• 제목/요약/키워드: Tensile specimen

검색결과 1,233건 처리시간 0.03초

내진용 600 및 700 MPa 급 고강도 철근의 미세조직과 인장 특성 비교 (Comparative Study of Microstructure and Tensile Properties of 600 and 700 MPa-Grade High-Strength Seismic Resistant Reinforced Steel Bars)

  • 홍태운;이상인;이준호;심재혁;이명규;황병철
    • 소성∙가공
    • /
    • 제27권5호
    • /
    • pp.281-288
    • /
    • 2018
  • This study deals with the microstructure and tensile properties of 600 and 700 MPa-grade high-strength seismic reinforced steel bars. High-strength seismic resistant reinforced steel bars (SD 600S and SD 700S) were fabricated by TempCore process, especially the SD 700S specimen was more rapid cooled than the SD 600S specimen during the TempCore process. Although two specimens had microstructure of tempered martensite in the surface region, the SD 600S specimen had ferrite-degenerated pearlite in the center region, whereas the SD 700S specimen had bainite-ferrite-degenerated pearlite in the center region. Therefore, their hardness was highest in the surface region and revealed a tendency to decrease from the surface region to the center region because tempered martensite has higher hardness than ferrite-degenerated pearlite or bainite. The SD 700S specimen revealed higher hardness in the center region than SD 600S specimen because it contained a larger amount of bainite as well as ferrite-degenerated pearlite. On the other hand, tensile test results indicated the SD 600S and SD 700S specimens revealed continuous yielding behavior because of formation of degenerated pearlite or bainite in the center region. The SD 600S specimen had a little higher tensile-to-yield ratio because the presence of ferrite and degenerated pearlite in the center region and the lower fraction of tempered martensite enhance work hardening.

PDP 격벽 재료의 인장 물성 측정 방법 (Measurement Method for Tensile Properties of PDP's Barrier Rib Materials)

  • 오충석;배종성;홍병규
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.91-98
    • /
    • 2009
  • A reliable tensile test technique for PDP's barrier rib materials was introduced. A tensile specimen was prepared by punching out of green sheet, curing the specimen in a high temperature furnace, attaching sand paper tabs on each grip ends, and then attaching two strain gages for the strain monitoring and specimen alignment. Preliminary tensile tests were successfully done with the specimens made from ZnO-based lead-free green sheet. The specimens cured at 3 different maximum curing temperatures were tested to demonstrate the applicability of the test method. The Young's modulus was 88 ${\pm}$ 4 GPa regardless of the maximum curing temperature. The ultimate tensile strength was decreased with increasing the temperature. The tensile test method proposed in this study was proven to be reliable, useful and easy to estimate the bulk mechanical properties of barrier rib materials.

순철분말과 인(P)이 피복된 철분말 소결강의 기계적 성질 (Mechanical Properties of Sintered Steel of Pure Iron Powder and Iron Powder Coated with Phosphorus)

  • 정재우
    • 한국분말재료학회지
    • /
    • 제1권2호
    • /
    • pp.181-189
    • /
    • 1994
  • The compacts of pure and phosphorus-coated iron powder with 0~0.8%C were sintered at $1100^{\circ}C$ for 40 min. in cracked ammonia gas atmosphere. The tensile and impact strengths were measured and the relationship of the results with carbon content, phosphorus, quenching and tempering was investigated. The results obtained can be summarized as follows : (1) The tensile strength of sintered compacts increased slowly with carbon content. Increase in tensile strength by heat treatment was evident especially in the low carbon specimen. The specimen with phosphorus showed higher strength compared to pure iron compacts value. (2) No inflection point of elasticplastic deformation on stress-strain curve was observed in sintered steel. The elastic modulus of sintered steel had the same tendency as tensile strength. But the elongation showed the opposite tendency. (3) The impact absorption energy of sintered steel without addition of phosphorus decreased successively with carbon content and by quenching and tempering. On the contrary, addition of phosphorus resulted in an increase of the impact absorption energy. Quenching and tempering did not affect the impact energy especially in high carbon content. (4) The main fracture source was pore in specimen and the propagation of crack occured mostly along the grain boundaries. But the intragranular fracture was also observed in high carbon, quenched and tempered specimen, and especially in the specimen with phosphorus.

  • PDF

도재소부용(陶材燒付用) Ni-Cr 합금(合金)의 재주조(再鑄造)가 물리적(物理的) 성질(性質)에 미치는 영향(影響)에 관(關)한 연구(硏究) (EFFECTS OF THE RECASTING ON THE PHYSICAL PROPERTIES OF Ni-Cr BASED ALLOY FOR FUSED PORCELAIN)

  • 김성일;김춘진;박남수;한무현
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.55-60
    • /
    • 1981
  • Some physical properties of Ni-Cr based alloy for porcelain veneering were compared after repeated casting without the addition of any new alloy. The specimen were cast in a centrifugal caster with an oxygen-propane torch at optimum temperature. The obtained results were as follows: 1. The yield strength and hardness of the second generation were no significant differences compared with first generation but the yield strength and hardness of the third generation slightly decrased. 2. The ultimate tensile strength and elongation appeared to decrease slightly in second, third generations. 3. The tensile fractured facets of the first generation specimen were normal in all specimen, but in the second generation there were six tensile specimen out of ten, in the third there were four tensile specimen out of ten.

  • PDF

ArUco 마커 기반 실시간 인장변형률 측정 시스템 (Real-time Tensile Strain Measurement System based on ArUco Marker)

  • 이승아;김도현;김윤
    • 한국멀티미디어학회논문지
    • /
    • 제24권6호
    • /
    • pp.753-759
    • /
    • 2021
  • During tensile test, tensile strain of tensile tester is measured by movement distance of upper zig and initial specimen's length. Conventional tensile tester program obtains the tensile strain after the end of the test, however the method is not appropriate in real time because the results are calculated until the test is finished. We suggest a real-time measurement system of tensile strain using ArUco Marker in OpenCV library. The system is designed to detect marker attached on the upper zig and calculate specimen's tensile strain. According to comparison of the calculated data and the results of the tester, errors approximately showed 0.128 mm on 3840×2160 video resolution.

Numerical simulation of compressive to tensile load conversion for determining the tensile strength of ultra-high performance concrete

  • Haeri, Hadi;Mirshekari, Nader;Sarfarazi, Vahab;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.605-617
    • /
    • 2020
  • In this study, the experimental tests for the direct tensile strength measurement of Ultra-High Performance Concrete (UHPC) were numerically modeled by using the discrete element method (circle type element) and Finite Element Method (FEM). The experimental tests used for the laboratory tensile strength measurement is the Compressive-to-Tensile Load Conversion (CTLC) device. In this paper, the failure process including the cracks initiation, propagation and coalescence studied and then the direct tensile strength of the UHPC specimens measured by the novel apparatus i.e., CTLC device. For this purpose, the UHPC member (each containing a central hole) prepared, and situated in the CTLC device which in turn placed in the universal testing machine. The direct tensile strength of the member is measured due to the direct tensile stress which is applied to this specimen by the CTLC device. This novel device transferring the applied compressive load to that of the tensile during the testing process. The UHPC beam specimen of size 150 × 60 × 190 mm and internal hole of 75 × 60 mm was used in this study. The rate of the applied compressive load to CTLC device through the universal testing machine was 0.02 MPa/s. The direct tensile strength of UHPC was found using a new formula based on the present analyses. The numerical simulation given in this study gives the tensile strength and failure behavior of the UHPC very close to those obtained experimentally by the CTLC device implemented in the universal testing machine. The percent variation between experimental results and numerical results was found as nearly 2%. PFC2D simulations of the direct tensile strength measuring specimen and ABAQUS simulation of the tested CTLC specimens both demonstrate the validity and capability of the proposed testing procedure for the direct tensile strength measurement of UHPC specimens.

부식이 존재하는 기존 노후 관로에서 인장 시편 가공 시 그립 가공 타당성에 대한 연구 (Validation Study on Processing Grip Part of Tensile Specimen Acquired from Corroded Pipeline)

  • 남영준;김정현;배철호;임윤묵
    • 대한토목학회논문집
    • /
    • 제40권2호
    • /
    • pp.191-195
    • /
    • 2020
  • 부식된 관로의 상태를 평가하기 위해서 수행하는 직접평가 중 인장 실험을 수행하였다. 부식된 관로에서 절삭 가공하여 인장 시편을 취득하면, 관로의 관경에 따라 곡률이 변화하고 실제 평평한 시편의 거동과 달라질 수 있어 이를 확인하기 위한 연구를 수행하였다. 시편의 전 영역이 평평한 경우, 곡률이 있는 경우 그리고 시편에 곡률이 존재하면서 그립 부분만 평평하게 가공한 경우에 대해서 부식이 없는 경우와 부식이 존재하는 경우(두께 대비 25, 50 %의 단일 부식)로 나누어 해석을 진행하였다. 부식이 존재하게 되면 응력 집중이 단면 감소부에서 확실하게 나타나 그립의 가공 여부가 시편의 인장거동에 영향을 거의 주지 않는다는 것을 해석을 통해 확인하였다. 또한 실제 부식이 있는 시편에 대하여 3D 스캔을 진행하고 이를 반영한 해석 모델을 만들어 실험 결과와 비교 분석하였다.

하이드로포밍 공정 전후의 인장 및 피로 물성 변화 (The Variations of Tensile and Fatigue Properties in the Hydroforming Process)

  • 오충석;권순규;최병익
    • 한국정밀공학회지
    • /
    • 제24권12호
    • /
    • pp.111-118
    • /
    • 2007
  • Hydroforming is a cost-effective way of shaping malleable metals such as steel into lightweight, structurally stiff and strong pieces. With the increased use of the hydroformed components in automotive and aerospace industries, it is important to know the variations of the mechanical properties in the hydroforming process far the safe and durable design purposes. The principal goal of this paper is to suggest a procedure to evaluate the variations of tensile and fatigue properties before and after a hydroforming process. A miniature specimen, which is 0.2 mm thick and 2.3 mm wide, is devised and tested to measure local mechanical properties. The effects of specimen size, defects, surface roughness, and hydroforming on the tensile and fatigue behaviors are discussed.

자가치료용 마이크로캡슐이 구조재의 기계적 특성에 미치는 영향 (Effect of autonomic microcapsules on mechanical properties of structural materials)

  • 소진호;윤성호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.508-511
    • /
    • 2004
  • This study focused on the effect of autonomic microcapsules on the mechanical properties of structural material. Several types of microcapsules with healing agents were manufactured by varying agitation speed of high speed stirrer. The size distribution of microcapsules was measured by a particle size analzer. The epoxy specimens embedded with microcapsules were manufactured and the degree of cure of such epoxy specimen was measured by a differential scanning calorimetry. The tensile modulus and tensile strength in epoxy specimens embedded with microcapsules were evaluated in order to investigate the effects of microcapsules on mechanical properties of structural materials. The configuration of microcapsules and morphology of fracture surfaces for the epoxy specimen were examined by an optical microcope and a scanning electron microscope. According to the results, tensile strength of the epoxy specimen embedded with microcapsules was indicated a little reduction, but tensile modulus was not much affected on microcapsules.

  • PDF

소둔로에서 수욕으로 이송 중 발생한 표면 산화가 TWIP 강의 미세조직과 인장 성질에 미치는 영향 (The Effects of Surface Oxidation Occurring during Delivery from an Annealing Furnace to a Water Bath on the Microstructure and Tensile Properties of TWIP Steel)

  • 오선근;이영국
    • 열처리공학회지
    • /
    • 제33권2호
    • /
    • pp.57-64
    • /
    • 2020
  • In the present study, we investigated whether the surface oxidation of C-bearing TWIP steel ℃curs in the air during specimen delivery from an annealing furnace to a water bath and how the microstructure and tensile properties are influenced by surface oxidation. A cold-rolled Fe-18Mn-0.6 (wt%) steel was exposed in the air for 5 s after annealing at various temperatures (750℃, 850℃ and 1000℃) for 10 min in a vacuum, and then water-quenched. For comparison, another specimen, which had been quartz-sealed in a vacuum, was annealed at 1000℃ for 10 min and immediately water-quenched without exposure to air. The 750℃ and 850℃-annealed specimens and the quartz-sealed specimen showed a γ-austenite single phase in the entire specimen due to negligible surface oxidation. However, the 1000℃-annealed specimen exhibited a dual-phase microstructure consisting of ε-martensite and γ-austenite at the sub-surface due to decarburization. Whereas the specimens without decarburization revealed high elongations of 70-80%, the decarburized specimen exhibited a low elongation of ~40%, indicating premature failure due to cracking inside the decarburized layer with ε-martensite and γ-austenite.