• Title/Summary/Keyword: Temperature transient

Search Result 1,150, Processing Time 0.028 seconds

Simulation of Past 6000-Year Climate by Using the Earth System Model of Intermediate Complexity LOVECLIM (중간복잡도 지구시스템모델 LOVECLIM을 이용한 과거 6천년 기후 변화 모의)

  • Jun, Sang-Yoon
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.87-103
    • /
    • 2019
  • This study introduces the overall characteristics of LOVECLIM version 1.3, the earth system model of intermediate complexity (EMIC), including the installation and operation processes by conducting two kinds of past climate simulation. First climate simulation is the equilibrium experiment during the mid-Holocene (6,000 BP), when orbital parameters were different compared to those at present. The overall accuracy of simulated global atmospheric fields by LOVECLIM is relatively lower than that in Coupled Model Intercomparison Project phase 5 (CMIP5) and Paleoclimate modelling Intercomparison Project phase 3 (PMIP3) simulations. However, surface temperature over the globe, the 800 hPa meridional wind over the mid-latitude coastal region, and the 200 hPa zonal wind from LOVECLIM show similar spatial distribution to those multi-model mean of CMIP5/PMIP3 climate models. Second one is the transient climate experiment from mid-Holocene to present. LOVECLIM well captures the major differences in surface temperature between preindustrial and mid-Holocene simulations by CMIP5/PMIP3 multi-model mean, even though it was performed with short integration time (i.e., about four days in a single CPU environment). In this way, although the earth system model of intermediate complexity has a limit due to its relatively low accuracy, it can be a very useful tool in the specific research area such as paleoclimate.

Surgical Treatment of the Aortic Dissection (대동맥박리증의 외과적 치료)

  • Jung, Jong-Pil;Song, Hyun;Cho, You-Won;Kim, Chang-Hoi;Lee, Jay-Won;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1360-1365
    • /
    • 1996
  • From September 1992 to May 1996, 38 patients ranging in age from 23 to 78, were operated for aortic dissection at Asan medical center There were 21 men and 17 women. The underlying aortic pathology were acute aortic dissection in 23, chronic aortic dissection in 15. Eight patients had Martian syndrome. In 34 cases of DeBakey type I, II patients, femoral artery and vein and/or right atrial auricle were used as cannulation site. With deep hypothermic c rculatory arrest (esophageal temperature 12 $\pm$ 2.5$^{\circ}C$) and retrograde cerebral perfusion of cold oxygenated blood through SVC, we replaced the ascending aorta and the part of arch if necessary. The mean duration of the total circulatory arrest time was 25 $\pm$ 1.7 mintstuts. In 4 cases of DeBakey type III patients, we replaced descending thoracic aorta or thoracoabdomlnal aorta without shunt or bypass under normothermia with an average 30: 1.5 minutesaortic cross clamp time. One death(2.6%) occurred on the twenty-second postoperative day owing to asphyxia related to ulcer bleeding. Postoperative complications were myocardial infarction with transient left peroneal palsy in 1 case, transient lower extremity weakness in 1 case and prolonged ventilatory support in 1 case. Two patients required reoperation due to retrograde extended dissection and aortic insufuciency. There was no late death with an average 25 months follow-up period.

  • PDF

A Study on Characteristics of Airborne Asbestos Concentrations Using PCM and TEM in Life Environment Surroundings of Seoul (서울지역 생활환경주변의 공기 중 석면분포 특성에 관한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jihui;Oh, Seokryul;Shin, Jinho;Eom, Seokwon;Chae, Youngzoo;Lee, Jinsook;Koo, Jayong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.613-623
    • /
    • 2013
  • This study is purposed to evaluate the airborne asbestos concentrations in life environment surroundings in Seoul. In study, we investigated airborne asbestos concentrations in thirteen subway stations, four monitoring networks and each vicinity roadside, six stream surroundings, four tunnels quarterly and we also investigated relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks and time-based airborne asbestos concentration variability for two typical monitoring networks, two subway stations transferred and used by lots of people through Phase Contrast Microscopy (PCM) and Transmission Electron Microscopy (TEM). The airborne asbestos concentrations by PCM for 4 objects of study were less than the detection limit (7 fiber/$mm^2$) in 111 (50%) out of 223 samples. The highest concentration was 0.0130 f/cc. But additional TEM analysis result for samples exceeding the guideline value for indoor air quality (0.01 f/cc) proposed by the Ministry of Environment (Korea), no asbestos was detected. Similarly TEM analysis result for 124 samples, no asbestos was detected. The average airborne asbestos concentrations by PCM in subway stations, monitoring networks, streams and tunnels were $0.0041{\pm}0.0027$ f/cc, $0.0015{\pm}0.0011$ f/cc, $0.0024{\pm}0.0012$ f/cc and $0.0016{\pm}0.0020$ f/cc. All objects of study were satisfied with the guideline value for indoor air quality. The relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks was generally positive correlation (r = 0.660). The higher ambient temperature was and the more transient population was, the airborne asbestos concentrations by time for two subway stations were increased. While the airborne asbestos concentrations for two monitoring networks showed no variation pattern according to time.

LOCA Analysis and Development of a Simple Computer Code for Refill-Phase Analysis (냉각재 상실사고 분석 및 재충진 단계해석용 전산코드 개발)

  • Ree, Hee-Do;Park, Goon-Cherl;Kim, Hyo-Jung;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.200-208
    • /
    • 1986
  • The loss of coolant accident based on a double-ended cold leg break is analyzed with the discharge coefficient (Ca) of 0.4. This analysis covers the whole transient period from the start of depressurization to the complete refilling of the core by using RELAP4/MOD6-EM and RELAP4/ MOD6-HOT CHANNEL for the system thermal-hydraulics and the fuel performance during the blowdown phase respectively, and RELAP4/MOD6-FLOOD and TOODEE2 during the reflood phase. A simple analytical method has been developed to account for the lower plenum filling by approximating steam-water countercurrent flows and superheated wall effects at the downcomer during the refill period. Based on the informations. at the time of EOB (end-of-bypass), the refill duration time and the initial reflooding temperature were estimated and compared with the results from the RELAP4/MOD6, resulting in a good agreement. In addition, some parametric studies on the EOB were performed. The form loss coefficient between upper head and upper downcomer was found to be sensitive to the occurrence of the spurious EOB. Appropriate form loss coefficients should be taken into account to avoid the flow oscillations at the downcomer. The analyses with the six and three volume core nodalizations, respectively, show much similar trends in the system thermal-hydraulic performance, but the former case is recommended to obtain good results.

  • PDF

Heat Insulation Characteristics of Multi Layer Materials for Greenhouse (시설원예용 조합형 다겹보온자재의 보온 특성)

  • Chung, Sung-Won;Kim, Dong-Keon;Lee, Suk-Gun;Nam, Sang-Heon;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.341-347
    • /
    • 2009
  • Experiments and computations were conducted to investigate the heat insulation characteristics of multi layer materials for cultivation greenhouse. In case of the experiments, measurements of temperature were carried out with a K-type thermocouples and data logger to research the heat transfer in the experimental module generated by the heat source. A thermal conductivity meter, QTM-500 based on modified transient hot wire method was used to measure the thermal conductivity of multi layer materials. The numerical analyses were performed by commercial code CFX-11 according to the variation of multi layer materials without air layer. The experimental results showed that the heat insulation of multi layer materials was higher than single layer materials by 50~90%. It was found that the effect of heat insulation was raised by the combination of multi layer materials.

Clinical Analysis of Posterior Thoracic and Endoscopic Surgical Approach for Essential Hyperhidrosis (본태성 다한증의 후흉추 접근법 및 내시경수술의 임상고찰)

  • Cheon, Hyo Cheol;Kim, Jae Hyoo;Lee, Jung Kil;Kim, Tae Sun;Jung, Shin;Kim, Soo Han;Kang, Sam Suk;Lee, Je Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.992-997
    • /
    • 2001
  • Objectives : Essential hyperhidrosis is a common condition characterized by excessive body sweating. Excessive sweating beyond what is necessary to maintain normal body temperature need not be considered pathological unless it interferes with one's occupation and/or life-style. The existing non-operative therapeutic options seldom give sufficient relief or show a transient effect. In this regard, the thoracic sympathectomy may provide a definitive cure. In the past, surgical procedures were highly invasive and caused significant morbidity, but the minimally invasive thoracoscopic procedure provided detailed visualization of sympathetic ganglia and is associated with minimally postoperative morbidity. Nowadays, thoracoscopic transthoracic sympathectomy is accepted as the treatment of choice for essential hyperhidrosis. In palmar hyperhidrosis, however, the level of sympathetic chain to be blocked has been somewhat obscure. It is assumed that the incidence of compensatory hyperhidrosis may closely related to the extent of thoracic sympathectomy. Material & Methods : To compare the results of posterior midline approach with endoscopic sympathectomy, and the results of T2 with T2, 3 sympathectomy or sympathicotomy, we retrospectively studied 62 patients treated for palmar hyperhidrosis between September 1993 and May 2000. We reviewed medical records and recently interviewed the patients by telephone calls. Results : The treatment effect of T2 sympathectomy is no different from T2, 3 sympathectomy. But, the incidence of compensatory hyperhidrosis is less in the T2 sympathectomy group than the T2, 3 sympathectomy group. Conclusion : Thoracoscopic sympathectomy is considered a simple, safe, and effective method for treating palmar hyperhidrosis, with a shorter operation time, fewer hospital days, and a better cosmetic result, as compared with the open approaches. However, sympathicotomy seems to provide the advantages of a limited extent of denervation and the resultant decrease of compensatory hyperhidrosis compared to sympathectomy.

  • PDF

Basic Analysis of Heat and Mass Transfer Characteristics of Tubular Membrane Humidifier for Proton Exchange Membrane Fuel Cell (이온교환막 연료전지용 원통형 막 가습기의 열 및 물질전달특성 기초 연구)

  • Bae, Ho-June;Ahn, Kook-Young;Lee, Young-Duk;Kang, Sang-Kyu;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.473-480
    • /
    • 2011
  • The proton exchange membrane (PEM) fuel cell system is critically dependent on the humidity, which should be properly maintained over the entire operating range. A membrane humidifier is used for the water management in the PEMFC because of the membrane humidifier's reliable performance and zero parasitic power loss. In the PEMFC system, the membrane humidifier is required to provide appropriate humidity for the design point of the fuel cell. Although the performance of the fuel cell depends on the performance of the humidifier, few studies have provided a systematic analysis of the humidifier. We carry out an experimental analysis of the membrane humidifier using a vapor condensation bottle. The dry air pressure, water flow temperature, and air flow rate were chosen as the operating parameters. The results show that the time constant for the dynamic response of the membrane humidifier is relatively short, but additional analysis should be carried out.

Difference of Neuronal Recovery by Incubation Condition after Transient Hypoxia (배양조건에 의한 일과성 저산소상태 후 신경세포회복의 차이)

  • Moon, Soo-Hyeon;Oh, Jae-Inn;Park, Youn-Kwan;Chung, Heung-Sub;Lee, Hoon-Kap;Lee, Ki-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1161-1170
    • /
    • 2000
  • Objective : The transverse hippocampal slice is one of the most commonly studied in vitro models of mammalian brain physiology. However, despite its broad usage, there has been no standardization of slice preparation techniques or recording condition. It is well known that variations in recording conditions can result in profound different effects to neuronal responses. Evoked field potentials, recorded extracellularly, were used to investigate the effects of variations in hippocampal slice preparation protocol on hypoxia responses of CA1 neurones. Material & Methods : Before hypoxic injury, hippocampal slices were incubated for 4 hours. During incubation period, the slices were placed in a incubation chamber($21^{\circ}C$) for recovery from preparation injury and then transferred to recording chamber($34^{\circ}C$) for more recovery and baseline electric recording with current stimulation(0.1Hz). Various time periods in incubation chamber and recording chamber were applied to each experimental group(group 1=60min : 180min, group 2=90min : 150min, group 3=180min : 60min, time in incubation chamber : time in recording chamber) before 10 min hypoxia produced by replacing 95% $O_2$+5% $CO_2$ mixed gas to 95% $N_2$+5% $CO_2$ gas. Calcium, Magnesium ions and several drugs effecting on glutamate receptor also were studied. Recoveries from hypoxic injury of hippocampal slices were estimated by percent recovery of population spike(PS). Statistic analysis of study were performed using paired t-test. Results : The percent recovery of PS after 10min hypoxia was considerably enhanced by increasing the period of current stimulation during incubation period before hypoxic injury. Temperature effect on the result of this experiment was also studied(group 4) but the result from this showed no statistic significance. Low magnesium ion concentration of artificial CSF(Mg-free aCSF) during incubation period enhanced the recovery of PS but low calcium (calcium-free) and high magnesium ion concentration(2mM) reduced it after hypoxic injury. L-glutamate($100{\mu}M$) and AP-5($50{\mu}M$) had no effect on the recovery of PS but CNQX($10{\mu}M$) in artificial CSF during incubation period markedly enhanced the recovery of PS. Co-treatment of AP-5($50{\mu}M$), CNQX($10{\mu}M$) and high magnesium concentration(2mM) enhanced recovery of PS in immediate following period of hypoxic injury but the effect of cotreatment after then decayed rapidly and lost statistic significance. Conclusions : Judging from above results, the condition of baseline recording is important in observing the recovery of population spike after hypoxia, and the time and the condition should be controled more strictly to obtain reliable results.

  • PDF

Study on the Aseptic Care during Labor and Delivery, and their Effects to Peripheral Morbidity (분만시 무균처치와 산후감염의 이환율과의 관계에 대한 연구)

  • 이경혜
    • Journal of Korean Academy of Nursing
    • /
    • v.2 no.1
    • /
    • pp.141-157
    • /
    • 1971
  • The peripheral infection is one of the major causes of maternal death, and although it is preventable through an effective prenatal as well as postnatal care its morbidity is increasing due to bacterial resistant to an effective antibiotics. The primary purpose of this study was to investigate the peripheral morbidity of 949 parturients who were admitted to the Obstetrics and Gynecologic department of Ewha Woman's University Hospital from January 1971 to September 1971. Among the 949 parturients, especially 40 normal parturients were selected (20, control soup was given complete aseptic care during labor and delivery and post delivery: 20, compare group was given the ordinary care practiced during labor and delivery and maternal ward of Ewha Woman's University Hospital) for bacteriologic test on vaginal flora twice, on admission and on complete cervical dilatation of each parturient. The results obtained from this study were as follows; 1. Majority of parturients age were 21 to 35 years old(90.83%), and educational level of 949 parturients was above high school. A large number of parturients socioeconomic level (according to their husbands' job) were moderate. 2, Among the 949 parturients, multipara (55.9%) were a little more than primipara (44. 1%) and 38.84% of parturients had experienced aborition. 3. In deliverty types, normal deliveries (804 cases) were more than cesarean section deliveries (145 cases) The peripheral morbidity after normal deliveries was 0.5%, and cesarean section deliveries, 23.45%. 4. Among 949 parturients incidence of hemorrhage eases (500cc or more bleeding) showed the higher peripheral morbidity (24.86%) than other cases (bleeding less than 500cc, 7.83%). 5. The majority of parturients (81.03%) had teen taking antenatal care, but most of them were taken irregular antenatal care. On the other hand, on admission, the parturients with complication were 30.32%, and their peripheral morbidity showed much higher (7.02%) than those with no complication (2.71%). 6. The incidence of peripheral morbidity in premature ruptured membrane was higher (10.91%) than normal parturienta (1.73%). 7. In the result of aseptic care during labor and delivery and post delivery, the number of cultured bacteria was legs in control group than Compare group (in control group, on admission 17, on complete cervical dilatation 12: in compare group, on admission 21 on complete cervical dilatation 21) . The most common bacteria were Staphylococcus (control group 14 on admission, compare group 16 on admission), and next Streptococcus, E- Coil, Bacillus Subtilis, in order. Also in control group the number. of colony were reduced (43%) more than in Compare group. Transient temperature elevation from 37℃ to 37.4℃ were noted in compare group (50%) than in control group (30%), and there was no one indicated above 38℃. In conclusion, the aseptic care is the test way of preventing peripheral infection as well as decreasing the puerperal morbidity. Therefore the most important nursing care is the aseptic care for each parturient during labor and delivery and peat delivery and also all the instruments must be cleaned and sterilized.

  • PDF

Out-of-Pile Test for Yielding Behavior of PWR Fuel Cladding Material (노외 실험을 통한 가압경수형 핵연료 피복재의 항복거동연구)

  • Yi, Jae-Kyung;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.19 no.1
    • /
    • pp.22-33
    • /
    • 1987
  • The confirmed integrity of nuclear fuel cladding materials is an important object during steady state and transient operations at nuclear power plant. In this context, the clad material yielding behavior is especially important because of pellet-clad gap expansion. During the steep power excursion, the in-pile irradiation behavior differences between uranium-dioxide fuel pellet and zircaloy clad induce the contact pressure between them. If this pressure reaches the zircaloy clad yield pressure, the zircaloy clad will be plastically deformed. After the reactor power resumed to normal state, this plastic permanent expansion of clad tube give rise to the pellet-clad gap expansion. In this paper, the simple mandrel expansion test method which utilizes thermal expansion difference between copper mandrel and zircaloy tube was adopted to simulate this phenomenon. That is, copper mandrel which has approximately three times of thermal expansion coefficient of zircaloy-4 (PWR fuel cladding material) were used in this experiment at the temperature range from 400C to 700C. The measured plastic expansion of zircaloy outer radius and derived mathematical relations give the yield pressure, yield stress of zircaloy-4 clad at the various clad wall temperatures, the activation energy of zircaloy tube yielding, and pellet-clad gap expansion. The obtained results are in good agreement with previous experimental results. The mathematical analysis and simple test method prove to be a reliable and simple technique to assess the yielding behavior and gap expansion measurement between zircaloy-4 tube and uranium-dioxide fuel pellet under biaxial stress conditions.

  • PDF