• Title/Summary/Keyword: Temperature of coefficient of resistance

Search Result 541, Processing Time 0.032 seconds

Thermoelectric properties of individual PbTe nanowires grown by a vapor transport method

  • Lee, Seung-Hyun;Jang, So-Young;Lee, Jun-Min;Roh, Jong-Wook;Park, Jeung-Hee;Lee, Woo-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.7-7
    • /
    • 2009
  • Lead telluride (PbTe) is a very promising thermoelectric material due to its narrow band gap (0.31 eV at 300 K), face-centered cubic structure and large average excitonic Bohr radius (46 nm) allowing for strong quantum confinement within a large range of size. In this work, we present the thermoelectric properties of individual single-crystalline PbTe nanowires grown by a vapor transport method. A combination of electron beam lithography and a lift-off process was utilized to fabricate inner micron-scaled Cr (5 nm)/Au (130 nm) electrodes of Rn (resistance of a near electrode), Rf (resistance of a far electrode) and a microheater connecting a PbTe nanowire on the grid of points. A plasma etching system was used to remove an oxide layer from the outer surface of the nanowires before the deposition of inner electrodes. The carrier concentration of the nanowire was estimated to be as high as $3.5{\times}10^{19}\;cm^{-3}$. The Seebeck coefficient of an individual PbTe nanowire with a radius of 68 nm was measured to be $S=-72{\mu}V/K$ at room temperature, which is about three times that of bulk PbTe at the same carrier concentration. Our results suggest that PbTe nanowires can be used for high-efficiency thermoelectric devices.

  • PDF

Review of effects of friction coefficient of moving bearing on Stability of CWR (가동단 마찰계수가 장대레일 축력 안정성에 미치는 영향 검토)

  • Ryu Jae-Nam;Choi Young-Joon;Yang Sin-Chu
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.812-817
    • /
    • 2004
  • Recently drastic improvement of railway technology has been accompanied by the construction of very high-speed tracks. It should be noticed that Continuously Welded Rail(CWR) has played significant role in technical development of railway and that installation of CWR is now being scheduled on existing lines as well as newly-built lines. In general, interaction between CWR and bridge deck takes place on bridge section and additional axial force and displacement is to be developed owing to temperature and braking/acceleration forces. This interaction is known to be mainly governed by span organizations and arrangements of foot bearings. In common practice, movable bearing is stationed and designed on the assumption that it is not able to transfer the horizontal force of upper decks. However, it is well known that horizontal resistance is developed in movable bearings due to friction and that friction coefficient of movable bearing is ranged from 0.03 to 0.20 depending on the material of bearings and magnitude of reactions. Therefore, it is easily reasoned out that friction of movable bearing can influence the mutual behavior of CWR and bridge decks. Suggested in this study is to investigate the validity and efficiency of friction effect of movable bearings in controlling the axial force and displacement of CWR on continuous railway bridges.

  • PDF

A Study on the Frictional Abrasion Properties of MMC (금속기 복합재료의 마찰ㆍ마모 특성에 관한 연구)

  • 이광영;박원조;허선철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.171-177
    • /
    • 2002
  • Metal matrix composites had generated a lot of interest in recent times because of significant in specific properties, it was also highlighted as the material of frontier industry because strength, heat-resistant, corrosion-resistant and wear-resistant were superiored. In recent years, the study of metal matrix composite has increased by aluminum alloy. The study is based on the tribological properties of AC4CH that is a part of the mechanical property of metal matrix composites. Metal matrix composite that is produced from matrix material AC4CH and reinforcement SiO$_2$, Al$_2$O$_3$ and TiO$_2$ are added to the metal matrix composite fur strength so binding among the whisker can take place. Each metal matrix composite is produced using the squeeze casting method. To test for tribe a pin-on-disk machine and lubricant is used without paraffine 8.2CST at room temperature which is 40$\^{C}$. As the results of this study, the tribological properties of each specimen are more improved than AC4CH. The variation of coefficient resistance is more stable at the AC4CH and TiO$_2$, but the variation rates are higher at the inanimate binder.

The Changes of Transfer film and friction Characteristics with the Relative Amounts of Raw Materials (자동차용 마찰재에서 각 원료의 상대량에 따른 전이막 형성 및 마찰특성의 변화)

  • Cho, Min-Hyung;Lee, Jae-Young;Kim, Dae-Hwan;Cheong, Geun-Joong;Choi, Chun-Rak;Jang, Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.271-280
    • /
    • 2001
  • An NAO friction material (low-steel type) containing 15 ingredients was investigated to study the role of transfer film on the friction characteristics. The friction material specimens with extra 100% of each ingredient were tested using a pad-on-disk type tribotester. A non-destructive method of measuring the transfer film was developed by considering the electric resistance of the transfer film. Results showed that solid lubricants and iron powder assisted transfer film formation on the rotor surface. Average friction coefficient was independent of transfer film thickness in this experiment. On the other hand, the thick transfer film on the rotor surface reduced the amplitude of friction oscillation under temperature conditions ( 250$^{\circ}C$) that transfer film forms.

  • PDF

Pool Boiling Heat Transfer Coefficient of HFC32/HFC152a on a Plain Surface (평판 표면에서 HFC32/HFC152a 혼합냉매의 풀 비등 열전달계수)

  • Kang, Dong-Gyu;Lee, Yohan;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.484-492
    • /
    • 2013
  • Nucleate pool boiling heat transfer coefficients (HTCs) are measured with HFC32/HFC152a mixture at several compositions. All data are taken at the liquid pool temperature of $7^{\circ}C$, on a horizontal plain square surface of $9.53{\times}9.53$ mm, with heat fluxes of 10 $kW/m^2$ to 100 $kW/m^2$ with an interval of 10 $kW/m^2$, in the increasing order of heat flux. Test results show that the HTCs of these mixtures are up to 45% lower than those of the ideal HTCs calculated by a linear mixing rule with pure fluids' HTCs, due to the mass transfer resistance associated with non-azeotropic refrigerant mixtures. Pool boiling data show the deduction in HTCs with an increase in GTD of the mixture. The present mixture data agree well with five well known correlations, within 20% deviation.

Piezoelectric Characteristics of Pb(Mnsub 1/3Nb 23)Osub 3-Pb(Zr, Ti)Osub 3 Ceramics with $CeO_2$ Impurity for the Piezoelectric Transformer (Cerium Oxide 첨가에 따른 압전트랜스포머용 $Pb(Mn_{1/3}Nb_{2/3})O_3-Pb(Zr,Ti)O_3$ 세라믹의 압전특성)

  • Ryu, Ju-Hyeon;Seo, Seong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.611-615
    • /
    • 1999
  • Piezoelectric properties of PMN-PZT ceramics with $CeO_2$ impurity were investigated. Mechanical quality factor, $Q_m$ of 1792, 1285 and the electromechanical coupling coefficient, $k_p$ of 0.52, 0.54 were obtained from the specimen with 0.25 and 0.5 mole % $CeO_2$ respectively. Curie temperature was decreased with the addition of $CeO_2$ while the electric coercive field was proportional to the amount of impurity. Based on the system ceramics with 0.5 mole % cerium oxide, a Rosen type piezoelectric transformer was fabricated and tested. Voltage step-up ratios of 230 and 13 were obtained from the transformer at no load and $100 k\Omega$ resistance, respectively. Experimental results showed a potential of the transformer for the practical use coupled with the expected strength increase by the grain size refinement.

  • PDF

Fuel flow simulation in globe valve considering variation of viscosity (연료의 점도 변화를 고려한 글로브 밸브 내부 유동 시뮬레이션)

  • Phil Kim;Jeongbeom Heo;Haebeen Kim;Eunseop Yeom
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.3
    • /
    • pp.54-59
    • /
    • 2024
  • Valves are devices used to control or stop the flow of fluids through pipelines. Among them, globe valves with a movable disk or plug experience a significant pressure drop due to the changes in fluid flow direction from horizontal to vertical and back to horizontal. This study analyzes the flow characteristics and cavitation in a globe valve, focusing on the effects of varying fuel viscosity due to changes in pressure and temperature. Simulations were conducted with IFO 380 fuel under constant and variable viscosity conditions. The Realizable k-ε model was applied, and cavitation was simulated through multiphase flow conditions. Results showed that at a 50% valve opening, significant pressure drops and cavitation occurred in narrow regions, while at 100%, pressure changes were more gradual. The WLF-Barus model revealed that higher pressures increased fuel viscosity, reducing cavitation compared to constant viscosity conditions. Flow coefficient (Kv) calculations showed minor differences between constant and variable viscosity, with the variable condition leading to a lower Kv at full valve opening. The study highlights the impact of viscosity changes on flow resistance and cavitation behavior.

Design of Fuse-Link Structure & Fe-Ni Alloy Element's Shape to Increase an Interrupt Rating of a Semi-Enclosed Type Fuse (반밀폐형 퓨즈의 차단용량 상승을 위한 Fe-Ni 합금 가용체의 형상 및 퓨즈링크 구조 설계)

  • Kim, Seong-Ju;Kim, Doe-Hoon;Kang, Chang-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.644-650
    • /
    • 2018
  • According to a miniaturization and integration of electric device, a little size of fuse satisfying the current carrying capacity as well as an explosive tolerance and current interrupt rating are required. Fe-Ni alloy is applied to decrease an oxidation of fuse elements. A resistance and T.C.R(temperature coefficient of resistance) of a fuse are analyzed by changing a content of Ni And full rated current I-T curve from 1A to 6.3A has been tested. In order to an explosive energy, a straight wire type is selected to reduce a fuse melting time. An interrupt rating test was conducted by changing a content of Ni and the optimal content of Ni is to be 40%.

A Propotition of a New Parameter in Ceramic Wear(I) Friction and Wear Characteristics of Silicon Nitride and Zirconia (세라믹 마멸에 있어서의 새로운 파라메터 제안 (I) 질화규소와 지르코니아의 마찰$\cdot$마멸 특성)

  • ;;Hsu, S. M.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1441-1455
    • /
    • 1993
  • Under unlubricated condition, the friction and wear tests of silicon nitride and zirconia manufactured by HIP were carried out at room temperature. The wear resistance of silicon nitride was superior to that of zirconia under low load, whereas the wear resistance of zirconia was superior to that of silicon nitride under high load. Wear model of ceramic was suggested by the microscopic SEM observation of worn surfaces and debris. Theoretical analysis and discussions based on linear fracture mechanics were made out about this ceramic wear model. From the theoretical analysis, a new nondimensional parameter, Scf, was introduced to estimate wear rate of ceramics. This new nondimentional parameter consists of contact pressure, surface defect of contact material, frictional coefficient and fracture toughness.

Experimental Study on Condensation Heat Transfer Characteristics of Special Heat Transfer Tubes (응축용 특수 전열관의 열전달 특성에 관한 연구)

  • 한규일;박종운;권영철;조동현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.827-835
    • /
    • 2001
  • In this study, condensation heat transfer characteristics were conducted with special heat transfer tubes of SH-C type. Experiments were carried out the saturated vapor temperature of 334K and the wall subcooling of 1.5-4.5K. The refrigerant was R-113 and the enhanced tubes used in the present study were SH-CDR, SH-CYR and SH-CHR. The experimental results showed that the condensation heat transfer coefficients of SH-C type tubes were about 23-66% higher than those of a low integral-fin tube. It was visualized that the condensed liquid on the outer surface of SH-C type tubes flowed continuously down unlike a low integral-fin tube and a plain tube, due to a 3-D extending fin on the outer surface of SH-C type tubes. As a result, the thermal resistance of the condensed liquid decreased and the heat transfer coefficient increased. Also, the enhancement ratio of SH-CDR tube was the highest, and it was about 9-11 times as compared to that of a plain tube.

  • PDF