• Title/Summary/Keyword: Terminal Value

Search Result 472, Processing Time 0.046 seconds

A Heuristic Solution for the Inventory Constrained Ship Routing for Multi-Commodity Bulk (복합화물의 재고를 고려한 선박 운송계획에 관한 발견적 해법)

  • Won, Suk-Hee;Hwang, Seung-June
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.4
    • /
    • pp.142-152
    • /
    • 2009
  • We developed two heuristic methods to solve the problem considering a fleet of ships delivering chemical products from terminals to terminals. We need to decide how much of each product to carry, on which ship, subject to the conditions that all terminals must have sufficient products to meet demand, and the stock levels of the products cannot exceed the inventory capacity of that terminal. Mathematical formulation and the optimal objective value for the small size problems are compared with two greedy heuristic methods developed in terms of solution qualities and computing time. Numerical experiments on test problems indicate that the heuristics are effective at finding good solutions quickly.

Direct Vector Control of Induction Motor with Compensator of Stator Resistance (고정자 저항 보상기를 갖는 유도전동기의 직접벡터제어)

  • Jeong, Jong-Jin;Lee, Deuk-Gi;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.10
    • /
    • pp.555-561
    • /
    • 1999
  • This paper proposes a new compensation algorithm for stator resistance that is crucial for improving the direct vector control performance of an induction motor. This algorithm is based on the flux estimator that is derived from the stator voltage equation. Since a flux estimator is dependent on the stator resistance, a flux error originates from the variation of the stator resistance. This parameter mismatch in the estimator thereafter affects the flux and torque response. Accordingly, a new compensator has been designed to offset this degradation in the responses. The proposed compensator is very simple to implement and does not require any modifications to the motor model or any special interruptions of the controller. The value of the stator resistance is attained in real time through measuring the terminal voltage and current. The effectiveness of the proposed scheme has been confirmed through both simulation and experimentation.

  • PDF

Examination of Loss Characteristics of Full-Bridge Electronic Ballast for HID Lamps (HID-lamp용 Full-Bridge 전자식 안정기의 손실 특성 규명)

  • Park, Jong-Yeon;Jung, Dong-Youl;Lee, Hyoek-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2537-2540
    • /
    • 2001
  • The purpose of this study is to examine the calculated method of loss characteristics of full-bridge eletronic ballast for 250Watt HID lamps by approximated modeling. These lamps have the most emit effiency and color rendering. Especially, the majority of losses appear to the MOSFET do full-bridge, L of output terminal and driver IC, besides losses occur to the R in the ballast. These losses cause heating and breakage of MOSFET. When HID-lamp arrivals the steady-state, loss of ballast is measured 9% and analyzed value is 8% approximately. Accordingly it is not too much to say that greater part of losses is examined.

  • PDF

Evaluation of Steelwork Continuity within Reinforced Concrete Apartment Structures (철근콘크리트 아파트의 철근구조체에 대한 전기적 연속성 평가)

  • Lee, Ki-Hong;Lee, Taek-Soeb;Kim, Oun-Seok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.125-127
    • /
    • 2005
  • This paper conducted to evaluate electrical continuity of steelworks within reinforced concrete apartment structures as the down conductor in external lightning protection system. The reinforcing bars in reinforced concrete structures can be used as the down conductor when their overall electrical resistance is not greater than the resistance value of 0.2 ohm between the uppermost part and the ground level. According to the results of electrical resistances measured by 4-terminal low resistance measurements, the steelworks in reinforced concretes structures exhibited the electrical continuity with low electrical resistance.

  • PDF

Analysis of On-Line Partial Discharge Trend in High Voltage Motors (고압전동기 운전중 부분방전 추이 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Chung-Hyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1472-1473
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) measurements were peformed with turbine generator analyzer(TGA) in two high voltage motors(rated 6.6 kV). These high voltage motors were installed with 80 pF capacitive couplers at the terminal box. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude (Qm). The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in stator windings of high voltage motors.

  • PDF

Sensorless Vector Control for PMSM Using Instantaneous Reactive Power (무효전력을 이용한 영구자석 동기전동기의 위치 및 속도 센서리스 제어)

  • Jin, Chang-Eon;Han, Yoon-Seok;Shin, Jae-Wha;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.384-386
    • /
    • 2000
  • This paper describes a new approach to estimating permanent magnet synchronous motor(PMSM) speed and position from measured terminal voltages and currents for speed-sensorless vector control. The proposed system is based on observing the instantaneous reactive power of the motor. The described technique is very simple and robust to variations of motor parameters. The new approach is not dependent upon the value of the stator resistance. Also, MRAS schemes are chosen for determining the adaptive law for the speed and the position estimator. The effectiveness is verified by the experimental results.

  • PDF

A Study on the Improvement of Electrode Installation for Measurement of Ground Resistance through Investigation on the Spot in Buildings (현장조사를 통한 건축물 접지저항 측정용 전극 설치의 개선에 관한 연구)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kil, Gyung-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.92-97
    • /
    • 2011
  • This paper deals with the improvement of electrode installation for measurement of ground resistance through investigation on the spot in buildings. The investigation was carried out for an earthing terminal board for measurement of ground resistance, installation of auxiliary electrode, etc. The criteria value is set up by measuring method of ground resistance in international standard. In case of inadequate installation of auxiliary electrode, a relative error is analyzed and adequate installation method of auxiliary electrode is proposed. As a consequence, it is necessary to write direction of ground and equipment, and separate auxiliary electrode for measurement of ground resistance in order to minimize measuring error.

Techniques to Diagnose Short-Circuit Faults in the Switching Mode Power Supply for Display (디스플레이용 스위칭모드 전원장치의 단락 고장분석 검출기법)

  • Lee, Jae-Won;Chun, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1186-1192
    • /
    • 2016
  • This paper proposes techniques to diagnose short-circuit faults of both the diodes and power FET in switching mode power supply (SMPS) by using a simple analog tester. The diodes in full-bridge rectifier, power FET, switching transformer, and some sensors are modelled with resistor. The total resistance value measured at the input terminal of a SMPS is analyzed when the short-circuit faults of diodes in a full bridge rectifier or power FET are occurred. The short-circuit faults of one or two diodes in a full bridge rectifier, power FET, and both the diodes in a full bridge rectifier and power FET can be detected by a range of total resistance, which is measured by the analog tester. Through experiments, the theoretical analysis for total resistance under short-circuit faults can be verified.

Decentralized Input-Output Feedback Linearizing Controller for MultiMachine Power Systems : Adaptive Neural-Net Control Approach

  • Park, Jang-Hyun;Jun, Jae-Choon;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.41.3-41
    • /
    • 2001
  • In this paper, we present a decentralized adaptive neural net(NN) controller for the transient stability and voltage regulation of a multimachine power system. First, an adaptively input-output linearizing controller using NN is designed to eliminate the nonlinearities and interactions between generators. Then, a robust control term which bounds terminal voltage to a neighborhood of the operating point within the desired value is introduced using only local information. In addition, we consider input saturation which exists in the SCR amplifier and prove that the stability of the overall closed-loop system is maintained regardless of the input saturation. The design procedure is tested on a two machine infinite bus power system.

  • PDF

ROBUST OPTIMAL PROPORTIONAL REINSURANCE AND INVESTMENT STRATEGY FOR AN INSURER WITH ORNSTEIN-UHLENBECK PROCESS

  • Ma, Jianjing;Wang, Guojing;Xing, Yongsheng
    • Bulletin of the Korean Mathematical Society
    • /
    • v.56 no.6
    • /
    • pp.1467-1483
    • /
    • 2019
  • This paper analyzes a robust optimal reinsurance and investment strategy for an Ambiguity-Averse Insurer (AAI), who worries about model misspecification and insists on seeking robust optimal strategies. The AAI's surplus process is assumed to follow a jump-diffusion model, and he is allowed to purchase proportional reinsurance or acquire new business, meanwhile invest his surplus in a risk-free asset and a risky-asset, whose price is described by an Ornstein-Uhlenbeck process. Under the criterion for maximizing the expected exponential utility of terminal wealth, robust optimal strategy and value function are derived by applying the stochastic dynamic programming approach. Serval numerical examples are given to illustrate the impact of model parameters on the robust optimal strategies and the loss utility function from ignoring the model uncertainty.