• 제목/요약/키워드: Temporal Deceleration

검색결과 4건 처리시간 0.017초

시간에 대해 감속하는 난류 파이프 유동에 관한 연구 (Turbulence in temporally decelerating pipe flows)

  • 정원관;이재화
    • 한국가시화정보학회지
    • /
    • 제14권1호
    • /
    • pp.46-50
    • /
    • 2016
  • Direct numerical simulations (DNSs) of turbulent pipe flows with temporal deceleration were performed to examine response of the turbulent flows to the deceleration. The simulations were started with a fully-developed turbulent pipe flow at the Reynolds number, $Re_D=24380$, based on the pipe radius and the laminar centerline velocity, and three different constant temporal decelerations were applied to the initial flow with varying dU/dt = -0.001274, -0.00625 and -0.025. It was shown that the mean flows were greatly affected by temporal decelerations with downward shift of log law, and turbulent intensities were increased in particular in the outer layer, compared to steady flows at a similar Reynolds number. The analysis of Reynolds shear stress showed that second- and fourth-quadrant Reynolds shear stresses were increased with the decelerations, and the increase of the turbulence was attributed to enhancement of outer turbulent vortical structures by the temporal decelerations.

슬러그 2상유동에서 전류형식 전자기유량계 수치적 신호예측 및 보정 (Numerical Signal Prediction and Calibration Using the Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Slug Flow)

  • 안예찬;오병도;김종록;김무환;강덕홍
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.671-686
    • /
    • 2005
  • The transient nature and complex geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et al.). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. The velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method, and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for simulating slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are proposed for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

슬러그류 액상속도 측정용 전류형식 전자기유량계 개발 (Development of a Current-Type Electromagnetic Flowmeter to Obtain the Liquid Mean Velocity in Two-Phase Slug Flow)

  • 강덕홍;안예찬;김종록;오병도;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1951-1956
    • /
    • 2004
  • The transient nature and complex flow geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et $al.^{(1)}$). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. To do this, the velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for the simulated slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are required for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

  • PDF

LIEE와 Mie 산란 방법을 이용한 직분식 가솔린 엔진의 스월 및 슬릿 인젝터의 분무 특성 (The Spray Characteristics of Swirl and Slit Injector to DISI Engine Using LIEF and Mie-scattering Method)

  • 이기형;황규민;이창희
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.356-367
    • /
    • 2005
  • The spray characteristics of DISI injector have a great role in gasoline engine efficiency and emission. Thus, many researchers have studied to investigate the spray characteristics of swirl and slit injectors that are used in a DISI engine. In this study, we tried to provide spray parameters, which affect on the spray characteristics such as injection pressure, ambient pressure and ambient temperature. In addition, we calculated $t_{b}\;and\;t_{c}$ to investigate the break up mechanism of test injectors and obtained $C_{v}$ to evaluate the spray characteristics. As the ambient pressure increases in case of slit injector, $C_{v}$ decreases. The laser-induced exciplex fluorescence (LIEF) technique, which is based on spectrally resolved two-color fluorescent emissions, has applied to measure the liquid and vapor phases for on evaporating spray simultaneously. The TMPD/naphthalene proposed by Melton is used as a dophant to detect exciplex signal. The temporal and spatial distribution of liquid and vapor phases during the mixture formation process was measured by this technique. In the LIEF technique, the vapor phase is detected by the monomer fluorescence while the liquid phase is tracked by the exciplex fluorescence. From this experiment, we found that the spray area of the vapor phase is increased with elapsed time after injection and the area of liquid is decreased when the ambient pressure is 0.1MPa. However, the area tends to increase until the end of injection when the ambient pressure is 1.0MPa.