• 제목/요약/키워드: Temperature monitoring system

검색결과 1,139건 처리시간 0.028초

IC 센서를 이용한 고속철도차량 구동장치의 무선 온도 모니터링 시스템 (Wireless Temperature Monitoring of Driving Gear Unit in High Speed Train Using IC Sensor)

  • 권석진;서정원;이동형;황지성
    • 한국정밀공학회지
    • /
    • 제30권7호
    • /
    • pp.673-678
    • /
    • 2013
  • Driving gear units can be affected by various problems, including those associated with external or internal defects in the bearing, problems with the lubricant oil, high-loading of the railway, and frequent impacts generated by rail joints. Temperature monitoring is a basic method in diagnosing abnormal conditions in the reduction gear and other components. This paper describes a new wireless monitoring system for the temperature diagnosis of abnormal conditions of the reduction gear. Integrated circuit (IC)-type temperature sensors were installed in the reduction gear box of a high-speed railway car. The temperature data from the reduction gear were acquired and analyzed in situ during high-speed rail operation. Analysis of these data was used to alert the driver and/or maintenance personnel when problems occurred.

디젤차량용 연료히터의 활성화분석용 데이터 모니터링 장치 (Data Monitoring System for Activation Analysis Based on Fuel Heater of Diesel Cars)

  • 이보희;손병민;조상;윤달환
    • 전기전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.179-184
    • /
    • 2014
  • 겨울철 저온환경에서 디젤 엔진의 점화를 지원하는 통합형연료히터의 활성화분석용 데이터 모니터랑 장치를 개발한다. 디젤엔진의 연료인 경유는 일정한 온도 이하로 내려가면 파라핀과 같은 반고체 상태인 왁싱(Waxing)물질을 형성하여 엔진시동이 잘 걸리지 않는다. 이러한 엔진점화의 시동성능 평가에 중요한 요소로 극저온에서 극고온사이 온도변화에 따른 엔진점화 시간, 히터 저항과 전류에 따른 지연시간 및 유압 등이 있다. 따라서 연료라인과 연료 히터간 활성화 동작을 분석하기 위해 센서 장치를 개발하고, 온도 및 압력 데이터를 모니터링하여 연료히터의 성능을 측정한다. 연료히터 연료라인의 온도와 압력에서 측정된 데이터는 모바일 기기를 사용하여 원격으로 데이터를 수집하고, 데이터 분석을 통해 연료히터의 문제점을 찾을 수 있는 장치의 유용성을 제시한다.

보일러 고온요소의 수명 감시시스템 소프트웨어 개발 (Development of On-line Life Monitoring System Software for High-temperature Components of Power Boilers)

  • 윤필기;정동관;윤기봉
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.171-176
    • /
    • 1999
  • Nondestructive inspection and accompanying life analysis based on fracture mechanics were the major conventional methods for evaluating remaining life of critical high temperature components in power plants. By using these conventional methods, it has been difficult to perform in-service inspection for life prediction. Also, quantitative damage evaluation due to unexpected abrupt changes in operating temperature was almost impossible. Thus, many efforts have been made for evaluating remaining life during operation of the plants and predicting real-time life usage values based on the shape of structures, operating history, and material properties. In this study, a core software for on-line life monitoring system which carries out real-time life evaluation of a critical component in power boiler(high temperature steam headers) is developed. The software is capable of evaluating creep and fatigue life usage from the real-time stress data calculated by using temperature/stress transfer Green functions derived for the specific headers and by counting transient cycles. The major benefits of the developed software lie in determining future operating schedule, inspection interval, and replacement plan by monitoring real-time life usage based on prior operating history.

  • PDF

Measurement of Crystal Formation in Supersaturated Solution

  • Kim, Byung-Chul;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1196-1200
    • /
    • 2003
  • The degree of supersaturation is an important measure for the operation of crystallization processes, because it is directly related to the control of crystal size distribution and shape. A conventional technique utilizing solution composition and temperature has a variety of problems caused from the measurement error and the handling of analyzing samples. A monitoring system of the supersaturation using a quartz crystal sensor is proposed here, and its performance is examined applying different manipulations of coolant temperature. The experimental outcome and photographic examination indicate that the measurements of resonant frequency and resistance of the sensor can be used for the prediction of the formation and growth of solid crystal from the crystallization process. The monitoring system eliminates the intrinsic error source of the conventional system to give the improved measurement and on-line application availability.

  • PDF

지하대기중의 CO 및 $CO_2$의 일변화 특성에 관한 연구 (On the Diurnal Variations of CO and $CO_2$ in the Underground Atmospheric Environments)

  • 이동인;이지연
    • 한국환경과학회지
    • /
    • 제3권4호
    • /
    • pp.381-391
    • /
    • 1994
  • This paper presents the disributions and variations of CO, $CO_2$, number of people and temperature in underground shopping center and subway of Seomyeon and Jagalchi in Pusan, Korea for two times during October and November in 1993, respectively. NDIR analyzer is used for the analysis of CO and $CO_2$. The temperature is obtained from a mercury therometer. The results o( observation and analysis show that the variation of $CO_2$ is strongly related to number of people and temperature. The correlation coefficients between temperature, COB and Number of people are higher than 0. at both of places. The pollution of CO2 of Seomyeon is higher than that of Jagachi in underground shopping center. However, CO is not correlated with the temperature and the Number of people. From the results, we found that the indoor air quality monitoring system is needed for the prevention of the underground air Pollution.

  • PDF

Methods and Systems for High-temperature Strain Measurement of the Main Steam Pipe of a Boiler of a Power Plant While in Service

  • Guang, Chen;Qibo, Feng;Keqin, Ding
    • Journal of the Optical Society of Korea
    • /
    • 제20권6호
    • /
    • pp.770-777
    • /
    • 2016
  • It has been a challenge for researchers to accurately measure high temperature creep strain online without damaging the mechanical properties of the pipe surface. To this end, a noncontact method for measuring high temperature strain of a main steam pipe based on digital image correlation was proposed, and a system for monitoring of high temperature strain was designed and developed. Wavelet thresholding was used for denoising measurement data. The sub-pixel displacement search algorithm with curved surface fitting was improved to increase measurement accuracy. A field test was carried out to investigate the designed monitoring system of high temperature strain. The measuring error was less than $0.4ppm/^{\circ}C$, which meets actual measurement requirements for engineering. Our findings provide a new way to monitor creep damage of the main steam pipe of a boiler of an ultra-supercritical power plant in service.

극지환경을 고려한 남극 세종과학기지 계측시스템 적용성에 관한 연구 (A Study of Applicability of Monitoring System through Polar Environment around the King Sejong Station, Antarctica)

  • 박근보;김영석
    • 한국지반신소재학회논문집
    • /
    • 제12권2호
    • /
    • pp.43-53
    • /
    • 2013
  • 극한환경에서의 구조물 거동을 파악하기 위하여 남극 세종과학기지 부근의 기상환경을 분석(1988년-2007년 및 2010년)하고, 이에 적합한 상용화된 계측기를 선정하여 남극기지(생물해양연구동)에 설치하여 검토하였다. 남극 세종과학기지 기상환경분석결과, $-25.6^{\circ}C$ 이하의 온도 및 49.5m/s정도의 바람에도 견딜 수 있는 계측기를 설치해야 하며 설치위치도 지표면에서 225.0cm 이상이어야 한다. 또한, 남극에서 사용할 계측기 센서의 경우 온도, 폭설 및 강풍에 민감하고, 기상환경 이외에 남극의 동물이 침범할 수 있으므로 계측기 및 계측기용 데이터로거를 보호할 수 있는 시스템을 개발하여 적용하였다. 새롭게 개발된 보호시스템은 극한환경에서도 설치가 용이하고 경제적이다. 1년간의 계측결과를 바탕으로 보호시스템의 극지 적용가능성을 검토하였으며, 구조물 거동도 예측이 가능함을 확인하였다.

홈 헬스케어를 위한 다채널 생체신호 모니터링 시스템 구현 (Implementation of the Multi-channel Vital Signal Monitoring System for Home Healthcare)

  • 윤정윤;정도운
    • 융합신호처리학회논문지
    • /
    • 제11권3호
    • /
    • pp.197-202
    • /
    • 2010
  • 본 논문에서는 가정 내에서 보다 편리하게 건강모니터링을 수행하기위한 홈헬스케어용 다중생체 계측시스템을 구현하였다. 측정대상 신호는 가정 내에서 일반인들이 쉽게 측정할 수 있으며 많은 건강정보를 포함하고 있는 심전도, 맥파 그리고 체온을 대상으로 하였다. 구현된 생체계측 시스템은 신호검출을 위한 센서부, 각각의 생체신호를 증폭 및 필터링하기 위한 아날로그 신호처리부, 아날로그신호를 디지털로 변환하여 처리하고 시스템 주변장치를 제어하기위한 시스템제어부 및 모니터링 프로그램으로 구성되었다. 구현된 시스템은 시스템자체에서의 디스플레이뿐만 아니라 블루투스무선통신을 통해 홈서버용 PC 또는 웹을 통해 원격모니터링이 가능하여 원격건강정보 모니터링에 활용이 가능하다. 구현된 생체신호 계측시스템의 성능평가 결과 실제 홈 헬스케어에 적용 가능성을 확인하였다.

Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant

  • Heo, Taehoon;Cho, Seung Hyun
    • Nuclear Engineering and Technology
    • /
    • 제48권6호
    • /
    • pp.1404-1411
    • /
    • 2016
  • Pipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online thickness monitoring is necessary to avoid abrupt breakage due to wall thinning. To this end, a transducer that can withstand a high-temperature environment and should be installed under the insulation layer. We propose a thin plate type of embedded ultrasonic transducer based on magnetostriction. The transducer was designed and fabricated to measure the thickness of a pipe under a high-temperature condition. A number of experimental results confirmed the validity of the present transducer.

보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법 (Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers)

  • 정재진;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF