• Title/Summary/Keyword: Temperature imaging

Search Result 684, Processing Time 0.026 seconds

Fabrication of $Gd_2O_3:Eu^{3+}$ Nano Phosphor and Optical Characteristics for High Resolution Radiation Imaging (고해상도 방사선 영상을 위한 $Gd_2O_3:Eu^{3+}$ 나노 형광체 제조 및 광학적 특성)

  • Kim, So-Yeong;Kang, Sang-Sik;Park, Ji-Koon;Cha, Byung-Youl;Choe, Chi-Won;Lee, Hyung-Won;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.148-152
    • /
    • 2007
  • In this paper, we have synthesized $Gd_2O_3:Eu^{3+}$ nano phosphor particle using a low temperature solution-combustion method. We have investigated the structure and the luminescent characteristic as the sintering temperature and europium concentration. From XRD(X-ray diffraction) and SEM(scanning electron microscope) results, we have verified that the phosphor particle was fabricated a spherical shape with $30{\sim}40nm$ particle size. From the photoluminescence results, the strong peak exhibits at 611 um and the luminescent intensity depends on europium concentration. $Gd_2O_3:Eu$ fine phosphor particle has shown excellent luminescent efficiency at 5 wt% of europium concentration. The phosphors calcinated at $500^{\circ}C$ have possessed the x-ray peaks corresponding to the cubic phase of $Gd_2O_3$. As calcinations temperature increased to $700^{\circ}C$, the new monoclinic phase has identified except cubic patterns. From the luminescent decay time measurements, mean lifetimes were $2.3{\sim}2.6ms$ relatively higher than conventional bulk phosphors. These results indicate that $Gd_2O_3:Eu$ nano phosphor is possible for the operation at the low x-ray dose, therefore, the application as medical imaging detector.

New Non-uniformity Correction Approach for Infrared Focal Plane Arrays Imaging

  • Qu, Hui-Ming;Gong, Jing-Tan;Huang, Yuan;Chen, Qian
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.213-218
    • /
    • 2013
  • Although infrared focal plane array (IRFPA) detectors have been commonly used, non-uniformity correction (NUC) remains an important problem in the infrared imaging realm. Non-uniformity severely degrades image quality and affects radiometric accuracy in infrared imaging applications. Residual non-uniformity (RNU) significantly affects the detection range of infrared surveillance and reconnaissance systems. More effort should be exerted to improve IRFPA uniformity. A novel NUC method that considers the surrounding temperature variation compensation is proposed based on the binary nonlinear non-uniformity theory model. The implementing procedure is described in detail. This approach simultaneously corrects response nonlinearity and compensates for the influence of surrounding temperature shift. Both qualitative evaluation and quantitative test comparison are performed among several correction technologies. The experimental result shows that the residual non-uniformity, which is corrected by the proposed method, is steady at approximately 0.02 percentage points within the target temperature range of 283 K to 373 K. Real-time imaging shows that the proposed method improves image quality better than traditional techniques.

Measurement of Temperature Distribution in the Infrared Panel Heater (적외선 패널히터의 온도분포 측정)

  • Lee, Kong-Hoon;Ha, Su-Seok;Kim, Ook-Joong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1178-1183
    • /
    • 2004
  • Temperature distribution and heating characteristic of the panel heater for infrared heating have been investigated. The temperature variation with time is firstly measured with the thermocouple to figure out the response time of the heater to the power input. The heater reaches faster to the steady state in comparison to the ceramic heater. The infrared thermal imaging system is utilized to investigate the temperature distribution over the heater surface. The measured thermal images show that the thermal boundary layer induced by the free convection near the heater surface affects the temperature distribution on the surface. The images also show the fairly good uniformity of the temperature distribution in the core region of the surface.

  • PDF

Development of Fuzzy Inference-based Deterioration Diagnosis System Using Infrared Thermal Imaging Camera (적외선 열화상 카메라를 이용한 퍼지추론 기반 열화진단 시스템 개발)

  • Choi, Woo-Yong;Kim, Jong-Bum;Oh, Sung-Kwun;Kim, Young-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.912-921
    • /
    • 2015
  • In this paper, we introduce fuzzy inference-based real-time deterioration diagnosis system with the aid of infrared thermal imaging camera. In the proposed system, the infrared thermal imaging camera monitors diagnostic field in real time and then checks state of deterioration at the same time. Temperature and variation of temperature obtained from the infrared thermal imaging camera variation are used as input variables. In addition to perform more efficient diagnosis, fuzzy inference algorithm is applied to the proposed system, and fuzzy rule is defined by If-then form and is expressed as lookup-table. While triangular membership function is used to estimate fuzzy set of input variables, that of output variable has singleton membership function. At last, state of deterioration in the present is determined based on output obtained through defuzzification. Experimental data acquired from deterioration generator and electric machinery are used in order to evaluate performance of the proposed system. And simulator is realized in order to confirm real-time state of diagnostic field

Foreign Development Status and Applications of Infrared Imaging Satellite (해외 적외선 관측위성 현황 및 영상활용)

  • Kim, Eung-Hyun;Im, Jung-Heum;Kim, Hee-Seop;Kim, Gyu-Sun
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.2
    • /
    • pp.51-59
    • /
    • 2008
  • While the infrared imaging satellites with the several type were developed and operated in the foreign countries, we do not have the domestic infrared imaging satellite up to now. In the paper, the general characteristics of infrared and the applications of infrared image were introduced. Also the oversea development status of the infrared imaging satellite was surveyed and introduced to this paper. According to foreign status, the infrared image is utilized in various application including the forest fire monitoring, the volcano activity research, sea surface temperature measurement, land surface temperature calculation, the climate change research, and the environment monitoring. According to these trend the development of the domestic infrared imaging satellite in low earth orbit was required.

  • PDF

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

Autofocusing Mechanism of a Triple-Magnification Infrared System (3중 배율 적외선 영상 장비의 자동 초점 조절 방안)

  • Jung, Hyojung;Jeong, Suseong;Yang, Yunseok;Lee, Yongchun;Han, Jeongsu
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.314-320
    • /
    • 2020
  • The optics used in an infrared imaging system has a strong refractive-index change according to temperature, so an autofocus control function is essential for a military infrared imaging system with a wide operating-temperature range. In this study, we design a triple-magnification infrared imaging system, and to compensate for the change in refractive index according to temperature we measure the change in the lens focus according to temperature. The autofocus control function was implemented by using the measured movement amount, and we could obtain an image with satisfactory resolution performance over a wide range of operating temperatures.

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

An Experimental Study on the Estimation of Sol-air Temperature and Absorptance in Building Exterior Materials by Using the Infrared Image (적외선 열화상을 이용한 건축외장재의 일사표면온도와 흡수율 추정에 관한 실험적 연구)

  • Park, Sa-Keun;Jang, Gil-Soo;Song, Min-Jeong;Shin, Hoon
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.33-39
    • /
    • 2006
  • This study aims to investigate the method to reduce the surface temperature caused by insolation. To achieve this goal, surface temperature of building is measured and the effects of exterior material's color and brilliance were checked with infrared imaging. And also, exterior material's absorptances due to outdoor surface heat transfer coefficients were measured. After surface temperature measurement of 37 specimen of 5 categories, the temperature is the highest on wood($53.62^{\circ}C$) and panel($52.05^{\circ}C$). Dryvit, stone, brick is the rating of order. For exterior material's absorptances, panel(0.883) and wood(0.868) were high and Dryvit, stone, brick follows wood and panel.

Imaging and Manipulation of Benzene Molecules on Si Surfaces Using a Variable-low Temperature Scanning Tunneling Microscope

  • Hahn, J. R.
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.7
    • /
    • pp.1071-1074
    • /
    • 2005
  • A variable-low temperature scanning tunneling microscope (VT-STM), which operates from 77 to 350 K in ultrahigh vacuum, was built and used to study imaging and manipulation of benzene molecules on Si surfaces. Four types of benzene adsorption structures were first imaged on the Si(5 5 12)-2x1 surface. Desorption process of benzene molecules by tunneling electrons was studied on the Si(001)-2xn surface.