• 제목/요약/키워드: Temperature fields

검색결과 1,715건 처리시간 0.031초

무우 배추 포장내의 병원성 토양미생물 소장 (The fluctuation of soil pathogenic microbes population in radish and chinese cabbage fields)

  • 이왕휴;소인영
    • 미생물학회지
    • /
    • 제21권1호
    • /
    • pp.7-14
    • /
    • 1983
  • In order to study the effects of cropping system and fungicide (Dachigaren) on soil microbes, the seasonal fluctuations of soil microbes in the fields of radish and Chinese cabbage including soil pH, Soil moisture content and soil temperature were investigated on every 15 day interval from the begining of March to late October in 1981. The population of total fungus peaked at the begining of July, while that of total bacteria, at the begining of August. They were affected by soil temperature, however pathogenic microbes seemed to be more related with host plants than the soil temperature, because pathogens showed high density through the whole cultivation period. The pathogenic microbes showed the density of order ; Xanthomonas, Erwinia, Pseudomonas, Agrobacterium and Corynebacterium. Xanthomonas, Erwinia and Pseudomonas, which induced radish and Chinese cabbage diseases were higher than Agrobacterium and Corynebacterium in population densigy. Bacterial soft rot occured at the density of Erwinia $5.9{\sim}6.6{\times}10^5/dry$ soil 1 gram. The density of microbes on continuous fields were higher than that of rotating fields, but there were no significant difference between treated fungicide plot and non treated in the density of microbes, also no difference between Chinese cabbage and radish growing fields.

  • PDF

인삼의 온도에 대한 생리반응 II. 엽의 생리, 지온, 기온, 병환의 생육 (Physiological Response of Panax Ginseng to Tcmpcrature II. Leaf physiology, soil temperature, air temperature, growth of pathogene)

  • 박훈
    • Journal of Ginseng Research
    • /
    • 제4권1호
    • /
    • pp.104-120
    • /
    • 1980
  • The effects of temperature on transpiration, chlorophyll content, frequency and aperture of stomata, and leaf temperature of Panax ginseng were reviewed. Temperature changes of soil and air under spade roof were also reviewed. Growth responses of responses of ginseng plant at various temperature were assessed in relation to suseptibillity of ginseng plants. Reasonable management of ginseng fields was suggested based on the response of ginseng to various temperatures. Stomata frequency may be increased under high temperature during leaf$.$growing stage. Stomata aperture increased by high temperature but the increase of both frequency and aperture appears not enough for transpiration to overcome high temperature encountered during summer in most fields. Serial high temperature disorder, i.e high leaf temperature, chlorophyll loss, inhibition of photosynthesis, increased respiration and wilting might be alleviated by high humidity and abundant water supply to leaf. High air temperature which limits light transmission rate inside the shade roof, induces high soil temperature(optimum soil temperature 16∼18$^{\circ}C$) and both(especially the latter) are the principal factors to increase alternaria blight, anthracnose, early leaf fall, root rot and high missing rate of plant resulting in poor yield. High temperature disorder was lessen by abundant soil water(optimum 17∼21%) and could be decreased by lowering the content of availability of phosphorus and nitrogen in soil consequently resulting in less activity of microorganisms. Repeated plowing of fields during preparation seems to be effective for sterilization of pathogenic microoganisms by high soil temperature only on surface of soils. Low temperature damage appeared at thowing of soils and emergence stage of ginseng but reports were limited. Most limiting factor of yield appeared as physiological disorder and high pathogen activity due to high temperature during summer(about three months).

  • PDF

온도감응형 인광물질을 이용한 온도장 및 열변형 동시 계측 기법 개발 (Development of a multi-sensing technique for temperature and strain field of high-temperature using thermographic phosphors)

  • 임유진;염은섭
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.77-83
    • /
    • 2021
  • Solid oxide fuel cell (SOFC) operates at high temperatures in range of 600-800℃. Since layers of SOFC are composed of different substances, different thermal expansion in SOFC can result in defects under high temperature conditions. For understanding relation between temperature field and the thermal deformation in SOFC, temperature and strain field were simultaneously estimated using thermographic phosphors by optical measurement. Temperature fields were obtained by the life-time method, and the temperature differences of one specimen was checked with thermocouple. The thermal deformation was estimated by digital image correlation (DIC) method with extracted phosphorescence images. To investigate the deformation accuracy of DIC measurement, thermographic phosphors were coated with and without grid pattern on aluminum surface. Simultaneous measurement of temperature fields and thermal deformation were carried out for YSZ. This study will be helpful to multi-sensing of temperature field and thermal deformation on SOFC cells.

반경방향으로의 온도구배가 Taylor Vortex에 미치는 영향에 대한 수치적 연구 (Numerical Study of Radial Temperature Gradient Effect on Taylor Vortices)

  • 강창우;양경수;윤동혁
    • 대한기계학회논문집B
    • /
    • 제33권11호
    • /
    • pp.900-908
    • /
    • 2009
  • Numerical simulation has been carried out to investigate the influence of radial temperature gradient on the Taylor Vortex flow. Varying the Grashof number, we study the detailed flow and temperature fields. The current numerical results show good agreement with the experimental results currently available. It turns out that wavy spiral vortices are generated by increasing temperature gradient. We classify flow patterns for various Grashof numbers based on the characteristics of flow fields and spiral vortices. The correlation between Grashof number with wave number shows that the spiral angle and size of Taylor vortices increase with increasing temperature gradient. Temperature gradient does not have a great influence on the heat transfer rate of the cylinder surfaces.

MCCB 내의 온도장에 대한 수치적 연구 (A Numerical Study on Temperature Fields in MCCB)

  • 박성규;이종철;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.145-150
    • /
    • 2003
  • In this paper we have studied the characteristics of temperature fields in a Molded Case Circuit Breaker (MCCB). A switch and a trip device are arranged in narrow space of the MCCB. Thus, thermal factors have been risen to important problem. The temperature rise means an energy loss and it becomes the reason of fatal fault in devices. Also, the temperature rise on the connection and the contact parts is regulated up to $115^{\circ}C$ and $105^{\circ}C$, respectively. Therefore, a study for preventing the temperature rise should be investigated. A numerical analysis method that has confidence might be preceded for this purpose. In order to verify the confidence of temperature field analysis, the results of the numerical analysis are compared with those of experimental one for the same model. Comparison results show a qualitatively good agreement within ${\pm}5%$ errors.

  • PDF

반원관내 자성유체의 자연대류에 관한 연구 (A Study on the Flow Behavior of Magnetic Fluids in a half Circular Pipe)

  • 황성욱;박정우;서이수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3098-3103
    • /
    • 2007
  • In this paper, natural convection of a magnetic fluids(W-40) in a half circular pipe enclosure are investigated by numerical and experimental method. One side wall is kept at a constant temperature(25$^{\circ}C$), and the opposite side wall is also kept at a constant temperature(20$^{\circ}C$). Under above conditions, various magnitudes of the magnetic fields were applied up. Theoretical study through the governing equation derived by Siliomis is carried out with numerical analysis by the GSMAC Method. And the thermo-sensitive liquid crystal film(R20C5A) is utilized in order to visualize wall-temperature distributions as an experimental method. This study has resulted in the following fact that the natural convection of a magnetic fluids are controlled by the direction and intensity of the magnetic fields.

  • PDF

차량 엔진룸에서의 냉각효율 향상에 관한 해석 (ANALYSIS OF THE ENHANCEMENT OF COOLING EFFICIENCY OF A VEHICLE IN THE ENGINE ROOM)

  • 이동렬
    • 한국전산유체공학회지
    • /
    • 제10권3호
    • /
    • pp.55-62
    • /
    • 2005
  • Flow and temperature fields of a mid-size vehicle engine room are examined numerically to analyze the enhancement of cooling efficiency of several different design cases in a front body shape. The wall temperatures of a radiator and an engine parte are utilized to predict the effects of engine cooling on the thermal environment and the cooling efficiency in an engine room. The analyzed results are the mass flow rate at the upper and lower inlets, in the radiator, and the condenser. It is shown that the shape of the front end, lay-out of the engine parts, and the presence of the undercover greatly influence the flow and temperature fields, and the enhancement of cooling efficiency in the engine room.

사각 물체가 존재하는 2차원 Benard 자연 대류 (Two-Dimensional Benard Natural Convection with a Rectangular Body)

  • 윤경수;하만영;윤현식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.282-289
    • /
    • 2000
  • Direct numerical solution for flow and heat transfer for Benard convection with a body is obtained using an accurate and efficient Fourier-Chebyshev collocation and multi-domain method. The flow and temperature fields are obtained fur different Rayleigh numbers and thermal boundary conditions of body. The body has adiabatic and constant temperature conditions. The existence of a body gives different flow and heat transfer fields in the system, compared to pure Benard convection. The flow and temperature fields are also affected by the thermal boundary condition of a body.

  • PDF

Multi-physics Analysis for Temperature Rise Prediction of Power Transformer

  • Ahn, Hyun-Mo;Kim, Joong-Kyoung;Oh, Yeon-Ho;Song, Ki-Dong;Hahn, Sung-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.114-120
    • /
    • 2014
  • In this paper, a method for multi-physics analysis of the temperature-dependent properties of an oil-immersed transformer is discussed. To couple thermal fields with electromagnetic and fluid fields, an algorithm employing a user defined function (UDF) is proposed. Using electromagnetic analysis, electric power loss dependent on temperature rise is calculated; these are used as input data for multi-physics analysis in order to predict the temperature rise. A heat transfer coefficient is applied only at the outermost boundary between transformer and the atmosphere in order to reduce the analysis region. To verify the validity of the proposed method, the predicted temperature rises in high-voltage (HV) and low-voltage (LV) windings and radiators were compared with the experimental values.

기온감률 효과 적용에 따른 공간내삽기법의 기온 추정 정확도 비교 (Accuracy Comparison of Air Temperature Estimation using Spatial Interpolation Methods according to Application of Temperature Lapse Rate Effect)

  • 김용석;심교문;정명표;최인태
    • 한국기후변화학회지
    • /
    • 제5권4호
    • /
    • pp.323-329
    • /
    • 2014
  • Since the terrain of Korea is complex, micro- as well as meso-climate variability is extreme by locations in Korea. In particular, air temperature of agricultural fields is influenced by topographic features of the surroundings making accurate interpolation of regional meteorological data from point-measured data. This study was carried out to compare spatial interpolation methods to estimate air temperature in agricultural fields surrounded by rugged terrains in South Korea. Four spatial interpolation methods including Inverse Distance Weighting (IDW), Spline, Ordinary Kriging (with the temperature lapse rate) and Cokriging were tested to estimate monthly air temperature of unobserved stations. Monthly measured data sets (minimum and maximum air temperature) from 588 automatic weather system(AWS) locations in South Korea were used to generate the gridded air temperature surface. As the result, temperature lapse rate improved accuracy of all of interpolation methods, especially, spline showed the lowest RMSE of spatial interpolation methods in both maximum and minimum air temperature estimation.