiplegic patients. The subjects of this study were 18 hemiplegic patients who had been hospitalized or visited out-patient department of Rehabilitation Hospital, Yonsei University College of Medicine, from January 5, 1996 through March 23, 1996. PLS(Posterior Leaf Spring) on and off changes in gait patterns were measured using ink foot print as well as by recording weight bearing distribution using a limb load monitor. The data were analyzed by the correlation and paired t-test. The findings were as follows: 1. Eighteen subjects were more weighted on the affected leg when PLS was put off(42.74%) than on(40.08%). 2. The defference in gait patterns between PLS on and off was statistically significant, with an increase in step length by 1.7cm on the involved side; a decrease in foot angle by 4.41 degree on the involved side; and a narrowing of base of support by 1.46cm when PLS were off. In conclusion, this study showed that PLS did not affect the weight bearing distribution and gait patterns of hemiplegic patients. Since, the evaluation method used in this study has limitations in regard to temporal distance gait values. Further studies are required to numerous experiments for subject and extensive study.

  • PDF

Cytocompatibility and cell proliferation evaluation of calcium phosphate-based root canal sealers

  • Mestieri, Leticia Boldrin;Zaccara, Ivana Maria;Pinheiro, Lucas Siqueira;Barletta, Fernando Branco;Kopper, Patricia Maria Polli;Grecca, Fabiana Soares
    • Restorative Dentistry and Endodontics
    • /
    • 제45권1호
    • /
    • pp.2.1-2.7
    • /
    • 2020
  • Objectives: This study aimed to evaluate the cell viability and migration of Endosequence Bioceramic Root Canal Sealer (BC Sealer) compared to MTA Fillapex and AH Plus. Materials and Methods: BC Sealer, MTA Fillapex, and AH Plus were placed in contact with culture medium to obtain sealers extracts in dilution 1:1, 1:2 and 1:4. 3T3 cells were plated and exposed to the extracts. Cell viability and migration were assessed by 3-(4,5-dimethylthiazoyl)-2,5-diphenyl-tetrazolium bromide (MTT) and Scratch assay, respectively. Data were analyzed by Kruskal-Wallis and Dunn's test (p < 0.05). Results: The MTT assay revealed greater cytotoxicity for AH Plus and MTA Fillapex at 1:1 dilution when compared to control (p < 0.05). At 1:2 and 1:4 dilutions, all sealers were similar to control (p > 0.05) and MTA Fillapex was more cytotoxic than BC Sealer (p < 0.05). Scratch assay demonstrated the continuous closure of the wound according to time. At 30 hours, the control group presented closure of the wound (p < 0.05). At 36 hours, only BC Sealer presented the closure when compared to AH Plus and MTA Fillapex (p < 0.05). At 42 hours, AH Plus and MTA Fillapex showed a wound healing (p > 0.05). Conclusions: All tested sealers demonstrated cell viability highlighting BC Sealer, which showed increased cell migration capacity suggesting that this sealer may achieve better tissue repair when compared to other tested sealers.

Multi-dimensional wind vibration coefficients under suction for ultra-large cooling towers considering ventilation rates of louvers

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Tamura, Y.
    • Structural Engineering and Mechanics
    • /
    • 제66권2호
    • /
    • pp.273-283
    • /
    • 2018
  • Currently, the dynamic amplification effect of suction is described using the wind vibration coefficient (WVC) of external loads. In other words, it is proposed that the fluctuating characteristics of suction are equivalent to external loads. This is, however, not generally valid. Meanwhile, the effects of the ventilation rate of louver on suction and its WV are considered. To systematically analyze the effects of the ventilation rate of louver on the multi-dimensional WVC of ultra-large cooling towers under suctions, the 210 m ultra-large cooling tower under construction was studied. First, simultaneous rigid pressure measurement wind tunnel tests were executed to obtain the time history of fluctuating wind loads on the external surface and the internal surface of the cooling tower at different ventilation rates (0%, 15%, 30%, and 100%). Based on that, the average values and distributions of fluctuating wind pressures on external and internal surfaces were obtained and compared with each other; a tower/pillar/circular foundation integrated simulation model was developed using the finite element method and complete transient time domain dynamics of external loads and four different suctions of this cooling tower were calculated. Moreover, 1D, 2D, and 3D distributions of WVCs under external loads and suctions at different ventilation rates were obtained and compared with each other. The WVCs of the cooling tower corresponding to four typical response targets (i.e., radial displacement, meridional force, Von Mises stress, and circumferential bending moment) were discussed. Value determination and 2D evaluation of the WVCs of external loads and suctions of this large cooling tower at different ventilation rates were proposed. This study provides references to precise prediction and value determination of WVC of ultra-large cooling towers.

Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers

  • Tanomaru-Filho, Mario;Torres, Fernanda Ferrari Esteves;Pinto, Jader Camilo;Santos-Junior, Airton Oliveira;Tavares, Karina Ines Medina Carita;Guerreiro-Tanomaru, Juliane Maria
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.34.1-34.7
    • /
    • 2020
  • Objectives: This study evaluated by using micro-computed tomography (micro-CT) the filling ability and sealer apical extrusion promoted by a new Sealer Injection System (SIS; Angelus) with side openings needle, in comparison with the conventional injection system, associated with a new ready-to-use calcium silicate-based sealer (Bio-C Sealer). Materials and Methods: Acrylic resin models containing a main curved artificial canal and 3 simulated lateral canals in apical, middle and cervical thirds were used. The main root canals were prepared using a rotary system up to size 35.05. The canals were filled with Bio-C sealer by using a single cone technique and the conventional delivery system or SIS. Samples were scanned in micro-CT. The percentage of voids throughout the entire extension of the main root canal and in each third of the lateral canals, besides the apical extrusion of the sealer was calculated. Data were submitted to t-test (p < 0.05). Results: There was no difference between both systems in the main root canals filling. Although the volume percentage of voids was similar in the apical and middle thirds of lateral canals, SIS had the greatest filling ability of the cervical third lateral canal. Moreover, the conventional system showed the highest apical extrusion of the sealer. Conclusions: The conventional and SIS obturation systems had an appropriate filling ability of the main root canal. SIS had the best filling of the cervical third of the lateral canals, besides lower sealer apical extrusion, suggesting its clinical indication.

종합병원 간호사의 간호역량, 전문성 활동에 따른 임상경력관리체계 수정모형 (Revised Clinical Ladder System Model Based on Nurses' Clinical Competence and Professional Activities for Nurses in General Hospitals)

  • 조명숙;권인각;김경희;조용애
    • 임상간호연구
    • /
    • 제24권3호
    • /
    • pp.324-335
    • /
    • 2018
  • Purpose: The purpose of this study was to propose a revised Clinical Ladder System(CLS) Model for nurses based on the evaluation of clinical competence and professional activities of nurses working in general hospitals. Methods: Data were collected between September 10 and October 30, 2017. Participants were 50 head nurses from 10 general hospitals with over 400 beds located in Seoul City and Gyeonggi Province. Each head nurse evaluated clinical competence, qualifications, and professional activities of 5 staff nurses at each of the 5 levels of CLS in her unit. The total number of the nurses evaluated was 245. Data were analyzed with descriptive statistics and t-test, one-way ANOVA, and $Scheff{\acute{e}}$. Results: Over 80% of the nurses were university graduates. As the CLS levels increased, clinical competence, qualifications, and professional activities also increased significantly. Education material development and quality improvement activities were carried out by nurses from level 2, research and evidence based practice activities were carried out from level 3, and nurses at level 4 or 5 participated in most of the professional activities as leaders. Conclusion: In order to retain excellent nurses in general hospitals, recognizing and rewarding nurses according to the revised model of the CLS are recommended.

다양한 석고제품으로 제작한 석고 모형의 정확성의 평가: 3차원 이미지의 컴퓨터 지원 분석 (Three-dimensional evaluation of stone models made of various gypsum products)

  • 김욱태
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.321-325
    • /
    • 2020
  • Purpose: This study is to evaluate the accuracy of gypsum replica models made from various gypsum products. Methods: One main model was made of stainless steel by CNC milling process. Molds were formed from the main model, and the gypsum replica models were made using 8 types of type IV gypsum, 10 pieces each. The main model was digitized by a contact scanner (Incise; Renishaw) and the gypsum replicas were digitized by an optical scanner (E4; 3Shape A/S). The difference between the main model and the gypsum replicas were measured by inspection software (3D Systems). One-way ANOVA was performed to evaluate the statistical significance of differences between groups. In addition, the independent sample T test was performed to determine the difference between the conventional and scannable stone group (n=10, α=0.05). Results: The root mean square of the stone models were 7.24 ㎛ to 10.78 ㎛, and statistical significance was found between the two groups (SR, FR) and the other 6 groups (IS, SG, CA, CS, ER, EBG) (p<0.05). The accuracy of the gypsum replicas was 9.04 ㎛ and 7.62 ㎛ in the conventional and scannable stone group, respectively. There was statistical significance between the two groups (p<0.01). Conclusion: In the limited results of this study, the product with low setting expansion and the scannable showed high accuracy. Therefore, in order to obtain a stable and accurate scan model, it is more effective in terms of accuracy to use a scannable stone with a low setting expansion.

지역거점 공공병원의 수익성 결정요인 - COVID-19 유행기간을 중심으로 - (Determinants of Profitability of Regional Public Hospitals in Korea - Focusing on the COVID-19 Pandemic Period -)

  • 지석민;옥현민
    • 한국병원경영학회지
    • /
    • 제27권3호
    • /
    • pp.26-38
    • /
    • 2022
  • Purposes: We analyzed the profitability determinants of regional public hospitals during the entire period between 2010 and 2020 and the period before and after COVID-19. We intended to provide fundamental data for developing publicness evaluation index and task of establishing and expanding regional public hospitals. Methodology: The financial and non-financial information of the regional public hospitals were used as the main analysis data; The financial data was established by the Center for Public Healthcare Policy of National Medical Center, and the non-financial data by the Health Insurance Review and Assessment Service. T-test and regression analysis were used. Findings: The results can be summarized in two. First, the main determinants of profitability of the regional public hospitals were appeared to be the total asset turnover rate and the labor cost rate. Second, during the COVID-19 pandemic in the regional public hospitals, the number of sickbeds, the number of isolation rooms, the total asset turnover rate and the labor cost rate appeared to be the factor worsening the profitability. Practical Implication: The results of this study suggests that the management of the regional public hospitals is not aiming for the profit making, but it performs the functions as the community healthcare safety net such as controlling infectious diseases.

동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가 (Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan)

  • 이재상;이규찬;이승환;배성복;박종엽
    • 핵의학기술
    • /
    • 제20권1호
    • /
    • pp.59-65
    • /
    • 2016
  • 동적신장검사는 신장기능을 영상화하는 대표적인 방법이다. 동적신장검사에서 저선량 방사성의약품의 사용으로 기존 동적신장검사와 저선량을 사용한 신장검사의 비교를 통한 동적신장검사의 재현성을 평가해 보기로 했다. 본 비교실험을 통해 재현성이 우수할 경우 환자에 투여하는 방사선량을 줄인 동적신장검사법을 활용하고 환자의 피폭을 줄이고자 한다. 감마카메라 장비로는 Orbiter, SymbiaE (Siemens, Germany)를 사용하였고, 2013년 1월부터 2014년 2월까지 370 Mbq (10mCi)을 사용한 환자와 동일 환자 중 2014년 3월부터 2015년 7월까지 185 Mbq (5 mCi)을 사용한 환자를 대상으로 $^{99m}Tc-DTPA$사용 검사 21명과 $^{99m}Tc-MAG_3$사용 검사 20명 총 41명을 대상으로 데이터를 선별하였다. 결과 영상의 Renogram에서 Peak 지점의 프레임을 선택하여 신장의 관심영역과 배후방사능의 관심영역을 설정하고 K/B ratio를 구하여 비교하였다. $^{99m}Tc-DTPA$를 사용한 검사에서 370 Mbq을 사용하였을 때의 K/B ratio는 평균 $5.67{\pm}0.8$이었고, 185 Mbq을 사용하였을 때는 평균 $5.62{\pm}0.87$로 큰 차이를 보이지 않았다. $^{99m}Tc-MAG_3$를 사용한 검사에서도 신장/배후방사능 비는 370 Mbq을 사용 시 평균 $14.95{\pm}2.58$과 185 Mbq을 사용 시 평균 $14.56{\pm}2.02$로 큰 차이를 보이지 않았다. Paired sample t-test결과 p-value는 $^{99m}Tc-DTPA$ 0.566, $^{99m}Tc-MAG_3$ 0.363로 같은 비교집단 간 차이점이 없음을 확인하였다. 동일 환자를 대상으로 선량을 370 Mbq에서 185 Mbq로 줄였을 때의 동적신장검사의 재현성은 우수한 것으로 확인 되었다. 저선량 동적신장검사는 기존 감마카메라의 성능 개선 없이 재현성이 우수한 결과를 얻을 수 있고 환자의 피폭 또한 줄일 수 있을 것으로 사료된다.

  • PDF