• Title/Summary/Keyword: Temperature decreasing

Search Result 2,035, Processing Time 0.032 seconds

Development of Data-driven Thermal Protection Algorithm for Protecting Overheating of Motor in the Sunroof System (선루프 모터 과열 방지를 위한 데이터 기반 열 차폐 알고리즘 개발)

  • Kim, Hyun-Hee;Park, Seong-U;Lee, Kyung-Chang;Hwang, Yeong-Yeun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.4
    • /
    • pp.223-230
    • /
    • 2016
  • This paper presents data-driven thermal protection algorithm for preventing overheating of automotive sunroof motor. When a sunroof motor operates abnormally, its coil is overheated and it is failed. Besides, drivers and passengers are damaged. Hence, the sunroof motor observes its temperature and will be stoped when its temperature reach a predefined level. In order to implement low-cost thermal protection function, we drew a knowledge-based temperature increasing and decreasing curve from the result of experimental test. And then, we implemented data-driven thermal protection algorithm which prevents motor's On/Off operation according to motor operating voltage and motor speed. Finally, we implemented experimental test bed and evaluated its feasibility.

Temperature dependences of the band-gap energy and the PC intensity for $CuInSe_2$ thin films

  • You, Sang-Ha;Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.139-140
    • /
    • 2008
  • In this study, the photocurrent (PC) spectroscopy of undoped p-type CIS layers has been investigated at temperatures ranging from 10 to 293 K. Three peaks, A, B, and C, corresponded to the intrinsic transition from the valence band states off $\Gamma_7$(A), $\Gamma_6$(B), and $\Gamma_7$(C) to the conduction band state $\Gamma_6$, respectively. The crystal field splitting and the spin orbit splitting were found at 0.0059 and 0.2301 eV, respectively, and the temperature dependence of the optical band gap could be expressed by using the empirical equation $E_g$(T) = $E_g$(0) - $(8.57\times10^{-4)T^2$/(T + 129). But the behavior of the PC was different from that generally observed in other semiconductors: the PC intensities decreased with decreasing temperature. From the relation of log $J_{ph}$ vs 1/T, where $J_{ph}$ is the PC density, the dominant level was observed at the higher temperatures. We suggest that in undoped p-type CIS layers, the trapping center limits the PC signal due to native defects and impurities with decreasing temperature.

  • PDF

Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor (인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

Effect of Humidity and Operating Temperature of Polymer Sensor to Methanol Gas (Methanol 가스에 대한 고분자 센서의 온도와 습도 영향 고찰)

  • Lee, K.M.;Hoh, Y.S.;Jun, H.K.;Sohn, S.O.;Huh, J.S.
    • Korean Journal of Materials Research
    • /
    • v.13 no.12
    • /
    • pp.796-800
    • /
    • 2003
  • The polypyrrole prepared with pyrrole monomer, APS and DBSA was synthesized by chemical Polymerization at $V^{\circ}C$ under atmosphere conditions. After dissolving polypyrrole powder to the chloroform including DBSA, polypyrrole film was prepared on the alumina substrate with an interdigitated electrode by using the dip-coating method. This film was soaked in methanol solvent for 1 h at room temperature and heated to $70^{\circ}C$ for 4 h in $N_2$. Initial resistance was increased with the increasing humidity and decreasing temperature. The sensitivity was increased with lower humidity and decreasing temperature. The best linearity was achieved at $25^{\circ}C$ and low humidity of 0%.

Selective Contact Hole Filling by electroless Ni Plating (무전해 Ni 도금에 의한 선택적 CONTACT HOLE 충전)

  • 우찬희;권용환;김영기;박종완;이원해
    • Journal of Surface Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.189-206
    • /
    • 1992
  • The effect of activation and electroless nickel plating conditions on contact properties was investi-gated for selective electroless nickel plating of Si wafers in order to obtain an optimum condition of con-tact hole filling. According to RCA prosess, p-type silicon (100) surface was cleaned out and activated. The effects of temperature, DMAB concentration, time, and strirring were investigated for activation of p-type Si(100) surface. The optimal activation condition was 0.2M HF, 1mM PdCl2, 2mM EDTA,$ 70^{\circ}C$, and 90sec under ultrasonic vibration. In electroless nickel plating, the effect of temperature, DMAB concentra-tion, pH, and plating time were studied. The optimal plating condition found was 0.10M NiSO4.H2O, 0.11M Citrate, pH 6.8, $60^{\circ}C$, 30minutes. The contact resistance of films was comparatively low. It took 30minutes to obtain 1$\mu\textrm{m}$ thick film with 8mM DMAB concentration. The film surface roughness was improved with decreasing temperature and decreasing pH of the plating solution. The best quality of the film was obtained at the condition of temperature $60^{\circ}C$ and pH 6.0. The micro-vickers hardness of film was about 800Hv. Plating rate of nickel on the hole pattern was slower than that of nickel on the line pattern.

  • PDF

Composition and Temperature Dependence of Structural Changes in Borosilicate Glasses by Spectrometer (분광계에 의한 Borosilicate계 글라스의 조성 및 온도의존성 평가)

  • Park Sung-Je;Ryu Bong-Ki
    • Korean Journal of Materials Research
    • /
    • v.15 no.12
    • /
    • pp.786-790
    • /
    • 2005
  • We investigated the particularity of temperature and composition changes in $xNa_2O{\cdot}(52.5-x)B_2O_3{\cdot}47.5SiO_2$ glasses by use of FT-IR, $^{11}B$ NMR, Raman spectrometer. From FT-IR and $^{11}B$ NMR spectrometer, we thought that tetrahedral boron, $BO_4$ units are created $N_4$ increasing tendency generated near $600^{\circ}C$. It's expected that composition ana heat treatment directly contributed to structural changes, this changes are following to $Na_2O$ increasing or decreasing. caused by $N_4\;and\;BO_4$ units are caused by relatively increasing or decreasing in the glasses' structure. Particularly, $BO_4$ units are converted to $BO_3$ units after $600^{\circ}C$ heat treatment for 50h in the composition of $x<18(R<0.5,\;R=Na_2O/B_2O_3\;mol\%)$. On the order hand, $BO_3$ units are converted to, $BO_4$ units after $600^{\circ}C$ heat treatment for 50h in the composition of $x{\geq}18\;(R>0.5)$. This particularity of composition and temperature dependence of structural changes are similarly represented by Raman analysis results.

Thermodynamics of 2, N-Dimethyl Pyridinium Iodide in Ethanol-Water Mixture under High Pressure

  • Jee, Jong-Gi;Lee, Young-Hwa;Woo, Eui-Ha;Lee, Kyung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.4 no.3
    • /
    • pp.115-119
    • /
    • 1983
  • The ionic association constants (K) of 2, N-dimethyl pyridinium iodide (2NDMPI) in 95 volume percentage ethanol-water mixture were determined by a modified UV and conductance method at $20^{\circ}C{\sim}50^{\circ}C$ under 1 to 2000 bars. The K values increase with increasing pressure and decrease with temperature. The total partial molar volume change (${\Delta}V$) has relatively small negative value and the absolute ${\Delta}V$ value decrease with increasing pressure and temperature. The ion size (a) and solvation number (n) of 2NDMPI were about 5 $\AA$ and changed from 1 to 3 with decreasing temperature. Other thermodynamic parameters such as enthalpy (${\Delta}H^{\circ}$) and entropy (${\Delta}S^{\circ}$) for the equilibrium of the 2NDMPI were evaluated. From all the parameters mentioned above, we came to conclusion that the electrostriction effect of 2NDMPI in the ethanol-water mixture is enhanced with increasing pressure and decreasing temperature.

Correlation on Compressor Discharge Temperature of System A/C Applying PWM Scroll Compressor in Cooling Mode (PWM 스크롤압축기를 적용한 시스템 에어컨의 냉방운전 시 압축기 토출온도에 대한 상관식 개발)

  • Kwon, Young-Chul;Park, Sam-Jin;Ko, Kuk-Won;Park, Byung-Kwon;Kim, Dae-Hun;Youn, Baek
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.154-159
    • /
    • 2006
  • An experimental study has been performed to investigate the correlation on compressor discharge temperature of capacity modulated system A/C in cooling mode. Indoor and outdoor temperatures, the cooling capacity, compressor discharge temperature and loading time are measured by the psychrometric calorimeter. The system is controlled by applying the scroll compressor operated by PWM valve and loading duty. With decreasing outdoor temperature, the cooling capacity increases. But, with decreasing indoor temperature, it decreases. According to the increase in outdoor temperature and loading duty, compressor discharge temperature increases. From these experimental data, the correlation on compressor discharge temperature is proposed. The correlation obtained from the present study is agreed with the experimental data within $3^{\circ}C$.

The Change of Diurnal Temperature Range in South Korea (우리나라의 일교차 변화에 관한 연구)

  • Heo, In-Hye;Lee, Seung-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.17 no.2
    • /
    • pp.167-180
    • /
    • 2011
  • This paper investigates the changes of diurnal temperature range (DTR) by season and region in South Korea using daily maximum temperature and daily minimum temperature from 1954 to 2009. It also attempts to find what causes these changes. The daily minimum temperature distinctively increased during the latter half of the research period (1988~2009) than the first half of the year (1954~1987) leading decreases in DTR, while the rise in daily maximum temperature was not distinct during the research period. The DTR shows slightly increasing trend in spring. but decreasing trend in fall. The DTR is decreasing in urban region while it is increasing in rural area. The degree of the DTR decrease is bigger in large urban region than in medium-small urban region. The DTR in urban region is affected by the amount of clouds in spring and tile duration of sunshine in fall. The DTR in rural area is affected by the amount of clouds in spring and the number of days with precipitation in fall.

  • PDF

A Study of Polymer/Ceramics Composite with Application to Dye Host (유기염료의 HOST로 응용된 고분자/세라믹 복합체에 관한 연구)

  • 이동아;김구대;강현규;문지웅
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.4
    • /
    • pp.367-374
    • /
    • 1994
  • Inorganic-organic composite was made through sol-gel process. Possible range for hosting organic dye was investigated with various composition. The transmittance of the composite was the most important condition for a host was increased to 90% with decreasing HCl as a catalyst. Clear absorbance peak was obtained by decreasing concentration of organic dye, fluorescent intensity was increased and transmittance was decreased with rising gelling temperature.

  • PDF