• 제목/요약/키워드: Tenax adsorption

검색결과 13건 처리시간 0.021초

Adsorption and Desorption of Chemical Warfare Agent Simulants on Silica Surfaces with Hydrophobic Coating

  • Park, Eun Ji;Kim, Young Dok
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권7호
    • /
    • pp.1967-1971
    • /
    • 2013
  • Aim of our study is finding adsorbents suitable for pre-concentration of chemical warfare agents (CWAs). We considered Tenax, bare silica and polydimethylsiloxane (PDMS)-coated silica as adsorbents for dimethyl methylphosphonate (DMMP) and dipropylene glycol methyl ether (DPGME). Tenax showed lower thermal stability, and therefore, desorption of CWA simulants and decomposition of Tenax took place simultaneously. Silica-based adsorbents showed higher thermal stabilities than Tenax. A drawback of silica was that adsorption of CWA simulant (DMMP) was significantly reduced by pre-treatment of the adsorbents with humid air. In the case of PDMS-coated silica, influence of humidity for CWA simulant adsorption was less pronounced due to the hydrophobic nature of PDMS-coating. We propose that PDMS-coated silica can be of potential importance as adsorbent of CWAs for their pre-concentration, which can facilitate detection of these CWAs.

흡착관/열탈착 GC/MS 방법에 의한 모사시료 중의 미량 페놀 분석에 관한 평가 (Evaluation of the Measurement of Trace Phenols by Adsorption/Thermal Desorption/Gas Chromatography/Mass Spectrometry (ATD/GC/MS) in Artificial Air)

  • 허귀석;이재환;황승만;정필갑;유연미;김정우;이대우
    • 한국대기환경학회지
    • /
    • 제18권2호
    • /
    • pp.127-137
    • /
    • 2002
  • Phenolic compounds in air are toxic even at their low concentrations. We had evaluated a total of five phenolic compounds (Phenol, o-Cresol, m-Cresol, 2-Nitrophenol and 4-Chloro-3-methylphenol) in artificial air using a combination of ATD/GC/MS. To compare the adsorption efficiency of these phenolic compounds, three adsorbents (Tenax TA, Carbotrap and Carbopack B) were tested. Tenax TA adsorbent was most effective of all the adsorbents used for the efficiency test. Five phenolic compounds were found to be very stable on adsorbent tubes for 4 days at room temperature. Detection limit of five phenolic compounds ranged from 0.05 to 0.08 ppb (when assumed to collect 10 L air). The calibration curve was linear over the range of 22∼ 164 ng. The reproducibility was less than 4%. Sampling of duplicate pairs (DPs) was made to demonstrate duplicate precision and sampling efficiency.

Sorbent Thermal Desorption/Gas Chromatography/Mass Selective Detection Method for Determination of Gaseous Polycyclic Aromatic Hydrocarbons in Indoor Air

  • Dai, Shugui;Zhang, Lin;Zhu, Tan
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.753-758
    • /
    • 1995
  • Thermal desorption/gas chromatography/mass selective detection method using Tenax cartridges for the determination of gaseous polycyclic aromatic hydrocarbons(PAH) is described. Glass fiber filter can collect only PAH in particulate. Gaseous PAH may penetrate the filter. Glass cartridge packed Tenax-GC was uses fur adsorption of gaseous PAH. The air of inhalation zone was collected fur 2-10 hours. Cartridges were thermally desorbed in the reverse direction to sample flow. The desorption conditions were as follows; desorption temperature; $300^{\circ}C$; desorption time; 20min; column head pressure; 30psi; inlet split vent; closed during desorption.

  • PDF

Comparison on Usefulness of Sampling Methods of Indoles in Airs from Swine Facility by Tenax-TA and SPME

  • Yu, Mee-Seon;Lee, Jae-Chun;Yang, Sung-Bong;Kim, Doo-Hwan;Cho, Sung-Back;Whang, Ok-Wha
    • 한국환경과학회지
    • /
    • 제22권12호
    • /
    • pp.1539-1549
    • /
    • 2013
  • The purpose of this study is to compare the sampling methods for monitoring indoles (phenol, p-cresol, indole and skatole) in airs of swine facility. As the collecting methods of indoles in air, Tenax-TA adsorption tube and solid phase microextraction (SPME) were examined. For the preparation of calibration curves of indoles concentrated in Tenax-TA, the standard indoles solutions were spiked in each of Tenax-TA tubes and thermally desorbed (ATD) into a gas chromatograph combined with mass detector (GC/MS). And for the preparation of calibration curves by SPME, indoles in the standard gaseous solution prepared by evaporating the aqueous solution that contained indoles into a polyester sampling bag were extracted with SPME fiber and subsequently analyzed by the GC/MS. Two sampling methods were evaluated for extracting indoles present in swine building environments. Results indicated that the SPME method using Polydimethylsiloxane/ Divinylbenzene (PDMS/DVB) fiber was more effective than Tenax-TA method in extracting indoles. The gas chromatographic analysis showed that the linearities of calibration curves and detection limits were useful for detection of indoles in swine airs. The field tests also showed that considerably different levels of indoles were present in various parts of the swine building.

환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구 (A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere)

  • 손은성;서영교;이동현;이민도;한진석;백성옥
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

들깨(Perilla frutescens)와 쑥(Artemisia asiatics)잎으로부터 휘발성 타감 작용 성분의 분리 (Isolation of Volatile Allelochemicals from Leaves of Perilla frutescens and Artemisia asiatica)

  • 임선욱;서영호;이영근;백남인
    • Applied Biological Chemistry
    • /
    • 제37권2호
    • /
    • pp.115-123
    • /
    • 1994
  • 본 연구는 들깨와 쑥 잎의 휘발성 타감작용을 확인하고, 그 성분을 동정하려 한 것이다. 휘발성분을 벼, 무우, 녹두, 상치를 대상으로 생물검정하여 휘발성 타감작용을 확인했다. 휘발성분을 headspace cold trapping-Tenax GC 흡착으로 분리하여 들깻잎으로부터 terpenoid 4종, aldehyde 3종, alcohol 3종, 탄화수소류 3종, 기타 성분 1종을 동정하였으며, 쑥으로부터는 terpenoid 9종, aldehyde 3종, alcohol 1종, 기타 성분 1종을 검출하였다. 한편, 수증기 증류-추출로 포집한 경우에는, 들깻잎으로부터 terpenoid 2종, alcohol 2종의 동정되었으며, 쑥 잎으로부터는 terpenoid 6종, alcohol 1종, 탄화수소류 1종, 기타 성분 2종이 검출되었다. 수증기 증류-추출로부터 나누어진 각 분획을 무우를 대상으로 생물검정한 결과 중성 분획이 가장 타감작용 활성이 컸다. 휘발성 타감작용 성분을 분리하기 위해 이를 GC-MS로 분석한 결과, 들깨로부터 terpenoid 7종과 alcohol 2종 등 9종을 동정하였고, 쑥으로부터 terpenoid 15종과 alcohol 3종, aldehyde 1종, 탄화수소류 2종, 기타 성분 3종 등 24종을 동정하였다.

  • PDF

Triple-bed Adsorbent Tube를 이용한 가스상 극미량 복합 악취 및 휘발성 유기화합물의 동시 분석 (Simultaneous Analyses for Trace Multi-Odorous and Volatile Organic Compounds in Gas using a Triple-bed Adsorbent Tube)

  • 서용수;이제근
    • Korean Chemical Engineering Research
    • /
    • 제48권2호
    • /
    • pp.244-252
    • /
    • 2010
  • 본 연구에서는 Triple-bed 흡착튜브를 제작하여 열탈착장치와 GC-MS로써 다성분 복합 악취성물질 및 휘발성유기 화합물을 동시분석 가능성을 평가하고자 하였다. Triple-bed 흡착튜브는 하나의 튜브에 Tenax-TA와 소량의 Carbopack B 및 Carbosieve SIII 흡착제를 흡착강도 순으로 3단 배열된 것이다. GC-MS의 분석조건은 mass range 20~350 m/z, 불순물 1 ppm 이하의 헬륨을 운반가스로 하여 저비점 저분자량 물질의 분리동정에 효과적일 수 있도록 하고, 목적이온 추출을 통하여 정량하였다. 그 결과 ppbv 수준의 $C_1{\sim}C_5$의 알콜(4), 알데히드(6), 케톤(2) 그리고 황화합물(2)을 포함한 14종의 물질 모두 99%이상의 회수율과 양호한 재현성 및 직진성으로 동시분석이 가능하였다. 비교적 휘발성이 강하고 분자량이 낮은 물질인 메틸알콜, 아세트알데히드는 상대습도 45% 이하, 흡착유속 50 mL/min, 흡착량 2 L 이하에서 높은 회수율로 보다 안정적으로 정량분석이 가능하였다. 또한 목적이온 추출은 물질피크가 겹쳐 나타난 경우에도 다성분 물질을 각각 정량 가능하였다.

Characterization of Fennel Flavors by Solid Phase Trapping-Solvent Extraction and Gas Chromatography-Mass Spectrometry

  • Shin, Yeon-Jae;Jung, Mi-Jin;Kim, Nam-Sun;Kim, Kun;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2389-2395
    • /
    • 2007
  • Headspace solid phase trapping solvent extraction (HS-SPTE) and GC-MS was applied for the characterization of volatile flavors from fennel, anise seed, star-anise, dill seed, fennel bean, and Ricard aperitif liquor. Tenax was used for HS-SPTE adsorption material. Recoveries, precision, linear dynamic ranges, and the limit of detection in the analytical method were validated. There were some similarities and distinct differences between fennel-like samples. The Korean and the Chinese fennels contained trans-anethole, (+)-limonene, anisealdehyde, methyl chavicol as major components. The volatile aroma components from star anise were characterised by rich trans-anethole, (+)-limonene, methyl chavicol, and anisaldehyde. Additionally, principal component analysis (PCA) has been used for characterizing or classifying eight different fennel-like samples according to origin or other features. A quite different pattern of dill seed was found due to the presence of apiol (dill).

Analysis of Flavor Composition of Coriander Seeds by Headspace Mulberry Paper Bag Micro-Solid Phase Extraction

  • Cha, Eun-Ju;Won, Mi-Mi;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권11호
    • /
    • pp.2675-2679
    • /
    • 2009
  • This paper reports the example of headspace mulberry paper bag micro solid phase extraction (HS-MPB-$\mu$-SPE) as a new sampling method for the determination of volatile flavor composition of coriander seeds. Adsorption efficiencies between two configurations of mulberry paper bag were compared, and several parameters affecting the HS-MPB-$\mu$-SPE were investigated and optimized. The optimized technique uses an adsorbent (Tenax TA, 0.1 mg) contained in a mulberry paper bag of front configuration where fine surface was outside, and minimal amount of organic solvent (0.6 mL). Linalool and $\gamma$-terpinene were found as abundant flavor compounds from coriander seeds. The limit of detection (LOD) and the limit of quantitation (LOQ) for linalool of major flavor in coriander seeds were 10.3 ng/mL and 34.4 ng/mL, respectively. The proposed method showed good reproducibility and good recovery. The HS-MPB-$\mu$-SPE is very simple to use, inexpensive, requires small sample amounts and solvent consumption. Because the solvent for extraction is reduced to only a very small volume, there is minimal waste or exposure to toxic organic solvent and no further concentration step.

Sorption Behavior of 1-Methylcyclopropene on Adsorbing Agents for Use in Extending the Freshness of Postharvest Food Products

  • Lee, Youn-Suk;Shin, Han-Seung
    • Food Science and Biotechnology
    • /
    • 제15권4호
    • /
    • pp.572-577
    • /
    • 2006
  • The physiochemical interactions of 1-methylcyclopropene (1-MCP) and adsorbing agents can be described using a very powerful tool, inverse gas chromatography (IGC). Sorption behavior of 1-MCP on various adsorbing agents was assessed using the profile peaks of 1-MCP at an infinite dilution concentration using the IGC technique. Chromatogram peaks of 1-MCP adsorption were not observed for the adsorbing agent activated carbon. The forms of sorption isotherms followed Henry's law, and behaved according to the binding site theory. Specific retention volume and distribution coefficients for 1-MCP on the adsorbing agents were determined at 50, 60, 70, and $80^{\circ}C$, respectively. Silica gel had a much higher number of binding sites for 1-MCP compared to Tenax-TA and activated clay agents. Meanwhile, activated carbon proved to be a very strong binding agent for 1-MCP based on 1-MCP efficiency experiments on the selected adsorbing agents. However, as a proper means of delivering 1-MCP molecules to fresh food products, activated carbon is not fit for the binding and release of 1-MCP gas under dry or high humidity conditions because activated carbon has a strong affinity for 1-MCP, even when treated with distilled water.