• 제목/요약/키워드: Temperature-difference method

검색결과 1,624건 처리시간 0.03초

고온강재의 담금질 전열에 관한 연구 (A Study on the Heat Transfer of the High Temperature Metals in Quenching - The Latent Heat of Phase Transformation and Cooling Curves -)

  • 윤석훈
    • 수산해양기술연구
    • /
    • 제27권4호
    • /
    • pp.321-327
    • /
    • 1991
  • Experiments of quenching were made with cylindrical specimens of carbon steel S45C of diameters from 12 to 30mm were performed. The specimens were heated by electric furnace and quenched by immersion method. In order to analyze the temperature profile(cooling curves) of carbon steel including the latent heat of phase transformation, nonlinear heat conduction problem was calculated by the numerical method of inverse heat conduction problem using the apparent heat capacity method. The difference between the calculated and the experimented cooling curves was caused by the latent heat of phase transformation, and the effects of the latent heat were especially manifest at the cooling curves of center of specimens. The temperature and the quantity of the latent heat of phase transformation depend on the cooling speed at A sub(1) transformation point, and the region for cooling speed to become zero was caused by the latent heat of phase transformation.

  • PDF

Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

  • Seo, Mansu;Park, Hana;Yoo, DonGyu;Jung, Youngsuk;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권2호
    • /
    • pp.64-69
    • /
    • 2014
  • Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid propellant stored in space is proven with good measurement accuracy.

고융점 산화물에 대한 고온 증발 (High Temperature Vaporization of the High Melting Point Oxides)

  • 이홍림
    • 한국세라믹학회지
    • /
    • 제15권2호
    • /
    • pp.72-78
    • /
    • 1978
  • The vapor pressure of the high melting point oxides, MgO, $Cr_2O_3$, and $MgCr_2O_4$ were measured over the temperature range 1300 to 175$0^{\circ}C$ under vacuum <$10^{-5}$ torr by the Langmuir and the Knudsen method. The Langmuir vapor pressure was increased with elevating temperature and with increasing porosity of the specimen. The difference between the vapor preseures measured by the Langmuir and the Knudsen method was decreased with elevating temperature and the Langmuir vapor pressure finally reached the Knudsen vapor pressure at the melting point when extrapolated. The vapor pressure of other important oxides with high melting points, i.e., $Al_2O_3$, $ThO_2$, $Yb_2O_3$ and $Y_2O_3$ were cited from the references. The Langmuir and the Knudsen vapor pressure of these oxides also showed the same results, i.e., they showed the same value at their melting points.

  • PDF

병렬팽창 냉동시스템의 성능실험에 관한 실험적 연구 (An Experimental Study on the Performance Testing of Parallel Expansion Refrigeration System)

  • 구창대
    • 한국산업융합학회 논문집
    • /
    • 제14권2호
    • /
    • pp.79-85
    • /
    • 2011
  • This study has been experimented about refrigeration capacity difference. It has been used 3 method, Manual expansion valve, thermostatic expansion valve and capillary expansion valve, and tested under the same condition by using the performance testing of parallel expansion. In temperature change of the temperature room, thermostatic expansion valve method displayed the most lower temperature, $-18^{\circ}C$. In addition, the temperature, just before the expansion, also displayed the best result which was $4^{\circ}C$ lower than other expansion valve. In these results, it can be used for performance testing of parallel expansion refrigeration system.

마늘 재배적지분석을 위한 기온자료 공간보간기법 비교 (Comparison between Spatial Interpolation Methods of Temperature Data for Garlic Cultivation)

  • 김용완;홍석영;장민원
    • 한국농공학회논문집
    • /
    • 제53권5호
    • /
    • pp.1-7
    • /
    • 2011
  • The objective of this study is to decide a spatial interpolation method on temperature data for the suitability analysis of garlic cultivation. In Korea, garlic is the second most cultivated condiment vegetable after red pepper. Nowadays warm-temperate garlic faces potential shift of its arable area according to warmer temperature in the Korean Peninsula, and the change can be drawn with the precise temperature map derived from interpolation on point-measured data. To find the preferable interpolation method in cases of germination and vegetative period of the garlic, different approaches were tested as follows: Inverse Distance Weighted (IDW), Spline, Ordinary Kriging (OK), and Universal Kriging (UK). As a result, IDW and UK show the lowest root mean square errors as for the germination and vegetative seasons, respectively. However, statistically significant difference was not revealed among the applied methods regarding the germinating period. Eventually this will contribute to mapping the suitable lands for the cultivation of warm-temperate garlic reasonably.

공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법 (Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber)

  • 정은수
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

자동미분법과 Broyden 혼합법을 이용한 2차원 원통형상에서의 경계온도 역추정 (Inverse Boundary Temperature Estimation in a Two-Dimensional Cylindrical Enclosure Using Automatic Differentiation and Broyden Combined Method)

  • 김기완;김동민;백승욱
    • 대한기계학회논문집B
    • /
    • 제30권3호
    • /
    • pp.270-277
    • /
    • 2006
  • Inverse radiation problems were solved for estimating boundary temperature distribution in a way of function estimation approach in an axisymmetric absorbing, emitting and scattering medium, given the measured radiative data. In order to reduce the computational time fur the calculation of sensitivity matrix, automatic differentiation and Broyden combined method were adopted, and their computational precision and efficiency were compared with the result obtained by finite difference approximation.. In inverse analysis, the effects of the precision of sensitivity matrix, the number of measurement points and measurement error on the estimation accuracy had been inspected using quasi-Newton method as an inverse method. Inverse solutions were validated with the result acquired by additional inverse methods of conjugate-gradient method or Levenberg-Marquardt method.

A Heat Loss Comparison Between the Two Parabolic Fin Models Using Two Different Numerical Methods

  • Kim, K.T.;Kang, H.S.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제2권2호
    • /
    • pp.97-109
    • /
    • 1998
  • A comparison of the two dimensional heat loss, computed using the analytical method and the finite difference method in two models(i.e. one is a parabolic fin whose parabolic curves meet at the fin center line and the other is a transformed parabolic fin whose tip cuts vertically), is made assuming the analytical method is correct. For these methods, the root temperature and surrounding convection coefficients of these fins are assumed as constants. The results show that the relative errors of the heat loss between the two methods for the parabolic fin whose tip cuts vertically are smaller than those for the one whose tip does not cut. In case of Bi=0.01, the values of the heat loss obtained using a finite difference method are close to those values obtained using the analytical method for both models. The values of the heat loss from both models calculated by using the analytical method are almost the same for given range of non-dimensional fin length in case of Bi = 0.01 and 0.1.

  • PDF

외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정 (Investigation of Standard Error Range of Non-Contact Thermometer by Environment)

  • 김정은;박상웅;최혜경
    • 대한통합의학회지
    • /
    • 제8권4호
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험 (Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems)

  • 조용;권혁승;김성현;김영일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF