• 제목/요약/키워드: Temporary steel

검색결과 130건 처리시간 0.027초

토목공사 안전관리비 적정요율 산정 (Appropriate Rate for Estimating Safety Management Cost in Civil Work)

  • 손기상;이기태;박종근;박정봉
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.73-84
    • /
    • 2006
  • Standard safety management cost system was established in 1988 as a decree Number of 88-13, first time. And then, it has been revised fourteen times, up to now. A lot of practical investigations have been made for the revision but many problems at sites are continued to be put out so that it should be revised. This study is to find out hazard level of each work kinds through questionnaire and interview and investigate analyze the status which standard safety management costs have been used. Also, this study is to show reasonable rates of standard safety management costs in construction industry and to set up countermeasures against those problem after reviewing its status in korea with in Japan and Europe. Budget and actually performed amount of safety management costs in this study are investigated. costs for temporary work which is clarified in Japan is collected in order to compare domestic cost rate with Japanese one related to the total project amount. This study is to investigate eleven project kinds of domestic system, first, and to investigate eleven items of apartment bldg, office, civil work such as bridge, tunnel, dam, plant etc, secondly. Additionally, three items of gymnasium, railway, particular steel tower are investigated in this study. Also this study is to investigate and analyze performed costs of presently processing worker finished work so that it shows a new reasonable rate against standard safety management costs in construction industry, in order to make basical data and material to be systemized.

역해석 기법에 의한 연약지반 NATM터널 굴착사례 연구 (A Case Study on the NATM Tunnel Excavation under the Soft Soil Ground Condition by Back Analysis Method)

  • 조현;박종인;이기환
    • 한국터널지하공간학회 논문집
    • /
    • 제2권3호
    • /
    • pp.71-81
    • /
    • 2000
  • NATM 터널을 시공함에 있어서 정확한 지반조사 결과에 의한 설계가 요구되나, 현실적으로 완벽하게 지반조건을 파악하지 못하고 설계가 진행되는 경우가 많다. 특히 연약지반 또는 지하수의 유입이 급격히 진행되는 등의 열악한 지반과 조우하였을 때에는 현황을 최적으로 반영할 수 있는 계측결과에 기준한 적절한 보강공사 등의 터널의 안정성 확보가 요구된다. 본 보고서에서는 토사 터널 구간의 시공에 있어서, 발생한 변위량을 재현할 수 있도록 터널 계측결과를 이용한 역해석 (back analysis)을 통해 지반의 공학적 제상수를 재평가 한 후, 유한차분법을 이용한 수치해석을 이용하여 최적의 터널 안정성을 검토하였다. 또한 수치해석 결과 및 시공 현황 등을 고려하여 터널 측벽 및 하반부에 강관 일단식 그라우팅과 상반 굴착 후에 가인버트 공법 등을 적용하여 터널의 역학적 안정성을 확보한 토사구간의 굴착을 완료하였다.

  • PDF

실물형 액체로켓 연소기의 연소안정성에 대한 시험적인 고찰 (Experimental Study on the Combustion Stability of Full Scale Rocket Combustor)

  • 이광진;서성현;강동혁;송주영;임병직;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.240-246
    • /
    • 2005
  • 현재 개발 중에 있는 30-tonf-class 실물형 액체로켓연소기는 이미 설계검증을 위해 수차례의 연소시험이 이루어졌으며 그 결과 높은 연소효율을 얻었다. 연소성능과 더불어 액체로켓연소기의 중요한 또 하나의 요소는 바로 연소안정성이다. 연소안정성에 대한 평가시험은 개발하고자 하는 액체로켓연소기의 연소불안정 발생 빈도를 파악하는 시험으로서 액체로켓연소기 개발시 꼭 확인해야하는 시험이라 할 수 있다. 펄스건을 이용한 스테인레스 스틸 재질의 임시 배플이 장착된 실물형 연소기의 연소안정성 평가시험은 성공적으로 수행되었으며 그 결과 우수한 연소안정성 특성을 얻었다. 시험결과는 다음 호기의 실물형 연소기 배플 설계에 활용될 예정이다.

  • PDF

유한요소 해석을 통한 형상 및 크기에 따른 가물막이 특성 검토 (The Structural Characteristics of the Temporary Cofferdam in Accordance with the Shape and Size Obtained from Numerical Analysis)

  • 김현주;최진오;권윤호
    • 한국지반공학회논문집
    • /
    • 제36권1호
    • /
    • pp.29-38
    • /
    • 2020
  • 최근 환기구, 비상탈출용 수직구, 취수탑 가시설 등 지중 가물막이 또는 차수벽체로 원형 가물막이가 많이 적용되고 있다. 원형단면의 경우 벽체에 작용하는 토압이 원형가물막이 형상에 따라 아칭효과(arching effect)로 인하여 작용토압에 대한 구조체의 부재력이 감소하는 것으로 알려져 있다. 본 연구에서는 원형 가물막이에 대한 2D 유한요소해석(FEM)을 활용하여 원형띠장(ring beam) 강성을 산출 후 탄소성해석에 적용하여 부재의 단면력을 검토하였다. 더불어 3D 유한요소해석(FEM)을 통하여 원형단면의 가물막이가 다각형 형태의 가물막이보다 전단력, 휨모멘트, 그리고 발생변위가 최소값을 갖는 것으로 나타났으며, 이로써 원형단면 가물막이가 구조적으로 보다 효율적인 단면 형태임을 확인하였다

신형 SRC 복공판의 개발에 관한 연구 (A Study on the Development of New SRC Lining Board)

  • 권범준;박도욱;김용수
    • 한국건설관리학회논문집
    • /
    • 제6권4호
    • /
    • pp.172-180
    • /
    • 2005
  • 본 연구는 지하 시설 공사 시 도로면을 복개하기 위하여 사용되고 있는 복공판이 공사차량이나 화물차량 통행 시 반복되는 과하중을 견디지 못하여 피로에 의해 파괴되는 문제점을 분석, 이를 보완하는 신형 SRC 복공판을 제시하고자 한다 이를 위해 현재 노면복공에 사용되고 있는 기존 복공판의 형상을 통해 문제점을 분석하여 신형 SRC 복공판을 제안하고 정재하실험과 피로실험을 통하여 신형 SRC 복공판의 활용가능성을 검증하였다. 이와 같은 과정을 통한 본 연구의 결과는 다음과 같다: 1) 기존 복공판의 문제점을 보완하기 위해 단면강성이 큰 H형강을 병렬배치 하여 복공판 상부에 400kgf/cm$^{2}$ 강도의 콘크리트를 타설, 콘크리트 포장 푠면에 그루빙(Grooving) 처리하여 기존 복공판에 비해 미끄럼방지 성능을 향상시킬 수 있는 신형 SRC 복공판을 개발하였다. 3) 정재하실험결과 기존 복공판이 최대하중 27.01tonf에서 변형되어 용접부분이 파괴되는 것에 비해 신형 SRC 복공판이 최대하중 78.8tonf에서 변형되어 기존 복공판보다 우수한 것으로 분석되었다. 또한 피로실험결과 기존 복공판이 3,900회의 피로실험 시 용접부위의 국부적인 균열이 발생한 것에 비해 신형 SRC복공판의 100만회 피로실험결과 특별한 변형이 일어나지 않아 기존 복공보다 강성이 우수한 것으로 분석되었다.

인접지역의 깊은 터파기 굴착에서 변위 및 응력의 계측 (Displacement and Stress Monitoring for Excavation Deep Foundation)

  • 원연호
    • 화약ㆍ발파
    • /
    • 제17권1호
    • /
    • pp.27-55
    • /
    • 1999
  • The excavation works for deep foundation in urban areas have recently increased complaints of blasting vibration and settlement of ground level. Foundation must be excavated approximately up to 24-28m depths from the surface. The roads and subway line pass through the excavation area. The Dae-chung station is also located at the nearest distance 5-35m from the working site. To protect subway station and adjacient some structures from blasting and settlement, the level of ground vibration, displacements and stress were monitored and analyzed. The results can be summarized as follows ; 1. An empirical particle velocity equation were obtained by test blasts at Nassan Missi 860 Office tel construction site. $V{\;}={\;}K(D/\sqrt{W})^{-n}$, where the values for n and k are estimated tobe 0.371 and 1.551. From this ground vibration equation, the max. charge weight per delay time against distance from blasting point is calculated. Detailed blasting method is also presented. 2. To measure the horizontal displacement in directions perpendicular to the borehole axis, 6 inclinometers installed around working sites. The displacement at the begining was comparatively high because the installation of struts was delayed, but after its installation the values showed a stable trend. Among them, the displacement by 3 inclinometers installed on a temporary parking area showed comparatively high values, for example, the displacement measured at hole No. IC-l recoded the max. 47.04mm for 6 months and at hole No. IC-2 recorded the max. 57.33mm for 7 months. So, all of these data was estimated below a safe standard value 103mm. 3. Seven strain gauge meter was installed of measure the magnitude and change of stress acted on structs. The measured value of maximum stress was $-465{\;}kgf/\textrm{cm}^2,{\;}-338.4{\;}kgf/\textrm{cm}^2,{\;}302.3{\;}kgf/\textrm{cm}^2$ respectively. In compareto the allowable stress level of steel, they are estimated to be safe.

  • PDF

구조물 겸용 흙막이 스트러트 공법의 개선 연구 (A Study on the Technological Improvement of Strut as a Permanent Structure)

  • 김선국;홍원기
    • 한국건설관리학회논문집
    • /
    • 제9권5호
    • /
    • pp.186-193
    • /
    • 2008
  • 흙막이를 지지하는 버팀대를 가설재가 아닌 주(主)구조체로 이용하는 SPS(Strut as a Permanent System) 공법이 개발되어 최근 국내 공사현장에서 활발하게 활용되고 있다. 이 공법은 건축공사 현장에서 원가절감, 공기단축, 구조적 안정성 향상, 건설환경 개선 등 다양한 이점을 주는 반면 지하층고의 증가와 철골부위 내화피복을 추가로 수행하여야 하는 문제점이 있다. 지하층고의 증가는 흙막이 깊이 및 지하 최저부위 굴착량 증가의 문제점을 유발하고, 내화피복 공사는 공사환경을 열악하게 함은 물론 공사비 증대의 요인이 된다. 따라서 본 연구는 SPS 공법의 문제점을 개선한 모듈화된 철골철근 복합 구조시스템(modularized hybrid structure system)을 제안하는 것을 목적으로 한다. 제안된 공법은 구성원리와 함께 실험을 통하여 구조적 성능을 검증되고 다양한 공사조건을 만족시키는 시공성능이 분석된다.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF METAL-CERAMIC VERSUS COMPOSITE RESIN-VENEERED METAL CROWNS IN CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS UNDER VERTICAL COMPRESSIVE LOAD

  • Pae, Ahran;Jeon, Kyung-A;Kim, Myung-Rae;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.295-302
    • /
    • 2007
  • Statement of problem. Fracture of the tooth-colored superstructure material is one of the main prosthetic complications in implant-supported prostheses. Purpose. The purpose of this in vitro study was to compare the fracture strength between the cement-retained implant-supported metal-ceramic crowns and the indirect composite resinveneered metal crowns under the vertical compressive load. Material and methods. Standard implants of external type (AVANA IFR 415 Pre-mount; Osstem Co., Busan, Korea) were embedded in stainless steel blocks perpendicular to their long axis. Customized abutments were fabricated using plastic UCLA abutments (Esthetic plastic cylinder; Osstem Co., Busan, Korea). Thirty standardized copings were cast with non-precious metal (Rexillium III, Pentron, Walling ford, Conn., USA). Copings were divided into two groups of 15 specimens each (n = 15). For Group I specimens, metal-ceramic crowns were fabricated. For Group II specimens, composite resin-veneered (Sinfony, 3M-ESPE, St. Paul, MN, USA) metal crowns (Sinfony-veneered crowns) were fabricated according to manufacturer's instructions. All crowns were temporary cemented and vertically loaded with an Instron universal testing machine (Instron 3366, Instron Corp., Norwood, MA, USA). The maximum load value (N) at the moment of complete failure was recorded and all data were statistically analyzed by independent sample t-test at the significance level of 0.05. The modes of failure were also investigated with visual analysis. Results. The fracture strength of Sinfony-veneered crowns ($2292.7{\pm}576.0N$) was significantly greater than that of metal-ceramic crowns ($1150.6{\pm}268.2N$) (P < 0.05). With regard to the failure mode, Sinfony-veneered crowns exhibited adhesive failure, while metal-ceramic crowns tended to fracture in a manner that resulted in combined failure. Conclusion. Sinfony-veneered crowns demonstrated a significantly higher fracture strength than that of metal-ceramic crowns in cement-retained implant-supported prostheses.

UHPC 충전형 상현재를 활용한 트러스 데크플레이트 시스템 시공단계 구조성능 평가 (Structural Performance of a New Truss Deckplate System with UHPC Infilled Top Chords in Construction Stage)

  • 손홍준;김영호;김대진
    • 한국전산구조공학회논문집
    • /
    • 제33권2호
    • /
    • pp.137-144
    • /
    • 2020
  • 본 논문에서는 시공단계에서 서포트가 필요 없는 UHPC 충전형 상현재를 활용한 트러스 데크플레이트 시스템을 제안하고자 한다. 제안된 시스템은 기존의 시스템과 동일한 절대 층고를 유지하면서 증대된 강성과 강도를 보유하며 효과적으로 처짐을 제어한다. 제안된 시스템 및 기존의 시스템의 구조 성능을 평가하기 위해 4.6m의 순 스팬을 갖는 5개의 실험체를 제작하였고 점진적으로 하중을 증가시키며 4점 휨 실험을 수행하였다. 실험을 토대로 실험체별 하중-처짐 그래프를 도출하였고 변수에 따른 비교 및 분석을 진행하였다. 그리고 실험을 기준으로 수행한 비선형 3차원 유한요소해석결과와의 비교를 진행하였다. 비교 및 분석 결과, 기존의 트러스 데크플레이트를 제외한 모든 실험체들이 시공단계 하중에서 건축구조설계기준 및 강구조설계기준에서 제한하는 처짐 기준을 만족하였으며, 실험과 유한요소해석의 결과가 서로 유사한 것을 확인하였다.

Effect of Retained Pre-construction Primer on the Corrosion Protection Properties of Epoxy Coatings

  • Lee, Chul-Hwan;Shin, Chil-Seok;Lee, Ho-Il;Chung, Mong-Kyu;Baek, Kwang-Ki
    • Corrosion Science and Technology
    • /
    • 제6권5호
    • /
    • pp.219-226
    • /
    • 2007
  • Pre-construction primer (PCP), or shopprimer, have been applied to steel plates to control temporary corrosion during ship fabrication. For surface preparation at ship block stage, in common shipyard practices, welding beads, burnt and rusted areas shall be blasted or power tool cleaned and the contamination such as zinc salt shall be removed with blasting or power tool. Whereas, the sound film of PCP needs not to be removed or roughened as the paint having good compatibility with PCP is used for the first coat. In many cases, however, full blasting or sweep blasting on the sound PCP treated block assemblies was requested. There still has been argument about the legitimacy of this practice, thus, it is critical to evaluate the quality of the coating system applied on the sound PCP retained condition, comparing with the one applied on the full blasted or sweep blasted condition. In this study, two different epoxy systems for water ballast tank were applied on the surfaces with sound PCP condition, full blasted condition, and sweep blasted condition. Coating performances such as durability, anti-corrosion, cathodic disbondment resistance were evaluated. The test results clearly indicated that the sound film of PCP needed not to be removed or roughened as the paint having good compatibility with PCP based on inorganic zinc silicate.