• 제목/요약/키워드: Tensor permeability

검색결과 19건 처리시간 0.025초

회전 자계에 의한 철손의 유한요소 해석 (Calculation of Iron Loss under Rotational Magnetic Field Using Finite Element Method)

  • 이학용;박관수;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.147-149
    • /
    • 1994
  • In designing high efficiency electrical machines, calculation of iron loss is very important. And it is reported that in the induction motor and in the T-joint of 3 phase transformer, there occurred rotational magnetic field and much iron loss is generated owing to this field. In this paper, rotational power loss in the electrical machine under rotational magnetic field is discussed. Until now, loss analysis is based on the magnetic properties under alternating field. And with this one dimensional magnetic propertis, it is difficult to express iron loss under rotational field. In this paper, we used two dimensional magnetic property data for the numerical calculation of rotational power loss. We used finite element method for calculation and the analysis model is two dimensional magnetic property measurement system. We used permeability tensor instead of scalar permeability to present two dimensional magnetic properties. And in this case, we cannot uniquely define energy functional because of the asymmetry of the permeability tensor, so Galerkin method is used for finite element analysis.

  • PDF

A Computationally Efficient Finite Element Analysis Algorithm Considering 2-D Magnetic Properties of Electrical Steel Sheet

  • Yao, Yingying;Li, Wei;Yoon, Hee-Sung;Fujiwara, Koji;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.385-390
    • /
    • 2008
  • For taking account of the two-dimensional magnetic properties of a grain-oriented electrical steel sheet, the effective anisotropic tensor reluctivity is examined, and a computationally efficient algorithm is suggested by using the response surface method to model the two-dimensional magnetic properties. It is shown that the reconstructed two-dimensional magnetic properties are fairly effective to stabilize the convergence characteristics of the Newton-Raphson iteration in the nonlinear magnetic field analysis.

3차원 균열연결망 모델에서의 유효투수계수 평가 및 터널굴착 지하수 유동해석에 대한 수치실험 (Numerical Experiments on the Evaluation of Effective Permeability and Tunnel Excavation in the Three Dimensional Fracture Network Model)

  • 장근무
    • 터널과지하공간
    • /
    • 제8권4호
    • /
    • pp.275-286
    • /
    • 1998
  • 균열연결망 모델에서의 투수계수 텐서, 주 투수계수 그리고 주 투수계수 방향들에 대한 인자에 근거해서 유효투수계수와 대표요소체적을 구하였다. 전체브록에 대한 소블록의 투수계수의 계산을 통해서 유효투수계수는 조화평균과 산술평균 사이의 범위임을 알 수 있었다. 정육면체 모델에서 체적의 증가에 따른 유량의 변화계산에 대한 수치실험으로부터 유량의 변화는 모델의 체적이 대표요소체적에 접근함에 따라 감소함을 보여 주어ST다. 터널로의 지하수 유입량은 대표요소체적 개념보다는 터널길이대 모델크기의 비에 더 큰 영향을 받는다고 볼 수 있다. 그리고 균열연결망 모델과 등가다공성 모델에서의 지하수 유입량은 정확히 일치하지 않았으며 특히 모델크기에 대한 터널길이가 작을수록 그 차이가 크게 발생하였다.

  • PDF

Cu/Ni80Fe20 코어/쉘 복합 와이어에서 대각(Diagnonal) 자기임피던스 (Diagonal Magneto-impedance in Cu/Ni80Fe20 Core-Shell Composite Wire)

  • 조성언;구태준;김동영;윤석수;이상훈
    • 한국자기학회지
    • /
    • 제25권4호
    • /
    • pp.129-137
    • /
    • 2015
  • Cu(반경 $r_a$ = $95{\mu}m$)/$Ni_{80}Fe_{20}$(외경 $r_b$ = $120{\mu}m$)의 코어/쉘 복합 와이어를 전기도금방법으로 제작하였다. 제작 된 복합 와이어에 대해 원통 좌표계에서 임피던스 텐서의 두 대각 성분 $Z_{{\theta}{\theta}}$$Z_{zz}$를 10 kHz~10 MHz 범위의 주파수(f)와 0 Oe~200 Oe 범위의 외부 정지 자기장의 함수로 측정하였다. Maxwell 방정식으로부터 코어/쉘 복합 와이어의 두 대각 임피던스 $Z_{{\theta}{\theta}}$$Z_{zz}$를 각각 복소 투자율 텐서의 두 대각 성분 ${\mu}^*_{zz}$${\mu}^*_{{\theta}{\theta}}$로 표현하는 식을 유도하였다. 유도된 식을 이용하여 측정된 $Z_{{\theta}{\theta}}$(f)와 $Z_{zz}$(f) 스펙트럼으로부터 ${\mu}^*_{zz}$(f)와 ${\mu}^*_{{\theta}{\theta}}$(f) 스펙트럼을 각각 뽑아낼 수 있었다. 뽑아낸 두 대각 투자율 스펙트럼을 자벽이동과 자화회전의 완화과정으로 해석하면 Cu/NiFe 코어/쉘 복합 와이어의 동적 자화과정을 규명하는 유용한 도구가 될 수 있다는 것을 제시하였다.

브레이드 프리폼의 투과율 계수 예측 (Prediction of Permeability for braided preform)

  • Song, Young-Seok;Youn, Jae-Roun
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.191-194
    • /
    • 2003
  • In this study, permeability tensor is computed for a three dimensional braided preform by applying a FVM to a unit cell. It is evident that resin will flow through the inter-tow and the intra-tow regions when pressure gradient is applied to the resin. The intra-tow region in the braided preform is regarded as not only an impermeable solid but also a permeable porous media. When the intra-tow region is excluded from domain of flow analysis in the case of the impermeable solid, the Stokes equation is computer for only inter-tow region. (omitted)

  • PDF

다층 예비성형체에 대한 삼차원 충진해석 (Three-Dimensional Mold Filling Simulation for Multi-layered Preform in Resin Transfer Molding)

  • 양매;송영석;윤재륜
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.137-140
    • /
    • 2005
  • Resin transfer molding (RTM) is one of the most popular processes for producing fiber reinforced polymer composites. In the manufacture of complex thick composite structures, analysis on flow front advancement on the resin impregnating the multi-layered fiber preform is helpful for the optimization of the process. In this study, three-dimensional mold filling simulation of RTM is carried out by using CVFEM (Control Volume Finite Element Method). On the assumption of isothermal flow of Newtonian fluid, Darcy’s law and continuity equation are used as governing equations. Different permeability tensors employed in each layer are obtained by experiments. Numerically predicted flow front is compared with experimental one in order to validate the numerical results. Flow simulations are conducted in the two mold geometries, rectangular plate and hollow cylinder. Permeability tensor of each layer preform in Cartesian coordinate system is transformed to cylinder coordinates system so that the flow within the multi-layered preforms of the hollow cylinder can be calculated exactly. Our emphasis is on the three dimensional flow analysis for circular three-dimensional braided preform, which shows outstanding mechanical properties such as high impact strength and toughness compared with other conventional two-dimensional laminar-structured preforms.

  • PDF

도파관 래칭 이상기의 고차 모드 해석 (Analysis of Higher Order Modes of Waveguide Latching Phase Shifter)

  • 신동만;윤상원;박동철
    • 대한전자공학회논문지
    • /
    • 제26권8호
    • /
    • pp.1145-1151
    • /
    • 1989
  • New method to calculate the characteristics of the dominant and higher order modes of waveguide latching phase shifters are presented. Due to the tensor permeability, E and H fields inside the ferrite are expanded in terms of the LSE and LSM eigenmodes of the dielectric-slab-loaded waveguide. The equivalent coupled transmission line equations on the transverse plane are derived to obtain the dispersion characteristics and the E and H field distributions. Numerical results at X-band are compared with those published previously. The derived field distributions can be used to suppress the higher order modes of the latching phase shifters, so that the phase shift from the dominant mode only contributes the performance of the phase shifters.

  • PDF

머시영역의 비등방성을 고려한 2성분혼합물의 응고과정 (Solidification Process of a Binary Mixture with Anisotropy of the Mushy Region)

  • 유호선
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.162-171
    • /
    • 1993
  • 본 연구에서는 2성분혼합물의 응고과정해석에 머시영역의 비등방성을 포함시 킬수 있는 모델을 정립하고 실제계산을 수행하여 비등방성이 천이현상 및 조대편석(m- acrosegregation)에 미치는 영향을 보이고자 한다. 이 과정에서 기본 방정식의 변형 을 통한 수치해석의 효율화에 관해서도 취급할 것이다. 해석대상은 비등방성의 효과 가 잘 나타날 수 있으면서 해석은 용이한 2차원 정사각형용기로 선택하였다. 대상혼 합물은 실용적으로 관심있는 금속 합금과 결정구조가 유사하며 물성치가 비교적 잘 확 립된 염화암모늄수용액(NH$_{4}$C1-H$_{2}$O)이다. 특히 아공정염화암모늄수용액은 부력비(buoyancy factor)가 -1.4정도로서 온도와 농도구배에 의한 부력이 크기는 비슷 하지만 작용방향이 반대이기 때문에 이중확산대류의 전형적인 형태를 고찰하기에 편리 한 물질이다.

자기 이방성 응력측정법을 활용한 터널 지보 구조물의 비파괴계측에 관한 기초적 연구 (Preliminary Study for Non-destructive Measurement of Stress Tensor on H-beam in Tunnel Support System using a Magnetic Anisotropy Sensor)

  • 이재호;아쿠타가와 신니치;김영수;김광일;정일한
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.766-777
    • /
    • 2008
  • Currently in increasing number of urban tunnels with small overburden are excavated according to the principle of the New Austrian Tunneling Method (NATM). Successful design, construction and maintenance of NATM tunnel demands prediction, control and monitoring of ground displacement and support stress high accuracy. A magnetic anisotropy sensor is used for nondestructive measurement of stress on surfaces of a ferromagnetic material, such as steel. The sensor is built on the principle of the magneto-strictive effect in which changes in magnetic permeability due to deformation of a ferromagnetic material is measured in a nondestructive manner, which then can be translated into the absolute values of stresses existing on the surface of the material. This technique was applied to measure stresses of H-beams, used as tunnel support structures, to confirm expected measurement accuracy with reading error of about 10 to 20 MPa, which was confirmed by monitoring strains released during cutting tests The results show that this method could be one of the promising technologies for non-destructive stress measurement for safe construction and maintenance of underground rock structures encountered in civil and mining engineering.

  • PDF