• Title/Summary/Keyword: Terfenol-D actuator

Search Result 21, Processing Time 0.026 seconds

A Study on Design and Characteristics of Linear Magnetostrictive Actuator Using Terfenol-D (Terfenol-D를 이용한 선형 자기변형 구동기의 설계 및 특성 연구)

  • 임채욱;정태영;문석준;김병현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.4
    • /
    • pp.308-316
    • /
    • 2003
  • Terfenol-D is one of magnetostrictive materials which have the property of converting the energy in magnetic fields into mechanical movement and vice versa. We designed and fabricated a linear magnetostrictive actuator using Terfenol-D. It has 25 mm diameter and 100 mm long. To grasp the characteristics of it, a series of tests were performed in the range of 50 Hz below. Induced-strain actuation displacements of the actuator measured by test and predicted by magnetic analysis agreed well. And blocked forces according to the input currents were estimated from the testing results. Modelling method representing the exerting force of a linear magnetostrictive actuator was confirmed through some testing results.

A Study on Design and Characteristics of Linear Magneto-strictive Actuator Using Terfenol-D (Terfenol-D를 이용한 선형 자기변형 구동기의 설계 및 특성 연구)

  • Lim, Chae-Wook;Chung, Tae-Young;Moon, Seok-Jun;Kim, Byung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.310.2-310
    • /
    • 2002
  • Terfenol-D is one of magnetostrictive materials which have the property of converting the energy in magnetic fields into mechanical movement and vice versa. We designed and fabricated a linear magnetostrictive actuator using Terfenol-D. It has 25mm diameter and 100mm long. To grasp the characteristics of it, a series of tests were performed in the range of 50㎐ below. Induced-strain actuation displacements of the actuator measured by test and predicted by magnetic analysis agreed well. (omitted)

  • PDF

Hysteresis Modeling and Control of Terfenol-D Actuator (Terfenol-D 액츄에이터의 히스테리시스 모델링과 제어)

  • Park, Y. W.;M. C. Lim;Kim, D. Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.660-663
    • /
    • 2003
  • This paper proposes a systematic approach for an accurate control of the Terfenol-D actuator taking into account hysteresis, modeled by applying the classical Preisach operator with memory curve. A desired input displacement is calculated by using the hysteresis inverter, which is fed into the actuator. Then the PI compensator corrects the error between the commanded and actual displacements. Experiments with the step responses show that the PI controller settles in 70 ms and the hybrid controller in 20 ms. It means that the concurrent application of two control schemes is effective to control the actuator.

  • PDF

A Study on Design and Characteristics of Linear Magnetostrictive Actuator Using Terfenol-D (Terfenol-D를 이용한 선형 자기변형 구동기의 설계 및 특성 연구)

  • Lim, Chae-Wook;Chung, Tae-Young;Moon, Seok-Jun;Kim, Byung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.17-24
    • /
    • 2002
  • Terfenol-D is one of magnetostrictive materials which have the property of converting the energy in magnetic fields into mechanical movement and vice versa. We designed and fabricated a linear magnetostrictive actuator using Terfenol-D. It has 25mm diameter and 100mm long. To grasp the characteristics of it, n series of tests were performed in the range of 50Hz below. Induced-strain actuation displacements of the actuator measured by test and predicted by magnetic analysis agreed well. And blocked forces according to the input currents were estimated from the testing results. Modelling method representing the exerting force of a linear magnetostrictive actuator was confirmed through some testing results.

  • PDF

High Precision Stepping Motor Using Terfenol-D Actuators: Its Performance Test (Terfenol-D 작동기를 이용한 초정밀 스텝모터의 성능평가)

  • 김재환;이현일
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.220-226
    • /
    • 2000
  • High precision step motor using Terfenol-D linear actuators is proposed and its performance is tested. Four Terfenol-D linear actuators are set up perpendicular to the rotor and saw-tooth current signals are applied on the actuators. It was found that the rotation angle is increased as the excitation current, the inertia of the rotor, and the contact force between the rotor and the push device are increased. The rotation angle per step of $0.001^{\circ}$ and blocking torque of 0.2Nm are achieved. The effect of the time delay between the excitation signals is also investigated.

  • PDF

Analysis and Design Actuator of Using Magnetostrictive Material (자기왜형 물질을 이용한 액츄에이터의 설계 및 특성해석)

  • Jang, S.M.;Cha, S.D.;Lim, C.U.;Jeong, T.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.751-753
    • /
    • 2001
  • The characteristic of magnetostrictive is to change shape in a magnetic field, TERFENOL-D is said to produce magnetostriction. A magneto strictive actuator need to the magnetic circuit. The most important design consideration is the magnetic circuit. The magnetic circuit consists of the solenoid coil, permanets for bias and shaping of the other parts through which the magnetic field passes. A good magnetic circuit ensures the proper magnetic field in th TERFENOL-D and very uniform magnetic field in all phases of the actuator operating cycle. This paper presents magnetic circuit design and analysis uesing FEM.

  • PDF

Development of Micro-size Search Coil Magnetometer for Magnetic Field Distribution Measurement

  • Ka, E.M.;Son, De-Rac
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.34-36
    • /
    • 2008
  • For the measurement of the magnetic field distribution with high spatial resolution and high accuracy, the magnetic field sensing probe must be non-magnetic, but the MFM probe and sub-millimeter-meter size Hall probe use a ferromagnetic tip and block, respectively, to increase the sensitivity. To overcome this drawback, we developed a micro-size search coil magnetometer which consists of a single turn search coil, Terfenol-D actuator, scanning system, and control software. To reduce the noise generated by the stray ac magnetic field of the actuator driving coil, we employed an even function $\lambda$-H magnetostriction curve and lock-in technique. Using the developed magnetometer, we were able to measure the magnetic field distribution with a magnetic field resolution of 1 mT and spatial resolution of $0.1mm{\times}0.2mm$ at a coil vibration frequency of 1.8 kHz.

A Study on a Laser Scanning Vibrometer Using a Magnetostrictive Resonant Device (자기 변형 공진 기구를 이용한 레이저 스캐닝 진동측정기에 관한 연구)

  • 이정화;류제길;박기환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.58-66
    • /
    • 1998
  • A low power consuming laser scanning vibrometer is studied for its development. For its optical system, a laser interferometer is constructed to use the Doppler effect. In order to reduce the driving power of the scanning system, a small displacement of the scanning system is produced, which is achieved by using a magnetostrictive actuator. A sufficient rotating angle of the scanning system is obtained by using an amplified displacement from the resonant phenomena of a second order mechanical system composed of a mass and spring. The control of the magnetostrictive actuator using a Terfenol-D is performed without using a feedback system to help reduce the power consumption. The vibration analysis is made for the sinusoidal scanning input to have the space domain information from the time domain of the velocity of a vibration object. As a partial work of development of a tow power consuming laser scanning vibrometer, in this work, a scanning system which has the above features is developed and experimentally investigated. For the purpose of the optical system calibration, the vibration measurement for one axis is presented and the future works are discussed.

  • PDF