• Title/Summary/Keyword: Tensional strength

Search Result 15, Processing Time 0.026 seconds

An Experimental Study of the King Sejong Station and Siberian Frozen Soils (세종기지 및 시베리아 흙의 동결특성 시험)

  • Kim, Youngchin;Shin, Jaewon;Son, Seungmo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.5-12
    • /
    • 2009
  • Soil samples from the King Sejong Station in Antarctic and Vladivostok were tested in the laboratory and specific gravity, compaction curve, grain size distribution were determined. The effect of temperature change on the thermal conductivity, unfrozen water content, compressive strength were investigated. In addition, the change of tensile strength with temperature of the soil from Vladivostok was measured. Samples for the compressive strength test and tensional strength test were prepared in a mould with a fixed volume to prevent swelling. Also the effects of temperature and water content change on those strength were compared. Results from the thermal conductivity test showed that thermal conductivity values for both soils was larger at temperatures below freezing than those above freezing. The unfrozen water content dropped rapidly within a temperature range of $0{\sim}-5^{\circ}C$ and then gradually decreased further $-20^{\circ}C$. Compressive strength test results showed various stress/deformation curves with a change in water content. Sandy soil of the King Sejong Station had a much larger strength than ice at an identical temperature, while clayey soil of Vladivostok had a smaller strength than ice in the initial stage, but showed a larger strength at temperatures belows $-15^{\circ}C$. Tensile strength tests revealed an increase in the strength with a decreasing temperature.

  • PDF

Behavior under repeated loads of beam partially superseded with steel fiber reinforced concrete in tension part (인장부에 강섬유 보강 콘크리트가 부분적으로 대체된 보의 반복하중 거동)

  • Park, Tae-Hyo;Park, Jae-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.437-440
    • /
    • 2004
  • In this study, dual composites concrete beam(DCC beam) partially superseded with steel fiber reinforced concrete in tensional part and normal strength concrete in compressive and remaining part is proposed. Based on flexural test under static loads, structural behaviors under repeated loads are investigated.

  • PDF

Theory and Practice in the Tensile Strength Test for Split Ring Shaped Rock Specimen (터진고리 형태의 암석시편에 대한 인장강도 시험의 이론과 실제)

  • Choi, Byung-Hee;Lee, Youn-Kyou;Park, Chan;Park, Chulwhan
    • Explosives and Blasting
    • /
    • v.38 no.1
    • /
    • pp.30-37
    • /
    • 2020
  • In this study the split ring (SR) test was investigated for its applicability to the measurement of the tensile strength of rock specimen of NX size. The concept of the SR test is the same as the half ring (HR) test (Choi et al., 2019) except that the expected fracture plane is perpendicular to the loading direction. Because of this perpendicularity, however, it was believed that the SR test could be more accurate than the HR test. Like the HR specimen, the SR specimen is a curved prismatic bar with a uniform section. Appealing to a basic bending theory in strength of materials, the tensile strength for the special bar can be calculated analytically. Numerical simulations using LS-DYNA revealed, as expected, that the strength errors were 1% and 5% for the tensional and compressional SR tests, respectively, which were much lower than that (12%) of the HR test. To identify the performance of the two SR tests, laboratory experiments were conducted. The HR and Brazilian tests were also performed for comparison. The experiments showed that the ratios of the tensional and compressional SR to Brazilian strengths were 1.2~1.4 and 1.1~1.2, respectively, which are too small compared to empirical values in ordinary bend tests. Consequently, it is concluded that the SR test is not appropriate for use in tensile strength test of rock specimen of NX size. But the ratio of the HR to Brazilian strengths was within 1.7~2.0 for both the previous and present studies, showing a good consistency in their test results.

The statistical two-order and two-scale method for predicting the mechanics parameters of core-shell particle-filled polymer composites

  • Han, Fei;Cui, Junzhi;Yu, Yan
    • Interaction and multiscale mechanics
    • /
    • v.1 no.2
    • /
    • pp.231-250
    • /
    • 2008
  • The statistical two-order and two-scale method is developed for predicting the mechanics parameters, such as stiffness and strength of core-shell particle-filled polymer composites. The representation and simulation on meso-configuration of random particle-filled polymers are stated. And the major statistical two-order and two-scale analysis formulation is briefly given. The two-order and two-scale expressions for the strains and stresses of conventionally strength experimental components, including the tensional or compressive column, the twist bar and the bending beam, are developed by means of their classical solutions with orthogonal-anisotropic coefficients. Then a new effective mesh generation algorithm is presented. The mechanics parameters of core-shell particle-filled polymer composites, including the expected stiffness parameters, minimum stiffness parameters, and the expected elasticity limit strength and the minimum elasticity limit strength, are defined by means of the stiffness coefficients and elasticity strength criterions for core, shell and matrix. Finally, the numerical results for predicting both stiffness and elasticity limit strength parameters are compared with the experimental data.

Analytical Study on Ultimate Design Method of Tube Flange Joints with the Rib Plate Using the High Strength Bolt (리브 붙은 고력볼트 강관플랜지 이음의 극한 설계방법에 관한 해석적 연구)

  • Kim, Seong Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.537-547
    • /
    • 2000
  • The tube flange joint often used in the field is a kind of tensional joint method using the high strength bolts. Transferring stress is conducted by high axial pressure between each part of material that is produced by twisting the high strength bolts. And historical characteristics of the flange joint have not been studied sufficiently and it is difficult to say that the design method is established definitely. Therefore new method using ultimate strength is need to be suggested to solve there problems in using flange joint. The purposes in this study are to gain the data base for establishing design method of joint in the form like figure1 and survey whether the joint of tube flange with non-equal diameter can be designed or not in the form like rib or ring.

  • PDF

Mechanical characteristics of class-F groundwall insulation tapes for stator windings (고정자 권선용 F종 주절연테이프의 기계적 특성)

  • Kim, Tae-Hee;Kang, Myung-Guk;Lee, Jai-Kwun;Son, Sam-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1676-1678
    • /
    • 2004
  • Class-F resin-rich type insulating tapes are generally used for the groundwall insulations of the large turbine generators with air-cooled and hydrogen-cooled stator windings. In this paper, mechanical strength properties degraded over aging time in higher temperature than designed one in normal condition were experimentally investigated and the results of comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich insulating tapes with composite material of Mica/Epoxy/support currently were used in this test. The tests for tensile and flexural strength properties were conducted with the specimens which were composed of unaged and the aged specimens accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The tensional strength was only measured for the unaged specimens and the results are also presented to make a comparative test for their initial mechanical characteristics.

  • PDF

The Strength Characteristics of PVA Fiber Reinforced CSG Materials (PVA섬유 보강 CSG 재료의 강도특성)

  • Jin, Guang-Ri;Kim, Ki-Young;Quan, He-Chun;Kim, Kyu-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.12
    • /
    • pp.95-104
    • /
    • 2013
  • Recently, application of CSG is increasing in various design construction projects. At the initial stage of cementation CSG materials show the same mechanical characteristics as soil, however, as the cementation process develops, CSG materials gradually reveal material characteristics of concrete. The hardened CSG manifests elastic behavior such as maximum strength at small strain range and rapid brittle failure. In this research, PVA fiber stiffeners were used in order to: (1) reduce such brittle behavioral characteristics; (2) improve the relatively weak tension performance of CSG materials. The binding strength between the bed materials and fiber prevents rapid brittle failure and increases tensional strength of fiber reinforced CSG materials.Test results show that fiber reinforcement alone could induce the stress-strain characteristics of CSG materials from brittle failure to ductile failure and also increase the residual strength.

Analysis of Breaking Accident of FRP Insulator Rod installed in Dead Section (절연구간 조가선 FRP 절연봉의 절단사고 원인분석)

  • Jang, Don-Guk;Lee, Ki-Won;Kim, Ju-Rak;Park, Hyun-June
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.502-505
    • /
    • 2003
  • The accidnet of breaking insulator rod leads to inturruption of moving the subway. We investigate the analysis of analysis of breaking accident of FRP insulator rod installed in dead section for catenary feeding system. To analysis of accident reason, SEM is used to analysis microscopic struture on surface of cross section of broken FRP insulator rod. At the same time, we examine the chage of atomic amount on solace of accident insulator through EDX analysis. Also, the test for tensional breaking load is condoled to check the mechanical strength.

  • PDF

Fatigue Life Evaluation on Compressive & Tensional Residual Stress Induced Materials and Residual Stress Measurement using Hole Drilling Method (HDM을 이용한 잔류응력측정과 압축·인장 잔류응력이 인가된 재료의 피로수명평가)

  • Baek, Seung Yeb
    • Journal of Welding and Joining
    • /
    • v.31 no.2
    • /
    • pp.43-48
    • /
    • 2013
  • This paper Investigated the characteristics of residual stress in weld is composed of typical specimens, are investigated by using three dimensional thermal elasto-plastic FEM analysis. Numerically calculated residual stresses in the gas welds were then compared with experimental results obtained by the hole-drilling method. Using the stress amplitude (${\sigma}a$)R at the hot spot point of gas weld, the relations obtained as the fatigue test results for typical specimens having various dimensions and shapes were systematically rearranged to obtain the (${\sigma}a$)R-Nf relationship. It was found that more systematic and accurate evaluation of the fatigue strength of plug- and ring-type gas-welded joints can be achieved by using (${\sigma}a$)R.

Evaluation of Strength and Residual Stress in $Si_3N_4/SUS304$ Joint ($Si_3N_4/SUS304$ 접합재의 잔류응력 및 강도평가)

  • 박영철;오세욱;조용배
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.101-112
    • /
    • 1994
  • The measurement of residual stress distribution of $Si_3N_4/SUS304$ joint was performed on 23 specimens with the same joint condition using PSPC type X-ray stress measurement system and the two-dimensional elastoplastic analysis using finite element method was also attempted. As results, residual stress distribution near the interface on the ceramic side of the joint was revealed quantitatively. Residual stress on the ceramic side of the joint was turned out to be tensional near the interface, maximum along the edge, varying in accordance with the condition of the joint and variance to be most conspicuous for the residual stress normal to the interface characterized by the stress singularities. In the vicinity of the interface, the high stress concentration occurs and residual stress distributes three-dimensionally. Therefore, the measured stress distribution differed remarkably from the result of the two-dimensional finite-element analysis. Especially at the center of the specimen near the interface, the residual stress, $\sigma_{x}$ obtained from the finite element analysis was compressive, whereas measurement using X-ray yielded tensile $\sigma_{x}$. Here we discuss two dimensional superposition model the discrepancy between the results from the two dimensional finite element analysis and X-ray measurement.