• Title/Summary/Keyword: Temperature field measurement

Search Result 614, Processing Time 0.028 seconds

Ferromagnetic Domain Behaviors in Mn doped ZnO Film

  • Soundararajan, Devaraj;Santoyo-Salazar, Jaime;Ko, Jang-Myoun;Kim, Ki-Hyeon
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.216-219
    • /
    • 2011
  • Mn doped ZnO films were prepared on Si (100) substrates using sol-gel method. The prepared films were annealed at 550C for decomposition and oxidation of the precursors. XRD analysis revealed the presence of ZnMnO hexagonal wurtzite phase along with the presence of small quantity of ZnMn2O3 secondary phase and poor crystalline nature. The 2D, 3D views of magnetic domains and domain profiles were obtained using magnetic force microscopy at room temperature. Rectangular shaped domains with an average size of 4.16 nm were observed. Magnetic moment measurement as a function of magnetic field was measured using superconducting quantum interference device (SQUID) magnetometry at room temperature. The result showed the ferromagnetic hysteresis loop with a curie temperature higher than 300 K.

Pressure-Temperature Phase Diagram of (TMTSF)2BF4 ((TMTSF)2BF4의 압력-온도 상태도 연구)

  • Jo, Y.J.
    • Progress in Superconductivity
    • /
    • v.14 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • (TMTSF)2BF4 containing non-centrosymmetric anions is well known to exhibit a metal insulator transition around 37 K by ordering of the anions with a q2=(1/2, 1/2, 1/2) wave vector. We established pressure-temperature phase diagram of the (TMTSF)2BF4 compound and showed that it can belong to the general phase diagram of the (TMTSF)2X family. Application of hydrostatic pressure decreases the anion ordering transition temperature and the superconducting state is finally stabilized below 3.77 K under 7.7 kbar. Magnetoresistance measurement on the (TMTSF)2BF4 under 7.8 kbar is performed but neither the field-induced spin-density-wave state nor the rapid oscillation is observed up to 9 T.

Measurement and Analysis of Free Water Evaporation at HaeNam Paddy Field (해남 농경지에서의 자유 수면 증발 관측과 해석)

  • Han Jin-Su;Lee Bu-Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.91-97
    • /
    • 2005
  • Class A evaporation pan has been used throughout the world to measure free water evaporation mainly by manual observation once a day. In this study, a new automatic water level measurement method is used for understanding of free water evaporation and numerical analysis. This new technique measures the weight of buoyancy bar in water, and does not need calibration because it is not affected by water density change with water temperature. Field observations of evaporation were made near Haenam Meteorological Station over paddy field located in southwestern Korea from 20 April to 30 May 2004 and the data from ten clear days (16 - 25 May) were used for this analysis. The observed total evaporation was about 50.7mm during this period whereas the estimated from an empirical equation was 50.4mm. As expected, the pan evaporation is well correlated with wind speed and the vapor pressure deficit between the water surface and the air.

A Study on the Airflow near the Cold Heat Source Using CFD in Merchandising Store (CFD를 이용한 대형매장 냉열원 주변의 공기유동에 관한 연구)

  • Cho Sung Woo;Park Min Young;Im Young Bin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.629-634
    • /
    • 2005
  • This paper performed to predict vertical temperature distribution and air flow near cold heat source in the mass merchandising store. At the height of 150 cm, the vertical air temperature difference between the results of CFD and of measurement field showed 10% near the refrigeration zone and 8.8% near the freezing zone. Therefore, it regarded as appropriate for the using CFD to investigate airflow near the heat sources. The 3 kinds of CFD model were divided by the disposition of diffuser/exhaust and diffuser air temperature. At the refrigeration and freezing zone in the Model 2 and 3, the temperature difference between the front and the back of human model were showed 6.8Cand3.9C with diffuser air temperature 17C and were showed 6.8C and 4C with diffuser air temperature 19C.

Performance Test of Turbine Flowmeter According to Temperature Variation (온도변화에 따른 터빈유량계의 성능 시험)

  • Nam, Ki Han;Park, Jong Ho;Kim, Hong Jip
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.2
    • /
    • pp.47-52
    • /
    • 2017
  • In general industry, TFM(turbine flow meters) as measuring instruments having high reliability are widely used in the trade of petroleum and in the measurement of tap water and hot water. The TFM is performed calibration for using in the field and is mainly calibrated at room temperature. Since accuracy of TFM depends on Reynolds number of fluid, TFM is calibrated at same Reynolds number by changing flow rate. Furthermore, the TFM using a fluid of high temperature should have considered for other factors such as the thermal expansion of the parts and characteristics change is unknown changes in the turbine flow meter accordingly. In this paper, two turbine flowmeter are experimentally studied about characteristics change using the facilities which can change fluid temperature from 6 degree celsius to 90 degree celsius. As a result, the turbine flow meter can be calibrated to minimize the error characteristic at a similar temperature and the actual temperature.

Characteristics of Temperature Variation to the Piezoelectric Bimorph for Vortex Flowmeter (와류 유량센서용 압전 바이몰프의 온도변화에 따른 특성)

  • Lee, Guen-Taek;Kim, Hyung-Sun;Im, Jong-In
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.289-292
    • /
    • 2007
  • Although piezoelectric bimorph that is using as the sensor in medical and industrial measurement has large displacement, it has problems including efficiency in generating force, energy convergence, and response. Its application is being limited based on the change in resonance frequency with temperature. In this study, to overcome the disadvantages, PZT piezoelectric ceramics was prepared and produced a parallel type piezoelectric bimorphs. In addition, by using the finite element method. the configuration of piezoelectric bimorph was designed and the displacement of the bimorph based on applied electric pressure and the wave pattern were measured. By analyzing the resonance characteristics of the bimorph in the temperature range of 6080C, an attempt was made to study the operational characteristics and temperature reliability of vortex flowmeter sensor. As a result, the resonance frequency of the bimorph was gradually increased with the temperature from 6080C. The deflection of the bimorph was found to strongly depend on both the applied electric field waveform and the environmental temperature.

Crystallographic and Magnetic Properties of Cu0.1Fe0.9Cr2S4 (Cu0.1Fe0.9Cr2S4의 결정학적 및 자기적 성질에 관한 연구)

  • Son, Bae-Soon;Kim, Sam-Jin;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.1
    • /
    • pp.33-37
    • /
    • 2004
  • Cu0.1Fe0.9Cr2S4 has been studied with Mossbauer spectroscopy, x-ray diffraction, vibrating sample magnetometer (VSM), and magnetoresistance (MR) measurement. The crystal structure was determined to be a cubic spinel with lattice parameter a0=9.9880 \AA. The MR measurements show a semiconductor behavior below 110 K and metal behaved above 100 K. The temperature dependence of magnetization of Cu0.1Fe0.9Cr2S4 was reported. In addition to a large irreversibility between the zero-field-cooling (ZFC) and the field-cooling (FC) magnetization at applied field H=100 Oe, a cusp-like anomaly was observed in both the FC and ZFC curves. It shifted toward the lower temperature region with increasing magnetic field, and then showed convex type maximum at 110 K, under the applied field of 5 kOe. The Mossbauer spectra were measured from 15 K to room temperature. The asymmetric line broadening was observed for the sample Cu0.1Fe0.9Cr2S4, and it was considered to be dynamic Jahn-Teller relaxation. The charge state of Fe ions was ferrous in character. The unusual reduction of magnetic hyperfine field below 110 K was interpreted in terms of cancellation effect between the mutually opposite orbital current field (HL) and Fermi contact field (HC).

Birefringence measurements of lmol%Mg:LiNbO3 with Noncollinea­rphase­matching cone

  • Lee, Jong-Soo;Rhee, Bum-Ku;Joo, Gi-Tae
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.54-57
    • /
    • 1998
  • A noncollinear-phase-matching cone of second harmonic generation(SHG) was observed in a LiNbO3 crystal doped with l mol% MgO. Birefringence refractive indices can be accurately evaluated by analysing the temperature phase matching characteristic for SHG combined with the measurement of the half cone angle. The electro-optic coefficient can also be determined form the observed change of the half cone angle when a DC electric field is applied along the optic axis.

Prediction of Turbulent Premixed Flamefield in Bunsen Burner (Bunsen Buner 난류 예혼합 화염장의 해석)

  • Cho, Ji-Ho;Kim, Hoo-Joong;Kim, Yong-Mo
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.195-199
    • /
    • 2003
  • The stoichiometric methan/air premixed turbulent flames at the axisymmetric Bunsen burner situation are numerically investigated. To account for the chemistry-turbulence interaction in the turbulent premixed flames, the steady laminar flamelet library method has been adopted. The flame front is tracked by using the Level-Set Approach. Turbulence is represented by the κε modeling with a Pope's correction. The detailed comparison between prediction and measurement has made for the flame field in terms of velocity, turbulent kinetic energy, and normarlized temperature.

  • PDF

Development of a radiation thermometer for the adaptive steel plant (제철소 적응형 복사온도계 개발)

  • Park, Sang-Gug
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.173-178
    • /
    • 2002
  • In this research, we have worked about the radiation thermometer which can be applied to the hazard circumstance such as steel plant. In the results, we have developed radiation thermometer of a measuring range 5001500C, accuracy ±0.1, repeatability ±0.1, resolution 0.2C. We performed extensive field test for 6 months at the hot strip mill in steel plant. Through the test, we have confirmed the reliability of the developed pyrometer.

  • PDF