• Title/Summary/Keyword: Temperature transient

Search Result 1,155, Processing Time 0.029 seconds

Evolution and scaling of a simulated downburst-producing thunderstorm outflow

  • Oreskovic, Christopher;Savory, Eric;Porto, Juliette;Orf, Leigh G.
    • Wind and Structures
    • /
    • v.26 no.3
    • /
    • pp.147-161
    • /
    • 2018
  • For wind engineering applications downbursts are, presently, almost exclusively modeled, both experimentally and numerically, as transient impinging momentum jets (IJ), even though that model contains none of the physics of real events. As a result, there is no connection between the IJ-simulated downburst wind fields and the conditions of formation of the event. The cooling source (CS) model offers a significant improvement since it incorporates the negative buoyancy forcing and baroclinic vorticity generation that occurs in nature. The present work aims at using large-scale numerical simulation of downburst-producing thunderstorms to develop a simpler model that replicates some of the key physics whilst maintaining the relative simplicity of the IJ model. Using an example of such a simulated event it is found that the non-linear scaling of the velocity field, based on the peak potential temperature (and, hence, density) perturbation forcing immediately beneath the storm cloud, produces results for the radial location of the peak radial outflow wind speeds near the ground, the magnitude of that peak and the time at which the peak occurs that match well (typically within 5%) of those produced from a simple axi-symmetric constant-density dense source simulation. The evolution of the downdraft column within the simulated thunderstorm is significantly more complex than in any axi-symmetric model, with a sequence of downdraft winds that strengthen then weaken within a much longer period (>17 minutes) of consistently downwards winds over almost all heights up to at least 2,500 m.

Examination of Strain Model Constants considering Strain Properties at High Temperature of Ultra-high-strength Concrete (초고강도 콘크리트의 고온 변형 특성을 고려한 변형모델 상수 검토)

  • Hwang, Eui-Chul;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Yoon, Min-Ho;Lee, Bo-Kyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.91-97
    • /
    • 2016
  • Evaluation on the test of actual concrete member to confirm the fire resistance of the concrete member using ultra-high strength concrete is required. However, test equipment which has large loading capacity is needed to the actual member experiment. So, many researchers evaluated the fire performance through analytical studies using the material models. This study experimentally evaluated strain properties on ultra-high-strength concrete of 80, 130 and 180 MPa with heating and examined to apply the existing strain model about ultra-high-strength concrete. As a results, constants are drawn by method of least squares applying experimental values and calculated values by the existing strain model, it proposed strain model that can be applied to ultra-high-strength concrete.

An Experimental Study on the Thermal Performance of Air Filled Thermal Diode (공기를 작동 유체로 하는 열다이오드의 열성능에 관한 실험적 연구)

  • Pak, Ee-Tong;Jang, Young-Geun;Hwang, In-Ju
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.35-42
    • /
    • 1997
  • Thermal diode is a device which allows heat to be transferred in one direction by convection due to difference of density of fluid, and blocks heat flow in the opposite direction. Vertical plate for heat collection and radiation are of utility for design of thermal diode. It was considered the transient and steady state of air filled thermal diode with guide vane which combined rectangular and parallelogrammic shape enclosures. $Gr^*$ was kept constantly on $1.11{\times}10^{10}{\sim}1.4{\times}10^{10}$ and error range was ${\pm}3%$ during the experiment. Nu was examined when inclined angle are $15^{\cir\c}\;and\;45^{\circ}$ and, also the experiments was carried out with and without guide vane as well. Specially, Nu was linearly increased due to increase of $Gr^*$, and the effect of guide vane and dimensionless channel depth was sensitive. Developed state of temperature began at dimensionless time $0.5{\sim}0.6$ due to variation of inclined angle, which is characteristic of system.

  • PDF

HEAT-TREATMENT OF LARGE-SCALE GLASS BACKPLANES IN A MUFFLE FURNACE (머플 가열로에서의 대면적 유리기판의 가열공정에 대한 열적 연구)

  • Kim, D.H.;Son, G.;Hur, N.;Kim, B.K.;Kim, H.J.;Park, S.H.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.16-23
    • /
    • 2012
  • Current display manufacturing processes apply thermal treatment of glass backplanes widely for hydrogen degassing, crystallization of thin-films, tempering, forming, and precompaction. Estimation of the characteristics of transient heating stages and thermal non-uniformities on a single glass substrate or in a stack of glasses are extremely helpful to understand non-homogeneity of mechanical and electronic features of nano/micro structures of end products. Based on simple heat transfer models and using an electric muffle furnace, temperature variations in a glass stack were predicted and measured for glass backplanes of $1.5{\times}1.85m^2$ in size and 0.7 mm in thickness. Except for the period of putting glass backplanes into the furnace, thermal radiation was the major heating mechanism for the treatment and theoretical predictions agreed well to the experimental temperatures on the backplanes. Using the theoretical model, thermal fields for a glass stack of glass-size, $2.2{\times}2.5m^2$, and of the number of sheets, 1 to 12, were calculated for practical design and manufacturing of the muffle furnace for large-scale displays, e.g. up to $8^{th}$ generation.

General Pharmacology of DA-8159, a New Pyrazolopyrimidinone Derivative (새로운 피라졸로피리미디논 유도체 DA-8159의 일반약리작용)

  • 오태영;김동환;손문호;김동성;안병옥;김순회;김원배
    • Biomolecules & Therapeutics
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 2003
  • General pharmacological properties of DA-8159, a new pyrazolopyrimidinone derivative were examined in laboratory animals to investigate its safety profile. The oral administration of DA-8159 (1, 5 or 30 mg/kg) in mice and rats had no effect on general behaviors and central nervous system of the animals in test systems, such as hexobarbital-induced sleeping time, motor coordination, normal body temperature, writhing syndromes induced by 0.75% acetic acid solution, chemo-shock produced by pentetrazole solution and rotar rod test. Anesthetized cats treated intravenously with DA-8159 (0.1, 0.3, 1, 3 or 10 mg/kg) showed transient and mild decrease in blood pressure. However, heart rate, respiration rate and tidal volume were not changed by intravenous DA-8159. In the isolated organs including ileum, heart (sinus rate of atria and contractility of papillary muscle), trachea of guinea pigs and phrenic nerve of rats, DA-8159 ($10^{-8}$$10^{-5}$ mg/L) did not elicit any effect or inhibitory action on the chemically or electrically stimulated contraction. DA-8159 did not influence gastric secretion, pH and total acid output in rats and intestinal propulsion in mice. The administration of DA-8159 in rats had no effect on the platelet aggregation induced by ADP in rabbit plasma, urinary volume and electrolyte ion ($Na^{+}$, $K^{+}$, $Cl^{-}$) excretion in rats. Prothrombin time (PT) of the rats showed a mild but significant increase after administration of DA-8159. Activated partial thromboplastin time (APTT), however, was not affected by DA-8159. These results indicate that DA-8159 does not exert any of serious pharmacological effects.

Evaluation of the Wear Comfort of Women's Fitted Sports T-shirts Made from Cool-Touch Fabrics (냉감 소재를 활용한 밀착형 여성 스포츠 상의의 착용쾌적성 평가)

  • Kim, Soyoung;Choi, Jiyoung;Lee, Heeran;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.5
    • /
    • pp.929-938
    • /
    • 2017
  • This research investigated the effects of cool touch fabrics on thermo-regulating physical properties and subjective evaluation using a 3D fitted women's T-shirts in wear test. Qmax, clothing microclimate, microclimate wettedness, thermogram and subjective vote were observed during rest-right after an exercise-rest protocol. As a result, there was no single determining physical variable to explain the reasons of cool sensations of T-shirts made of cool touch fabric across the entire protocol. Qmax could partly predict a wear sensation at the initial stage when only insensible perspiration was presented. Simultaneous observation of temperature/humidity gradient understand from the inside to the outside of the clothing layer or microclimate wettedness calculated using vapor pressure were helpful to figure out the performance of cool touch fabric, especially at the later stage of the protocol when sweating was excessive. It was especially difficult to connect thermo-regulating physical variables to the subjective evaluation during transient conditions such as 'right after exercise' stage. It is necessary to measure the amount of heat and moisture transferred from the skin to the outside of clothing along with the physical properties measured in this study to understand the detailed mechanisms of why a cool sensation is evoked from tight fitting T-shirts made of newly developed cool touch fabrics.

Enhanced Controlled Transdermal Delivery of Hydrochlorothiazide from an Ethylene-vinyl Acetate Matrix

  • Kim, Dal-Keun;Park, Jung-Chan;Chang, Ik-Hyun;Kang, Chung;Ryu, Sang-Rok;Shin, Sang-Chul
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.3
    • /
    • pp.167-173
    • /
    • 2010
  • Repeated oral administration of hydrochlorothiazide, a loop diuretic, due to transient high blood levels, may cause adverse effects such as gastric disturbance, nausea, high blood sugar, and hyper lipidemia. Transdermal administration could avoid some of these systemic side effects and gastric disorders. We have developed a matrix using ethylene-vinyl acetate (EVA), a heat-processible and flexible material, for transdermal delivery of hydrochlorothiazide. Drug solubility was highest at 40% PEG-400 volume fraction. Drug release increased as concentration increased with a linear relationship between the release rate and the square root of loading dose. Increasing temperature increased drug release from the EVA matrix. The activation energy, measured from the slope of log P versus 1000/T, was 11.9 kcal/mol for a 2.5% loading dose from EVA matrix. Diethyl phthalate had the highest plasticizing effects on the release of hydrochlorothiazide. To increase the skin permeation of hydrochlorothiazide from the EVA matrix, enhancers such as the saturated fatty acids, the unsaturated fatty acids, and the non-ionic surfactants were added to the EVA matrix, and skin permeation was evaluated using a modified Keshary-Chien diffusion cell fitted with intact excised rat skin. Polyoxyethylene 23-lauryl ether showed the highest enhancing effects. In conclusion, transdermal delivery of hydrochlorothiazide could be improved from an EVA matrix containing plasticizer and permeation enhancer.

Numerical Investigation of the Urea Melting and Heat Transfer Characteristics with Three Different Types of Coolant Heaters (냉각수 순환 방식 가열원 형상에 따른 요소수 해동 특성에 관한 수치적 연구)

  • Lee, Seung-Yeop;Kim, Man-Young;Lee, Chun-Hwan;Park, Yun-Beom
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.4
    • /
    • pp.125-132
    • /
    • 2012
  • Urea-SCR system, which converts nitrogen oxides to nitrogen and water in the presence of a reducing agent, usually AdBlue urea solution, is known as one of the powerful NOx reduction systems for mobile as well as stationary applications. For its consistent and reliable operation in mobile applications, such various problems as transient injection, ammonia slip, and freezing in cold weather have to be resolved. In this work, therefore, numerical study on three-dimensional unsteady heating problems were analyzed to understand the melting and heat transfer characteristics such as urea liquid volume fraction, temperature profiles and generated natural convection behavior in urea solution by using the commercial software Fluent 6.3. After validating by comparing numerical and experimental data with pure gallium melting phenomena, numerical experiment for urea melting is conducted with three different coolant heating models named CH1, 2, and 3, respectively. Finally, it can be found that the CH3 model, in which more coolant is concentrated on the lower part of the urea tank, has relatively better melting capability than others in terms of urea quantity of $1{\ell}$ for start-up schedule.

Hepatic Expression of Cu/Zn-Superoxide Dismutase Transcripts in Response to Acute Metal Exposure and Heat Stress in Hemibarbus mylodon (Teleostei: Cypriniformes)

  • Cho, Young-Sun;Bang, In-Chul;Lee, Il-Ro;Nam, Yoon-Kwon
    • Fisheries and Aquatic Sciences
    • /
    • v.12 no.3
    • /
    • pp.179-184
    • /
    • 2009
  • Hemibarbus mylodon (Cypriniformes) is an endemic freshwater fish species in the Korean peninsula, for which urgent conservation efforts are needed. To understand their stress responses in relation to metal toxicity and thermal elevation, we performed a real-time RT-PCR-based expression assay of hepatic copper/zinc-superoxide dismutase (Cu/Zn-SOD), a key antioxidant enzyme, in response to experimental heavy metal exposure or heat treatment. The transcription of hepatic Cu/Zn-SOD was differentially modulated by acute exposure to Cu, cadmium (Cd), or Zn. Exposure to each metal at $5{\mu}M$ for 24 h revealed that Cu stimulated the mRNA expression of Cu/Zn-SOD to a greater extent than the other two heavy metals. The elevation in Cu/Zn-SOD transcripts in response to Cu exposure was dose-dependent (0.5 to $5{\mu}M$). Time course analysis of Cu/Zn-SOD expression in response to Cd exposure ($5{\mu}M$) revealed a transient pattern up to day 7. Exposure to thermal stress (an increase from 22 to $30^{\circ}C$ at a rate of $1^{\circ}C/h$ followed by $30^{\circ}C$ for 18 h) did not significantly alter SOD transcription, although heat shock protein 90 kDa (HSP90) transcription was positively correlated with an increase in temperature.

TRPV1 in Salivary Gland Epithelial Cells Is Not Involved in Salivary Secretion via Transcellular Pathway

  • Choi, Seulki;Shin, Yong-Hwan;Namkoong, Eun;Hwang, Sung-Min;Cong, Xin;Yu, Guangyan;Park, Kyungpyo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.18 no.6
    • /
    • pp.525-530
    • /
    • 2014
  • Transient receptor potential vanilloid subtype 1 (TRPV1) was originally found in sensory neurons. Recently, it has been reported that TRPV1 is expressed in salivary gland epithelial cells (SGEC). However, the physiological role of TRPV1 in salivary secretion remains to be elucidated. We found that TRPV1 is expressed in mouse and human submandibular glands (SMG) and HSG cells, originated from human submandibular gland ducts at both mRNA and protein levels. However, capsaicin (CAP), TRPV1 agonist, had little effect on intracellular free calcium concentration ($[Ca^{2+}]_i$) in these cells, although carbachol consistently increased $[Ca^{2+}]_i$. Exposure of cells to high temperature (> $43^{\circ}C$) or acidic bath solution (pH5.4) did not increase $[Ca^{2+}]_i$, either. We further examined the role of TRPV1 in salivary secretion using TRPV1 knock-out mice. There was no significant difference in the pilocarpine (PILO)-induced salivary flow rate between wild-type and TRPV1 knock-out mice. Saliva flow rate also showed insignificant change in the mice treated with PILO plus CAP compared with that in mice treated with PILO alone. Taken together, our results suggest that although TRPV1 is expressed in SGEC, it appears not to play any direct roles in saliva secretion via transcellular pathway.