• 제목/요약/키워드: Temperature field measurement

검색결과 614건 처리시간 0.035초

Temperature distribution prediction in longitudinal ballastless slab track with various neural network methods

  • Hanlin Liu;Wenhao Yuan;Rui Zhou;Yanliang Du;Jingmang Xu;Rong Chen
    • Smart Structures and Systems
    • /
    • 제32권2호
    • /
    • pp.83-99
    • /
    • 2023
  • The temperature prediction approaches of three important locations in an operational longitudinal slab track-bridge structure by using three typical neural network methods based on the field measuring platform of four meteorological factors and internal temperature. The measurement experiment of four meteorological factors (e.g., ambient temperature, solar radiation, wind speed, and humidity) temperature in the three locations of the longitudinal slab and base plate of three important locations (e.g., mid-span, beam end, and Wide-Narrow Joint) were conducted, and then their characteristics were analyzed, respectively. Furthermore, temperature prediction effects of three locations under five various meteorological conditions are tested by using three neural network methods, respectively, including the Artificial Neural Network (ANN), the Long Short-Term Memory (LSTM), and the Convolutional Neural Network (CNN). More importantly, the predicted effects of solar radiation in four meteorological factors could be identified with three indicators (e.g., Root Means Square Error, Mean Absolute Error, Correlation Coefficient of R2). In addition, the LSTM method shows the best performance, while the CNN method has the best prediction effect by only considering a single meteorological factor.

전력구 내 전자기파에 대한 작업 환경 측정 (The Measurement of Electromagnetic Wave in Power Cable Tunnel of Underground Utility Tunnel)

  • 강대곤;박재학
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Electromagnetic measurements of the power cable tunnel were conducted from August 10 to 20, 2018, in the city underground utility tunnel. During this period, the average temperature was 31.89C31.89C and the humidity was 67.56% in power cable tunnel. As a result of the electromagnetic measurement, the highest electric field was 25.3 V/m and the magnetic flux density was 42.6μT42.6μT. The average electric field was 18.56 V/m and the magnetic flux density was 29.32μT29.32μT in the power cable tunnel. As a result of comparison with the electric equipment technical standard, the electric field in the power cable tunnel was 0.5% of the electric equipment standard and 35.2% of the magnetic flux density. It's similar value that electric field is about robotic vacuum(15.53 V/m), and magnetic flux density is similar value about capsule- type coffee machine (23.07μT23.07μT). The number of cable lines and the size of the electromagnetic waves were not proportional to each other through comparison of cable lines in the power cable tunnel. It was confirmed that 154 kV, rather than 22.9 kV, could have a greater influence on occupational.

현장측정을 통한 대형 할인매장의 실내환경 평가 (Evaluation of Indoor Environment Characteristics through Field Measurement in Large-sized Discount Stores)

  • 박병윤;정용호;함흥돈;손장열
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.863-872
    • /
    • 2005
  • It is important to control indoor environment for influence on health and comfort of occupants in large-sized discount stores. On the other hand large-sized discount stores have a large number of visitors, vestibules, open spaces, high energy consumption and increasing of outside air intake. This study aims to offer the design data of building services system that can save energy and control environment through field measurement selecting two large-sized discount stores. Indoor environment factors such as temperature, relative humidity, air velocity and concentrations of CO2CO2, CO gas and TSP were measured and evaluated. In each case of CO2CO2, and CO gas, its maximum values were 2,800 ppm and 20 ppm. So proper strategy for the indoor air quality is indispensable in this type of building. Dry bulb temperature varies from 18C18C to 28C28C according to a measuring point and time. From this results, it is inferred these buildings had excessive equipment capacity. In terms of economical and environmental points, these data will be utilized to the design of HVAC system of retail facilities.

Electron field emission from various CVD diamond films

  • Usikubo, Koji;Sakamoto, Yukihiro;Takaya, Matsufumi
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.385-388
    • /
    • 1999
  • Electron field emission properties from various CVD diamond films were studied. Diamond films were synthesized by microwave plasma CVD at 1173K and at 673K substrates temperature and pulse microwave plasma CVD at 1173K. B-doped diamond film was synthesized by microwave plasma CVD at 1173K also. Estimation by SEM, both the non-doped diamond film and B-doped diamond film which were synthesized at 1173K substrate temperature were 2 3μm2 3μm in diameter and nucleation densities were 108numbers/cm2108numbers/cm2 order. The diamond film synthesized at 673K was 0.2μm0.2μm in diameter and nucleation densities was 109 numbers/cm2 order. The diamond film synthesized by pulse microwave plasma CVD at 1173K was 0.2μm0.2μm in diameter and nucleation density was 109numbers/cm2109numbers/cm2 order either. From the result of electron field emission measurement, electron field emission at 20V/μm20V/μm from CVD diamond film synthesized by pulse microwave plasma CVD was 37.3μA/cm237.3μA/cm2 and the diamond film showed the best field emission property comparison with other CVD diamond.

  • PDF

Numerical simulation of a regenerative thermal oxidizer for volatile organic compounds treatment

  • Hao, Xiaowen;Li, Ruixin;Wang, Jiao;Yang, Xinfei
    • Environmental Engineering Research
    • /
    • 제23권4호
    • /
    • pp.397-405
    • /
    • 2018
  • As regulations governing the control of volatile organic compounds (VOCs) have become increasingly stringent in China, regenerative thermal oxidizers (RTOs) have been more frequently applied in medium- and high-concentration VOCs treatments. However, due to the lack of existing RTO-related research, experience remains a dominant factor for industrial application. This paper thus aimed to establish a model for industrial RTOs, using a transient simulation method and thermal equilibrium model to simulate the internal velocities and temperature distributions of an RTO across multiple cycles. A comparison showed an error of less than 5% between most correlating simulated and experimental measurement points, verifying that the simulation method was accurate. After verification, the velocity and temperature fields inside the RTO were simulated to study the uniformity of temperature and velocity within the packed beds: both fields displayed high uniformity after gas flowed through the honeycomb regenerator. The effects of air volume, VOCs concentrations, and valve switching times on the oxidation chamber temperature, RTO outlet temperature, and thermal efficiency (as well as their averages) were studied. The VOCs removal rate in this study was constantly above 98%, and the average thermal efficiency reached 90%.

알루미늄 분말 점화용 고밀도 스팀 플라즈마 제트 온도장 및 방출 스펙트럼 측정 (Temperature Field and Emission Spectrum Measurement of High Energy Density Steam Plasma Jet for Aluminum Powder Ignition)

  • 이상협;임지환;이도형;윤웅섭
    • 한국추진공학회지
    • /
    • 제18권1호
    • /
    • pp.26-32
    • /
    • 2014
  • 본 연구에서 고에너지 금속 알루미늄의 효과적인 점화를 위해 개발한 직류 방식의 스팀 플라즈마 점화기 가스온도를 OH radical의 방출 스펙트럼을 사용하여 측정하였다. 플라즈마 제트온도는 초고온이므로 비접촉식 광학 계측 방법인 볼츠만 기울기법과 스펙트럼 비교 분석법을 이용하여 측정하였으며 각각의 방법은 정밀하게 검증 후 실험에 적용되었다. 플라즈마 점화기의 노즐 팁으로부터 30 mm 범위에서의 제트온도 측정결과 두 방법 모두 알루미늄의 점화온도(2400K2400K) 이상의 2900 K ~ 5800 K를 확인할 수 있었다.

대형 강의실의 실내 열환경 실측 및 컴퓨터시뮬레이션 비교 연구 (Field Measurements and CFD Simulations of Indoor Thermal Environments in the Assembly Hall)

  • 윤재옥
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.179-186
    • /
    • 2004
  • The evaluation of the indoor environment of the Assembly Hall in the University, which is designed to be a large space, requires efficient design of its heating system that takes into consideration natural convection and the characteristics of the occupant's spaces. Indoor thermal environment was measured in the field and simulated with CFD code. The estimations of temperature distribution and indoor airflow distribution must be carried out simultaneously, as the thermal stratification is induced by natural convection flows. In order to simulate the even distribution of factors affecting the indoor environment, including temperature and airflow, Phoenics is used. The turbulent flow model adopted is the RNG k- model. The inlets and outlets of the air-conditioning systems, material and thermal properties, and the size of the test room (35m×18m×10m35m×18m×10m) are used for the simulation. Since the Assembly Hall is symmetric, half of the space is simulated. A Cartesian grid is used for calculation and the number of grids are respectively 60×45×3560×45×35. The results of the computer simulation during winter conditions are compared with the measurements at the typical points in the assembly hall with the heating system. After evaluating the results of the computer simulations, the methods of the heating system and layout are suggested.

아두이노와 초음파 센서를 이용한 실험용 수위 측정 장치 개발 (Development of experimental water level measuring device using an Arduino and an ultrasonic sensor)

  • 유문성
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.143-147
    • /
    • 2018
  • 수위는 하수장, 정수장, 하천, 댐, 공장의 저장탱크 등 다양한 분야에서 측정된다. 수위측정을 위한 초음파 기기가 판매중이나 산업용으로 실험에서 사용하기는 가격이 너무 비싸다. 전자 기술의 급속한 진보로 인해 다양한 종류의 측정, 모니터링 및 제어 기능이 저렴하게 구축하는 것이 가능해졌다. 저렴한 가격으로 초음파 수위 측정시스템을 만들기 위하여 본 연구가 시작되었다. 실험용으로 사용하기 위하여 아두이노, 초음파 센서 및 온도 센서로 시스템을 구성하였다. 초음파 센서는 센서에서 수위 표면까지의 시간을 측정한다. 온도 센서는 대기 온도를 측정하며 온도 변화로 인한 소리의 속도를 보정하여 초음파 거리 측정의 정확성을 높인다. 아두이노는 측정 전반을 관리하고 수위를 계산한다. 시스템의 모든 구성 요소는 장치거치대에 조립되었다. 제안된 시스템을 가지고 실험한 결과 수위가 실측치와 매우 가까웠다. 이 시스템은 또한 저렴하며 설치 및 유지하기가 쉬워 실험용으로 적절하다.

Use of uniform distribution for generating synthetic brightness temperature in passive microwave soil moisture retrieval

  • Lee Khil-Ha
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.19-28
    • /
    • 2005
  • Passive microwave remote sensing technique have shown great potential for mon monitoring regional/global surface soil moisture. Given a single measurement at dual polarization/single frequency/single view angle, a strategic approach to artificially generating multiple microwave brightness temperatures is presented. And then the statistically generated microwave brightness temperature data are applied to the inverse algorithm, which mainly relies on a physically based microwave emission model and an advanced single-criterion multi-parameter optimization technique, to simultaneously retrieve soil moisture and vegetation characteristics. . The procedure is tested with dual polarized Tropical Rainfall Measurement Mission Microwave Imager (TRMM/TMI) over two different cover sites in Oklahoma and Beltsville field experimental data. The retrieval results are analyzed and show excellent performance.

  • PDF

전력케이블용 절연재료의 캐리어 극성 및 공간전하 측정기술에 관한 연구-PE-EVA에서의 하전입자의 거동 (A Study on the Space Charge Measurement Technique and Carrier Polarity of Insulating Materials on Power Cable)

  • 국상훈;박중순;강용철;권영수
    • 대한전기학회논문지
    • /
    • 제41권2호
    • /
    • pp.185-191
    • /
    • 1992
  • In this paper, it is attempted to distinguish the charged particles and to judge the polarity by the use of Thermally Stimulated Current(TSC) and Temperature Gradient Thermally Stimulated Surface Potential Measurement(TG-TSSP)with experimental insulation material XLPE-EVA for power cables which is made by blending cross-linked polyethylene(XLPE) and ethylene-vinylacetate copolymer(EVA). In addition, it is performed to investigate the effect of EVA blending. From the experimental results, it is known that for the case of XLPE-EVA blended experimental material, the generation of space charged electric field is not obtained in the high temperature region due to the obatruction of the injection of trapping carrier by the electron and the positive hole.

  • PDF