• 제목/요약/키워드: Temporary prosthesis

검색결과 61건 처리시간 0.021초

상악 전치부 결손이 발음에 미치는 영향에 관한 연구 (A STUDY OF THE INFLUENCE ON PHONATION WHEN MAXILLARY ANTERIOR TEETH ARE MISSING)

  • 노창섭;최대균;우이형;최부병
    • 대한치과보철학회지
    • /
    • 제30권3호
    • /
    • pp.338-360
    • /
    • 1992
  • This study was performed to investigate the phonetic alterations with upper anterior teeth were missing. To compare the changes of the phonations, before and after insertion of the temporary prosthesis, six subjects who lost their upper anterior teeth were selected (2-male, 4-female). Tested sounds (/ga(가), na(나), da(다), ra(라), sa(사), ja(자), cha(차), ta(타), pa(파), ha(하), gi(기), ni(니), di(디), ri(리), si(시), jl(지), chi(치), ti(티), pi(피), hi(히), seu(스), se(세), so(소), su(수)/were programmed into an IBM AT with and without temporary prosthesis. These experiments were analyzed by formants, consonants durations, and energy level changes with an LSI speech work station program. During the pronunciation of the tested sounds (with and without temporary prosthesis), mandibular movements were recorded to a Mandibular Kinesiogram and analyzed . The findings led to the following conclusions: 1. Objective differences could not be found. However, in every informant, subjective improvement could be noticed. 2. There were no persistant correlations of the formant's changes. And in every informant, phonetic changes were variable. 3. There were various changes of the consonant durations in every informant. By and large, those of /si(시), jl(지), chi(치), Pi(피), hi(히)/ were longer than other tested sounds. After insertion of the prosthesis, durations were shorter. Consonants with /i(ㅣ)/ were longer than with /a(ㅏ)/, with or without prosthesis. 4. With and without temporary prosthesis, mandibular movements were various in the frontal view. Mandibular movements showed lateral deviations, and mandibular positions with /si(시), ji(지), ti(티), seu(스), hi(히)/ were nearer to the mandibular rest position. 5. The kinds of temporary prosthesis and conditions of the missing teeth influenced every informant variously, so there were no correlation between informants. 6. Energy levels increased in all tested sounds with a fixed temporary prosthesis. And, there were no differences between before and after insertion of a removable temporary prosthesis. However, sibilant sounds, and consonants with /i(ㅣ)/ showed a little increased energy level.

  • PDF

원내에서 5축 밀링기로 가공한 PMMA temporary crown의 다양한 임상적 활용

  • 서상진
    • 대한심미치과학회지
    • /
    • 제26권2호
    • /
    • pp.68-83
    • /
    • 2017
  • 치과용 CAD/CAM이 점차 보급됨에 따라, 사용할 수 있는 material의 종류와 활용할 수 있는 범위도 늘어나고 있다. 치과용 캐드캠의 가장 큰 장점은 한번의 방문으로 최종 보철물을 제작 할 수 있다는 점인데, 지르코니아나 복잡한 심미 보철의 경우 하루만에 제작하기 힘든 경우가 많다. 이러한 경우 임시치관용 PMMA 재료를 사용하여, 환자에게 심미성과 기능성을 가진 임시치관을 제공할 수 있으며 최종보철물에 대한 test crown이나 template등으로 활용할 수 있다. 그리고 원내에서 5축 밀링기로 가공한다면 임시치관을 빠른 시간에 큰 범위까지 정밀하게 제작할 수 있다. 이 글에서는 원내에서 가공하는 PMMA 임시치관의 다양한 활용과 임상증례에 대해 살펴보고자 한다.

임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례 (Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report)

  • 신석현;박찬익;강세하;문지은;오민석;박철민;전우진;한성구;김선재;최수진
    • 대한치과보철학회지
    • /
    • 제61권3호
    • /
    • pp.245-256
    • /
    • 2023
  • 임플란트 고정성 보철물 제작 시 디지털 시스템을 이용하여 수복할 때, 3차원적인 임플란트 위치의 구내 스캔과 임시 의치 혹은 임시 보철물 장착 후 구내 스캔을 이용한 이중 디지털 스캐닝(double digital scanning) 기법이 필요하다. 구내 스캔 시, 스캔 바디를 안정적인 랜드마크로 이용하면 다지털 인상의 정확도 향상과 기공과정이 효율적이고 단순화될 수 있다. 본 증례는 완전 디지털 시스템을 활용하여 맞춤형 치과용 임플란트 지대주 및 임시 보철물, 최종 보철물을 계획하고 제작하였다. 임플란트 식립 후, 임플란트에 체결한 구내 스캔 바디와 임시 의치 조직면에 인기 된 구내 스캔 바디의 스캔 영역을 중첩하였다. 중첩된 파일에서 임시 의치의 수직 고경에 맞는 맞춤형 치과용 임플란트 지대주와 임시 보철물을 제작하여 환자에게 시적 하였고, 임시 보철물을 토대로 최종 보철물을 제작하였다. 임시 의치 제작 시 설정한 수직 고경, 중심위 등을 최종 보철물까지 활용하여 기능 및 심미적으로 만족할 만한 결과를 얻어 이를 보고하고자 한다.

변형된 임플란트 임시 지대주의 물성에 대한 연구 (The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment)

  • 양병덕;윤태호;최운재;박주미
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

상하악 완전 무치악 환자에서 임시 보철물 스캔을 이용한 일체형 임플란트 지지 고정성 보철물 수복 증례 (Fabrication of definitive complete-arch implant-supported fixed prosthesis in upper and lower completely edentulous patient using temporary prosthesis scan: a case report)

  • 정승미;손현락;최강덕;최병호
    • 대한치과보철학회지
    • /
    • 제62권3호
    • /
    • pp.243-252
    • /
    • 2024
  • 상하악 완전 무치악 환자에서 임플란트 지지 고정성 최종 보철물을 제작할 때 환자의 수직 고경, 악간관계, 구강내에 식립된 임플란트와 임플란트에 연결된 지대주, 그리고 잇몸 형태에 관한 정확한 정보의 체득이 중요하다. 본 증례에서는 임시 보철물을 통해서 이러한 정보들을 채득하여 최종 보철물을 제작하였다. 임시 보철물을 구강 밖에서 스캔하여 스캔의 효율성을 높였고, 스캔 때 임시 보철물의 양측 후방 부위를 연결하는 스캔지그를 사용하여 스캔의 정밀도를 향상시켰다. 본 증례에서는 이와 같은 디지털 기술을 활용하여 심미적, 기능적으로 만족할 만한 임상적 결과를 얻었기에 이를 보고하는 바이다.

치과기공사국가시험 문항개발기준안연구 (Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician)

  • 이덕혜;정인성;한창식
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF

비인강폐쇄부전 환자의 언어교정을 위해 발음 보조장치를 이용한 증례 (The Use of a Temporary Speech Aid Prosthesis to Treat Speech in Velopharyngeal Insufficiency (VPI))

  • 김은주;고승오;신효근;김현기
    • 음성과학
    • /
    • 제9권4호
    • /
    • pp.3-14
    • /
    • 2002
  • VPI occurs when the velum and lateral and posterior pharyngeal wall fail to separate the nasal cavity from the oral cavity during deglutition and speech. There are a number of congenital and acquired conditions which result in VPI. Congenital conditions include cleft palate, submucous cleft palate and congenital palatal insufficiency (CPI). Acquired conditions include carcinoma of the palate or pharynx and neurologic disorders. The speech characteristics of VPI is characterized by hypernasality, nasal air emission, decreased intraoral air pressure, increased nasal air flow, decreased intelligibility. VPI can be treated with various methods that include speech therapy, surgical procedures to reduce the velopharyngeal gap, speech aid prosthesis, and combination of surgery and prosthesis. This article describes four cases of VPI treated by speech aid prosthesis and speech therapy with satisfactory result.

  • PDF

세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가 (Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time)

  • 배지현;최재원
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.

Three-dimensional printing of temporary crowns with polylactic acid polymer using the fused deposition modeling technique: a case series

  • Eun-Kyong Kim;Eun Young Park;Sohee Kang
    • Journal of Yeungnam Medical Science
    • /
    • 제40권3호
    • /
    • pp.302-307
    • /
    • 2023
  • With recent developments in digital dentistry, research on techniques and materials for three-dimensional (3D) printing is actively underway. We report the clinical applications and outcomes of 3D printing of temporary crowns fabricated with polylactic acid (PLA) using a fused deposition modeling (FDM) printer. Five participants were recruited from among patients scheduled to be treated with a single full-coverage crown at a dental clinic in a university medical center from June to August 2022. We used 3D-printed crowns fabricated with PLA using an FDM printer as temporary crowns and were assessed for discomfort, fracture, and dislodging. The 3D-printed temporary crowns were maintained without fracture, dislodging, or discomfort until the permanent prosthesis was ready. The average time required for printing the temporary crowns was approximately 7 minutes. The 3D printing of temporary crowns with PLA using an FDM printer is a convenient process for dentists. However, these crowns have some limitations, such as rough surface texture and translucency; therefore, the 3D printing process should be improved to produce better prostheses.

스트레스 없는 인상 채득

  • 이승규
    • 대한심미치과학회지
    • /
    • 제26권1호
    • /
    • pp.24-38
    • /
    • 2017
  • 치과 임상에서 보철 과정은 1) 치아 삭제 2) 임시 수복물 제작 3) 포스트와 코어 4) 인상채득 5) 최종 보철물 합착의 순서로 진행된다. 보철 과정의 마지막이 정확한 적합과 교합 관계를 갖는 최종 보철물을 환자의 지대치의 적합시키는 과정이다. 그런데, 이 최종 보철물은 진료실에서 만들어지는 것이 아니라, 치과 기공실에서 만들어져서 약간의 시간차를 두고 진료실로 오게 된다. 진료실에서 환자의 구강 내 정보를 기공실로 전달하는 유일한 매체는 인상체이다. 그런데 이 과정에서 수 많은 오차가 발생된다. 치과 의사와 치과 기공사는 이 오차를 줄이기 위해 원인을 파악하고 정확한 보철물 제작을 위해 노력해야 한다.