• Title/Summary/Keyword: Temporary teeth

Search Result 88, Processing Time 0.018 seconds

PULP REACTIONS TO TEMPORARY CEMENTS (임시(臨時) 접착용(接着用) 씨멘트가 치수조직(齒髓組織)에 미치는 영향(影響))

  • Yoon, Doo-Joong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.15 no.1
    • /
    • pp.43-47
    • /
    • 1977
  • The purpose of this study was to determine human pulp reactions to temporary cements such as zinc oxide-eugenol cement, modified zinc oxide-eugenol cement (Cavitec) and calcium hydroxide cement (Dycal). Deep class V cavities were prepared in the human teeth with ultrahigh-speed handpiece operating at a free running speed of 300,000 r.p.m., using # 701 bur and water spray coolant. The cavities were flushed with water, dried with cotton pellets and filled with zinc oxide-eugenol cement, modified zinc oxide-eugenol cement and calcium hydroxide cement respectively. The teeth were divided into two groups, which one group was extracted after One day and the other was extracted after seven days. The samples were examined with microscope and the findings were as follows; 1. The pulp reactions to temporary cements were generally mild. Among them the reactions were moderate in zinc oxide-eugenol cement and, slight in calcium hydroxide cement. 2. Calcium hydroxide cement may be used properly as temporary cement for the purpose of pulp protection.

  • PDF

A STUDY OF THE INFLUENCE ON PHONATION WHEN MAXILLARY ANTERIOR TEETH ARE MISSING (상악 전치부 결손이 발음에 미치는 영향에 관한 연구)

  • Roh Chang-Sup;Choi Dae-Gyun;Woo Yi-Hyung;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.338-360
    • /
    • 1992
  • This study was performed to investigate the phonetic alterations with upper anterior teeth were missing. To compare the changes of the phonations, before and after insertion of the temporary prosthesis, six subjects who lost their upper anterior teeth were selected (2-male, 4-female). Tested sounds (/ga(가), na(나), da(다), ra(라), sa(사), ja(자), cha(차), ta(타), pa(파), ha(하), gi(기), ni(니), di(디), ri(리), si(시), jl(지), chi(치), ti(티), pi(피), hi(히), seu(스), se(세), so(소), su(수)/were programmed into an IBM AT with and without temporary prosthesis. These experiments were analyzed by formants, consonants durations, and energy level changes with an LSI speech work station program. During the pronunciation of the tested sounds (with and without temporary prosthesis), mandibular movements were recorded to a Mandibular Kinesiogram and analyzed . The findings led to the following conclusions: 1. Objective differences could not be found. However, in every informant, subjective improvement could be noticed. 2. There were no persistant correlations of the formant's changes. And in every informant, phonetic changes were variable. 3. There were various changes of the consonant durations in every informant. By and large, those of /si(시), jl(지), chi(치), Pi(피), hi(히)/ were longer than other tested sounds. After insertion of the prosthesis, durations were shorter. Consonants with /i(ㅣ)/ were longer than with /a(ㅏ)/, with or without prosthesis. 4. With and without temporary prosthesis, mandibular movements were various in the frontal view. Mandibular movements showed lateral deviations, and mandibular positions with /si(시), ji(지), ti(티), seu(스), hi(히)/ were nearer to the mandibular rest position. 5. The kinds of temporary prosthesis and conditions of the missing teeth influenced every informant variously, so there were no correlation between informants. 6. Energy levels increased in all tested sounds with a fixed temporary prosthesis. And, there were no differences between before and after insertion of a removable temporary prosthesis. However, sibilant sounds, and consonants with /i(ㅣ)/ showed a little increased energy level.

  • PDF

Effectiveness of anchorage with temporary anchorage devices during anterior maxillary tooth retraction: A randomized clinical trial

  • Barthelemi, Stephane;Desoutter, Alban;Souare, Fatoumata;Cuisinier, Frederic
    • The korean journal of orthodontics
    • /
    • v.49 no.5
    • /
    • pp.279-285
    • /
    • 2019
  • Objective: This study evaluated the efficiency of anchorage provided by temporary anchorage devices (TADs) in maxillary bicuspid extraction cases during retraction of the anterior teeth using a fixed appliance. Methods: Patients aged 12 to 50 years with malocclusion for which bilateral first or second maxillary bicuspid extractions were indicated were included in the study and randomly allocated to the TAD or control groups. Retraction of the anterior teeth was achieved using skeletal anchorage in the TAD group and conventional dental anchorage in the control group. A computed tomography (CT) scan was performed after alignment of teeth, and a second CT scan was performed at the end of extraction space closure in both groups. A three-dimensional superimposition was performed to visualize and quantify the maxillary first molar movement during the retraction phase, which was the primary outcome, and the stability of TAD movement, which served as the secondary outcome. Results: Thirty-four patients (17 in each group) underwent the final analysis. The two groups showed a significant difference in the movement of the first maxillary molars, with less significant anchorage loss in the TAD group than that in the control group. In addition, TAD movement showed only a slight mesial movement on the labial side. On the palatal side, the mesial TAD movement was greater. Conclusions: In comparison with conventional dental anchorage, TADs can be considered an efficient source of anchorage during retraction of maxillary anterior teeth. TADs remain stable when correctly placed in the bone during the anterior tooth retraction phase.

Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer (DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

Numerical Analysis on Posterior Prosthesis of Implant Temporary Teeth Combination Bridge (임플란트 임시치아 결합형 브리지의 구치부 보철물에 대한 수치해석)

  • Seo, Kyung-Hyo;Lee, Chi-Woo;Moon, Byung-Cheol
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.60-65
    • /
    • 2014
  • This research examined an immediate loading capable of providing a masticatory function and financial affordability while satisfying every requirement of a useful immediate loading. In this research, numerical value analysis was performed on couple-type posterior teeth implants developed by making up for the problems of extant implants. As a result of examining the effects of external impacts on extant implants and their deformation, relatively lager deformations separated from a molar were found concerning molar deformation implant with the maximum deformation level being approximately 1.657mm. In this research, the improved implant showed much improvement in terms of impact analysis in its deformation dispersion status after unloading the impulsive load from a punch. As for the case of hepf, about 1.657mm occurred but the improved model showed about 0.9217mm, exhibiting 55.6% advancement.

Full mouth rehabilitation with vertical dimension elevation in the patient with severely worn dentition: case report (과도한 치아 마모 환자에서 수직고경 증가를 동반한 전악 수복 증례)

  • Lee, Eun-Jee;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.315-323
    • /
    • 2014
  • Excessive teeth abrasion causes pathologic changes of oral environment and masticatory system due to decrease in occlusal vertical dimension. When establishing new occlusal plane and recovering vertical dimension, accurate diagnosis and analysis are essential. In this case, after appropriate centric relation in elevated vertical dimension was taken using Gothic arch tracer, full mouth rehabilitation was performed. A 70-year-old male patient had the chief complaint that he could not eat due to teeth wear. He showed generalized teeth wear and decreased vertical dimension. Elevation of vertical dimension was planned by model analysis. According to increased vertical dimension, centric relation was recorded using Gothic arch tracer and temporary prostheses were applied. Appropriate occlusion was established by temporary prostheses for 4 months. Final prostheses were fabricated using vertical dimension adapted by temporary prostheses. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

A Study on the Color Stability of Temporary Resins according to Polymerizing Methods and Staining (온성 방법에 따른 수종의 임시 수복용 레진의 착색시의 색 안정성에 관한 연구)

  • Park, Sung-Ho;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • Dental temporary resin should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental temporary resin has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 resins($Snap^{(R)}$, Temporary bridge $resin^{(R)}$, Trim $II^{(R)}$) according to polymerizing methods and stainning. The resins were divided into groups by 2 types of polymerizing methods ( air or pressure and heat curing) The resins were dyed with coffee, chlorhexidine and artificial saliva and then the color stability was evaluated with a spectrophotometer(CM-503i, Minolta, Japan). The results were as follows ; 1. In the color stability according to polymerizing method, pressure and heat polymerizing method was higher than air polymerizing method. 2. The color stability according to staining fluid decreased in the order of I, II, III group, there was significant difference among the groups of staining fluid. 3. The color stability according to resins decreased in the order of $Snap^{(R)}$, Trim $II^{(R)}$, Temporary Bridge $resin^{(R)}$, The $Snap^{(R)}$ resin was highest color stability, there was significant difference among the 3 resins.

  • PDF

Esthetic provisional restoraions of anterior region (심미적인 전치부 임시치아 제작법)

  • Kim, Deok jung
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.51-61
    • /
    • 2018
  • Temporary restoration is one of the important processes in prosthodontic treatment, but some clinicians do not care about it. Most temporary restorations are literally used for a while, so most dentists like fast and cheap things. With the advent of dental CAD/CAM that can be made faster and easier with the changing age, the production of temporary restoration is also being digitized. It is good to be comfortable, but there are advantages and disadvantages. In this article, we are going to look at the 'analogue aesthetic anterior teeth temporary method' which seems to be the last generation.

Coronal microleakage of four temporary restorative materials in Class II-type endodontic access preparations

  • Yun, Sang-Mi;Karanxha, Lorena;Kim, Hee-Jin;Jung, Sung-Ho;Park, Su-Jung;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.29-33
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the microleakage of 4 temporary materials in teeth with Class II-type endodontic access preparations by using a glucose penetration model. Materials and Methods: Glucose reaction test was performed to rule out the presence of any reaction between glucose and temporary material. Class II-type endodontic access preparations were made in extracted human premolars with a single root (n = 10). Each experimental group was restored with Caviton (GC), Spacer (Vericom), IRM (Dentsply-Caulk), or Fuji II(GC). Microleakage of four materials used as temporary restorative materials was evaluated by using a glucose penetration model. Data were analyzed by the one-way analysis of variance followed by a multiplecomparison Tukey test. The interface between materials and tooth were examined under a scanning electron microscope (SEM). Results: There was no significant reaction between glucose and temporary materials used in this study. Microleakage was significantly lower for Caviton and Spacer than for Fuji II and IRM. SEM observation showed more intimate adaptation of tooth-restoration interfaces in Caviton and Spacer than in IRM and Fuji II. Conclusions: Compared to IRM and Fuji II, Caviton and Spacer can be considered better temporary sealing materials in Class II-type endodontic access cavities.

JAW RELATION WITH PERMANENT RECORD BASES IN THE EDENTULOUS PATIENTS (총의치 환자에 있어 Permanent record base를 이용한 악간관계 기록)

  • Heo, Yun-Seok;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.231-239
    • /
    • 1995
  • When the complete denture is made, the record base for jaw relation is divided into temporary record base and permanent record base. However, The temporary record base include some disadvantages such as, the lackness of intimate contact between model and base, the lackness of retention during the jaw relation registration, When we obtained jaw relation the permanent record bases made from heat curing resin were utilized. We could get several advantages as follows : 1. The permanent record base provided intimate contact between the model and record base. 2. In fabricating occlusal rim on record base, the dimensional change of record base was little because the permanent record base was lesser influenced to thermal change of occlusal rim than the temporary record base. 3. At the stage of jaw relation, the retention of final denture could be early checked. 4. It could be able to get more accurate registration of jaw relation because all procedure were done on the same base during the jaw relation, artificial teeth arrangement, try-in, and final denture construction. 5. Although there was an inconvenience due to double curing procedure, the shrinkage rate in resin polimerization was relatively reduced so that more dimensional stability could be taken.

  • PDF