• 제목/요약/키워드: Temporary fixture system

검색결과 3건 처리시간 0.018초

임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향 (Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants)

  • 윤보혁;신현모;윤미정;허중보;정창모;강은숙
    • 대한치과의사협회지
    • /
    • 제53권9호
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

즉시 Frialit-2 implant 식립, 즉시 임시치관 제작 그리고 IPS Empress 2 crown을 이용한 상악중절치의 심미적 수복 (Esthetic reconstruction of upper central incisor using immediate Frialit-2 implant placement, immediate temporary crown fabrication and IPS Empress 2 crown)

  • 김유리;오상천
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.43-48
    • /
    • 2003
  • During the past several years, significant advances have occurred in the utilization of osseointegrated implants for the treatment of partially edentulous patients. One of the biggest purposes for treating of these patients is the high demand for improved esthetics, especially in the anterior region. For this esthetics, the new trend in dental implants is the immediate placement and immediate superstructure fabrication. The refined surgical technique, the skillful soft tissue management, and the proper prosthetic coordination are the main factors to achieve natural looking of implant supported prosthesis. The customized provisional restoration and the customized impression coping are recommended for the optimal peri-implant soft tissue contour. The basic concept of Frialit 2 system was the immediate replacement of a tooth with root-analog fixture after extraction. This system guarantees an ideal result in function and esthetics. The ceramic abutment system offers improved quality in the respect of esthetics, fitness, translucency, and biocompatibility. In this clinical report, the final restoration made with IPS Empress 2 crown on the CeraBase abutmen of Frialit 2 system allowed the reproduction of the natural vitality of tooth and adjacent gingiva.

FCM 교량 가설 공법에서 주두부의 기울음 특성 (The Inclination Characteristics of PSC BOX in FCM Bridge Construction Method)

  • 강현억;박완신;장영일;김선우;윤현도
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권3호
    • /
    • pp.12-20
    • /
    • 2023
  • 본 연구에서는 영구 교좌장치가 설치되는 교량의 교각 상부에서 FCM에 의한 상부공 시공에 주로 적용하고 있는 "내부 프리스트레싱 긴장재에 의한 임시 고정시스템"에서 강봉에 도입한 긴장력의 변화와 주두부의 기울음 특성을 분석하여 안정성 확보 방안에 대한 기초자료를 제시하였다. 상기 시스템은 시공 중 불균형 모멘트에 의하여 발행하는 상향력에 저항하기 위하여 교각과 교각 상부의 PSC BOX 내부에 연직으로 강봉을 설치한 후 상부에서 인장 및 정착하기 때문에, 그 동안 강봉에 도입한 긴장력의 변화와 주두부의 기울음 정도를 확인하기 어려웠다. 따라서, 강봉의 길이 변화 및 주두부 변위에 대한 계측 및 분석은 미세 측정이 가능한 FBG 센서를 활용하여 각 세그먼트 진행의 전후에 수행하였다. 강봉의 계산 인장력과 잔존 인장력을 비교한 결과 안전율은 모든 교량에서 저하하였다. 그 원인은 주로 강봉의 정착 과정에서부터 1세그먼트 완료까지의 초기 긴장력 손실로 확인되어 이에 대한 대책을 제시하였다. 주두부의 미세 기울음 특성을 분석한 결과 안전율이 충분히 확보된 교량에서도 세그먼트의 진행에 따라 미세 기울음이 증가되는 양상을 보였으며, 세그먼트 진행 단계별로 콘크리트 타설 전,후의 차이도 뚜렸하게 확인되었다. 또한, 모든 교량에서 미세 기울음의 증가는 강봉의 긴장력 손실과 밀접한 관계를 보이며 기울음 측면과 반대 측면의 응력 감소가 더욱 크게 나타났다. 이러한 현상의 원인은 불균형모멘트에 의하여 기울음 측면과의 반대 측면의 강봉에 상향 인장력이 발생하여 강봉의 응력 차이를 유발시킨 때문으로 판단된다.