• Title/Summary/Keyword: Temperature-humidity index

Search Result 296, Processing Time 0.026 seconds

Effects of heat stress and rumen-protected fat supplementation on growth performance, rumen characteristics, and blood parameters in growing Korean cattle steers

  • Kang, Hyeok Joong;Piao, Min Yu;Park, Seung Ju;Na, Sang Weon;Kim, Hyun Jin;Baik, Myunggi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.6
    • /
    • pp.826-833
    • /
    • 2019
  • Objective: This study was performed to evaluate whether hot temperature and rumen-protected fat (RPF) supplementation affect growth performance, rumen characteristics, and serum metabolites in growing stage of Korean cattle steers. Methods: Twenty Korean cattle steers ($230.4{\pm}4.09kg$ of body weight [BW], $10.7{\pm}0.09months$ of age) were divided into a conventional control diet group (n = 10) and a 0.8% RPF supplementation group (n = 10). Steers were fed 1.5% BW of a concentrate diet and 4 kg of tall fescue hay for 16 weeks (July 10 to August 6 [P1], August 7 to September 3 [P2], September 4 to October 1 [P3], October 2 to 30 [P4], of 2015). Results: The mean temperature-humidity index (THI) was higher (p<0.001) in P1 (76.8), P2 (76.3), and P3 (75.9) than in P4 (50.9). The mean THI of P1-3 were within the alert heat stress (HS) category range according to previously reported categories for feedlot cattle, and the mean THI of P4 was under the thermo-neutral range. Neither month nor RPF supplementation affected (p>0.05) average daily gain and gain to feed ratio. Month and RPF supplementation affected concentrations of glucose, albumin, and high-density lipoprotein (HDL); those of albumin and glucose tended to decrease (p<0.10), but HDL concentration increased (p<0.01) by RPF supplementation. Neither month nor RPF affected (p>0.05) ruminal pH, $NH_3-N$, and volatile fatty acid concentrations, whereas the C2:C3 ratio was affected (p<0.05) by month. Conclusion: Korean cattle may not have been significantly affected by alert HS during the growing stage. Growth performance was higher during hotter months, although some changes in blood metabolites were observed. The RPF supplementation affected some blood lipids and carbohydrate metabolites but did not affect growth performance.

Improvement and Validation of Convective Rainfall Rate Retrieved from Visible and Infrared Image Bands of the COMS Satellite (COMS 위성의 가시 및 적외 영상 채널로부터 복원된 대류운의 강우강도 향상과 검증)

  • Moon, Yun Seob;Lee, Kangyeol
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.420-433
    • /
    • 2016
  • The purpose of this study is to improve the calibration matrixes of 2-D and 3-D convective rainfall rates (CRR) using the brightness temperature of the infrared $10.8{\mu}m$ channel (IR), the difference of brightness temperatures between infrared $10.8{\mu}m$ and vapor $6.7{\mu}m$ channels (IR-WV), and the normalized reflectance of the visible channel (VIS) from the COMS satellite and rainfall rate from the weather radar for the period of 75 rainy days from April 22, 2011 to October 22, 2011 in Korea. Especially, the rainfall rate data of the weather radar are used to validate the new 2-D and 3-DCRR calibration matrixes suitable for the Korean peninsula for the period of 24 rainy days in 2011. The 2D and 3D calibration matrixes provide the basic and maximum CRR values ($mm\;h^{-1}$) by multiplying the rain probability matrix, which is calculated by using the number of rainy and no-rainy pixels with associated 2-D (IR, IR-WV) and 3-D (IR, IR-WV, VIS) matrixes, by the mean and maximum rainfall rate matrixes, respectively, which is calculated by dividing the accumulated rainfall rate by the number of rainy pixels and by the product of the maximum rain rate for the calibration period by the number of rain occurrences. Finally, new 2-D and 3-D CRR calibration matrixes are obtained experimentally from the regression analysis of both basic and maximum rainfall rate matrixes. As a result, an area of rainfall rate more than 10 mm/h is magnified in the new ones as well as CRR is shown in lower class ranges in matrixes between IR brightness temperature and IR-WV brightness temperature difference than the existing ones. Accuracy and categorical statistics are computed for the data of CRR events occurred during the given period. The mean error (ME), mean absolute error (MAE), and root mean squire error (RMSE) in new 2-D and 3-D CRR calibrations led to smaller than in the existing ones, where false alarm ratio had decreased, probability of detection had increased a bit, and critical success index scores had improved. To take into account the strong rainfall rate in the weather events such as thunderstorms and typhoon, a moisture correction factor is corrected. This factor is defined as the product of the total precipitable waterby the relative humidity (PW RH), a mean value between surface and 500 hPa level, obtained from a numerical model or the COMS retrieval data. In this study, when the IR cloud top brightness temperature is lower than 210 K and the relative humidity is greater than 40%, the moisture correction factor is empirically scaled from 1.0 to 2.0 basing on PW RH values. Consequently, in applying to this factor in new 2D and 2D CRR calibrations, the ME, MAE, and RMSE are smaller than the new ones.

Effect of heat stress on growth performance and physiological changes of pigs in commercial farm (고온스트레스가 일반 양돈농가의 돼지 생산성 및 생리 변화에 미치는 영향)

  • Oh, Seo Young;Jeong, Yong Dae;Kim, Doo Wan;Min, Ye Jin;Yu, Dong Jo;Kim, Ki Hyun;Kim, Young Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.130-139
    • /
    • 2017
  • This study investigated the effect of heat stress on the performance and blood characteristics in commercial pig farms. A total of 180 growing pigs and 180 finishing pigs were assigned to two treatments consisting of thermal-neutral period(TNP) and high-temperature period(HTP) with three replications in floor pen, respectively. Feeding trials in the TNP and HTP were individually performed in autumn and summer seasons, respectively. Temperature-humidity index(THI) was calculated by temperature and humidity. Performance and physiological responses were identified per growth stages and feeding trial. Average temperature and THI were $16.8^{\circ}C$ and 61.4 at the TNP, and $25^{\circ}C$ and 74.3 at the HTP, respectively. Growing pigs in HTP exhibited lower BW, ADG and ADFI than in TNP(p<0.01). Similarly, finishing pigs showed lower growth parameters in HTP than in TNP(p<0.01). Lymphocytes and neutrophils of growing pigs were lower in HTP than in TNP(p<0.05). The serum T-PRO and NEFA in finishing pigs were higher in HTP than in TNP(p<0.05). In HTP, finishing pigs had higher cortisol levels than in TNP. Therefore, HTP can negatively influence growth performance and nutritional metabolism in pigs. Our results may provide useful information for developing feeding programs and diets to control heat stress for swine farms.

Analysis of Human Thermal Environment in an Apartment Complex in Late Spring and Summer - Magok-dong, Gangseo-gu, Seoul- (아파트 단지의 늦봄·여름철 인간 열환경 분석 - 서울특별시 강서구 마곡동 -)

  • Park, Sookuk;Hyun, Cheolji;Kang, Hoon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.1
    • /
    • pp.68-77
    • /
    • 2022
  • The human thermal environment in an apartment complex located in Seoul was quantitatively analyzed to devise methods to modify human heat-related stresses in landscape and urban planning. Microclimatic data (air temperature, relative humidity, wind speed, and short- and long-wave radiation) were collected at 6 locations [Apt-center, roof (cement), roof (grass), ground, playground, and a tree-lined road] in the late spring and summer, and the data were used to estimate the human thermal sensation, physiological equivalent temperature (PET) and universal thermal climate index (UTCI). As a result, the playground location had the highest thermal environment, and the roof (grass) location had the lowest. The mean difference between the two locations was 0.8-1.1℃ in air temperature, 1.8-4.0% in relative humidity, and 7.5-8.0℃ in mean radiant temperature. In open space locations, the wind speed was 0.4-0.5 ms-1 higher than others. Also, a wind tunnel effect happened at the Apt-center location during the afternoon. For the human thermal sensation, PET and UTCI, the mean differences between the playground and roof (grass) locations were: 5.2℃ (Max. 11.7℃) in late spring and 5.4℃ (Max. 18.1℃) in summer in PET; and 3.0℃ (Max. 6.1℃) in late spring and 2.6℃ (Max. 9.8℃) in summer in UTCI. The mean differences indicated a level change in PET and 1/2 level in UTCI, and the maximum differences showed greater changes, 2-3 levels in PET, and 1-1.5 levels in UTCI. Moreover, the roof (grass) location gave 4.6℃ PET reduction and a 2.5℃ UTCI reduction in late spring, and a 4.4℃ PET reduction and a 2.0℃ UTCI reduction in the summer when compared with the roof (cement) location, which results in a 2/3 level change in PET and a 1/3 level in UTCI. Green infrastructure locations [roof (grass), ground, and a tree-lined road] were not statistically significant in the reduction of PET and UTCI in thermal environment modifying effects. The implementation of green infrastructure, such as rooftop gardens, grass pavement, and street tree planting, should be adopted in landscape planning and be employed for human thermal environment modification.

Effects of Local Climatic Conditions on the Early Growth in Korean White Pine (Pinus koraiensis Sieb. et Zucc.) Stands -Relation between Annual Increment and Local Climatic Conditions- (지역별 잣나무 초기생장에 미치는 미기후의 영향 - 연년생장과 미기후와의 관계-)

  • Chon Sang- Keun;Shin Man Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.1
    • /
    • pp.41-51
    • /
    • 1999
  • This study was conducted to investigate the effects of local climatic conditions on the annual increment of Korean white pine planted in Gapyung and Yaungdong. For this, stand variables such as mean DBH, mean height, basal area per hectare, and volume per hectare by stand age were measured and summarized for each locality. Based on these statistics, annual increments for 8 years from stand age 10 to 18 were calculated for each of stand variables. A topoclimatological technique which makes use of empirical relationships between the topography and the weather in study sites was applied to produce normal estimates of monthly mean, maximum, minimum temperatures, relative humidity, precipitation, and hours of sunshine. Then, the yearly climatic variables from 1990 to 1997 for each study site were derived from the spatial interpolation procedures based on inverse- distance weighting of the observed deviation from the climatic normals at the nearest 11 standard weather stations. From these estimates, 17 weather variables such as warmth index, coldness index, index of aridity etc., which affect the tree growth, were computed on yearly base for each locality. The deviations of measured annual increments from the expected annual increments for 8 years based on yield table of Korean white pine were then correlated with and regressed on the yearly weather variables to examine effects of local climatic conditions on the growth. Gapyung area provides better conditions for the growth of Korean white pine in the early stage than Youngdong area. This indicates that the conditions such as low temperature, high relative humidity, and large amount of precipitation provide favor environment for the early growth of Korean white pine. A ccording to the correlation and regression an analysis using local climatic conditions and annual increments, the growth pattern of Gapyung area corresponds to this tendency. However, it was found that the relationship between annual increments and local climatic conditions in Youngdong area shows different tendency from Gapyung. These results mean that the yearly growth pattern could not sufficiently be explained by climatic conditions with high variance in yearly weather variables. In addition, the poor growth in Youngdong area might not only be affected by climatic conditions, but also by other environmental factors such as site quality.

  • PDF

The Effects of Pergola Wisteria floribunda's LAI on Thermal Environment (그늘시렁 Wisteria floribunda의 엽면적지수가 온열환경에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.115-125
    • /
    • 2017
  • This study was to investigate the user's thermal environments under the pergola($L\;7,200{\times}W\;4,200{\times}H\;2,700mn$) covered with Wisteria floribunda(Willd.) DC. according to the variation of leaf area index(LAI). We carried out detailed measurements with two human-biometeorological stations on a popular square Jinju, Korea($N35^{\circ}10^{\prime}59.8^{{\prime}{\prime}}$, $E\;128^{\circ}05^{\prime}32.0^{{\prime}{\prime}}$, elevation: 38m). One of the stations stood under a pergola, while the other in the sun. The measurement spots were instrumented with microclimate monitoring stations to continuously measure air temperature and relative humidity, wind speed, shortwave and longwave radiation from the six cardinal directions at the height of 0.6m so as to calculate the Universal Thermal Climate Index(UTCI) from $9^{th}$ April to $27^{th}$ September 2017. The LAI was measured using the LAI-2200C Plant Canopy Analyzer. The analysis results of 18 day's 1 minute term human-biometeorological data absorbed by a man in sitting position from 10am to 4pm showed the following. During the whole observation period, daily average air temperatures under the pergola were respectively $0.7{\sim}2.3^{\circ}C$ lower compared with those in the sun, daily average wind speed and relative humidity under the pergola were respectively 0.17~0.38m/s and 0.4~3.1% higher compared with those in the sun. There was significant relationship in LAI, Julian day number and were expressed in the equation $y=-0.0004x^2+0.1719x-11.765(R^2=0.9897)$. The average $T_{mrt}$ under the pergola were $11.9{\sim}25.4^{\circ}C$ lower and maximum ${\Delta}T_{mrt}$ under the pergola were $24.1{\sim}30.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average $T_{mrt}$ compared with those in the sun and was expressed in the equation $y=0.0678{\ln}(x)+0.3036(R^2=0.9454)$. The average UTCI under the pergola were $4.1{\sim}8.3^{\circ}C$ lower and maximum ${\Delta}UTCI$ under the pergola were $7.8{\sim}10.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average UTCI compared with those in the sun and were expressed in the equation $y=0.0322{\ln}(x)+0.1538(R^2=0.8946)$. The shading by the pergola covered with vines was very effective for reducing daytime UTCI absorbed by a man in sitting position at summer largely through a reduction in mean radiant temperature from sun protection, lowering thermal stress from very strong(UTCI >$38^{\circ}C$) and strong(UTCI >$32^{\circ}C$) down to strong(UTCI >$32^{\circ}C$) and moderate(UTCI >$26^{\circ}C$). Therefore the pergola covered with vines used for shading outdoor spaces is essential to mitigate heat stress and can create better human thermal comfort especially in cities during summer. But the thermal environments under the pergola covered with vines during the heat wave supposed to user "very strong heat stress(UTCI>$38^{\circ}C$)". Therefore users must restrain themselves from outdoor activities during the heat waves.

Effect of Floor Space Allowance on Pig Productivity across Stages of Growth: A Field-scale Analysis

  • Lee, Joon H.;Choi, Hong L.;Heo, Yong J.;Chung, Yoon P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.5
    • /
    • pp.739-746
    • /
    • 2016
  • A total of 152 pig farms were randomly selected from the five provinces in South Korea. During the experiment, the average temperature and relative humidity was $24.7^{\circ}C$ and 74% in summer and $2.4^{\circ}C$ and 53% in winter, respectively. The correlation between floor space allowance (FSA) and productivity index was analyzed, including non-productive sow days (NPD), number of weaners (NOW), survival rate (SR), appearance rate of A-grade pork (ARA), and days at a slaughter weight of 110 kg (d-SW) at different growth stages. The objectives of the present study were i) to determine the effect of FSA on the pig productivity index and ii) to suggest the minimum FSA for pigs based on scientific baseline data. For the pregnant sow, NPD could be decreased if pregnant sows were raised with a medium level (M) of FSA (3.10 to $3.67m^2/head$) while also keeping the pig house clean which improves hygiene, and operating the ventilation system properly. For the farrowing sows, the NOW tended to decrease as the FSA increased. Similarly, a high level of FSA (H) is significantly negative with weaner SR of farrowing sows (p-value = 0.017), indicating this FSA tends to depress SR. Therefore, a FSA of 2.30 to $6.40m^2/head$ (very low) could be appropriate for weaners because a limited space can provide a sense of security and protection from external interruptions. The opposite trend was observed that an increase in floor space (> $1.12m^2/head$ leads to increase the SR of growing pigs. For the fattening pigs, H level of FSA was negatively correlated with SR, but M level of FSA was positively correlated with SR, indicating that SR tended to increase with the FSA of 1.10 to $1.27m^2/head$. In contrast, ARA of male fattening pigs showed opposite results. H level of FSA (1.27 to $1.47m^2/head$) was suggested to increase productivity because ARA was most affected by H level of space allowance with positive correlation ($R^2=0.523$). The relationship between the FSA and d-SW of fattening pigs was hard to identify because of the low $R^2$ value. However, the farms that provided a relatively large floor space (1.27 to $1.54m^2/head$) during the winter period showed d-SW was significantly and negatively affected by FSA.

Assessment of Indoor Air Quality and the Eye Symptom of Occupants in Newly-built Office Building after Planting Indoor Plants (신축사무실 내 식물 적용 후 재실자 안구 증상 및 실내공기질 평가)

  • Kim, Hyojin;Kim, Ho-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.265-274
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate relationship between worker's ophthalmoxerosis symptom and IAQ (Indoor Air Quality) variation after planting indoor plants at newly-built office building. Methods: We selected a new office building located in Sejong-si and occupants who work in the Office for study. The indoor air pollutant was investigated according to applying indoor plants. The indoor air quality of the new building was evaluated by measuring volatile organic compounds (VOCs), aldehydes, temperature and humidity. The level of dry eye symptoms was classified into normal, mild, moderate and severe by using the Ocular Surface Disease Index (OSDI). Results: There was VOCs' reduction effect according to placing indoor plants because the concentration of VOCs in newly-built government office (Sejong-si) was highly decreased when the indoor plants was placed at the office. The occupants' SBS (Sick Building Syndrome) symptoms score was gradually decreased in accordance with applying indoor plants. However, SBS symptoms score was increased when the office was not applied indoor plants. There was not statistical significance in workers' dry eye questionnaire results. Conclusions: There was reduction effect of indoor air pollutant in applied indoor plants office. Also, in case of questionnaire results of ophthalmoxerosis and SBS (Sick Building Syndrome) symptoms score were showed positive effect. This study is needed longer-term study because of complements of difference of individual sensitivity and there are some limitations due to field survey research.

The Spectral Characteristics of Climatological Variables over the Asian Dust Source Regions and its Association with Particle Concentrations in Busan (황사 발원지 기후자료의 시계열 특성과 부산지역 먼지 농도의 연관성 분석)

  • Son, Hye-Young;Kim, Cheol-Hee
    • Journal of the Korean earth science society
    • /
    • v.30 no.6
    • /
    • pp.734-743
    • /
    • 2009
  • In order to examine how climatological condition can influence on urban scale particulate air pollutants, single and cross spectrum analysis have been performed to daily mean concentrations of particulate matters ($PM_{10}$) in Busan together with the climatological variables over the Asian dust source regions. Single power spectrum analysis of $PM_{10}$ concentrations in Busan shows that, aside from the typical and well-known periodicities, 3-4 year of peak periodicity of power spectrum density was identified. In cross spectrum analysis, this 3-4 year periodicity is found to have a strong positive correlation with the wind speed and pressure, and negative with the temperature and relative humidity, which is rather consistent with both characteristics of air mass during the Asian dust event whose periodicities have been recorded inter-annually over the Korean urban cities. Over the Asian dust source regions, $PM_{10}$ vs. precipitation shows no significant periodicity from the time series of precipitation data, but the periodicity of EDI (Effective Drought Index) shows some interannual variabilities ranging from 2 to 4 years over the various source regions, suggesting that, rather than precipitation itself, the EDI could be more closely associated with the occurrence frequency of Asian dust and interannual variability of urban particle concentrations in Korean cities.

Application of Simplified Curing Unit for the Extension of Storage Life and Improvement of Physicochemical Quality of Sweet Potatoes during Long-term Storage (간이 큐어링 설비를 이용한 큐어링 처리가 장기간 저장 중 고구마의 품질 개선에 미치는 영향)

  • Song, Jeong-Hwa;Kim, Sung-Kyeom;Chun, Chang-Hoo
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.304-310
    • /
    • 2011
  • To evaluate the effect of curing treatment using a newly developed simplified curing unit (SCU) on the physicochemical quality of stored sweet potatoes was investigated for six months. The SCU consisting of a heater, an air circulation fan, exhaust fans, and a humidifying duct was installed in a cold storage room where the harvested sweet potatoes were stacked. During the six days of curing treatment, air temperature and relative humidity in the storage room were set at $32^{\circ}C$ and 90%, respectively. Physical and chemical properties of sweet potatoes were measured at 1-month intervals from the first day of storage. McKinney index showing the incidence and severity of decay was 0.83% in the curing treatment, while that of untreated control was 5.08% over the same storing period. Firmness, soluble solids content, and dry matter content in the cured sweet potatoes were greater than those of untreated control. Moreover, the changes of skin color in uncured potatoes occurred rapidly than cured one which showed delay of skin discoloration during the long-term storage. Results suggest that the SCU treatment improves the physicochemical quality of stored sweet potatoes and extends their storability. Therefore, the SCU can be effectively used for curing treatment of sweet potatoes with a relatively low cost.