• Title/Summary/Keyword: Temperature response

Search Result 3,361, Processing Time 0.029 seconds

Nonlinear Regression Analysis to Determine Infection Models of Colletotrichum acutatum Causing Anthracnose of Chili Pepper Using Logistic Equation

  • Kang, Wee-Soo;Yun, Sung-Chul;Park, Eun-Woo
    • The Plant Pathology Journal
    • /
    • v.26 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • A logistic model for describing combined effects of both temperature and wetness period on appressorium formation was developed using laboratory data on percent appressorium formation of Colletotrichum acutatum. In addition, the possible use of the logistic model for forecasting infection risks was also evaluated as compared with a first-order linear model. A simplified equilibrium model for enzymatic reactions was applied to obtain a temperature function for asymptote parameter (A) of logistic model. For the position (B) and the rate (k) parameters, a reciprocal model was used to calculate the respective temperature functions. The nonlinear logistic model described successfully the response of appressorium formation to the combined effects of temperature and wetness period. Especially the temperature function for asymptote parameter A reflected the response of upper limit of appressorium formation to temperature, which showed the typical temperature response of enzymatic reactions in the cells. By having both temperature and wetness period as independent variables, the nonlinear logistic model can be used to determine the length of wetness periods required for certain levels of appressorium formation under different temperature conditions. The infection model derived from the nonlinear logistic model can be used to calculate infection risks using hourly temperature and wetness period data monitored by automated weather stations in the fields. Compared with the nonlinear infection model, the linear infection model always predicted a shorter wetness period for appressorium formation, and resulted in significantly under- and over-estimation of response at low and high temperatures, respectively.

Effect of initial ground temperature measurement on the design of borehole heat exchanger (초기 지중온도 측정이 지중 열교환기 설계에 미치는 영향)

  • Song, Yoon-ho;Kim, Seong-Kyun;Lee, Kang-Kun;Lee, Tae-Jong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.600-603
    • /
    • 2009
  • We compared relative importance of thermal conductivity and initial ground temperature in designing borehole heat exchanger network and also we test accuracy of ground temperature estimation in thermal response test using a proven 3-D T-H modeler. The effect of error in estimating ground temperature on calculated total length of borehole heat exchanger was more than 3 times larger than the case of thermal conductivity in maximum 20% error range. Considering 10% of error in estimating thermal conductivity is generally acceptable, we have to define the initial ground temperature within 5% confidence level. Utilizing the mean annual ground surface temperature and the geothermal gradient map compiled so far can be a economic way of estimating ground temperature with some caution. When performing thermal response test for estimating ground temperature as well as measuring thermal conductivity, minimum 100 minutes of ambient circulation is required, which should be even more in case of very cold and hot seasons.

  • PDF

Effect of Working Temperature on Sensitivity of Au/SnO2 Core-Shell Structure Nanoparticles for CO Gas (Au/SnO2 core-shell 나노구조 센서의 구동온도가 CO 감동에 미치는 영향)

  • Yu, Yeon-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.456-460
    • /
    • 2012
  • Au/$SnO_2$ core-shell structure nanoparticles (NPs) were synthesized by microwave hydrothermal method, and the effect of working temperature on sensitivity of Au/$SnO_2$ core-shell NPs for CO gas was investigated. The $SnO_2$ shell layer was consisted of $SnO_2$ primary particles with 4.5 nm diameter. The response of Au/$SnO_2$ core-shell NPs for CO gas was maximized at the working temperature of $350^{\circ}C$ while the sensitivity increased with decreasing the working temperature due to the low grain size effect of $SnO_2$ NPs on the response of CO gas.

A Study on the Low Temperature Bleaching of Cotton with Peroxygen Boosters (과산화조제에 의한 면직물의 저온표백에 관한 연구)

  • Choi, Chul Ho;Lee, Chan Min
    • Textile Coloration and Finishing
    • /
    • v.8 no.2
    • /
    • pp.35-42
    • /
    • 1996
  • Peroxodisulfates are being developed as low temperature bleaching agents for cotton fabrics to save the thermal energy. In this research we used the colar difference meter to determine the whiteness which peroxide booster will possibly make an effect on cotton fabric at the low temperature process using consist of temperature with different conditions agents, such as sodium hydroxide, sodium peroxodisulfate and potassium peroxodisulfate. The peroxide bleaching follows a laboratory experiments, using a statistical plan for three variables: the concentrations of hydrogen peroxide and sodium hydroxide and the temperature of bathing. The purpose of this research was to use the response surface analysis method to evaluate the relative importance of factors providing optimum whiteness. A ridge analysis of the data on whiteness response results in 3-D response surface diagrams for optimizing the concentrations of hydrogen peroxide and sodium hydroxide at about 42~52$^{\circ}C$.

  • PDF

LBCC of Transient State for High Strength Steel in Hot Strip Mills (열연 고강도강의 비정상부 온도제어를 위한 LBCC 개발)

  • Park, Cheol-Jae;Yoon, Kang-Sup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.4
    • /
    • pp.382-387
    • /
    • 2011
  • In this paper, a LBCC (Latter Bank Cooling Control) for the high strength steel is proposed to obtain the desirable temperature and the property of the material along the longitudinal direction of the steel on the ROT (Run-Out Table) process. A cooling valve is modeled to analyze the response of the ROT banks. The control concept is derived from a field data, a valve model considering the valve response and a TTT (Time-Temperature Transformation) diagram. The proposed control is verified from the simulation results under the various carbon quantities. It is shown through the field test of the hot strip mill that the deviation of the CT (Coiling Temperature) is considerably decreased by the proposed temperature control.

Dynamic Response of Polyurethane Foam with Density and Temperature Effects (폴리우레탄 폼의 동적 응답에 미치는 밀도 및 온도의 영향)

  • Hwang, Byeong-Kwan;Kim, Jeong-Hyun;Kim, Jeong-Dae;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.4
    • /
    • pp.291-297
    • /
    • 2019
  • Polyurethane foam is the most efficient, high-performance insulation material, used for liquefied natural gas carrier (LNGC) insulation. Because LNGC is exposed to sloshing impact load due to ship motion of 6 degrees of freedom, polyurethane foam should be sufficient dynamic properties. The dynamic properties of these polyurethane foam depends on temperature and density. Therefore, this study investigates the dynamic response of polyurethane foam for various temperature($25^{\circ}C$, $-70^{\circ}C$, $-163^{\circ}C$) and density($90kg/m^3$, $113kg/m^3$, $134kg/m^3$, $150kg/m^3$) under drop impact test with impact energy of 20J, 50J, and 80J. For dynamic response was evaluated in terms of peak force, peak displacement, absorb energy, and the mechanical property with minimized density effects. The results show the effect of temperature and density on the polyurethane foam material for the dynamic response.

Room Temperature Hydrogen Gas Sensor Based on Carbon Nanotube Yarn (상온감지 가능한 탄소나노튜브 방적사 기반의 수소 감지 센서)

  • Kim, Jae Keon;Lee, Junyeop;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.132-136
    • /
    • 2018
  • We report the development of a room-temperature hydrogen ($H_2$) gas sensor based on carbon nanotubes (CNT) yarn. To detect $H_2$ gas in room temperature, a highly ordered CNT yarn was placed on a substrate from a spin-capable CNT forest, followed by the deposition of a platinum (Pt) layer on surface of the CNT yarn. To examine the effect of the Pt-layer on the response of the CNT sensor, a comparative sensing performance was characterized on both the Pt deposited and non-deposited CNT yarn at room temperature. The Pt-CNT yarn yielded high response, whereas the non-deposited CNT yarn showed negligible response for $H_2$ detection at room temperature. Pt is a reliable and efficient catalyst that can substantially improve the detection of $H_2$ gas by chemical sensitization via a "spillover" effect. It can be efficiently utilized to increase the sensitivity and selectivity as well as to obtain fast response and recovery times.

A Real Time Model of Dynamic Thermal Response for 120kW IGBT Inverter (120kW급 IGBT 인버터의 열 응답 특성 실시간 모델)

  • Im, Seokyeon;Cha, Gangil;Yu, Sangseok
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.2
    • /
    • pp.184-191
    • /
    • 2015
  • As the power electronics system increases the frequency, the power loss and thermal management are paid more attention. This research presents a real time model of dissipation power with junction temperature response for 120kw IGBT inverter which is applied to the thermal management of high power IGBT inverter. Since the computational time is critical for real time simulation, look-up tables of IGBT module characteristic curve are implemented. The power loss from IGBT provides a clue to calculate the temperature of each module of IGBT. In this study, temperature of each layer in IGBT is predicted by lumped capacitance analysis of layers with convective heat transfer. The power loss and temperature of layers in IGBT is then communicated due to mutual dependence. In the dynamic model, PWM pulses are employed to calculation real time IGBT and diode power loss. Under Matlab/Simulink$^{(R)}$ environment, the dynamic model is validated with experiment. Results showed that the dynamic response of power loss is closely coupled with effective thermal management. The convective heat transfer is enough to achieve proper thermal management under guideline temperature.

Effects of Self-Foot Reflexology on Stress, Fatigue, Skin Temperature and Immune Response in Female Undergraduate Students (자가발반사요법이 여대생의 스트레스, 피로, 피부온도 및 면역반응에 미치는 효과)

  • Lee, Young-Mee
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.1
    • /
    • pp.110-118
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the effects of self-foot reflexology on stress (perceived stress, urine cortisol level, and serum cortisol level), fatigue, skin temperature and immune response in female undergraduate students. Methods: The research design was a nonequivalent control group pretest-post test design. Participants were 60 university students: 30 in the experiment group and 30 in the control group. The period of this study was from April to June 2010. The program was performed for 1 hr a session, three times a week for 6 weeks. The data were analyzed using the SPSS/WIN 17.0 program. Results: The results showed that self-foot reflexology was effective in reducing perceived stress and fatigue, and raised skin temperature in female undergraduate students. But cortisol levels and immune response were not statistically significant different. Conclusion: The results of this study indicate that self-foot reflexology is an effective nursing intervention in reducing perceived stress and fatigue and, in improving skin temperature. Therefore, it is recommended that this be used in clinical practice as an effective nursing intervention for in female undergraduate students.

Decaying temperature and dynamic response of a thermoelastic nanobeam to a moving load

  • Zenkour, Ashraf M.;Abouelregal, Ahmed E.
    • Advances in Computational Design
    • /
    • v.3 no.1
    • /
    • pp.1-16
    • /
    • 2018
  • The decaying temperature and dynamic response of a thermoelastic nanobeam subjected to a moving load has been investigated in the context of generalized theory of nonlocal thermoelasticity. The transformed distributions of deflection, temperature, axial displacement and bending moment are obtained by using Laplace transformation. By applying a numerical inversion method, the results of these fields are then inverted and obtained in the physical domain. Also, for a particular two models, numerical results are discussed and presented graphically. Some specific and special results are derived from the current study.