• Title/Summary/Keyword: Temperature transient

Search Result 1,150, Processing Time 0.025 seconds

A numerical study on the transient operation of high temperature heat pipe with a switching heat source (열원이 바뀌는 고온용 히트파이프의 천이 과정 동작에 관한 수치적 연구)

  • Park, Jong-Heung;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.68-78
    • /
    • 1997
  • A numerical study on the transient vapor flow and heat transfer is performed to investigate the ideal switching operation of heat source in a high temperature heat pipe. The cylindrical 2-dimensional compressible laminar vapor flow is assumed for the vapor space and the conjugate heat transfer for the heat pipe wall, wick and vapor space is calculated. The different boundary conditions such as constant heat flux, convective or radiative boundary at the outer wall are used respectively to compare the influence of boundary conditions on the transient operation. The transient temperature profile and the internal flow of the entire pipe for the switching operation are described as a result. The results show that the transient time is not significantly affected by the boundary conditions at the outer wall in present study. During the transition, two independent flows are observed temporarily on the right side and left side of the heat pipe. It is also found that the trend of temperature variation in the vapor region is different from the variation in the wick and wall region.

Insights into fuel behaviour during relatively fast thermal transients based on calculations for two tests of the Halden IFA-507 experiment

  • Grigori Khvostov
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3801-3807
    • /
    • 2023
  • Outcomes of the project "Comprehensive Verification of the FALCON Code for Calculation of Nuclear Fuel Temperature" relating to calculation of fuel temperature during relatively fast thermal transients are presented. Good prediction capabilities of the FALCON MOD01 code coupled with the GRSW-A code are shown as applied to the data of the TF3 and TF5 tests from the Transient Temperature Experiment IFA-507. The IFA-507 related dataset of the OECD/NEA International Fuel Performance Experiments (IFPE) Database is extended by the reconstructed dynamics of the axial power distribution in the rods during the transient phase of the experiment. Based on the code calculation, the time constant of the thermal fuel response to a power transient is estimated.

Transient cooling experiments with a cooper block in a subcooled flow boiling system (과냉비등류에 있어서 동블록을 이용한 과도적 냉각실험)

  • 정대인;김경근;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.72-79
    • /
    • 1987
  • When the wall temperature is very high, a stable vapor film covers the heat transfer surface. The vapor film creates a strong thermal resistance when heat is transferred to the liquid though it. This phenomenon, called "film boiling" is very important in the heat treatment of metals, the design of cryogenic heat exchangers, and the emergency cooling of nuclear reactors. In the practical engineering problems of the transient cooling process of a high temperature wall, the wall temperature history, the variation of the heat transfer coefficients, and the wall superheat at the rewetting points, are the main areas of concern. These three areas are influenced in a complex fashion such factors as the initial wall temperature, the physical properties of both the wall and the coolant, the fluid temperature, and the flow state. Therefore many kinds of specialized experiments are necessary in the creation of precise thermal design. The object of this study is to investigate the heat transfer characteristics in the transient cooling process of a high temperature wall. The slow transient cooling experiment was carried out with a copper block of high thermal capacity. The block was 240 mm high and 79 mm O.D.. The coolant flowed throuogh the center of a 10 mm diameter channel in the copper block. In the copper block, three sheathed thermocouples were placed in a line perpendicular to the flow. These thermocouples were used to take measurements of the temperature histories of the copper block.

  • PDF

Probabilistic Fracture Mechanics Analysis of Boling Water Reactor Vessel for Cool-Down and Low Temperature Over-Pressurization Transients

  • Park, Jeong Soon;Choi, Young Hwan;Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.545-553
    • /
    • 2016
  • The failure probabilities of the reactor pressure vessel (RPV) for low temperature over-pressurization (LTOP) and cool-down transients are calculated in this study. For the cool-down transient, a pressure-temperature limit curve is generated in accordance with Section XI, Appendix G of the American Society of Mechanical Engineers (ASME) code, from which safety margin factors are deliberately removed for the probabilistic fracture mechanics analysis. Then, sensitivity analyses are conducted to understand the effects of some input parameters. For the LTOP transient, the failure of the RPV mostly occurs during the period of the abrupt pressure rise. For the cool-down transient, the decrease of the fracture toughness with temperature and time plays a main role in RPV failure at the end of the cool-down process. As expected, the failure probability increases with increasing fluence, Cu and Ni contents, and initial reference temperature-nil ductility transition ($RT_{NDT}$). The effect of warm prestressing on the vessel failure probability for LTOP is not significant because most of the failures happen before the stress intensity factor reaches the peak value while its effect reduces the failure probability by more than one order of magnitude for the cool-down transient.

Validation Test for Transient Hot-wire Method to Evaluate the Temperature Dependence of Nanofluids (나노유체 열전도율의 온도의존성 평가를 위한 비정상열선법의 시험방법)

  • Kang, Kyoung-Min;Lee, Shin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.4
    • /
    • pp.341-348
    • /
    • 2007
  • One of the controversial research issues on nanofluids is the temperature dependence of the thermal conductivity of nanofluids, that is, whether it will increase or decrease according to the temperature rise. To evaluate precisely the thermal conductivity behavior of nanofluids, a systematic way of validation experiments for the measuring instrument has been highly recommended. In this paper, procedure of the validation test for transient hot-wire method using the temperature dependence of the base fluids was explained comprehensively and the comparison of the temperature dependence of water-$Al_2O_3$ nanofluids is made between the present work and that of Das et al.

A study on the transient cooling process of a vertical-high temperature tube in an annular flow channel (환상유로에 있어서 수직고온관의 과도적 냉각과정에 관한 연구)

  • 정대인;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.156-164
    • /
    • 1986
  • In the case of boiling on high temperature wall, vapor film covers fully or parcially the surface. This phenomenon, film boiling or transition boiling, is very important in the surface heat treatment of metal, design of cryogenic heat exchanger and emergency cooling of nuclear reactor. Mainly supposed hydraulic-thermal accidents in nuclear reactor are LCCA (Loss of Coolant Accident) and PCM (Power-Cooling Mismatch). Recently, world-wide studies on reflooding of high temperature rod bundles after the occurrence of the above accidents focus attention on wall temperature history and required time in transient cooling process, wall superheat at rewet point, heat flux-wall superheat relationship beyond the transition boiling region, and two-phase flow state near the surface. It is considered that the further systematical study in this field will be in need in spite of the previous results in ref. (2), (3), (4). The paper is the study about the fast transient cooling process following the wall temperature excursion under the CHF (Critical Heat Flux) condition in a forced convective subcooled boiling system. The test section is a vertically arranged concentric annulus of 800 mm long and 10 mm hydraulic diameter. The inner tube, SUS 304 of 400 mm long, 8 mm I.D, and 7 mm O.D., is heated uniformly by the low voltage AC power. The wall temperature measurements were performed at the axial distance from the inlet of the heating tube, z=390 mm. 6 chromel- alumel thermocouples of 76 .mu.m were press fitted to the inner surface of the heating tube periphery. To investigate the heat transfer characteristics during the fast transient cooling process, the outer surface (fluid side) temperature and the surface heat flux are computed from the measured inner surface temperature history by means of a numerical method for inverse problems of transient heat conduction. Present cooling (boiling) curve is sufficiently compared with the previous results.

  • PDF

Transient heat transfer analysis of functionally graded CNT reinforced cylinders with various boundary conditions

  • Moradi-Dastjerdi, Rasool;Payganeh, Gholamhassan
    • Steel and Composite Structures
    • /
    • v.24 no.3
    • /
    • pp.359-367
    • /
    • 2017
  • In this work, transient heat transfer analysis of functionally graded (FG) carbon nanotube reinforced nanocomposite (CNTRC) cylinders with various essential and natural boundary conditions is investigated by a mesh-free method. The cylinders are subjected to thermal flux, convection environments and constant temperature faces. The material properties of the nanocomposite are estimated by an extended micro mechanical model in volume fraction form. The distribution of carbon nanotube (CNT) has a linear variation along the radial direction of axisymmetric cylinder. In the mesh-free analysis, moving least squares shape functions are used for approximation of temperature field in the weak form of heat transform equation and the transformation method is used for the imposition of essential boundary conditions. Newmark method is applied for solution time depended problem. The effects of CNT distribution pattern and volume fraction, cylinder thickness and boundary conditions are investigated on the transient temperature field of the nanocomposite cylinders.

Effects of transient thermo reflectance on the thermal responses of metal thin film exposed to ultrashort laser heating (극초단 펄스레이저 광이 입사된 금속박막의 열적반응 중 비정상반사율의 영향)

  • 박승호;국정진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.528-536
    • /
    • 1999
  • This work studies the effects of transient reflectance on the thermal responses of a metal(gold) thin-film during ultrashort laser heating. The heating process is calculated using the conventional conduction model (parabolic one-step: POS), parabolic two-step model (PTS) with and without variable properties, hyperbolic two-step model (HTS). Results from the HTS model are very similar to those from the PTS model, since the laser heating time in this study is greater than the electron relaxation time. PTS model with variable properties, however, results in totally different temperature profiles compared to those from POS models or calculation with constant properties. Transient reflectances are estimated from electron temperature distributions and based on the linear relationship between the electron temperature and complex dielectric constants. Reflectance of the front surface can be changed with respect to dielectric constants, while those of the rear surface remain unchanged.

  • PDF

Analysis of Transient Thermal Characteristics in a Gas-Loaded Heat Pipe (가스내장 히트파이프의 과도 열특성 해석)

  • 박병규;김근오;김무근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.514-523
    • /
    • 2001
  • The thermal performance characteristics of gas-loaded heat pipe(GLHP) were investigated by using transient diffuse-front model. Numerical evaluation of the GLHP is made with water as a working fluid and Nitrogen as control gas in the stainless steel tube. The transient vapor temperature and wall temperature were obtained. It is found that the temperature profiles and gas mole fraction distribution have been mainly influence by the diffusion between working fluid and noncondensable control gas in the condenser of GLHP. It is also found that he large power input make the diffusion region smaller.

  • PDF

Transient Analysis of PT-IGBT with Different Temperature (PT-IGBT의 온도에 따른 과도특성해석)

  • 이호길;류세환;이용국;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.25-28
    • /
    • 2000
  • In this study, Transient Characteristics of the Punch-Through Insulated Gate Bipolar Transistor (PT-IGBT) has been studied. On the contraty to Non-Punch Through Insulated Gate Bipolar Transistor(NPT-IGBT), PT-IGBT has buffer layer It has a simple drive circuit controlled by the gate voltage of the MOSFET and the low on-state resistance of the bipolar junction transistor. In this paper, the transient characteristics with temperature of the PT-IGBT has been analyzed analytically. PT-IGBT is made to reduce switching power loss. Excess Minority carrier distribution inactive base region and base charge, the rate of voltage with time is expressed analytically to include buffer layer.

  • PDF