• Title/Summary/Keyword: Tension range

Search Result 437, Processing Time 0.023 seconds

Estimation of Long Term Clamping Force of High Strength Bolts By Coating Thickness Parameters of Slip Faying Surfaces (미끄럼 표면 도막두께변수에 따른 고력볼트 장기축력 예측)

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Ryoo, Jae-Yong;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.1
    • /
    • pp.8-15
    • /
    • 2012
  • The initial clamping forces of high strength bolts depending on different faying surface conditions drop within 1,000 hours regardless of loading, any other external force or loosening of the nut. This study is focused on an expectation model for relaxation of high strength bolt, which is confined to creep on coated faying surfaces after initial clamping. The range of this experiment is limited to estimate the relaxation of bolted joints coated by inorganic zinc primer. The candidate bolts were dacro-coated tension control bolts. The parameters of coated thickness for the faying surface were 96, 168,and $226{\mu}m$ respectively. From experiments, it exhibited that the logarithmic function for creep strain was derived due to the parameter of coating thickness. By using the creep strain, subsequently the quantitative model for estimating long term relaxation of high strength bolt can be taken with the elapsed time. The experimental results showed that the relaxation after the initial clamping of high strength bolt rose to a much higher range from 10% to 18% due to creep of the coating as the coating thickness was increased. This study showed that the clamping force reflecting relaxation after the elapse of constant time can be calculated from the initial clamping force of high strength bolt.

Pull-out repair for root tear of medial meniscus (내측 반월상 연골 후방 골 기시부 파열의 수술적 봉합술)

  • Kim, Deok-Weon;Moon, Jeong-Seok;Kim, Min-Gun;Kim, Jin-Goo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Purpose: This study is to evaluate the clinical findings of media] meniscus root tear, pull-out repair technique and it's short term results. Materials and Methods: From September 2003 to August 2004, 23 cases of total 27 medial meniscus root tears were treated by pull-out repair technique. Mean age was 60.2 years old. The pull-out technique was divided into 2 groups In group 1(14/23 cases), anterolateral portal was used and in group 2(9/23 cases), anterolateral and posteromedial portals were used for bed preparation. Concomitant cartilage lesions were documented as ICRS mapping system. The clinical outcomes were evaluated according to Lysholm Knee Score. Results: The postoperative Lysholm Knee Score was 77.1(range; $58{\sim}97$) in group 1 and 81.4(range; $72{\sim}94$) (p>0.05). The failure rate was 3 of 14 cases(21.4%) in group 1 and 1 of 9 cases(11.1%) in group 2. Twenty of 22 cases(90.9%) showed cartilage lesions in weight bearing portion of medial femoral condyle which were 8 grade III and 5 grade IV according to the Outerbridge classification. Conclusion: Pull-out repair seems to be a useful treatment of the medial meniscus root tear for preservation of circumferential hoop tension of meniscus.

  • PDF

Effect of Cosurfactant on Intermediate Phase Formation in Systems Containing Alkyl Ethoxylate Nonionic Surfactant, Water and Lubricant (Alkyl Ethoxylate 비이온 계면활성제, 물과 윤활유를 포함한 시스템에서 보조계면활성제가 중간상 생성에 미치는 영향에 관한 연구)

  • Lim, Jong Choo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.778-784
    • /
    • 2005
  • It has been found that the addition of cosurfactant is necessary in order to expand three phase region containing middle phase microemulsion in ternary systems containing alkyl ethoxylate (AEO) nonionic surfactant, commercial lubricant and water. Phase behavior in the surfactant systems with addition of cosurfactant over a temperature range of 30 to $60^{\circ}C$ showed different trends depending on surfactant, temperature and chain length of alcohol added. For the $C_{12}E_4$ system, addition of n-pentanol and n-hexanol both produced a three phase region over a wide range of temperatures but the middle-phase formed was found to be a $L_3$ or D' phase which would not facilitate solubilization of high molecular weight lubricants. On the other hand, for the $C_{12}E_5$ system, the middle-phase microemulsion was found to be formed with addition of a rather long-chain alcohol such as n-hexanol, n-heptanol, n-octanol, or n-nonanol. The results shown with the addition of cosurfactant was understood in connection with interfacial tension measurements and composition analysis. The inability of the hydrocarbon region of the surfactant films to incorporate the large lubricant molecules and high solubility of a hydrophobic surfactant are thought to be the chief reasons for poor solubilization with D' phase.

Study on Fatigue Behavior and Rehabilitation of Stringer with Coped Section(I) -Experimental Study on Static and Fatigue Behavior- (절취부를 갖는 세로보의 피로거동과 보수·보강에 관한 연구(I) -정적거동 및 피로거동의 실험적 고찰-)

  • Hwang, Yoon Koog;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.363-375
    • /
    • 1997
  • This study encompasses the performance of static and fatigue test for the 8 large scale test specimens to clarify the fatigue behavior of coped stringer and the effect of the repair and strengthening on the damaged stringer of the floor system in steel railway bridges. For the purpose of the research, the actual stress wave for the existing bridge was measured, the basic stress range frequency histogram was made and the equivalent stress range was calculated. Using the result from the equivalent stress range made by adjusting the stress range, the static and fatigue test was carried out by identifying the previous rehabilitation and after. As the result of the static tests, it was revealed that the level of local stress under the S1 specimen test of the real equivalent stress range was similar to tensile strength of the test material, and it was consistent with the requirement of the initiation condition of the fatigue crack. Through the various rehabilitation methods to the damaged specimens, the effects of the repair and reinforcement were analyzed. According to the results of the repair of effect, bolting the high tension bolt over the stop hole was confirmed to be more adequate method than drilling only stop hole to delay the fatigue crack growth. Futhermore, in case of the stringer subjected by bending moment, the reinforcement over the upper flange side was determined to be a useful strengthening method, and the reinforcement to the web of the stringer was not appropriate to accomodate as a adequate strengthening method. Also it was confirmed that the category of the fatigue design for the coped stringer met with the category E specified on the fatigue design criteria of the Highway Standard Specification in Korea.

  • PDF

Measurement of Mechanical Properties of a Thermally Evaporated Gold Film Using Blister Test (블리스터 시험법을 이용한 열증착 금박막의 기계적 성질 측정)

  • Moon, Ho-Jeong;Ham, Soon-Sik;Earmme, Yun-Young;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.3
    • /
    • pp.882-890
    • /
    • 1996
  • Mechanical properties, including Young's modulus, residual stress and rupture strength, of a thermally evaporated gold film have been measured form a blister test. In a theoretical study, the priniple of minimum potential energy and that of virtual work have been applied to the pressurized circular membrane problem, and load-deflection relations have been derived for typical membrane deflection mode of spheroidal shape. In an experimental study, circular gold membranes of 4800 A-thickness and 3.5mm diameter were fabricated by the silicon electropolishing technique. Mecahnical properties of the thin gold films were deduced from the load-deflection curves obtained by the blister test, Young's moduli, obtianed from blister test, have been in the range of 45-70 GPa, while those of bulk gold have been in the range of 78-80 GPa. Residual stresses in the evaporated gold films have been measured as 28-110MPa in tension, The rupture strength of the gold film has turned out to be almost equal to that of dental gold alloy (310-380MPa). It has been demonstrated that the present specimen fabrication method and blister test apparatus have been effective for simultaneous measurement of Young's modulus, residual stress and repture strength of thin solid films. Especially, the electropolishing technique employed here has provided a simple and practical way to fabricate thin membranes in a circular or an arbitrary shape, which could not be obtained by the conventional anisotropic silicon mecromachining technique.

Ultimate lateral capacity of two dimensional plane strain rectangular pile in clay

  • Keawsawasvong, Suraparb;Ukritchon, Boonchai
    • Geomechanics and Engineering
    • /
    • v.11 no.2
    • /
    • pp.235-252
    • /
    • 2016
  • This paper presents a new numerical solution of the ultimate lateral capacity of rectangular piles in clay. The two-dimensional plane strain finite element was employed to determine the limit load of this problem. A rectangular pile is subjected to purely lateral loading along either its major or minor axes. Complete parametric studies were performed for two dimensionless variables including: (1) the aspect ratios of rectangular piles were studied in the full range from plates to square piles loaded along either their major or minor axes; and (2) the adhesion factors between the soil-pile interface were studied in the complete range from smooth surfaces to rough surfaces. It was found that the dimensionless load factor of rectangular piles showed a highly non-linear function with the aspect ratio of piles and a slightly non-linear function with the adhesion factor at the soil-pile interface. In addition, the dimensionless load factor of rectangular piles loaded along the major axis was significantly higher than that loaded along the minor axis until it converged to the same value at square piles. The solutions of finite element analyses were verified with the finite element limit analysis for selected cases. The empirical equation of the dimensionless load factor of rectangular piles was also proposed based on the data of finite element analysis. Because of the plane strain condition of the top view section, results can be only applied to the full-flow failure mechanism around the pile for the prediction of limiting pressure at the deeper length of a very long pile with full tension interface that does not allow any separation at soil-pile interfaces.

Foam Separation of Bovine Serum Protein Fractions (소 혈청 단백질 분획들의 기포분리 현상에 관한 연구)

  • Lee, Boo-Yong;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.225-230
    • /
    • 1987
  • The foam separation of bovine serum proteins was investigated and the protein fractionation by foam separation was analyzed by PAG electrophoresis. The protein concentration for the surface excess formation of bovine serum was in the range of $20-800\;{\mu}g/ml$. At pH 5, the foamate volume was maximum, but the enrichment ratio minimum. As the temperature was elevated, the foamate volume decreased and the enrichment ratio increase. As the gas flow rate increased from 25 to 100 ml/min, the foamate volume decreased and the enrichment ratio increased. The enrichment ration became maximum when the added ionic strength of serum solution was in the range of 1-3 by the addition of different types of salts, and this was related to the reduction of surface tension of the solution. In general, BSA, ${\alpha}_1$, and ${\alpha}_2-globulins$, which have relatively small molecular weight and high hydrophobicity, moved easily to the foam, and the separation of protein fractions in the serum varied with the changes in pH, temperature, gas flow rate and ionic strength of the solution.

  • PDF

Fatigue Behavior of the Single Spot Welded Joint of Zinc Galvanized Steel Sheets (아연도금 강판의 점용접재의 피로균형에 관한 연구)

  • 서창민;강성수;오상표
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.21-34
    • /
    • 1992
  • The behavior of fatigue crack growth in the single spot welded joint of zinc galvanized steel sheets was studied experimentally and analytically based on fracture mechanics. Axial tension fatigue tests were carried out with the BSxGAB specimen that the bare plane(GAB) of monogalvanized steel sheet was spot welded to the double thickness bare steel sheet(BS), and with the GAxGAB specimen that the galvanized plane (GA) was spot welded to the equal thickness bare plane (GAB) 1. The relation between maximum stress intensity factor, K sub(max) and the number of cycles to failure, N sub(f) has shown a linear relation on log-log plot in the spot weld of the zinc galvanized steel sheet. 2. The fatigue strength of BSxGAB specimens is about 23% higher than that of GAxGAB specimens at the fatigue strength of $1\times10^6$ cycles. And the fatigue life of BSxGAB specimens at the same load range increases 6~9 times higher than that of GAxGAB specimens. 3. The general tendency at the angle of bending($\theta$) in an applied load has changed rapidly at the initial 20% of its life. After then, it has changed slowly. The change at the angle of bending has increased linearly as the load range increases. 4. It has shown a linear relation between the location ratio of initiation ${\gamma}$ and fatigue life $N_f$ on the semi-log graph paper. Here $\gamma$ means that the crack distance between main crack and sub-crack, 2L is divided by the nugget diameter, 2r. $\gamma=a{\cdot}log N_f+n$ (where a and n are material constant.)

  • PDF

Validity and Reliability on Psychometric Arthritis Impact Measurement Scale-Short Form (AIMS-SF) in Knee Osteoarthritis Patients (골관절염영향측정척도(AIMS-SF)의 타당도 및 신뢰도 - 일부 슬관절 골관절염 환자를 대상으로 -)

  • Yi, Seung-Ju;Nam, Tae-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.5
    • /
    • pp.29-41
    • /
    • 2007
  • Purpose: The aim of this study was to examine the validity and reliability on Psychometric Arthritis Impact Measurement Scale-Short Form (AIMS-SF) in patients with knee osteoarthritis(OA). Methods: The sample consisted of 62 patients who had received physical therapy at the physical therapy units of the Andong Medical Center, Sungso Hospital, Ahn Orthopedic Surgery Clinic, and St. Luke Clinic in Andong city in June 2006. Questionnaire on the AIMS-SF was recruited by 5 physical therapists. The internal structure and reliability of the scales were evaluated by means of item-internal consistency(Cronbach's alpha coefficient: ${\alpha}$), item-discriminant validity, Pearson's relation coefficient. To explore construct validity we conducted a principal component factor analysis with varimax rotation analysis. The criterion for factor extraction was an eigenvalue >1.0. Results: 62 OA patients's an average $age{\pm}standard$ deviation was $53.8{\pm}14.4$ years (range: $40{\sim}81$ yr). The internal consistency reliability of 11 items, as estimated by Cronbach's ${\alpha}$ coefficient, was high ranging $0.60{\sim}0.78$ (except for 0.40 for mobility level and -0.48 for mood). The internal consistency reliability of item-each scale was also high $0.82{\sim}0.93$ (except for 0.48 for mood). Of 11 items, the item-discriminant validity on 6 items was high (${\alpha}$ coefficient range: $0.11{\sim}0.25$), however, others (0.57 for tension level, 0.48 for arthritis pain, 0.41 for walking and bending, and 0.40 for work) were a little low. The construct validity by factor analysis was a little low. Conclusion: In conclusion, the results reported here confirm the validity and reliability of the AIMS-SF in patients with OA of the knee. The Collection of information on health status using this instrument was acceptable to patients. A further prospective multi-center study will be necessary to prove the construct validity.

  • PDF

Comparison of Knee Muscle Strength and Ankle Dorsiflexion Range of Motion Between Standing Workers With and Without Patellofemoral Pain Syndrome

  • Weon, Young-soo;Ahn, Sun-hee;Kim, Jun-hee;Gwak, Gyeon-tae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.241-249
    • /
    • 2020
  • Background: Prolonged standing during work causes a lower extremity pain and disorders. Patellofemoral pain syndrome (PFPS) is one of the common diagnoses of the knee pain. Although the etiology of PFPS is not completely understood, it is considered to be multifactorial. Objects: The purpose of this study was to investigate difference in strength of knee muscles, quadriceps:hamstring muscles strength ratio (Q:H ratio), asymmetry ratio of knee muscles strength and dorsiflexion range of motion (ROM) between standing workers with and without PFPS. Methods: Twenty-eight standing workers with PFPS and 26 age-, height-, and weight-matched standing workers without PFPS participated in this study. A tension sensor measured knee muscle strength, and motion sensor measured dorsiflexion ROM. The asymmetry ratio of knee muscles was calculated by a specific formula using the knee muscles strength of the dominant side and the sound side. An independent t-test was used to identify significant differences in the strength, ROM, Q:H ratio, and asymmetry ratio between the PFPS and normal groups. Results: The standing worker with PFPS have significantly lower dorsiflexion ROM (p < 0.000) and higher asymmetry ratio of the hamstring muscles strength (p < 0.000) compare to the standing worker without PFPS. No significant differences were seen in the strength of quadriceps muscle and hamstring muscles, Q:H ratio, and asymmetry ratio of quadriceps muscle strength. Conclusion: There was a significant difference in the asymmetry ratio of the isometric hamstring muscle strength. This finding suggests that the asymmetry ratio of isometric hamstring muscle strength may be more important than measuring only the hamstring muscle strength of the PFPS side. Furthermore, the results of this study showed a significant difference in dorsiflexion ROM between the standing industrial workers with and without PFPS. Dorsiflexion ROM and isometric hamstring muscle strength should be considered when evaluating the subjects with PFPS.