• 제목/요약/키워드: Temperature test equipment

검색결과 330건 처리시간 0.023초

PERFORMANCE EVALUATION OF BUBBLE PUMP USED IN A PASSIVE SOLAR WATER HEATER SYSTEM

  • ;박기태;정한식;정효민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2309-2314
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and flow-rates at various locations. The theory analysis of design bubble pump has been given and the experiment design has been included in the paper.

  • PDF

ITER AC/DC Converter 서브랙의 EN 61000 및 IEC 61010에 의한 EMC/LVD 시험평가 (EMC/LVD Compatibility Evaluation of ITER AC/DC Converter Subrack by EN 61000 and IEC 61010)

  • 신현국;오종석;송인호;서재학;최정완
    • 전력전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.222-226
    • /
    • 2021
  • To comply with CE marking requirements, the electromagnetic compatibility (EMC) and low-voltage directive (LVD) tests are conducted on the sub-racks of International Thermonuclear Experimental Reactor (ITER) AC/DC converters and bypass switches. The EMC tests consist of a series of tests, including the electromagnetic interference test, the electromagnetic field immunity test, and the rapid transient burst immunity test. In the LVD test, the electric shock protection test, the xcessive temperature limit and heat resistance of equipment tests, and the fire spread prevention test are performed. This work presents and reviews the European Directive for EMC/LVD and introduces the methods of EMC and LVD tests for the sub-racks of AC/DC converters and bypass switches. It also evaluates the test method and results to meet the European Directive requirements for CE marking. The sub-racks of ITER AC/DC converters and bypass switches successfully pass the EMC and LVD tests.

Flip-chip 본딩 장비 제작 및 공정조건 최적화 (Bonding process parameter optimization of flip-chip bonder)

  • 심형섭;강희석;정훈;조영준;김완수;강신일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.763-768
    • /
    • 2005
  • Bare-chip packaging becomes more popular along with the miniaturization of IT components. In this paper, we have studied flip-chip process, and developed automated bonding system. Among the several bonding method, NCP bonding is chosen and batch-type equipment is manufactured. The dual optics and vision system aligns the chip with the substrate. The bonding head equipped with temperature and force controllers bonds the chip. The system can be easily modified for other bonding methods such as ACF In bonding process, the bonding forte and temperature are known as the most dominant bonding parameters. A parametric study is performed for these two parameters. For the test sample, we used standard flip-chip test kit which consists of FR4 boards and dummy flip-chips. The bonding test was performed fur two types of flip-chips with different chip size and lead pitch. The bonding temperatures are chosen between $25^{\circ}C\;to\;300^{\circ}C$. The bonding forces are chosen between 5N and 300N. The bonding strength is checked using bonding force tester. After the bonding force test, the samples are examined by microscope to determine the failure mode. The relations between the bonding strength and the bonding parameters are analyzed and compared with bonding models. Finally, the most suitable bonding condition is suggested in terms of temperature and force.

  • PDF

극한 환경 내 안전조치 장비 운영에 관한 연구 (Research on the Operation of Safeguards Equipment in Extreme Environmental Conditions)

  • 한지영;박수희;박제완;김용민
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1189-1195
    • /
    • 2023
  • 원자력 시설 사찰, 검증 등의 상황을 가정하였을 때, 현장 내 안전조치 장비의 정상 작동 담보는 필수적 요소이다. 카자흐스탄의 핵실험금지조약 현장 사찰 대비 훈련에서 극저온으로 인해 장비가 정상 운영되지 못한 선례가 있으며 북한 풍계리 핵실험장의 연중 최저 기온은 영하 30도 내외이다. 한반도 원자력 활동 현장 검증을 위해서는 극한 환경 내 장비의 정상 작동 담보를 위한 관련 연구가 필요하며, 여기에는 사찰 및 검증에 활용되는 장비 확인, 정상 작동을 방해하는 위험요인 분석 등이 포함된다. 본 연구는 극한 환경 내 장비의 정상 운영을 위한 위험성 분석, 환경 기반 성능 시험 기준 및 절차 개발을 목적으로 한다. 이를 위해 IAEA 안전조치 방법, 활용 장비 분석, 한반도 환경 특성과 현장 검증을 위한 운반에 따른 위험성 분석을 수행하고 성능 시험 기준 및 절차를 제시하였다. 연구 결과는 핵활동 검증 및 감시 과정에서 참고 자료로 활용될 수 있으며, 한반도 비핵화 참여에 대비한 정책 및 전략 수립에 기여할 것으로 판단된다.

비공비 혼합 냉매를 이용한 2단 이코노마이져 시스템 개발 (Development of 2-Stage Economizer System Using the Non-Azeotropic Mixtures.)

  • 염한길;김욱중;이성진;홍용주
    • 연구논문집
    • /
    • 통권25호
    • /
    • pp.77-90
    • /
    • 1995
  • For improving performance of heat pump system, researcher has adapted 2-stage economizer cycle and developed a high-efficiency screw compressor, new working medium(non-azeotropic mixed refrigerant) and counterflow heat exchangers operating with a small temperature difference. Target of this study is development of high performance heat pump system with the 2-stage economizer system using the non-azeotropic mixed refrigerant. For the purpose of excuting target, we constucted computer simulation programs, compared and examed various types of cycle and non-azeotropic mixture. Based on the results from computer simulation we selected optimum mixtures and reflected design and production process of performance test equipment with the 1-stage econmizer system. In order to accomplish the final target, design and production of the 2-stage economizer system, we performed pilot test using the 1-stage economizer performance test system and finally design and production of the 2-stage economizer system.

  • PDF

Design and Analysis of an Accelerated Life Test for Magnetic Contactors

  • Ryu, Haeng-Soo;Park, Sang-Yong;Han, Gyu-Hwan;Kwon, Young-Il;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.188-193
    • /
    • 2007
  • Magnetic contactors (MCs) are widely used in industrial equipment such as elevators, cranes and factory control rooms in order to close and open the control circuits. The reliability of MCs mainly depend on mechanical durability and international standards such as IEC 60947-4-1, which stipulates the testing method for MCs. Testing time, however, is so long in usual cases that a method of reducing testing time is required. Therefore, a temperature and voltage-accelerated life testing (ALT) method has been developed to reduce the testing time in this work. The accelerated life test data are analyzed and acceleration factors (AFs) are provided.

전기가열장치를 이용한 연약지반개량 (Improvement of Soft Ground using Electric Heating Equipment)

  • 한희수;임은상;이금성;장동훈
    • 한국지반환경공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.5-12
    • /
    • 2014
  • 본 논문은 심층연약지반 개량용 전기가열장치를 개발하여 경기도 화성시 인근 연약지반에 적용한 것이다. m당 1 kW의 전기를 소비하는 니켈-크롬선으로 구성된 길이 4.0 m의 전기가열장치를 지표하 3.5~6.5 m 사이에 설치하여 48시간의 지반가열을 2회, 총 96시간 실시하였으며, 온도계와 압력계를 지표하 5.0 m 지점에 매설하여 지반가열에 의한 온도 및 증기압 변화를 측정하였다. 실험결과 가열원으로부터 횡방향 거리의 온도분포 및 선단지지력의 변화는 이차함수를 나타내었으며, 둘 다 R2값은 1로 산정되었다. 또한, 전기가열로 인해 수증기가 배출됨에 따라, 함수비 및 간극수압이 감소함을 관찰할 수 있었다.

산업 설비 재료에 CCO박막의 적용을 위한 부식성 분석 (Corrosion analysis for application of CCO thin films to industrial equipment materials)

  • 백민숙
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.98-103
    • /
    • 2018
  • 산업의 발전에 따라 설비 및 재료 등 따라서 재료 표면의 특성을 내식성 및 고강도, 내마모성 등을 향상 시키기 위하여 지금까지 많은 코팅 기술들이 발전해 왔다. 그 중 CCO(CaCoO, 이후 CCO) 박막 형성은 전자재료 영역에서 연구, 사용이 되어오고 있는데, 이 CCO 박막의 특징 중 하나가 고온의 열에 강하다는 것이 있다. 특히 CCO 박막을 형성 시키는 방법 또한 비교적 간단하여 고온의 산화 분위기에 도입이 가능 할 것으로 판단되었다. 따라서 본 연구에서는 이 CCO 박막의 코팅이 용융 아연 도금 설비에 적용을 하기 전에, 고온 및 Zn fume에 대한 부식성을 파악하여 용융 아연 도금 설비에 적용이 가능한지를 파악하기 위한 실험 및 분석을 실시 하였다. 우선 기본 소재 STS304 표면에 CCO 박막을 형성 시키고, 650도의 대기로에서 Zn fume의 분위기 내에서 산화 시킨 후 CCO 박막의 부식 정도를 확인 및 측정 하였다. 산화는 30일간 진행되었고, 30일 후 SEM을 이용하여 CCO박막의 형상을 확인 하였으며 동전위분극 실험을 통하여 부식성을 분석하였다.

고온 오븐 접합을 적용한 PEEK, PEI 기반 CF/PEKK 복합재의 접착 강도 및 계면 특성 평가 (Adhesive Strength and Interface Characterization of CF/PEKK Composites with PEEK, PEI Adhesives Using High Temperature oven Welding Process)

  • 박성재;이교문;박수정;김윤해
    • Composites Research
    • /
    • 제35권2호
    • /
    • pp.86-92
    • /
    • 2022
  • 본 연구에서는 접착제를 구성하는 분자 결합 구조의 차이가 열가소성 복합재의 계면 특성에 미치는 영향을 판단하기 위해 진행되었다. 고온 오븐 접합 공정을 이용하여 carbonfiber/polyetherketoneketone(CF/PEKK) 열가소성 복합재료를 융합 접합, polyetheretherketone(PEEK), polyetherimide(PEI) 접착제 접합하였다. 그리고 lap 전단 강도 시험과 디지털 광학 현미경과 주사 전자 현미경을 이용한 파단면 분석, FTIR 분석을 수행하였다. 그 결과, 접착제 접합은 CF/PEKK와 접착제를 구성하는 주요 결합기인 에테르기, 케톤기, 이미드기의 결합이 증가한 인터페이즈를 형성하여 접착 강도를 강화시켰다. 그리고, 에테르기와 케톤기를 더 많이 함유한 PEEK를 사용하는 것이 더 강한 결합력을 갖는 인터페이즈를 형성하여, 복합재의 접착 강도를 향상시켰다.

Study on Properties and Accelerated Life-time Test of Rubber O-ring by Temperature Stress

  • Shin, Young-Ju;Kang, Bong-Sung;Chung, Yu-Kyung;Choi, Kil-Yeong;Shin, Sei-Moon
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2006년도 학술발표대회 논문집
    • /
    • pp.48-54
    • /
    • 2006
  • In this thesis, accelerated life test (ALT) method and procedure for rubber O-ring are applied to assure specified reliability of the products at guaranteeing the life of the products. Rubber O-ring is parts that keep intensity or make machine operation smoothly on attrition portion of machine and is used to prevent that oil is leaked. Usually. Rubber O-ring used NBR that is copolymer of acrylonitrile and butadiene. this are superior oil resistance, heat resistance, durability of abrasion, cold resistance, chemical resistance etc. The accelerated life test model for rubber O-ring are developed using the relationship between stresses and life characteristics of products. Using the accelerated life test method and the acceleration life test equipment which is developed, we performed life test, collected life data and analyzed the results of tests. The proposed accelerated life test method and procedure may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably.

  • PDF