• Title/Summary/Keyword: Tensioning device

Search Result 21, Processing Time 0.022 seconds

A Study on Performance Diagnosis of the Pulley Type Automatic Tensioning Device and Improvement of Maintenance (활차식 자동장력조정장치 성능진단 및 유지보수 개선에 관한 연구)

  • Park, Hyun;Lho, Young Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1103-1107
    • /
    • 2016
  • The automatic tensioning device of the catenary system constantly maintains the tension of the trolley wire by absorbing the variations due to the elasticity of the line caused by temperature variation. The tension plays an important role in affecting the electric motorcar operation directly. This paper suggests the methodology of the life cycle extension and the maintenance of the automatic tensioning device by means of performance diagnosis of the pulley type automatic tensioning device which has been commonly used for the electric railway system. Through conducting performance diagnosis and comparative test for the wornout pulley type automatic tensioning device by replacing the components such as the bearing and the bearing shaft without replacing all the assembly, the tensioning device is analyzed whether it is properly functioned. Provided that the maintenance regulation is reinforced so as to implement the bearing replacement through periodical precise inspection along with random check-up inspection which is now carried out by the operating organizations, it is ensured that the life cycle extension and the reduction of maintenance cost of the tensioning device could be achieved.

Development and Evaluation of a Spring Type Tensioning Device for Korea Railroad (한국형 스프링식 장력 장치의 개발 및 평가)

  • Yoon Yong-Han;Yim Geum-Kwang
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.765-770
    • /
    • 2005
  • This paper presents a development and evaluation of a spring type tensioning device for Korea railroad. The wheel type tensioning device used in the Korea railroad requires much time and labor for maintenance including wire replacement and oil application. So, we found it necessary to develop a new type of maintenance-free tensioning device. In this paper, we introduced a spring type tensioning device for Korea railroad.

  • PDF

Field Test Results of a Spring Type Tensioning Device for Korea Railroad (한국형 스프링식 장력 장치의 현장 시험 결과)

  • Yoon Yong-Han;Yim Geum-Kwang
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.771-776
    • /
    • 2005
  • This paper presents field test results of a spring type tensioning device for Korea railroad. The wheel type tensioning device used in the Korea railroad requires much time and labor for maintenance including wire replacement and oil application. So, we found it necessary to develop a new type of maintenance-free tensioning device. In this paper, we introduced field test results of spring type tensioning devices for Korea railroad.

  • PDF

A Development of Pulley-type Tensioning Device for a High Speed Railway (고속용 풀리형식 장력조정장치 개발)

  • Cho, Yong-Hyeon;Kwon, Sam-Young;Park, Young;Lee, Ki-Won
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.723-730
    • /
    • 2006
  • In the electrical railway, the tension ascension of contact wire is essential to speed up of train and current collection performance of catenary largely depends on the tension. The tension variation rate of the tensioning device used in existing line limits within 5%, and the tension variation rate of the spring-type tensioning device installed at the section where tensioning length is short bounds within 15%. So it is urgent for us to localize it for high speed line, which the tension variation rate is limited within 3%. Therefore in this study, a pulley-type tensioning device for high speed line is developed. To verify the performance of developed device, a performance test, overload test and failure test is carried out under the code of the Kyung-Bu High Speed line. And it is secured durability performance through a fatigue test.

  • PDF

Development of a Tensioning Device for the 400km/h High-speed Overhead Contact Line (400km/h급 전차선로용 장력조정장치 개발)

  • Cho, Yong Hyeon;Lee, Kiwon;Kwon, Sam Young;Cho, Ho Rung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1789-1795
    • /
    • 2015
  • The pulley-type tensioning device subjected to a maximum tension of 34 kN has been developed for 400 km/h high-speed railway. The tensioning device is to maintain the tension variation within 3% of the normal value, irregardless of temperature changes. Field tests shows that the tensioning device had a variation of tension which was as small as 0.6% as temperatures changed from $-5{\sim}7^{\circ}C$. Along with the tensions, we measured its X and Y movements due to the temperature changes. Based on a combination of its X and Y movements, we proposed a new performance index with which we can see if the tensioning device has troubles in operation without tension measurements.

Development of a Pulley-type Tensioning Device (도르래식 장력조정장치 개발)

  • Lee, Ki-Won;Cho, Yong-Hyeon;Park, Young
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.663-669
    • /
    • 2009
  • In the electrical railway, the increase of tensions in an overhead contact lines is essential to speed-up of train, because current collection quality largely depends on the ratio of a wave propagation speed to a train speed. For Kyungbu high-speed line, a pulley-type tensioning device is required to have a tension variation of maximum 3%. Therefore we developed a pulley-type tensioning device in order to meet tension variation requirement of the high-speed tensioning device. To verify the performance of the developed device, a performance test, overload test and failure test were carried out according to the factory test procedure of the Kyung-Bu High-speed line. Furthermore, we also performed reliability performance through not only a fatigue test in a factory, but also on-line verification test in Chungbuk line for over 1 year. These tests verified that the tensioning device had applicability to a main line.

An Analysis of the Spring Type Automatic Tensioning Device Outworn Change (스프링식자동장력조정장치 노후변화 분석)

  • Oh, Wan-Shik;Seo, Ki-Bum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.214-218
    • /
    • 2016
  • Catenary maintains the tension of the catenary using automatic tensioning devices to meet performance require m ents exhibited by the house is generated in accordance with the new external temperature changes. Double spring type autom a tic tensioning device is permanent and does not require the usual maintenance, and a deterioration due to no recognizable ab normalities characteristic of the nature of the internal state has the disadvantage that can not be confirmed. The disassembled for automatic spring-tension capabilities ensure efficient operation and life expectancy of the adjustment device via a check by analyzing the changes in old age determine the remaining lifetime is expected to be available as a basis for maintenance in the future.

A Study on The Expansion and Contraction in Accordance with Temperature Change of Contact Wire and Messenger Wire (온도 변화에 따른 전차선 및 조가선의 신축에 관한 연구)

  • Yoon, Yong-Han;Yim, Geum-Kwang
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.587-592
    • /
    • 2006
  • This paper presents expansion and contraction in accordance with temperature change of contact wire and messenger wire. The tensioning device is designed and installed to pull the contact wire and messenger wire straight at all times. Pulling a contract wire straight ensures that smooth contract is maintained between the contact wire and pantograph of an electric train, and this makes it possible to ensure a stable supply of electricity to the train. Normally, tensioning devices are installed at two positions over a distance of 1.0[km] to 1.6[km] per line. In installing the tensioning device, therefore, it is necessary to study the stroke(the range of the extension/contraction rate of the tensioning device compatible with that of the contact wire and messenger wire due to change in temperature). This paper introduces and discusses this topic.

  • PDF

A Study on the Behavior Characteristics of a Tensioning Device of a Catenary System According to the Longitudinal Dynamic Displacement of Railroad Bridge (철도교량의 종방향 동적 변위에 따른 전차선로 장력조정장치 거동특성에 관한 연구)

  • Na, Youn-Il;Lee, Jae-Bong;Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1517-1522
    • /
    • 2015
  • Since electric railroad vehicle pass through repeatedly on the railroad bridge, the dynamic load that causes the change of tension of contact wire affect it constantly. In this paper, we measured the dynamic displacement of the railroad bridges to analyze the effect of tension in the catenary. A result of dynamic measurement of the longitudinal displacement, it's maximum value was 39.9mm which was lower than the primary management criteria 378mm. Also on the based of a maximum temperature, it shows a feature that the longitudinal displacement value increased as temperature rise from April to October. In terms of behavior characteristics of a tensioning device, it was confirmed to be the value of 50mm stroke movement when the temperature changes ±5℃.

Examples of Trolley Wire Resistance Influential on The Movement of Tensioning Devices (장력조정장치의 동작에 영향을 미치는 가선저항의 사례)

  • Yoon, Yong-Han;Yim, Geum-Kwang;Han, Yang-Gyu
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.886-892
    • /
    • 2007
  • This paper presents examples of trolley wire resistance influential on the movement of tensioning devices. Therefore, this study is on the examples of trolley wire resistance which keep tensioning devices from working properly to the expansion and contraction in accordance with temperature change of overhead trolley wire system such as messenger wire and contact wire. Trolley wire resistance interrupts the working of tensioning device and drops the capacity of trolley wire. Reduced trolley wire capacity lowers the performance of current collection and has a bad effect on electrical train operation. So it is desirable to reduce the factors increasing trolley wire resistance to the minimum from the designing and construction stage of overhead trolley wire system. This study will introduce this problem and suggest the solution.

  • PDF